Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser amplifiers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

System Level TVAC Functional Testing for the Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) Payload Destined for the International Space Station

The Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) payload will be launched to the International Space Station (ISS) in 2023. ILLUMA-T is an optical communications payload that will make the ISS the first space-based user to communicate with NASA’s Laser Communications Relay Demonstration (LCRD). The system will support all-optical forward links up to 150 Mbps and return links up to 1 Gbps. The payload recently underwent system level Thermal VACuum (TVAC) functional testing at MIT Lincoln Laboratory. We present an overview of the payload’s TVAC functional tests and results.

laser communications↗

Surface smoothing for laser powder-bed Ti-6Al-4V by a transient liquid phase

Surface roughness is the primary driver of fatigue for additively manufactured metals. To address surface roughness, this work introduces a new method to smooth features beyond line-of-sight without material removal. The method applies a coating that triggers local surface remelting by activating a eutectic reaction during heat treatment. The associated liquid phase then wets and isothermally solidifies into a smoother surface. For Ti-6Al-4V fabricated with laser powder bed fusion, samples with and without TLP smoothing (using a Cu coating) were characterized with a suite of techniques, including mechanical testing, electron backscatter diffraction, synchrotron X-ray tomography, and fractography. TLP smoothing reduced surface roughness by 80% and amplified compressive residual stress at the surface by about 50%. With statistically equivalent virtual microstructures, crystal plasticity scrutinized the roles of phases, porosity, and surface roughness. Although the tensile strain-to-failure was reduced to 1% strain, the TLP smoothing process increased high-cycle fatigue strength by about 20% compared to control samples, pointing to future opportunities to optimize the new process through various coating compositions and heat treatment schedules. Overall, this work establishes a new paradigm for treating surfaces of materials for smoothness and compressive residual stress.

Additive manufacturing↗

Operational Parameters, Considerations, and Design Decisions for Resource-Constrained Ion Trap Mass Spectrometers

Mass spectrometers are increasingly finding applications in new and unique areas, often in situations where key operational resources (i.e. power, weight and size) are limited. One such example is the Mars Organic Molecule Analyzer (MOMA). This instrument is a joint venture between NASA and the European Space Agency (ESA) to develop an ion trap mass spectrometer for chemical analysis on Mars. The constraints on such an instrument are significant as are the performance requirements. While the ideal operating parameters for an ion trap are generally well characterized, methods to maintain analytical performance with limited power and system weight need to be investigated and tested. Methods Experiments have been performed on two custom ion trap mass spectrometers developed as prototypes for the MOMA instrument. This hardware consists of quadrupole ion trap electrodes that are 70% the size of common commercial instrumentation. The trapping RF voltage is created with a custom tank circuit that can be tuned over a range of RF frequencies and is driven using laboratory supplies and amplifiers. The entire instrument is controlled with custom Lab VIEW software that allows a high degree of flexibility in the definition of the scan function defining the ion trap experiment. Ions are typically generated via an internal electron ionization source, however, a laser desorption source is also in development for analysis of larger intact molecules. Preliminary Data The main goals in this work have been to reduce the power required to generate the radio frequency trapping field used in an ion trap mass spectrometer. Generally minimizing the power will also reduce the volume and mass of the electronics to support the instrument. In order to achieve optimum performance, commercial instruments typically utilize RF frequencies in the 1 MHz range. Without much concern for power usage, they simply generate the voltage required to access the mass range of interest. In order to reduce the required RF voltage (and power), operation of the ion trap at lower RF frequencies has been investigated. Surprisingly, the performance of the instrument has only been slightly degraded at RF frequencies all the way down to 500 kHz. Mass resolution is relatively stable to this point and depending on the resonant ejection point used, the peak intensity is also quite stable. To date only masses up to m/z 200 have been fully investigated, however, additional studies are planned to verify the performance with higher mass ions. The lower frequency and voltage should reduce the pseudo potential well depth, eventually affecting the trapping efficiency of the instrument -- effect that could manifest itself in significantly limiting the mass range of trapped ions. Other methods to reduce the RF power while maintaining analytical performance are also under investigation. This includes ion ejection at lower q(sub z) values to access a given mass with a lower RF voltage. The loss of mass resolution at lower q(sub eject) points has been measured and current work is underway to leverage scan speed and the use of non-linear resonances in order to counter this trend. The overall trap performance under this range of operating conditions will be presented with a goal of identifying what trade-offs are acceptable.

Danell, Ryan M.↗

Self-amplified optical pattern recognition system

A self amplifying optical pattern recognizer includes a geometric system configuration similar to that of a Vander Lugt holographic matched filter configuration with a photorefractive crystal specifically oriented with respect to the input beams. An extraordinarily polarized, spherically converging object image beam is formed by laser illumination of an input object image and applied through a photorefractive crystal, such as a barium titanite (BaTiO.sub.3) crystal. A volume or thin-film dif ORIGIN OF THE INVENTION The invention described herein was made in the performance of work under a NASA contract, and is subject to the provisions of Public Law 96-517 (35 USC 202) in which the Contractor has elected to retain title.

Liu, Hua-Kuang↗

Experimental Results from Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) Program

The National Aeronautics and Space Administration’s (NASA) Integrated LCRD Low-Earth Orbit (LEO) User Modem and Amplifier Terminal (ILLUMA-T) payload was launched and installed on the International Space Station’s (ISS) Japanese Experiment Module - Exposed Facility (JEM-EF) in November 2023. ILLUMA-T was the first space-based user to communicate with NASA’s Laser Communications Relay Demonstration (LCRD) using free space optical communication to transfer data from the ISS at return rates to Earth of up to 1.244 Gbps and forward rates from Earth of up to 155 Mbps. A 6-month long Experiments Program on ILLUMA-T concluded in June 2024, after which the payload was removed from the ISS and is currently de-orbiting. The Experiments Program was carefully designed to understand and characterize the Pointing, Acquisition, and Track (PAT) process with the new Modular, Agile, Scalable Optical Terminal (MAScOT), optical modem performance, and end-to-end relay performance.

ISS↗

Optical Phase Recovery and Locking in a PPM Laser Communication Link

Free-space optical communication holds great promise for future space missions requiring high data rates. For data communication in deep space, the current architecture employs pulse position modulation (PPM). In this scheme, the light is transmitted and detected as pulses within an array of time slots. While the PPM method is efficient for data transmission, the phase of the laser light is not utilized. The phase coherence of a PPM optical signal has been investigated with the goal of developing a new laser communication and ranging scheme that utilizes optical coherence within the established PPM architecture and photon-counting detection (PCD). Experimental measurements of a PPM modulated optical signal were conducted, and modeling code was developed to generate random PPM signals and simulate spectra via FFT (Fast Fourier Transform) analysis. The experimental results show very good agreement with the simulations and confirm that coherence is preserved despite modulation with high extinction ratios and very low duty cycles. A real-time technique has been developed to recover the phase information through the mixing of a PPM signal with a frequency-shifted local oscillator (LO). This mixed signal is amplified, filtered, and integrated to generate a voltage proportional to the phase of the modulated signal. By choosing an appropriate time constant for integration, one can maintain a phase lock despite long dark times between consecutive pulses with low duty cycle. A proof-of-principle demonstration was first achieved with an RF-based PPM signal and test setup. With the same principle method, an optical carrier within a PPM modulated laser beam could also be tracked and recovered. A reference laser was phase-locked to an independent pulsed laser signal with low-duty-cycle pseudo-random PPM codes. In this way, the drifting carrier frequency in the primary laser source is tracked via its phase change in the mixed beat note, while the corresponding voltage feedback maintains the phase lock between the two laser sources. The novelty and key significance of this work is that the carrier phase information can be harnessed within an optical communication link based on PPM-PCD architecture. This technology development could lead to quantum-limited efficient performance within the communication link itself, as well as enable high-resolution optical tracking capabilities for planetary science and spacecraft navigation.

Aveline, David C.↗

Experimental Passive-State Preparation for Continuous-Variable Quantum Communications

In the Gaussian-modulated coherent state quantum key distribution (QKD) protocol, the sender first generates Gaussian-distributed random numbers and then encodes them on weak laser pulses actively by performing amplitude and phase modulations. Recently, an equivalent passive QKD scheme has been proposed by exploring the intrinsic field fluctuations of a thermal source [B. Qi, P. G. Evans, and W. P. Grice, Phys. Rev. A 97, 012317 (2018)]. This passive QKD scheme is especially appealing for chip-scale implementation since no active modulation is required. In this paper, we conduct an experimental study of the passively encoded QKD scheme using an off-the-shelf amplified spontaneous emission source operated in continuous-wave mode. Our results show that the excess noise introduced by the passive state preparation scheme can be effectively suppressed by applying optical attenuation and a secure key can be generated over metro-area distances.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Solid State Laser Materials for Application in Lasers for Atmospheric Ozone and Water Vapor Sensing

We have grown neodymium doped mixed apatite crystals, (Sr(x)Ba(l-x)5(PO4)3F, Sr5(P(1-x)V(x)O4)3F, and Ba5(P(1-x)V(x)O4)3F, and spectroscopically studied them as potential gain media for a laser source for atmospheric water sensing operating at 944.11 nm0. We conclude that an appropriate apatite host material for a 944.11 nm laser should be a mixture of Sr5(PO4)3F with a small fraction of Ba5(PO4)3F. The precise wavelength tuning around 944.11 nm can be accomplished by varying the host composition, temperature, and threshold population inversion. In apatite crystals of mixed composition, the Amplified Spontaneous Emission (ASE) loss at 1.06 microns is predicted to be significantly smaller than that in the end members.

Noginov, Makhail A.↗

Directly solar-pumped iodine laser for beamed power transmission in space

A new approach for development of a 50-kW directly solar-pumped iodine laser (DSPIL) system as a space-based power station was made using a confocal unstable resonator (CUR). The CUR-based DSPIL has advantages, such as performance enhancement, reduction of total mass, and simplicity which alleviates the complexities inherent in the previous system, master oscillator/power amplifier (MOPA) configurations. In this design, a single CUR-based DSPIL with 50-kW output power was defined and compared to the MOPA-based DSPIL. Integration of multiple modules for power requirements more than 50-kW is physically and structurally a sound approach as compared to building a single large system. An integrated system of multiple modules can respond to various mission power requirements by combining and aiming the coherent beams at the user's receiver.

Choi, S. H.↗

Ground Demonstration of Planetary Gas Lidar Based on Optical Parametric Amplifier

We report on the development effort of a nanosecond-pulsed optical parametric amplifier (OPA) for remote trace gas measurements for Mars and Earth. The OPA output has high spectral purity and is widely tunable both at near-infrared and mid-infrared wavelengths, with an optical-optica1 conversion efficiency of up to approx 39 %. Using this laser source, we demonstrated open-path measurements of CH4 (3291 nm and 1651 nm), CO2 (1573 nm), H2O (1652 nm), and CO (4764 nm) on the ground. The simplicity, tunability. and power scalability of the OPA make it a strong candidate for general planetary lidar instruments, which will offer important information on the origins of the planet's geology, atmosphere, and potential for biology,

Numata, Kenji↗

Design of a near-IR coherent lidar for high spatial and velocity resolution wind measurement

A coherent Doppler lidar based on a CW diode-pumped, injection seeded, Th:YAG laser operating at approx. 2.02 microns is currently under development. This system is optimized for measurements of boundary layer winds with high spatial, temporal, and velocity resolution. Initially, the system will run alongside a new high repetition rate (5-10 kHz) CO2 mini-Master Oscillator Power Amplifier (mini-MOPA) Doppler lidar, which will provide simultaneous range-resolved Differential Absorption Lidar (DIAL) water vapor measurements. Water vapor DIAL operation of the 2 micron system is being considered as a future option. The anticipated specifications and the preliminary design are discussed.

Grund, Christian J.↗

Investigation of hard targets for calibration of a coherent Doppler lidar system

The bihemispherical reflectance has been measured for a diffuse gold surface the same as the coating on the integrating sphere, flowers of sulfur, sandblasted aluminum, and 120 grade aluminum oxide sandpaper. The sandpaper measurements indicate that materials with low reflectance cannot be measured until more sensitive detection techniques are found. The sphere had to be used without a detector baffle so an unusual geometry was needed that led to a loss of intensity. Further, it is estimated that some first-strike light entered the detector and the readings could be 1 to 1.5% too low. A limited number of normal incident directional-hemispherical reflectance measurements were made on aluminum and sandpaper. Several recommendations are made: (1) the proper baffle placement; (2) improve lock-in detection using a PAR lock-in amplifier or the heterodyne technique; (3) modification of the sphere so the sample may be mounted at the cell center on a graduate, rotatable table for measurement of directional-hemispherical reflectance; (4) the purchase of additional diffuse gold samples with coatings like the sphere; and (5) better laser temperature control to improve intensity stability.

Anderson, Richard↗

Ultrasensitive Label-free Electronic Chip for DNA Analysis Using Carbon Nanotube Nanoelectrode Arrays

There is a strong need for faster, cheaper, and simpler methods for nucleic acid analysis in today s clinical tests. Nanotechnologies can potentially provide solutions to these requirements by integrating nanomaterials with biofunctionalities. Dramatic improvement in the sensitivity and multiplexing can be achieved through the high-degree miniaturization. Here, we present our study in the development of an ultrasensitive label-free electronic chip for DNA/RNA analysis based on carbon nanotube nanoelectrode arrays. A reliable nanoelectrode array based on vertically aligned multi-walled carbon nanotubes (MWNTs) embedded in a SiO2 matrix is fabricated using a bottom-up approach. Characteristic nanoelectrode behavior is observed with a low-density MWNT nanoelectrode array in measuring both the bulk and surface immobilized redox species. The open-end of MWNTs are found to present similar properties as graphite edge-plane electrodes, with a wide potential window, flexible chemical functionalities, and good biocompatibility. A BRCA1 related oligonucleotide probe with 18 bases is covalently functionalized at the open ends of the MWNTs and specifically hybridized with an oligonucleotide target as well as a PCR amplicon. The guanine bases in the target molecules are employed as the signal moieties for the electrochemical measurements. Ru(bpy)3(2+) mediator is used to further amplify the guanine oxidation signal. This technique has been employed for direct electrochemical detection of label-free PCR amplicon through specific hybridization with the BRCAl probe. The detection limit is estimated to be less than approximately 1000 DNA molecules, approaching the limit of the sensitivity by laser-based fluorescence techniques in DNA microarray. This system provides a general electronic platform for rapid molecular diagnostics in applications requiring ultrahigh sensitivity, high-degree of miniaturization, simple sample preparation, and low- cost operation.

Li, Jun↗

RF Differential Phase Noise Measurements of the LISA TRL-6 Laser

RF differential phase noise (RF modulation sideband phase noise): phase jitter between the optical sideband generated from phase modulation and the optical carrier. Clock noise information of each space craft (s/c) is imprinted on the RF modulation sidebands and transferred between s/c through beating of the sidebands. Therefore, it is necessary to manage the RF modulation phase noise as light propagates from the phase modulator to the power amplifier delivery fiber.

Phase noise↗

Simulations of Laser Experiments to Study the Origin of Cosmic Magnetic Fields

Magnetic fields are ubiquitous in the universe; however, their origin is not fully understood. Cosmologists and astrophysicists have proposed a variety of ways in which small seed magnetic fields could be created. It is widely thought that the much larger values of the cosmic magnetic fields that we observe are a result of the amplification of these seed fields by the nonlinear turbulent dynamo mechanism. Such a mechanism had not yet been demonstrated in a controlled laboratory environment. We conceived experiments designed to demonstrate and study the nonlinear turbulent dynamo mechanism in the laboratory. These experiments characterize the distribution of turbulent energy among the velocity, magnetic field, and density fluctuations, providing a comprehensive picture of the energy cascade in a magnetized, turbulent plasma. The experiments build on the pathfinder experiments we have conducted on the Vulcan laser at the Rutherford-Appleton Laboratory in the UK and the OMEGA laser at Laboratory for Laser Energetics at Rochester. They utilize the high-intensity lasers at the Omega Laser Facility, the National Ignition Facility (NIF) at LLNL and the Laser Megajoule (LMJ) Facility in France – the largest laser facilities in the world. The goal of this project was to design and model the highly demanding experiments through simulation campaigns using FLASH, a highly capable radiation-MHD code we have developed, and large-scale 3D simulations on the Mira supercomputer at ANL. The simulations were vital to ensuring the experiments achieve the strong turbulence and large magnetic Reynolds numbers required for the nonlinear turbulent dynamo mechanism to operate. The simulations were also critical to determining when to fire the diagnostics, since the experiments last tens of nanoseconds but the signals of the strongly amplified magnetic fields last only a few nanoseconds. Finally, high-fidelity, validated FLASH simulations were crucial to interpreting the results of the experiments. By combining theory, experiments, and simulations, we were able to succeed in demonstrating and characterizing the nonlinear turbulent dynamo mechanism. The effort leveraged (1) the emergence of the Flash Center for Computational Science as a leader in numerical modeling of academic High Energy Density Physics (HEDP) experiments; (2) the FLASH code, which has been developed by the Flash Center and is a leadership-class, multi- physics, publicly available community code that has been applied successfully in many laser-driven experiments; (3) the expertise acquired through pathfinder experiments we performed on the Vulcan laser at the Rutherford-Appleton Laboratory in the UK and on the Omega laser facility; (4) the experience we have gained in designing and interpreting these experiments using validated simulations done with FLASH; and (5) the close collaborations we have established with outstanding experimental groups in the US and abroad. The broader impacts of the project are two-fold: (1) the work furthered the transformation of the academic community’s ability to design and analyze HEDP experiments at large laser facilities that is happening through the availability of FLASH and its widespread adoption by the academic community – a community that previously had had limited access to open and validated hydro/MHD simulation tools for HEDP experiments; and (2) the work trained young scientists to design and interpret HEDP experiments using validated simulations – a critical national need.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

JPL self-pulsed laser surface measurement system development

Distances from a fixed reference or scan postion to several locations on the surface of an antenna reflector can be measured by using a self pulsed laser ranging system. Processing the information thus obtained is used to define the shape of the surface upon which antenna operational efficiency is directly dependent. Operation of the system consists of initiating a pulse from the laser emitter which is pointed at the scan mirror. The emitted pulse strikes the scan mirror, is reflected and sent to one of several targets on the surface of the antenna. Upon reflection from the target, the pulse returns to a detector via the scan mirror. The detected pulse is amplified and used to trigger the next emitted pulse. After the first pulse is emitted, received and used to trigger another pulse the process becomes repetitive with a repitition rate uniquely determined by the distance traveled to the target and back. A measure of the repetition rate or frequency thus created provides the means required for determining range since the total distance traveled is inversely proportional to the frequency.

Berdahl, M.↗