CRADA Number NFE-19-07847 with MantaPoole Technologies (CRADA Final Report)

As the world becomes more automated, smart and autonomous systems that utilize advanced 3D machine vision are becoming ever more prevalent. To function autonomously, these smart machines need to be able to identify the “what” and “where” of their application by capturing color and depth information. The color information provides the needed contrast information to identify the “what” of a scene while the depth information allows the smart machine to identify “where” an object in a 3D environment is. To capture both the color and depth information using only a single sensor, MantaPoole Technologies (MPT) is developing a new type of 3D light field camera. The approach leverages MPT’s active micro-optics technology which when aligned and placed over an imaging detector are designed to act as an advanced optical filter that controls the direction of light that reaches the underlying pixels.

47 OTHER INSTRUMENTATION↗

NPFTURBULENCE: Fast Response Temperature by Airborne Measurements

The original data were collected during the field campaign of the “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence; https://www.arm.gov/publications/programdocs/doe-sc-arm-25-004.pdf ) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration and size distribution. The current dataset presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current dataset were the fine wire thermocouple probe, Pitot-static system (part of the UAS control), and infrared gas analyzer sensor for H2O and CO2 (LI-840A). All parameters used in the temperature calculations (static and dynamic pressure, absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature↗

System and methods for deploying payloads

Embodiments of the present invention include systems for launching primary or secondary payloads or actuating other launch vehicle or payload or instrumentation devices. The system includes an adapter assembly and at least one sequencer mounted to the adapter assembly. The sequencer includes: controller boards, each of the controller boards having a controller for controlling deployment of the payloads and data files; output ports coupled to the controller boards and configured to transmit signals from the controller boards to dispensers therethrough, deployment mechanisms containing the payloads, the adapter assembly having channels for accommodating the dispensers; and a detector coupled to the controller boards and adapted to detect an external signal and, in response to the external signal, to send an initiation signal to the controller boards. The system also includes at least one power supply coupled to the sequencer and adapted to provide an electrical power to the sequencer.

42 ENGINEERING↗

Instrument for in situ hard x-ray nanobeam characterization during epitaxial crystallization and materials transformations

Solid-phase epitaxy (SPE) and other three-dimensional epitaxial crystallization processes pose challenging structural and chemical characterization problems. The concentration of defects, the spatial distribution of elastic strain, and the chemical state of ions each vary with nanoscale characteristic length scales and depend sensitively on the gas environment and elastic boundary conditions during growth. The lateral or three-dimensional propagation of crystalline interfaces in SPE has nanoscale or submicrometer characteristic distances during typical crystallization times. Here, an in situ synchrotron hard x-ray instrument allows these features to be studied during deposition and crystallization using diffraction, resonant scattering, nanobeam and coherent diffraction imaging, and reflectivity. The instrument incorporates a compact deposition system allowing the use of short-working-distance x-ray focusing optics. Layers are deposited using radio-frequency magnetron sputtering and evaporation sources. The deposition system provides control of the gas atmosphere and sample temperature. The sample is positioned using a stable mechanical design to minimize vibration and drift and employs precise translation stages to enable nanobeam experiments. Results of in situ x-ray characterization of the amorphous thin film deposition process for a SrTiO 3 /BaTiO 3 multilayer illustrate implementation of this instrument.

47 OTHER INSTRUMENTATION↗

Stabilization of Ultrasmall Platinum Nanoparticles by Nitrogen-Doped Carbon: Implications for Catalysis and Electrocatalysis

Heterogeneous materials comprising platinum nanoparticles on carbon supports have numerous applications including fuel cell electrodes and heterogeneous catalysts. The effective application of these materials for fuel cells and catalysis will be greatly advanced by the ability to control the oxidation and sintering of the nanoparticles by modifications of the carbon support. One attempt of such control has been doping carbon supports with nitrogen. Here, in this work, a cutting-edge, high-sensitivity, in situ XRD instrument, which allows observation of ultrasmall Pt nanoparticles, has been combined with in situ XPS to provide unprecedented clarity in the characterization of supported Pt nanoparticles in oxidizing and high-temperature environments. On a nitrogen-doped carbon support derived from poly-phenylporphyrin, Pt nanoparticles show increased stability to oxidation and thermal sintering. The enhanced Pt–support interaction arising from the N dopant versus the N-free carbon is manifested by (1) decreased initial Pt particle sizes, (2) small particle size at higher surface densities, (3) increased resistance of Pt nanoparticles to oxidation, (4) increased electron binding energy of Pt0, and (5) increased resistance of Pt nanoparticles to sintering. It is expected that the higher stability of Pt on NC will be manifested in higher activity in fuel cells and high-temperature catalytic reactions.

catalytic reactions↗

Media Robustness and Scalability of Phosphate Regulated Promoters Useful for Two-Stage Autoinduction in E. coli

A key challenge in synthetic biology is the successful utilization of characterized parts, such as promoters, in different biological contexts. We report the evaluation of the media robustness of a small library of E. coli PhoB regulated promoters that enable heterologous protein production in two-stage cultures. Expression levels were measured both in a rich Autoinduction Broth as well as a minimal mineral salts media. Expression was both media and promoter dependent. Of the 16 promoters tested, 4 were identified to have tightly controlled expression, which was also robust to media formulation. Improved promoter robustness led to more predictable scale up and consistent expression in instrumented bioreactors. Furthermore, this subset of PhoB activated promoters, useful for two-stage autoinduction, highlights the impact of the environment on the performance of biological parts and the importance of robustness testing in synthetic biology.

59 BASIC BIOLOGICAL SCIENCES↗

COMPASS-FME Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) Experiment Level 1 Sensor Data v1-2

This is the version 1-2 Level 1 (L1) data release for COMPASS-FME environmental sensors located at our Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental site. This manipulative, ecosystem-scale TEMPEST experiment addresses the potential for freshwater and estuarine-water disturbance events to alter tree function, species composition, and ecosystem processes in a deciduous coastal forest in MD, USA. The experiment uses a large-unit (2000 m2), un-replicated experimental design, with three 50 m × 40 m plots serving as control, freshwater, and estuarine-water treatments.L1 data are close to raw, but are units-transformed and have out-of-instrument-bounds and out-of-service flags added. Duplicates and missing data are removed but otherwise these data are not filtered, and have not been subject to any additional algorithmic or human QA/QC. Any scientific analyses of L1 data should be performed with care. **This dataset will be updated quarterly with new data for the duration of the project**This dataset includes:- An overall dataset README file that describes the current version, gives citation and contact information, etc.- Site- and year-specific folders, each holding up to 12 CSV (comma separated value) data files for each site and plot in that year.- Metadata files within each site-year folder provide full information on data units, expected ranges, contact information, detailed flood times, as well as a general description of the site.- Environmental sensor types that appear in the data files include weather (ClimaVUE50, CS, RM Young, and LI instruments in the graphs below); soil conditions (TEROS12); soil redox state (Redox); groundwater variables (AquaTROLL200 and AquaTROLL600); open water sondes (Exo); tree sap velocity (Sapflow); and system voltage and state (Datalogger). Data are normally logged every 15 minutes.Please see v1-2 TEMPEST L1 Sensor Package Quick Start.pdf for detailed information on data package structure, temporal coverage, and versioning.The TEMPEST flood events occurred on the following dates. They lasted for ~10 hours each day and delivered ~80,000 gallons to each plot; many data streams are available at 1 or 5 minute frequency during these periods.* Tests: Aug 25 (fresh plot) and Sep 9 (salt plot), 2021* TEMPEST 1: June 22, 2022* TEMPEST 2: June 6-7, 2023* TEMPEST 3: June 11-13, 2024

54 ENVIRONMENTAL SCIENCES↗

Evaluation of the Nanometrics Centaur Digitizer

Sandia National Laboratories has tested and evaluated a new digitizer, the Centaur, manufactured by Nanometrics, Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as power, sensitivity, self-noise, dynamic range, system noise, modified noise power ration, relative transfer function, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Centaur provides six channels of 24 bit digitization, three of which may be transmitted utilizing CD1.1 protocol.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Q330M+, manufactured by Quanterra, a division of Kinemetrics Inc. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, input impedance, power consumption, self noise, dynamic range, system noise, relative transfer function, analog bandwidth, modified noise power ratio, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Q330M+ provides six channels of 24 bit digitization, all of which may be transmitted utilizing CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guralp Affinity Digitizer Evaluation

Sandia National Laboratories has tested and evaluated a new digitizer, the Affinity, manufactured by Guralp Systems. This digitizer is used to record sensor output for seismic and infrasound monitoring applications. The purpose of the digitizer evaluation was to measure the performance characteristics in such areas as sensitivity, power, self-noise, dynamic range, system noise, relative transfer function, modified noise power ratio, analog bandwidth, harmonic distortion, common mode, cross talk, timing tag accuracy and timing drift. The Affinity provides eight, rather the typical six, channels of 24 bit high sample rate digitization, all of which may be transmitted utilizing the CD1.1 protocol, at multiple sample rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Auto Procedure Parsing: A Natural Language Processing Approach

Nuclear Power Plant (NPP) operating procedure is “a set of rules that describes how actions on the plant should be made if a certain system goal should be accomplished. U.S. NPPs use paper-based procedures (PBPs). PBPs are difficult to use. Common errors with PBPs are: following the wrong procedure, omit a step etc. Computer based procedures (CPBs) offer great improvement in ensuring plant safety. Some studies rely on experienced operators to understand the procedure content and then reorganize the procedure with digitally executable capabilities. Other studies utilize the procedure format to design rules to extract information from the operating procedures. Existing studies in procedure parsing are manual, laborious and extract limited information. This study aims to automatically extract critical information from operating procedures for generating computer interpretable representation of procedures. Such representation can further be used for automatic dynamic human reliability analysis and CPB design etc.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

FOCAL Campaign II/III: Applying Active Hull Controls Using Tuned-mass Dampers/Hull Flexibility and Internal Loads

Campaign II and III of the Floating Offshore-wind Controls Advanced Laboratory Experimental Program (FOCAL) aimed to generate a dataset enabling the validation of the performance and loads of a scaled hull, with and without structural hull control. The floating platform was subjected to a variety of wave environments and controlled using tuned-mass dampers (TMDs) tuned to two of the systems natural frequencies (Platform Pitch and Tower-bending). The floating platform is fully instrumented to record a variety of parameters in real time such as platform dynamics, accelerations, and loads at different points in the structure. The test data considered was generated at the University of Maine's Harold Alfond Wind and Wave (W2) testing facility. This testing was focused only on validation of wave loading, and wind conditions were not considered. As such the platform does not support a working turbine, and instead supports a structure designed to have the same mass properties as the 1:70 IEA 15MW Reference turbine. The Load Cases (LC) considered in this testing campaign are as follows: LC 1.X - Platform Static Offset (TMD off); LC 2.X - Platform Free-decays (TMD off); LC 3.X - Wave Cases (Regular Wave, Irregular Wave, Pink Noise Wave) with and without TMDs active. Detailed properties on the model system are found in the following reference: Lenfest E., Floating Offshore-wind Controls Advanced Laboratory (FOCAL) Experimental Program - Campaigns 2 and 3: 1:70 Model-scale Testing of the IEA-Wind 15MW Reference Turbine and the VolturnUS-S Hull. UMaine ASCC Report Number 23-56-1183.

17 WIND ENERGY↗

Ultrafast Error-bounded Lossy Compression for Scientific Datasets

Today's scientific high-performance computing applications and advanced instruments are producing vast volumes of data across a wide range of domains, which impose a serious burden on data transfer and storage. Error-bounded lossy compression has been developed and widely used in the scientific community because it not only can significantly reduce the data volumes but also can strictly control the data distortion based on the user-specified error bound. Existing lossy compressors, however, cannot offer ultrafast compression speed, which is highly demanded by numerous applications or use cases (such as in-memory compression and online instrument data compression). In this paper, we propose a novel ultrafast error-bounded lossy compressor that can obtain fairly high compression performance on both CPUs and GPUs and with reasonably high compression ratios. The key contributions are threefold. (1) We propose a generic error-bounded lossy compression framework---called SZx---that achieves ultrafast performance through its novel design comprising only lightweight operations such as bitwise and addition/subtraction operations, while still keeping a high compression ratio. (2) We implement SZx on both CPUs and GPUs and optimize the performance according to their architectures. (3) We perform a comprehensive evaluation with six real-world production-level scientific datasets on both CPUs and GPUs. Experiments show that SZx is 2~16x faster than the second-fastest existing error-bounded lossy compressor (either SZ or ZFP) on CPUs and GPUs, with respect to both compression and decompression.

Yu, Xiaodong↗

Optimal Traffic Signal Control Using Priority Metric Based on Real-Time Measured Traffic Information

Optimizing traffic control systems at traffic intersections can reduce network-wide fuel consumption as well as improve traffic flow. While traffic signals have conventionally been controlled based on predetermined schedules, various adaptive control systems have been developed recently using advanced sensors such as cameras, radars, and LiDARs. By utilizing rich traffic information enabled by the advanced sensors, more efficient or optimal traffic signal control is possible in response to varying traffic conditions. This paper proposes an optimal traffic signal control method to minimize network-wide fuel consumption utilizing real-time traffic information provided by advanced sensors. This new method employs a priority metric calculated by a weighted sum of various factors, including the total number of vehicles, total vehicle speed, vehicle waiting time, and road preference. Genetic Algorithm (GA) is used as a global optimization method to determine the optimal weights in the priority metric. In order to evaluate the effectiveness of the proposed method, a traffic simulation model is developed in a high-fidelity traffic simulation environment called SUMO, based on a real-world traffic network. The traffic flow within this model is simulated using actual measured traffic data from the traffic network, enabling a comprehensive assessment of the novel optimal traffic signal control method in realistic conditions. The simulation results show that the proposed priority metric-based real-time traffic signal control algorithm can significantly reduce network-wide fuel consumption compared to the conventional fixed-time control and coordinated actuated control methods that are currently used in the modeled network. Additionally, incorporating truck priority in the priority metric leads to further improvements in fuel consumption reduction.

47 OTHER INSTRUMENTATION↗

Assessment of Acoustic Sensor Application to Structural Health Monitoring of Reactor Components

The objectives of SHM of advanced fission reactors include the following: (1) Maintain safe, reliable, and efficient operation of structures, systems, and components in accordance with design intent; (3) Reduce cost; (4) Improve the comprehensive life management of structures, systems, and components; and (5) Extend the operational life of a power system through retirement for cause. Advanced reactor designs currently being considered are expected to operate at higher temperatures than light water-cooled reactors and to support missions beyond baseload electricity generation. Methods to monitor and detect for these mechanisms will require structural health monitoring (SHM) techniques, with ultrasonic methods an ideal candidate given their widespread use for NDE. This document summarized the state of technology for ultrasonic technologies, as part of an assessment of technology gaps and needed research. The great majority of sensor development to date addresses elevated temperatures and radiation tolerance, and more work is needed in both areas. Little data exists regarding corrosion effects of advanced coolants on sensor materials and couplants. Of high importance is the need for ARDs and regulatory bodies to engage and define what level of SHM is needed for autonomous or semi-autonomous control of reactors.