Search NASA⌕ Search

SEARCH · Search NASA

Results for “Independent component analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Different Approaches for Ensuring Performance/Reliability of Plastic Encapsulated Microcircuits (PEMs) in Space Applications

Engineers within the commercial and aerospace industries are using trade-off and risk analysis to aid in reducing spacecraft system cost while increasing performance and maintaining high reliability. In many cases, Commercial Off-The-Shelf (COTS) components, which include Plastic Encapsulated Microcircuits (PEMs), are candidate packaging technologies for spacecrafts due to their lower cost, lower weight and enhanced functionality. Establishing and implementing a parts program that effectively and reliably makes use of these potentially less reliable, but state-of-the-art devices, has become a significant portion of the job for the parts engineer. Assembling a reliable high performance electronic system, which includes COTS components, requires that the end user assume a risk. To minimize the risk involved, companies have developed methodologies by which they use accelerated stress testing to assess the product and reduce the risk involved to the total system. Currently, there are no industry standard procedures for accomplishing this risk mitigation. This paper will present the approaches for reducing the risk of using PEMs devices in space flight systems as developed by two independent Laboratories. The JPL procedure involves primarily a tailored screening with accelerated stress philosophy while the APL procedure is primarily, a lot qualification procedure. Both Laboratories successfully have reduced the risk of using the particular devices for their respective systems and mission requirements.

Gerke, R. David↗

NPP VIIRS and Aqua MODIS RSB Comparison Using Observations from Simultaneous Nadir Overpasses (SNO)

Suomi NPP (National Polar-orbiting Partnership) satellite (http://npp.gsfc.nasa.gov/viirs.html) began to daily collect global data following its successful launch on October 28, 2011. The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key NPP sensor. Similar to the design of the OLS, SeaWiFS and MODIS instruments, VIIRS has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. Immediately after the VIIRS nadir door s opening on November 21, 2011, anomalously large degradation in the SD response was identified in the near-IR wavelength region, which was unexpected as decreases in the SD reflectance usually occur gradually in the blue (~0.4 m) wavelength region based on past experience. In this study, we use a well-calibrated Aqua MODIS as reference to track and evaluate VIIRS RSB stability and performance. Reflectances observed by both sensors from simultaneous nadir overpasses (SNO) are used to determine VIIRS to MODIS reflectance ratios for their spectral matching bands. Results of this study provide an immediate post-launch assessment, independent validation of the anomalous degradation observed in SD measurements at near-IR wavelengths and initial analysis of calibration stability and consistency.

Xiong, X.↗

Automatic variable selection in ecological niche modeling: A case study using Cassin’s Sparrow (Peucaea cassinii)

MERRA/Max provides a feature selection approach to dimensionality reduction that enables direct use of global climate model outputs in ecological niche modeling. The system accomplishes this reduction through a Monte Carlo optimization in which many independent MaxEnt runs, operating on a species occurrence file and a small set of randomly selected variables in a large collection of variables, converge on an estimate of the top contributing predictors in the larger collection. These top predictors can be viewed as potential candidates in the variable selection step of the ecological niche modeling process. MERRA/Max’s Monte Carlo algorithm operates on files stored in the underlying filesystem, making it scalable to large data sets. Its software components can run as parallel processes in a high-performance cloud computing environment to yield near real-time performance. In tests using Cassin’s Sparrow (Peucaea cassinii) as the target species, MERRA/Max selected a set of predictors from Worldclim’s Bioclim collection of 19 environmental variables that have been shown to be important determinants of the species’ bioclimatic niche. It also selected biologically and ecologically plausible predictors from a more diverse set of 86 environmental variables derived from NASA’s Modern-Era Retrospective Analysis for Research and Applications Version 2 (MERRA-2) reanalysis, an output product of the Goddard Earth Observing System Version 5 (GEOS-5) modeling system. We believe these results point to a technological approach that could expand the use global climate model outputs in ecological niche modeling, foster exploratory experimentation with otherwise difficult-to-use climate data sets, streamline the modeling process, and, eventually, enable automated bioclimatic modeling as a practical, readily accessible, low-cost, commercial cloud service.

John L. Schnase↗

Development of an MC&A toolbox for liquid-fueled molten salt reactors with online reprocessing (Final Report)

A critical barrier to the deployment of MSRs is the absence of a well-defined nuclear material control and accounting (MC&A) approach, a vital prerequisite to meet NRC licensing requirements as well as facilitating future international exports. Liquid-fueled MSR variants (especially those incorporating online refueling or reprocessing) present a unique set of challenges to traditional nuclear material control and accountancy. Unlike solid-fueled light-water reactors, traditional item-counting methods cannot be applied as an accountancy strategy. Rather, MC&A approaches to MSR variants (including both uranium and thorium fueled designs) are more analogous to bulk material handling facilities (e.g., enrichment and reprocessing); yet further complicating matters is the fact that fuel medium is also highly radioactive. Meanwhile, the space of MSRs covers a broad range of design parameters, including thermal and fast spectra designs; operation in actinide breeder or burner modes, choice of actinide fuel used (e.g., 235 U, 232 Th / 233 U, denatured 233 U, etc.), pool or loop-type configuration, and even different salt chemistry. Each of these design choices introduce significant challenges to MC&A approaches within MSR facilities. We propose to bridge this gap for liquid-fueled MSRs by developing a modular, component-based test framework for evaluating viable process monitoring and MC&A techniques specifically suited to liquid-fueled MSR system variants employing online refueling or reprocessing. This test platform will consist of a toolbox of independent process modules representing discrete physical units (such as the reactor core, off-gas processing, decay tanks, and actinide separation units), each with its own self-contained physics responsive to the input mass flow, along with appropriate measurement models that can be coupled to key flow points. These dynamic physical signatures thus afford the ability to test the viability and efficacy of potential accountancy techniques under the full range of reactor operating conditions. As process modules are connected via mass flows, the result is a reconfigurable, generic MSR mass flow model capable of serving as an MC&A test platform for a broad spectrum of possible MSR configurations. The resulting MSR MC&A toolbox will enable robust assessment of accountancy strategies for this unique facility type, including analysis of physical feedbacks arising both from depletion of the fuel over time as well as from potential off-normal events, including those introduced by equipment failures (e.g., a pump failure) as well as by malicious action (i.e., attempts to divert material). The proposed toolbox both addresses a critical needs area for the MPACT analysis toolkit while leveraging existing MPACT-sponsored tools, especially with respect to simulation of measurement and accountancy techniques for advanced fuel cycle facilities. Beyond enabling new analysis capabilities for MSR systems, the design of this toolbox will be to such to maximize compatibility with existing MPACT tools, such to enhance existing facility MC&A analysis capabilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Optically accessible, high pressure, hot fire test articles are available at NASA Marshall for use in development of advanced rocket engine propellant injectors. Single laser-pulse ultraviolet (UV) Raman spectroscopy has been used in the past in these devices for analysis of high pressure H2- and CH4-fueled combustion, but relies on an independent pressure measurement in order to provide temperature information. A variation of UV Raman (High Resolution Hydrogen Raman Spectroscopy) is under development and will allow temperature measurement without the need for an independent pressure measurement, useful for flows where local pressure may not be accurately known. The technique involves the use of a spectrometer with good spectral resolution, requiring a small entrance slit for the spectrometer. The H2 Raman spectrum, when created by a narrow linewidth laser source and obtained from a good spectral resolution spectrograph, has a spectral shape related to temperature. By best-fit matching an experimental spectrum to theoretical spectra at various temperatures, a temperature measurement is obtained. The spectral model accounts for collisional narrowing, collisional broadening, Doppler broadening, and collisional line shifting of each Raman line making up the H2 Stokes vibrational Q-branch spectrum. At pressures from atmospheric up to those associated with advanced preburner components (5500 psia), collisional broadening though present does not cause significant overlap of the Raman lines, allowing high resolution H2 Raman to be used for temperature measurements in plumes and in high pressure test articles. Experimental demonstrations of the technique are performed for rich H2-air flames at atmospheric pressure and for high pressure, 300 K H2-He mixtures. Spectrometer imaging quality is identified as being critical for successful implementation of technique.

Wehrmeyer, Joseph A.↗

Preparing for Veg-04 and Veg-05: Improving Pick-And-Eat Food Capabilities for the International Space Station

The capability to grow nutritious, palatable food for crew consumption during spaceflight has the potential to provide health-promoting, bioavailable nutrients, enhance the dietary experience, and reduce launch mass as we move toward longer-duration missions. Studies of edible produce during spaceflight have been limited, leaving a significant knowledge gap in the methods required to grow safe, acceptable, nutritious crops for consumption in space. Researchers from Kennedy Space Center, Johnson Space Center, Purdue University and ORBITEC have teamed up to explore the potential for plant growth and food production on the International Space Station (ISS) and future exploration missions. Ground testing of Chinese cabbage and dwarf tomato crops under different LED lighting and fertilizer conditions is being conducted to allow for a preliminary down selection of the two best lighting recipes and the best fertilizer treatment. Two trials of Chinese cabbage and one trial on dwarf tomato have been completed in on-going ground tests. Horticultural data on crop growth and productivity and chemical data on specific nutrients have been collected and are being analyzed to allow preliminary down selection. Taste test evaluations are planned on the preliminary down selection treatments to allow a final down selection for flight testing. Microbial assessment for hazard analysis critical control points (HACCP) evaluation is also underway to enable implementation of food consumption. Following down selection flight preparation will commence for testing these crops in the Veggie vegetable-production system on the ISS. A crew questionnaire has been developed to better understand the impact of crop growth in Veggie on crew behavioral health. A single Veggie plant growth chamber is currently installed on ISS, and preparations are underway to launch a second Veggie, allowing side-by-side testing under different lighting conditions. Veg-04 will be the first mission that will use this dual-Veggie capability, where the selected cultivar of Tokyo bekana Chinese cabbage will be grown under two different red-to-blue light ratios. ORBITEC has developed custom lighting software allowing independent selection of red and blue light levels. The VEG-05 experiment will test similar light treatments using Red Robin dwarf tomato. These tests offer an opportunity to develop a pick-and-eat fresh vegetable component to the ISS food system as a first step to regular supplemental food production. Our work will help define light colors, levels, and horticultural best practices to achieve high yields of safe, nutritious leafy greens and tomatoes to supplement a space diet of prepackaged food. With this work we will continue the synergistic research to help close gaps in the human research roadmap, and enable humans to venture to Mars and beyond. This research was co-funded by the Human Research Program and Space Biology (MTL1075) in the ILSRA 2015 NRA call.

International Space Station↗

A new perspective on density and strength loss profiles at the surface of thermally oxidized nuclear graphite

Oxidation of graphite components could influence their designed life in a high-temperature nuclear reactor. The oxidized regions could potentially lower the allowed stress capacity. The American Society of Mechanical Engineers rules for the design and construction of graphite-moderated reactors recommend that subsurface regions that might become excessively damaged by oxidation during reactor operation be identified and excluded from geometry and stress calculations. Identification of oxidation-affected regions is possible, in principle, through complex modeling exercises of reactor behavior during hypothetical accident scenarios coupled with graphite oxidation models, but this procedure may not have the precision needed for informed decisions. Here, this paper proposes an alternate method, based on interpretation of a series of well-designed oxidation experiments, which could augment the designer's tools. The procedure is illustrated by data on oxidation by air of several graphite grades (NBG-18, PCEA, IG-110, R4-650) that are corroborated with independent literature information, when available. The Wichner model for graphite oxidation used for this analysis provides conservative results that could be quickly implemented in the design process.

36 MATERIALS SCIENCE↗

Time Variable Gravity from Local Mascon Analysis of GRACE Data

We have analyzed GRACE Level 1-B data in 2003 and assessed a new approach for extracting time variable gravity that isolates the gravity signal in both time and space. The Level-1B satellite-to-satellite range rate (KBRR) data and accelerometry are processed in daily arcs using the precise orbit products produced by the GRACE team from GPS to calibrate both the accelerometer and KBRR data. We then adjusted select components of the intersatellite baseline vector for each data segment isolated to the region of interest. Herein, we solved for mass anomalies in 45 deg x 45 deg blocks over the Amazon and the nearby Atlantic Ocean and estimate mass flux in units of cm of water over each block. We show with this approach that we can recover mass anomalies on a submonthly basis with 10 to 15 day temporal resolution. We discuss the important issues related to this solution, including the size of the mascon blocks, the weight given to the temporal and spatial constraint used to stabalize the solutions, as well as the optimal correlation in time and distance. We compare the the mascon results with solutions obtained from the more standard approach using spherical harmonics and with independent hydrology models and lake data. This technique demonstrates that sub-monthly medium wavelength mass flux phenomena are well sensed by the hyper-precise line of sight velocity data produced from GRACE.

Lemoine, Frank G.↗

Shadowgraph Study of Gradient Driven Fluctuations

A fluid or fluid mixture, subjected to a vertical temperature and/or concentration gradient in a gravitational field, exhibits greatly enhanced light scattering at small angles. This effect is caused by coupling between the vertical velocity fluctuations due to thermal energy and the vertically varying refractive index. Physically, small upward or downward moving regions will be displaced into fluid having a refractive index different from that of the moving region, thus giving rise to the enhanced scattering. The scattered intensity is predicted to vary with scattering wave vector q, as q(sup -4), for sufficiently large q, but the divergence is quenched by gravity at small q. In the absence of gravity, the long wavelength fluctuations responsible for the enhanced scattering are predicted to grow until limited by the sample dimensions. It is thus of interest to measure the mean-squared amplitude of such fluctuations in the microgravity environment for comparison with existing theory and ground based measurements. The relevant wave vectors are extremely small, making traditional low-angle light scattering difficult or impossible because of stray elastically scattered light generated by optical surfaces. An alternative technique is offered by the shadowgraph method, which is normally used to visualize fluid flows, but which can also serve as a quantitative tool to measure fluctuations. A somewhat novel shadowgraph apparatus and the necessary data analysis methods will be described. The apparatus uses a spatially coherent, but temporally incoherent, light source consisting of a super-luminescent diode coupled to a single-mode optical fiber in order to achieve extremely high spatial resolution, while avoiding effects caused by interference of light reflected from the various optical surfaces that are present when using laser sources. Results obtained for a critical mixture of aniline and cyclohexane subjected to a vertical temperature gradient will be presented. The sample was confined between two horizontal parallel sapphire plates with a vertical spacing of 1 mm. The temperatures of the sapphire plates were controlled by independent circulating water loops that used Peltier devices to add or remove heat from the room air as required. For a mixture with a temperature gradient, two effects are involved in generating the vertical refractive index gradient, namely thermal expansion and the Soret effect, which generates a concentration gradient in response to the applied temperature gradient. For the aniline/cyclohexane system, the denser component (aniline) migrates toward the colder surface. Consequently, when heating from above, both effects result in the sample density decreasing with altitude and are stabilizing in the sense that no convective motion occurs regardless of the magnitude of the applied temperature gradient. The Soret effect is strong near a binary liquid critical point, and thus the dominant effect is due to the induced concentration gradient. The results clearly show the divergence at low q and the predicted gravitational quenching. Results obtained for different applied temperature gradients at varying temperature differences from the critical temperature, clearly demonstrate the predicted divergence of the thermal diffusion ratio. Thus, the more closely the critical point is approached, the smaller becomes the temperature gradient required to generate the same signal. Two different methods have been used to generate pure concentration gradients. In the first, a sample cell was filled with a single fluid, ethylene glycol, and a denser miscible fluid, water, was added from below thus establishing a sharp interface to begin the experiment. As time went on the two fluids diffused into each other, and large amplitude fluctuations were clearly observed at low q. The effects of gravitational quenching were also evident. In the second method, the aniline/cyclohexane sample was used, and after applying a vertical temperature gradient for several hours, the top and bottom temperatures were set equal and the thermal gradient died on a time scale of seconds, leaving the Soret induced concentration gradient in place. Again, large-scale fluctuations were observed and died away slowly in amplitude as diffusion destroyed the initial concentration gradient.

Cannell, David↗

Bayesian Estimation of Precipitation from Satellite Passive Microwave Observations Using Combined Radar-Radiometer Retrievals

Precipitation estimation from satellite passive microwave radiometer observations is a problem that does not have a unique solution that is insensitive to errors in the input data. Traditionally, to make this problem well posed, a priori information derived from physical models or independent, high-quality observations is incorporated into the solution. In the present study, a database of precipitation profiles and associated brightness temperatures is constructed to serve as a priori information in a passive microwave radiometer algorithm. The precipitation profiles are derived from a Tropical Rainfall Measuring Mission (TRMM) combined radar radiometer algorithm, and the brightness temperatures are TRMM Microwave Imager (TMI) observed. Because the observed brightness temperatures are consistent with those derived from a radiative transfer model embedded in the combined algorithm, the precipitation brightness temperature database is considered to be physically consistent. The database examined here is derived from the analysis of a month-long record of TRMM data that yields more than a million profiles of precipitation and associated brightness temperatures. These profiles are clustered into a tractable number of classes based on the local sea surface temperature, a radiometer-based estimate of the echo-top height (the height beyond which the reflectivity drops below 17 dBZ), and brightness temperature principal components. For each class, the mean precipitation profile, brightness temperature principal components, and probability of occurrence are determined. The precipitation brightness temperature database supports a radiometer-only algorithm that incorporates a Bayesian estimation methodology. In the Bayesian framework, precipitation estimates are weighted averages of the mean precipitation values corresponding to the classes in the database, with the weights being determined according to the similarity between the observed brightness temperature principal components and the brightness temperature principal components of the classes. Because the classes are stratified by the sea surface temperature and the echo-top-height estimator, the number of classes that are considered for retrieval is significantly smaller than the total number of classes, making the algorithm computationally efficient. The radiometer-only algorithm is applied to TMI observations, and precipitation estimates are compared with combined TRMM precipitation radar (PR) TMI reference estimates. The TMI-only algorithm, supported by the empirically derived database, produces estimates that are more consistent with the reference values than the precipitation estimates from the version-6 TRMM facility TMI algorithm. Cloud-resolving model simulations are used to assign a latent heating profile to each precipitation profile in the empirically derived database, making it possible to estimate latent heating using the radiometer-only algorithm. Although the evaluation of latent heating estimates in this study is preliminary, because realistic conditional probability distribution functions are attached to latent heating structures in the algorithm s database, a generally positive impact on latent heating estimation from passive microwave observations is expected.

Grecu, Mircea↗

Final Report on the Detection of Green Monopropellants

In 2014, National Aeronautics and Space Administration (NASA) Kennedy Space Center (KSC) funded a project titled "Familiarization and Detection of Green Monopropellants" utilizing Independent Research and Technology Development (IR&TD) and Center Innovation Fund (CIF) funding. The purpose of the project was to evaluate methods of detection for ammonium dinitramide (ADN) and hydroxylammonium nitrate (HAN). An Engineering Services Contract (ESC) task order was created with the scope of evaluation of several methods of detecting ADN- and HAN-based propellants, as well as development of methods for detection. Detection methods include developed methods such as colorimetric indicating absorbent socks, and commercial-off-the- shelf (COTS) units for ammonia detection. An additional goal of the task order was for ESC to become familiar with ADN's and HAN's material properties and material compatibility. Two approaches were initially investigated as possible methods for the detection of HAN (or AFM315E) and ADN (or LMP-103S). These approaches were colorimetric analysis and instrumentation-based COTS vapor sensors utilization. Initial testing showed that the relatively non-existent vapor pressure of the AF-M315E (of which HAN is a major component) propellant would make the use of COTS sensors difficult for real-time area monitoring of HAN; a small response was detected through the use of active COTS sensors, including the RAE Systems MultiRAE Lite and Drager X-act (registered) 5000, but the levels detected were below the threshold limit value for the toxic gas ammonia. Therefore, a detection system ased upon a colorimetric indicator impregnated into an absorbent material was developed. Preliminary analysis (ESC-245-FDG-001) identified a particularly outstanding candidate as a colorimetric indicator for the detection of the presence of AF-M315E in the form of a Methyl Red (Basic) indicator. Materials impregnated with this indicator exhibit significant color change and the materials are not susceptible to interference from exposure to water or carbon dioxide. The completed detection system for HAN/AF-M315E consists of absorbent socks packed with Fisher Universal Spill Absorbent capable of absorbing and containing any propellant spills that they come into contact with along with indicating wipes. The absorbent socks are also chemically treated with a Methyl Red (Basic) indicator solution to provide the end user with a visual indication that a leak has occurred and proper protective precautions must be undertaken. An added benefit of this detection system is that the absorbent socks should neutralize/absorb any commodity that it comes into contact with (until saturation is reached). Additional adsorbent socks can be deployed until a color change is not seen, indicating that the HAN/AF-M315E contamination has been contained. The indicating wipes provide the user the opportunity to wipe surfaces to determine if there is any HAN/AF-M315E or HAN/AFM315E residue present. The wipes should allow the detection of fuel levels that may be too small to detect with the absorbent socks. The development of a detection system for the ADN/LMP-103S focused on the use of various COTS sensors used as real-time area monitoring devices and personal dosimeters. These COTS based sensor systems were of several different types, including both actively pumped and diffusion-based passive systems, as well as a "rope"-type chemical sensing cable. The results highlighted some of the major differences between the two monopropellants undergoing evaluation. Unlike HAN, ADN (which is the major constituent of LMP-103S) exhibits a much more volatile nature in comparison to AF-M315E. In fact, testing showed that a large percentage of the fuel was lost during the sampling measurement (greater than 10 percent by mass); although this testing cannot tell if the volatile component is the ADN itself or another component of the monopropellant solution. Not surprisingly, all four of the procured vapor-based COTS sensors showed positive results when exposed to solutions of the LMP-103S (ESC-245-FDG-002). The completed detection system for ADN/LMP-103S consists of a combination of two of the tested COTS sensor systems, the RAE Systems MultiRAE Lite and the BW Technologies GasAlert Extreme. These systems are meant to be used in conjunction with one another, which allows for the end-user to have both real-time area monitoring (MultiRAE Lite) as well as a personal dosimeter device (GasAlert Extreme) which can be worn as additional personal protective equipment. An stainless steel extension wand was fabricated and included in the detection system for the MultiRAE Lite to allow for more remote sensing, and connects via the active pumping inlet of the sensor. As stated, the final results of this testing resulted in the production of two "kits" which can be used for the detection of HAN/AF-M315E and ADN/LMP-103s (ESC-245-FDG-003).

Detection↗

A Comprehensive X-ray Report on AT2019wey

The Galactic low-mass X-ray binary AT2019wey (ATLAS19bcxp, SRGAJ043520.9+552226, SRGEJ043523.3+552234, ZTF19acwrvzk) was discovered as a new optical transient in Dec 2019, and independently as an X-ray transient in Mar 2020. In this paper, we present comprehensive NICER, NuSTAR, Chandra, Swift, and MAXI observations of AT2019wey from ~1 year prior to the discovery to the end of September 2020. AT2019wey appeared as a ~ 1 mCrab source and stayed at this flux density for several months, displaying a hard X-ray spectrum that can be modeled as a power-law with photon index Γ ~ 1.8. In June 2020 it started to brighten and reached ~20 mCrab in ~2 months. The inclination of this system can be constrained to I ≲ 30° by modelling the reflection spectrum. Starting from late-August (~ 59082 MJD), AT2019wey entered into the hard-intermediate state (HIMS), and underwent a few week-long timescale outbursts, where the brightening in soft X-rays is correlated with the enhancement of a thermal component. Low-frequency quasi-periodic oscillation (QPO) was observed in the HIMS. We detect no pulsation and in timing analysis of the NICER and NuSTAR data. The X-ray states and power spectra of AT2019wey are discussed against the landscape of low-mass X-ray binaries.

Individual X-rays↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Galaxy Clusters Discovered via the Thermal Sunyaev-Zel’dovich Effect in the 500-square-degree SPTpol Survey

We present a catalog of 689 galaxy cluster candidates detected at significance ξ > 4 via their thermal Sunyaev-Zel’dovich (SZ) effect signature in 95 and 150 GHz data from the 500-square-degree SPTpol survey. We use optical and infrared data from the Dark Energy Camera and the Wide-field Infrared Survey Explorer (WISE) and Spitzer satellites, to confirm 544 of these candidates as clusters with ~ 94% purity. The sample has an approximately redshift-independent mass threshold at redshift z > 0.25. The confirmed sample spans 1.5 × 10 14 < M 500 c < 9 × 10 14 M ⊙ /h 70 and 0.03 < z ≲ 1.6 in mass and redshift, respectively, with a median mass of 2.5×10 14 M ⊙ /h 70 and median redshift z = 0.7; 21% of the confirmed clusters are at z > 1. We use external radio data from the Sydney University Molonglo Sky Survey (SUMSS) to estimate contamination to the SZ signal from synchrotron sources. The contamination reduces the recovered ξ by a median value of 0.032, or ~ 0.8% of the ξ = 4 threshold value, and ~ 7% of candidates have a predicted contamination greater than Δξ = 1. With the exception of a small number of systems (< 1%), an analysis of clusters detected in single-frequency 95 and 150 GHz data shows no significant contamination of the SZ signal by emission from dusty or synchrotron sources. This cluster sample, representing the deepest SZ-selected cluster sample to date, will be a key component in upcoming astrophysical and cosmological analyses of clusters. In addition to the cluster catalog, we also release the millimeter-wave maps and associated data products used to produce this sample. These maps have depths of 5.3 (11.7) µK CMB -arcmin at 150 (95) GHz and an effective angular resolution of 1. '2 (1. '7). The SPTpol products are available at https:// pole.uchicago.edu/public/data/sptpol_500d_clusters/index.html, and the NASA LAMBDA website. An interactive sky server with the SPTpol maps and Dark Energy Survey data release 2 images is also available at NCSA https://skyviewer.ncsa.illinois.edu.

79 ASTRONOMY AND ASTROPHYSICS↗

ROSAT observation program

In this annual progress report (November 1, 1993 to October 31, 1994), the geminga pulsar was observed by the ROSAT PSPC for 37,000 s in September 1993, in order to make a more detailed study than was previously possible of the pulse profile and two-component spectrum, and to do phase-resolved spectroscopy. This exposure was 2.5 times longer than the original discovery observation. In addition, a shorter 4,000 s exposure was made in October 1992, simultaneously with a GRO observation of Geminga, in order to verify the absolute phasing of the X-ray and gamma-ray peaks. We verified that the spectrum can be described as the sum of two black bodies, whose temperatures are 6 x 10(exp 5) K and 3 - 4 x 10(exp 6) K, with the latter covering 3 x 10(exp -5) the area of the former. The pulse profiles indicate that the intensity of the two emitting regions peak is approximately 90 deg out of phase in rotation, but that the temperatures are otherwise independent of phase. An improved estimate of the distance can be made from the cooler (larger) blackbody component, yielding d = 440 +/- 120 pc. Another program of this report was to obtain PSPC spectra of an important class of Seyfert galaxies which have narrow lines and stron permitted Fe II emission. Sometines called I Zw 1 objects, or narrow-line Seyfert 1s, they are crucial to our understanding of Seyfert classification and models of Seyfert unification. We observed four new objects and, in addition, obtained data on 17 more from the ROSAT archive. A third program combined PSPC and HRI observations of selected Seyfert galaxies which have unusual and variable spectra. The purpose was to disentangle diffuse X-ray emission from the nuclear source, in order to properly interpret the soft X-ray spectral shapes in terms of partial covering and/or warm-absorber models. The targets of the program are NGC 3516, NGC 3227, and NGC 7314. So far, we have only performed a dtailed analysis on NGC 3516. The fourth program of this report is the NGC 1672, the second brightest Seyfert galaxy and one or the original 'composite' Seyfert/starburst galaxies which have evidence for both Seyfert activity and H II regions in their optical spectra. It is one of the lowest luminosity Seyfert 2 galaxies that can be studied in detail.

Halpern, Jules P.↗

The Gandalf Staff: A Mobile Tool for Lunar Exploration (2nd year of development)

The Gandalf Staff is a mobile tool designed to be a flexible device supporting crewed and uncrewed operations on the lunar surface. The core of the device is a 24v battery with communications and data storage systems. Initial optional components supporting crewed Extra-Vehicular Activity (EVA) include a LiDAR and 360˚ camera. These provide 3D mapping of the traverse for documentation, and to aid future planning. The mapping also creates outreach opportunities for the public to “stand beside” the astronaut in Virtual Reality (VR). The staff provides external lighting for field site illumination in the south polar region low sun angle environment. Navigation instruments for crew position determination with Lunar Search and Rescue (LunaSAR) are also included. The staff itself can be used as a walking aid or as a splint for Incapacitated Crew Rescue (ICR). As a stand-alone device, the staff operates as a long duration untended science platform collecting environmental data and sending it to a lunar base station. The stand-alone mode requires connection to an auxiliary power source (e.g. solar array) and energy storage system (e.g. battery), so it could become an electrical recharging station. To make rapid progress in the 1st year, and also to demonstrate innovative project management techniques, NASA guided a private industry partner, T STAR, in leading Capstone Engineering student teams at Texas A&M University (TAMU) for proof-of-concept development and testing. These teams developed the power system and demonstrated successful integration of LiDAR, WiFi communications, and external lighting subsystems. Another industry team at Jacobs Technology prototyped a tripod to hold the staff upright. For the 2nd year (FY’22), NASA will again collaborate with partners to prototype enhanced power and lighting concepts. Year 2 will also add new capability for LunaSAR and geophysical science instrumentation using a heat probe. The heat probe is based upon Apollo heritage but modified to measure subsurface volatile ice regimes at the Artemis landing site. Components of the Gandalf Staff can be developed, tested, and deployed independently, or on the integrated staff, rovers, or utility trailers. The project supports crew safety, lunar sample curation, mission science, and public outreach goals of NASA. PLAIN TEST SUMMARY: Gandalf Staff is a 24v battery powered mobile tool for the lunar surface supporting crewed geologic field site exploration, or as a stand-alone science platform. As a tool assisting astronauts conducting field geology, the Gandalf Staff provides external lighting to illuminate shadowed regions on the surface. It also documents the process of collecting rocks and dust samples using a LiDAR (laser range instrument) and cameras. The staff provides a beacon for emergency location of astronauts and augments communications when the astronauts are blocked by large boulders. As a standalone science platform, the Gandalf Staff provides a power system for instruments and sensors to measure the lunar environment over long periods of time. The staff gathers data and sends the results to a lunar base station for analysis.

External Lighting↗

Assessment of the NPP VIIRS RVS for the Thermal Emissive Bands Using the First Pitch Maneuver Observations

The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor carried on Suomi NPP (National Polar-orbiting Partnership) satellite (http://npp.gsfc.nasa.gov/viirs.html) (launched in October 2011). VIIRS sensor design draws on heritage instruments including AVHRR, OLS, SeaWiFS and MODIS. It has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) port for background subtraction. These on-board calibrators are located at fixed scan angles. The VIIRS response versus scan angle (RVS) was characterized prelaunch in lab ambient conditions and is currently used to characterize the on-orbit response for all scan angles relative to the calibrator scan angle (SD for RSB and blackbody for TEB). Since the RVS is vitally important to the quality of calibrated radiance products, several independent studies were performed to analyze the prelaunch RVS measurement data. A spacecraft level pitch maneuver was scheduled during the first three months of intensive Cal/Val. The NPP pitch maneuver provided a rare opportunity for VIIRS to make observations of deep space over the entire range of scan angles, which can be used to characterize the TEB RVS. This study will provide our analysis of the pitch maneuver data and assessment of the derived TEB RVS. A comparison between the RVS determined by the pitch maneuver observations and prelaunch lab tests will be conducted for each band, detector, and half angle mirror (HAM) side

Wu, A.↗