Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC DIPOLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Negative Muon Count for the FNAL Muon g-2 Experiment

The primary goal of the FNAL Muon g-2 Experiment, located in Batavia, IL, USA, is to measure the anomalous magnetic dipole moment, a μ = (g-2)/2, of a muon to a precision of 0.14 ppm. Initial results from the experiment confirm a discrepancy between the experimental value of the muon anomaly compared with the theoretical value first discovered by the Brookhaven Muon g-2 Experiment in 2001. This discrepancy hints at new physics. However, running the experiment with negative muons is essential in order to verify the experimental value of the muon anomaly. As neither experiments nor simulation studies pertaining to the muon anomaly have been performed with negative muons, the goal of this work is to estimate the rates of negative muons arriving at the FNAL Muon g-2 experiment so that scientists can estimate the time required to run the experiment with negative muons. In order to do this, we performed several simulations of the Muon Campus, which delivers muons to the FNAL Muon g-2 Experiment, using the G4Beamline v. 3.06 at the National Energy Research Computing Center. We performed separate simulations for different sections of the muon campus, and simulations were repeated twice, once for negative muons and once for positive muons. An initial 10 9 protons were shot on target for both the negative and positive muon simulations. We found that the rate of negative muons arriving at the experiment was 0.549 times the rate of positive muons arriving at the experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Voltage Multiplier: A New, Compact Design using SiC High Frequency MOSFETs

In this report, power supply models for particle accelerators are examined and electrical equivalent model for a high-voltage multiplier power supply is developed. The ultimate goal is to provide the blue prints for the realization of real world models to power both the electrical and magnetic dipoles that make up the key components of the typical particle accelerator assembly.

43 PARTICLE ACCELERATORS↗

EXPERIMENTAL DEMONSTRATION OF A STRAIGHT-MERGER BEAMLINE

Beamlines capable of merging beams with different energies are critical to many applications related to advanced accelerator concepts and energy recovery linacs (ERLs). A straight merger system composed of a transverse deflecting cavity with a superimposed dipole magnet was proposed and recently tested at the Argonne Wakefield Accelerator. This paper reports on the experimental demonstration of the concept along with detailed beam dynamics investigations of the merger concept and its ability to conserve the beam brightness associated with the fresh bunch. Possible applications to ERL and beam-driven wakefield accelerators are also discussed.

Phillips, C.↗

LLRF System for the Fermilab Mu2e Project – AC Dipole Extinction

The Mu2e experiment measures the conversion rate of muons into electrons. The experiments requires 53 MHz batches of 8 GeV protons to be re-bunched into 150 ns, 2.5 MHz pulses for extraction to a single RF cavity running at 2.36 MHz. To meet stringent limits on the amount of beam between pulses, an Extinction System is used comprising of 2 AC dipole magnets (4.4MHz, 296Khz) and a collimator.

Guran, M. [Fermilab] (ORCID:0009000235538559)↗

Dynamic Multipoles in the RCS

The Rapid Cycling Synchrotron (RCS) of the Electron--Ion Collider (EIC) will accelerate polarized electrons up to 18 GeV at a repetition rate of 1 Hz. Dynamic multipoles driven by eddy currents in the vacuum chamber can affect beam dynamics and polarization preservation during the energy ramp. Building on the analytical treatment of S.Y. Lee for a ramped normal-conducting dipole magnet, we use conformal transformations to derive compact expressions for dynamic multipoles in higher-order ramped magnets with circular beam pipes. We further derive analytical frequency-domain transfer functions for both self-response and cross-response multipoles, providing compact dynamical models for their evolution during arbitrary ramp waveforms. The resulting analytical predictions are benchmarked against finite-element simulations, including the effects of practical pole geometry and beam-pipe misalignment. Finally, the expected dynamic multipoles in the RCS magnets are estimated and their implications for beam dynamics and polarization preservation are discussed.

43 PARTICLE ACCELERATORS↗

Calibration and Localization of Optically Pumped Magnetometers Using Electromagnetic Coils

In this paper, we propose a method to estimate the position, orientation, and gain of a magnetic field sensor using a set of (large) electromagnetic coils. We apply the method for calibrating an array of optically pumped magnetometers (OPMs) for magnetoencephalography (MEG). We first measure the magnetic fields of the coils at multiple known positions using a well-calibrated triaxial magnetometer, and model these discreetly sampled fields using vector spherical harmonics (VSH) functions. We then localize and calibrate an OPM by minimizing the sum of squared errors between the model signals and the OPM responses to the coil fields. We show that by using homogeneous and first-order gradient fields, the OPM sensor parameters (gain, position, and orientation) can be obtained from a set of linear equations with pseudo-inverses of two matrices. The currents that should be applied to the coils for approximating these low-order field components can be determined based on the VSH models. Computationally simple initial estimates of the OPM sensor parameters follow. As a first test of the method, we placed a fluxgate magnetometer at multiple positions and estimated the RMS position, orientation, and gain errors of the method to be 1.0 mm, 0.2°, and 0.8%, respectively. Lastly, we calibrated a 48-channel OPM array. The accuracy of the OPM calibration was tested by using the OPM array to localize magnetic dipoles in a phantom, which resulted in an average dipole position error of 3.3 mm. The results demonstrate the feasibility of using electromagnetic coils to calibrate and localize OPMs for MEG.

47 OTHER INSTRUMENTATION↗

THE COMBINATION OF ACTIVE AND PASSIVE SHIELDING

I is conceivable that improved shielding of space vehicles against high-energy charged-particle radiation can be obtained by combining active and passive shielding. Methods of shielding calculations and some preliminary observations pertaining to active-passive shielding are given. An analysis based upon the field of a magnetic dipole indicates that weight savings in bulk shielding can be accomplished.

SPACECRAFT SHIELDING↗

A Passive Gravitational Attitude Control System for Satellites

It is shown how the gravity-gradient effect may be utilized to design a long-lived, earth-pointing satellite attitude control system which requires no fuel supplies, attitude sensors or active control equipment. This two-body system is provided with a magnetic hysteresis damper which effectively damps out oscillations (librations) about the local vertical. The long rods, which must be extended in space from coiled up metal tapes, provide the required large moments of inertia and possess adequate rigidity and sufficient strength to endure the rigors of the extension process. The system is compatible with the requirements of multiple satellite launchings from a single last-stage vehicle. Analysis indicates that the gravitational torques are sufficient to keep the disturbing effects of solar radiation pressure, residual magnetic dipole moments, orbit eccentricity, rod curvature, eddy currents, and meteorite impacts within tolerable limits. It is believed that the high-performance, earth-pointing system described and analyzed in this paper represents an essential step in the development of high-capacity communications satellites requiring long life.

GRAVITY↗

Mariner V flight past Venus.

Experiments conducted by Mariner 5 during flight past Venus, discussing magnetic dipole moment and solar wind flows

Snyder, C. W.↗

The infrared emission of NGC 7027.

IR emission in NGC 7027 spectrum and role of discrete line emissions, discussing magnetic dipole transitions, temperature and density

Goldberg, L.↗

Planetary magnetic field experiments.

Planetary magnetic field measurements near Venus, Mars, and moon, noting magnetic dipole comparison with earth and solar wind interactions

Smith, E. J.↗