Search NASA⌕ Search

SEARCH · Search NASA

Results for “MONOCHROMATIC RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

TH-AB-207A-09: Tailoring TCM Schemes to a Task: Evaluating the Impact of Customized TCM Profiles On Detection of Lung Nodules in Simulated CT Lung Cancer Screening

Purpose: Recent work has shown that current TCM profile designs boost detection of low-contrast lung lesions in the lung apices, but yield reduced detection performance in the mid and lower lung regions relative to fixed tube current cases. This observed imbalance suggests that the TCM scheme might be tailored in new ways to maximize nodule detection throughout the entire lung. In this work, we begin a preliminary investigation into custom TCM profiles in an attempt to achieve uniform lesion detection throughout the extent of the lung. Methods: Low-contrast (25HU), 6mm nodules representing ground glass opacities were simulated at 1mm intervals over the length the lungs in a voxelized model of the XCAT phantom, one nodule per lung, per simulated scan. Voxel values represented attenuation values at 80keV. CT projection data was created by simulating a finite focal spot and using Joseph’s method for forward projection; scanner geometry was that of the Siemens Sensation 64 and the X-ray source was simulated as an 80keV monochromatic beam. Noise realizations were created using Poisson statistics, a realistic bowtie filter and varying tube current. 500 noise realizations were created for the custom TCM designs. All reconstruction was done with FreeCT-wFBP. An SKE/BKE task was used in conjunction with a 2D Hotelling Observer to calculate area-under-the-curve (AUC) as a proxy for “detectability.” AUC was plotted as a function of nodule Z-location to create a “detectability map.” The detectability map for the custom TCM curve was qualitatively assessed relative to previous results for the fixed TC and clinical TCM cases for uniformity. Results: Detection uniformity was improved throughout the mid and lower lungs, however detection remained disproportionately high in the upper lung region. Conclusion: Detection uniformity was improved with a custom TC profile. Future work will incorporate an analytic, task-specific approach to optimize the TC scheme for nodule detection. J. Hoffman: Part-time intern, Toshiba Medical Research Institute; M. McNitt-Gray: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; F. Noo: Institutional research agreement, Siemens Healthcare; Receives research funding from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

Design and Technical Aspects of a New in Vacuum Transfocator at ESRF Beamline ID11

A tunable X-Ray focusing apparatus based on compound refractive lenses (CRL), referred to as a transfocator, has been installed for monochromatic beam (IAT in air transfocator) two years ago in the second optics hutch at ID11 at the ESRF. By varying the number of lenses in the beam, the energy focused and the focal length can be varied continuously throughout a large range of energies and distances.Based the success of the IAT, an in-vacuum transfocator (IVT) has now been built and installed at ID11.The aim of this poster is to describe and show the mechanical and technical solutions used to design and manufacture this new IVT.The IVT was installed last January in the first optics hutch at ID11. The IVT consists of nine water cooled cartridges containing 1, 2, 4, 8, 16, 32 Be lenses, and 32 and 64 Al lenses, and a protective aperture of Oe 900 {mu}m. The mechanical design is based on a system of pneumatically actuated cartridges with an auto positioning on two stainless steel rods. The vacuum vessel has translations and rotations perpendicular to the beam direction in order to align the axis of the cartridges with the x-ray beam.

43 PARTICLE ACCELERATORS↗

On precession of entangled spins in a strong laser field

A dynamics of the entanglement under an environmental influence is modelled by a bound state composed of two heavy particles interacting with a strong laser. Adopting the semiclassical attitude, a trajectory of the bound state's center-of-mass is found from the Newton equations solved beyond the dipole approximation and taking into account the magnetic field effect. At the same time the dynamics of constituent spins under the laser coupling is studied quantum mechanically solving the nonrelativistic von Neumann equation with the effective Hamiltonian determined by the bound state's classical trajectory. Based on the solution, the effects of an intense linearly polarized monochromatic plane wave on the precession of entangled spins are discussed for a specific kind of mixed initial states including a family of maximally entangled Werner states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constraints on the dark matter annihilation scenario of Fermi 130 GeV gamma-ray line emission by continuous gamma-rays, Milky Way halo, galaxy clusters and dwarf galaxies observations

It was recently reported that there may exist monochromatic γ-ray emission at ∼ 130 GeV from the Galactic center in the Fermi Large Area Telescope data, which might be related with dark matter (DM) annihilation. In this work we carry out a comprehensive check of consistency of the results with the DM annihilation scenario, using the 3.7 yrs Fermi observation of the inner Galaxy, Galactic halo, clusters of galaxies and dwarf galaxies. The results found are as follows. 1) Very strong constraints on the DM annihilation into continuous γ-rays from the Galactic center are set, which are as stringent as the 'natural' scale assuming thermal freeze-out of DM. Such limit sets strong constraint on the DM models to explain the line emission. 2) No line emission from the Galactic halo is found in the Fermi data, (and the constraints on line emission is marginally consistent with) the DM annihilation interpretation of the ∼ 130 GeV line emission from the inner Galaxy. 3) No line emission from galaxy clusters and dwarf galaxies is detected, although possible concentration of photons from clusters in 120–140 GeV is revealed. The constraints from clusters and dwarf galaxies are weak and consistent with the DM annihilation scenario to explain the ∼ 130 GeV line emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Linewidth oscillations in a nanometer-size double-slit interference experiment with single electrons

In this article we provide experimental evidence of an interference phenomenon that, to the best of our knowledge, has so far not been observed with either matter or light. In a nanometer-sized version of Feynman's famous two-slit 'thought' experiment with single electrons, we managed to observe that the width of a quasi-monochromatic line oscillates with the detection angle. Furthermore, we find that it occurs in counterphase with the line intensity. We discuss the underlying mechanism that produces this unexpected result.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measuring the parameters of massive black hole binary systems with pulsar timing array observations of gravitational waves

The observation of massive black hole binaries with pulsar timing arrays (PTAs) is one of the goals of gravitational-wave astronomy in the coming years. Massive (> or approx. 10{sup 8}M{sub {center_dot}}) and low-redshift (< or approx. 1.5) sources are expected to be individually resolved by upcoming PTAs, and our ability to use them as astrophysical probes will depend on the accuracy with which their parameters can be measured. In this paper we estimate the precision of such measurements using the Fisher-information-matrix formalism. For this initial study we restrict ourselves to 'monochromatic' sources, i.e. binaries whose frequency evolution is negligible during the expected {approx_equal}10 yr observation time, which represent the bulk of the observable population based on current astrophysical predictions. In this approximation, the system is described by seven parameters and we determine their expected statistical errors as a function of the number of pulsars in the array, the array sky coverage, and the signal-to-noise ratio (SNR) of the signal. At fixed SNR (regardless of the number of pulsars in the PTA), the gravitational-wave astronomy capability of a PTA is achieved with {approx_equal}20 pulsars; adding more pulsars (up to 1000) to the array reduces the source error box in the sky {Delta}{Omega} by a factor {approx_equal}5 and has negligible consequences on the statistical errors on the other parameters, because the correlations among parameters are already removed to a large extent. If one folds in the increase of coherent SNR proportional to the square root of the number of pulsars, {Delta}{Omega} improves as 1/SNR{sup 2} and the other parameters as 1/SNR. For a fiducial PTA of 100 pulsars uniformly distributed in the sky and a coherent SNR=10, we find {Delta}{Omega}{approx_equal}40 deg{sup 2}, a fractional error on the signal amplitude of {approx_equal}30% (which constrains only very poorly the chirp mass-luminosity distance combination M{sup 5/3}/D{sub L}), and the source inclination and polarization angles are recovered at the {approx_equal}0.3 rad level. The ongoing Parkes PTA is particularly sensitive to systems located in the southern hemisphere, where at SNR=10 the source position can be determined with {Delta}{Omega}{approx_equal}10 deg{sup 2}, but has poorer (by an order of magnitude) performance for sources in the northern hemisphere.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-QI-13: Predictable Models for Radio-Sensitizing Agent Kinetics: Application to Stereotactic Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The radiation dose enhancement depends on the time course of iodine in the tumors. A prolonged CT scanning (∼30 min) is required to follow-up iodine kinetics for recruited patients. This protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce the acquisition time. Methods: 12 patients received an intravenous bolus of iodinated contrast agent, followed by a steady-state infusion to ensure stable intra-tumoral amounts of iodine during the treatment. Absolute iodine concentrations (IC) were derived from 40 multi-slice dynamic conventional CT images of the brain. The impulse response function (IRF) to the bolus was estimated using the adiabatic approximation of the Johnson and Wilson's model. The arterial input function (AIF) of the steady-state infusion was fitted with several models: Gamma, Gamma with recirculation and hybrid. Estimated IC were calculated by convolving the IRF with the modeled AIF and were compared to the measured data. Results: The gamma variate function was not relevant to model the AIF due to high differences with the measured AIF. The hybrid and the gamma with recirculation models provided differences below 8% during the whole acquisition time. The absolute difference between the measured and the estimated IC was lower than 0.5 mg/ml, which corresponds to 5% of dose enhancement error. Conclusion: The proposed method allows a good estimation of the iodine time course with reduced scanning delays (3 instead of 30 min) and dose to the patient. The results suggest that the dose errors may stay within the radiotherapy standards.

60 APPLIED LIFE SCIENCES↗

Simulation of particle acceleration in the PLASMONX project

In this paper I will present some numerical studies and parameter scans performed with the electromagnetic, rela-tivistic, fully-self consistent particle-in-cell (PIC) code ALaDyn (Acceleration by LAser and DYNamics of charged particles), concerning electron acceleration via plasma waves in the framework of the INFN-PLASMONX (PLASma acceleration and MONochromatic X-ray production) project. In particular I will focus on the modelling of the SITE (Self Injection Test Experiment) which will be a relevant part of the commissioning of the FLAME laser. Some issues related to the quality of the accelerated bunch will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On the implementation of computed laminography using synchrotron radiation

Hard x rays from a synchrotron source are used in this implementation of computed laminography for three-dimensional (3D) imaging of flat, laterally extended objects. Due to outstanding properties of synchrotron light, high spatial resolution down to the micrometer scale can be attained, even for specimens having lateral dimensions of several decimeters. Operating either with a monochromatic or with a white synchrotron beam, the method can be optimized to attain high sensitivity or considerable inspection throughput in synchrotron user and small-batch industrial experiments. The article describes the details of experimental setups, alignment procedures, and the underlying reconstruction principles. Imaging of interconnections in flip-chip and wire-bonded devices illustrates the peculiarities of the method compared to its alternatives and demonstrates the wide application potential for the 3D inspection and quality assessment in microsystem technology.

43 PARTICLE ACCELERATORS↗

Extra gamma-ray strength for {sup 116,117}Sn arising from pygmy dipole resonance

Photoneutron cross sections were measured for {sup 117}Sn and {sup 116}Sn near neutron thresholds with quasi-monochromatic laser Compton scattering gamma-rays. The measured cross sections for {sup 117}Sn and {sup 116}Sn are strongly enhanced from the threshold behavior expected for L = 1 neutron emissions after E1 photoexcitation. This suggests the presence of extra gamma-ray strength in the low-energy tail of the giant dipole resonance. The present cross sections were analyzed together with radiative neutron capture cross sections for {sup 116}Sn within the framework of the statistical model calculation. It is shown that the extra gamma-ray strength can be interpreted as pygmy E1 resonance which was previously reported in the nuclear resonance fluorescence experiment for {sup 116}Sn and {sup 124}Sn.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A mirror for lab-based quasi-monochromatic parallel x-rays

A multilayered parabolic mirror with six W/Al bilayers was designed and fabricated to generate monochromatic parallel x-rays using a lab-based x-ray source. Using this mirror, curved bright bands were obtained in x-ray images as reflected x-rays. The parallelism of the reflected x-rays was investigated using the shape of the bands. The intensity and monochromatic characteristics of the reflected x-rays were evaluated through measurements of the x-ray spectra in the band. High intensity, nearly monochromatic, and parallel x-rays, which can be used for high resolution x-ray microscopes and local radiation therapy systems, were obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vacuum-ultraviolet-induced charge depletion in plasma-charged patterned-dielectric wafers

Plasma-induced charging of patterned-dielectric structures during device fabrication can cause structural and electrical damage to devices. In this work, we report on vacuum-ultraviolet (VUV) radiation-induced charge depletion in plasma-charged patterned-silicon-oxide dielectric wafers. Charge depletion is studied as a function of photon energy and the aspect ratio of hole structures. The wafers were charged in a plasma and subsequently exposed to monochromatic-synchrotron-VUV. Surface-potential measurements after VUV exposure showed that photon energies less than 11 eV were beneficial in depleting the plasma-induced charge from the patterned-dielectric wafers. In addition, for a given photon-flux density and for photon energies less than 11 eV, VUV-induced charge depletion decreases with increasing hole aspect ratio. The results are explained with a physically plausible equivalent-circuit model, which suggests that both electron photoinjection from Si into the oxide and oxide surface conductivity play an important role in the charge-depletion process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The spectral energy distributions of Fermi blazars

In this paper, multiwavelength data are compiled for a sample of 1425 Fermi blazars to calculate their spectral energy distributions (SEDs). A parabolic function, log(νF{sub ν})=P{sub 1}(logν−P{sub 2}){sup 2}+P{sub 3}, is used for SED fitting. Synchrotron peak frequency (logν{sub p}), spectral curvature (P{sub 1}), peak flux (ν{sub p}F{sub ν{sub p}}), and integrated flux (νF{sub ν}) are successfully obtained for 1392 blazars (461 flat-spectrum radio quasars [FSRQs], 620 BL Lacs [BLs], and 311 blazars of uncertain type [BCUs]; 999 sources have known redshifts). Monochromatic luminosity at radio 1.4 GHz, optical R band, X-ray at 1 keV and γ-ray at 1 GeV, peak luminosity, integrated luminosity, and effective spectral indices of radio to optical (α{sub RO}) and optical to X-ray (α{sub OX}) are calculated. The “Bayesian classification” is employed to log ν{sub p} in the rest frame for 999 blazars with available redshift, and the results show that three components are enough to fit the log ν{sub p} distribution; there is no ultra-high peaked subclass. Based on the three components, the subclasses of blazars using the acronyms of Abdo et al. are classified, and some mutual correlations are also studied. Conclusions are finally drawn as follows: (1) SEDs are successfully obtained for 1392 blazars. The fitted peak frequencies are compared with common sources from available samples. (2) Blazars are classified as low synchrotron peak sources if log ν{sub p}(Hz)⩽14.0, intermediate synchrotron peak sources if 14.0< log ν{sub p}(Hz)⩽15.3, and high synchrotron peak sources if log ν{sub p}(Hz)>15.3. (3) Gamma-ray emissions are strongly correlated with radio emissions. Gamma-ray luminosity is also correlated with synchrotron peak luminosity and integrated luminosity. (4) There is an anticorrelation between peak frequency and peak luminosity within the whole blazar sample. However, there is a marginally positive correlation for high synchrotron peak BL Lacs (HBLs), and no correlations for FSRQs or low synchrotron peak BL Lacs (LBLs). (5) There are anticorrelations between the monochromatic luminosities (γ-ray and radio bands) and the peak frequency within the whole sample and BL Lacs. (6) The optical to X-ray (α{sub OX}) and radio to optical (α{sub RO}) spectral indices are strongly anticorrelated with peak frequency (log ν{sub p}) within the whole sample, but the correlations for subclasses of FSRQs, LBLs, and HBLs are different.

79 ASTRONOMY AND ASTROPHYSICS↗

Nonlinear Compton scattering of ultrashort intense laser pulses

The scattering of temporally shaped intense laser pulses off electrons is discussed by means of manifestly covariant quantum electrodynamics. We employ a framework based on Volkov states with a time-dependent laser envelope in light-cone coordinates within the Furry picture. An expression for the cross section is constructed unambiguously in respect of the pulse length. A broad distribution of scattered photons with a rich pattern of subpeaks like that obtained in Thomson scattering is found. These broad peaks may overlap at sufficiently high laser intensity, rendering inappropriate the notion of individual harmonics. The limit of monochromatic plane waves as well as the classical limit of Thomson scattering are discussed. As a main result, a scaling law is presented connecting the Thomson limit with the general result for arbitrary kinematics. In the overlapping regions of the spectral density, the classical and quantum calculations give different results, even in the Thomson limit. Thus, a phase-space region is identified where the differential photon distribution is strongly modified by quantum effects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-Ray Converters On Dense Ionization Waves With Tunable Velocities

The optical field ionization of a transparent media by two, cylindrically focused femtosecond laser pulses may result in production of an ionization wave (IW). Velocity of such a quasi-plane IW in the vicinity of pulse intersection can be tuned by changing the intersection angle and can even exceed the speed of light. We study the conversion of a coherent light to x-rays by means of particle-in-cell simulation and by solution of continuous equation with the correct current: j(x,t) -eintegral(dN{sub e}/dt{sub 0})v(t,t{sub 0})dt{sub 0}.X-ray spectrum of converted lower frequency light changes from the monochromatic to a high order harmonic-like with the duration of ionizing pulses. The conversion efficiency can be increased via suppression the energy of the generated magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Manifestation of the geometric phase in neutron spin-echo experiments

We show how the geometric (Berry's) phase becomes manifest on adiabatic rotation of the polarization vector in the magnetic field configuration in the arms in a neutron spin echo (NSE) experiment. When the neutron beam used is monochromatic, a geometric phase collected in one spin-echo arm can be exactly compensated in the other arm either by an opposite geometrical rotation or by adding/subtracting a dynamic (Larmor) phase. This is not possible in a white beam, because, contrary to the dynamic phase, the geometric phase is independent of wavelength. Therefore, the NSE pattern can be disturbed. We demonstrate that adiabatic resonant spin flippers inherently produce a geometric phase which can influence the performance of NSE setups based on such flippers. This effect can be avoided by a proper mutual symmetry of the gradient fields in these flippers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An Open-path Laser Transmissometer for Atmospheric Extinction Measurements

A transmissometer is an optical instrument which measures transmitted intensity of monochromatic light over a fixed pathlength. Prototype of a simple laser transmissometer has been developed for transmission (or extinction) measurements through suspended absorbers and scatterers in the atmosphere over tens of meters. Instrument consists of a continuous green diode pumped solid state laser, transmission optics, photodiode detectors and A/D data acquisition components. A modulated laser beam is transmitted and subsequently reflected and returned to the unit by a retroreflecting mirror assembly placed several tens of meters away. Results from an open-path field measurement of the instrument are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗