Search NASA⌕ Search

SEARCH · Search NASA

Results for “Materials Test Module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Benchmark Modeling and Simulation of the FFTF LOFWOS Test #13 Using SAM

The Fast Flux Test Facility (FFTF) was a 400 MW thermal powered, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. In July 1986, a series of unprotected Loss of Flow Without Scram (LOFWOS) transients were performed in FFTF as part of the Passive Safety Testing (PST) program. The LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors left off, has been chosen as a benchmark case by IAEA to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of sodium fast reactor passive safety in an IAEA Coordinated Research Project (CRP), launched in October 2018. The System Analysis Module (SAM) is an advanced and modern system analysis tool under development at Argonne National Laboratory for advanced non-LWR safety analysis. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. To participate the IAEA CRP and enhance the SAM validation base for advanced reactor transient safety analysis, benchmark simulations of the FFTF LOFWOS Test #13 are performed using the SAM code. In this first phase of the validation effort, the thermal-hydraulic behavior of the reactor system is the focus and the reactor kinetics is not considered in the SAM FFTF model. Instead, the results of Argonne’s neutronics calculations are directly used, including the power shape of the active core region and the power history during the transient. The simulation results of FFTF at steady state agreed well with the measured data from the test. During the transient, reasonably good agreement were also obtained. Future work to improve the model will focus on introducing the reactivity predictions into the model, as well as better understanding or resolving the current discrepancies with the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Biophysical control of the growth of Agrobacterium tumefaciens using extremely low frequency electromagnetic waves at resonance frequency

Isolated Agrobacterium tumefaciens was exposed to different extremely low frequencies of square amplitude modulated waves (QAMW) from two generators to determine the resonance frequency that causes growth inhibition. The carrier was 10 MHz sine wave with amplitude ±10 Vpp which was modulated by a second wave generator with a modulation depth of ± 2Vpp and constant field strength of 200 V/m at 28 °C. The exposure of A. tumefaciens to 1.0 Hz QAMW for 90 min inhibited the bacterial growth by 49.2%. In addition, the tested antibiotics became more effective against A. tumefaciens after the exposure. Furthermore, results of DNA, dielectric relaxation and TEM showed highly significant molecular and morphological changes due to the exposure to 1.0 Hz QAMW for 90 min. An in-vivo study has been carried out on healthy tomato plants to test the pathogenicity of A. tumefaciens before and after the exposure to QAMW at the inhibiting frequency. Symptoms of crown gall and all pathological symptoms were more aggressive in tomato plants treated with non-exposed bacteria, comparing with those treated with exposed bacteria. We concluded that, the exposure of A. tumefaciens to 1.0 Hz QAMW for 90 min modified its cellular activity and DNA structure, which inhibited the growth and affected the microbe pathogenicity.

60 APPLIED LIFE SCIENCES↗

Reactor Physics Characterization of the HTR Module with UCO Fuel

ABSTRACT The HTR Module [1] is a graphite-moderated, helium cooled pebble bed High Temperature Reactor (HTR) design that has been extensively used as a reference template for the former South African and current Chinese HTR [2] programs. This design utilized spherical fuel elements packed into a dynamic pebble bed, consisting of TRISO coated uranium oxide (UO2) fuel kernels with a U-235 enrichment of 7.8% and a Heavy Metal loading of 7 grams per pebble. The main objective of this study is to compare several important reactor physics and core design parameters for the HTR Module and an identical design utilizing UCO fuel kernels. Fuel kernels of this type are currently being tested in the Idaho National Laboratory’s (INL) Advanced Test Reactor (ATR) as part of the larger Next Generation Nuclear Plant (NGNP) project. The PEBBED-THERMIX [3] code, which was developed specifically for the analysis of pebble bed HTRs, was used to compare the coupled neutronic and thermal fluid performance of the two designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Three-Dimensional Analysis of Recurrence Patterns in Rectal Cancer: The Cranial Border in Hypofractionated Preoperative Radiotherapy Can Be Lowered

Purpose: The aim of this study was to determine whether and where the radiotherapy (RT) clinical target volume (CTV) could be reduced in short-course preoperative treatment of rectal cancer patients. Methods and Materials: Patients treated in the Dutch total mesorectal excision trial, with a local recurrence were analyzed. For 94 (25 who underwent radiation therapy 69 who did not) of 114 patients with a local recurrence, the location of the recurrence was placed in a three-dimensionalthree (3D) model. The data in the 3D model were correlated to the clinical trial data to distinguish a group of patients eligible for CTV reduction. Effects of CTV reduction on dose to the small bowel was tested retrospectively in a dataset of 8 patients with three-field conformal plans and intensity-modulated RT (IMRT). Results: The use of preoperative RT mainly reduces anastomotic, lateral, and perineal recurrences. In patients without primary nodal involvement, no recurrences were found cranially of the S2-S3 interspace, irrespective of the delivery of RT. In patients without primary nodal involvement and a negative circumferential resection margin (CRM), only one recurrence was found cranial to the S2-S3 interspace. With a cranially reduced CTV to the S2-S3 interspace, over 60% reduction in absolute small bowel exposure at dose levels from 15 to 35 Gy could be achieved with three-field conventional RT, increasing to 80% when IMRT is also added. Conclusions: The cranial border of the CTV can safely be lowered for patients without expected nodal or CRM involvement, yielding a significant reduction of dose to the small bowel. Therefore, a significant reduction of acute and late toxicity can be expected.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlled release of cortisone drugs from block copolymers synthetized by ATRP

Diseases affecting posterior eye segment, like macular edema, infection and neovascularization, may cause visual impairment. Traditional treatments, such as steroidal-drugs intravitreal injections, involve chronic course of therapy usually over a period of years. Moreover, they can require frequent administrations of drug in order to have an adequately disease control. This dramatically reduce patient’s compliance. Efforts have been made to develop implantable devices that offer an alternative therapeutic approach to bypass many challenges of conventional type of therapy. Implantable drug delivery systems (DDS) have been developed to optimize therapeutic properties of drugs and ensure their slow release in the specific site. Polymeric materials can play an essential role in modulating drug delivery and their use in such field has become indispensable. During last decades, acrylic polymers have obtained growing interest. Biocompatibility and chemical properties make them extremely versatile, allowing their use in many field such as biomedical. In particular, block methacrylate copolymer with a balance of hydrophilic and hydrophobic properties can be suitable for prolonged DDS in biomedical devices. In this work, we focused on the realization of a system for controlled and long term release of betamethasone 17,21-dipropionate (BDP), a cortisone drug, from methacrylic block copolymers, to be tested in the treatment of the posterior eye’s diseases. Different series of methyl methacrylate/hydroxyethyl methacrylate (MMA/HEMA) block and random copolymers, with different monomer compositions (10–60% HEMA), were synthetized by Atom Transfer Radical Polymerization (ATRP) to find the best hydrophilic/hydrophobic ratio, able to ensure optimal kinetic release. Copolymer samples were characterized by NMR spectroscopy ({sup 1}H-NMR, {sup 13}C-NMR, CosY), SEC, TGA and DSC. Monitoring of drug release from films loaded with BDP was carried out by HPLC analysis. Evaluation of different kinetic models allowed to deduce that release of BDP is controlled over time from PMMA-b-PHEMA 53/47. In particular, PMMA-b-PHEMA 53/47 showed the best release profile to achieve the therapeutic reference dose of 3 µg/die, employed in treatment of posterior eye disease, up to four months. Accordingly, PMMA-b-PHEMA 53/47 has been tested to prepare ocular inserts. Ocular inserts with different shape and the same area of polymer films have been obtained using silicon moulds made by a 3D printer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advanced Thin Film Core Technology: CIGS Final Technical Report (FTR)

Cu(In,Ga)Se 2 (CIGS) thin-film photovoltaics are a high-efficiency and reliable technology. This project completed research in two important areas and was designed to work collaboratively with industrial partners. Task 1: Alkali Science focused on alkali post-deposition treatments (PDT). PDTs have been instrumental in the dramatic voltage improvements that have moved CIGS device efficiencies from 20% to 23.35% [1]. Based on a survey of CIGS companies at the beginning of the project, the single biggest breakthrough for the CIGS community would be a mechanistic understanding of the role of alkalis in the material system. Significant accomplishments of Task 1: Alkali Science: 1) KF post-deposition treatments were shown to improve lifetime, open-circuit voltage (VOC), and efficiency of industrial partner samples, even when done as a later step, separate from the original CIGS deposition. 2) KF boosted efficiency when incorporated at the end of the third stage of NREL CIGS growth. 3) XPS characterization of CIGS surfaces with and without PDTs led to a proposed mechanism whereby K drives structural transformation at 350 degrees C that is locked in at room temperature even after K is rinsed away. 4) Published recipes for KF and RbF PDTs. Literature to date did not provide enough detail to quickly reproduce experimental results. 5) Identified most important parameters (RbF cell temperature and lamp setpoint temperature) and set boundaries for successful RbF PDTs. The purpose of Task 2: Cell-level Reliability was to overcome the largest challenges to investor confidence and long product lifetime in CIGS-based photovoltaic products: metastability, shading-induced hot spots, and potential-induced degradation (PID). Key findings were made in each of these areas by studying CIGS reliability at the cell level: 1) Published NREL's cell-level reliability testing procedures along with challenges that were encountered while developing them. These were also distributed to the community through an MRS conference presentation. 2) Decreased metastability by adding a CdS hole-injection layer between the CIGS and Zn(O,S) in the device stack. It also improved device performance. Materials other than CdS can be used for the same purpose. 3) Reduced front-glass PID by replacing soda-lime glass with low-Na borosilicate glass. 4) Found that PID depends on leakage current and light/electrical bias. This will help labs avoid test-specific degradation. 5) Discovered that CIGS can suffer from two different types of PID with different mechanisms. Front is slower and leads to shunting ZnO. Back is faster and degrades the p-n junction. 6) Holding cells at open circuit slows PID compared to short circuit. This affects testing protocols for glass/glass modules.

14 SOLAR ENERGY↗

Critical Combinations of Radiation Dose and Volume Predict Intelligence Quotient and Academic Achievement Scores After Craniospinal Irradiation in Children With Medulloblastoma

Purpose: To prospectively follow children treated with craniospinal irradiation to determine critical combinations of radiation dose and volume that would predict for cognitive effects. Methods and Materials: Between 1996 and 2003, 58 patients (median age 8.14 years, range 3.99-20.11 years) with medulloblastoma received risk-adapted craniospinal irradiation followed by dose-intense chemotherapy and were followed longitudinally with multiple cognitive evaluations (through 5 years after treatment) that included intelligence quotient (estimated intelligence quotient, full-scale, verbal, and performance) and academic achievement (math, reading, spelling) tests. Craniospinal irradiation consisted of 23.4 Gy for average-risk patients (nonmetastatic) and 36-39.6 Gy for high-risk patients (metastatic or residual disease >1.5 cm{sup 2}). The primary site was treated using conformal or intensity modulated radiation therapy using a 2-cm clinical target volume margin. The effect of clinical variables and radiation dose to different brain volumes were modeled to estimate cognitive scores after treatment. Results: A decline with time for all test scores was observed for the entire cohort. Sex, race, and cerebrospinal fluid shunt status had a significant impact on baseline scores. Age and mean radiation dose to specific brain volumes, including the temporal lobes and hippocampi, had a significant impact on longitudinal scores. Dichotomized dose distributions at 25 Gy, 35 Gy, 45 Gy, and 55 Gy were modeled to show the impact of the high-dose volume on longitudinal test scores. The 50% risk of a below-normal cognitive test score was calculated according to mean dose and dose intervals between 25 Gy and 55 Gy at 10-Gy increments according to brain volume and age. Conclusions: The ability to predict cognitive outcomes in children with medulloblastoma using dose-effects models for different brain subvolumes will improve treatment planning, guide intervention, and help estimate the value of newer methods of irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

RELAP5-3D Results for Phase I (Exercise 2) of the OECD/NEA MHTGR-350 MW Benchmark

The coupling of the PHISICS code suite to the thermal hydraulics system code RELAP5-3D has recently been initiated at the Idaho National Laboratory (INL) to provide a fully coupled prismatic Very High Temperature Reactor (VHTR) system modeling capability as part of the NGNP methods development program. The PHISICS code consists of three modules: INSTANT (performing 3D nodal transport core calculations), MRTAU (depletion and decay heat generation) and a perturbation/mixer module. As part of the verification and validation activities, steady state results have been obtained for Exercise 2 of Phase I of the newly-defined OECD/NEA MHTGR-350 MW Benchmark. This exercise requires participants to calculate a steady-state solution for an End of Equilibrium Cycle 350 MW Modular High Temperature Reactor (MHTGR), using the provided geometry, material, and coolant bypass flow description. The paper provides an overview of the MHTGR Benchmark and presents typical steady state results (e.g. solid and gas temperatures, thermal conductivities) for Phase I Exercise 2. Preliminary results are also provided for the early test phase of Exercise 3 using a two-group cross-section library and the Relap5-3D model developed for Exercise 2.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

RELAP5-3D results for phase I (Exercise 2) of the OECD/NEA MHTGR-350 MW benchmark

The coupling of the PHISICS code suite to the thermal hydraulics system code RELAP5-3D has recently been initiated at the Idaho National Laboratory (INL) to provide a fully coupled prismatic Very High Temperature Reactor (VHTR) system modeling capability as part of the NGNP methods development program. The PHISICS code consists of three modules: INSTANT (performing 3D nodal transport core calculations), MRTAU (depletion and decay heat generation) and a perturbation/mixer module. As part of the verification and validation activities, steady state results have been obtained for Exercise 2 of Phase I of the newly-defined OECD/NEA MHTGR-350 MW Benchmark. This exercise requires participants to calculate a steady-state solution for an End of Equilibrium Cycle 350 MW Modular High Temperature Reactor (MHTGR), using the provided geometry, material, and coolant bypass flow description. The paper provides an overview of the MHTGR Benchmark and presents typical steady state results (e.g. solid and gas temperatures, thermal conductivities) for Phase I Exercise 2. Preliminary results are also provided for the early test phase of Exercise 3 using a two-group cross-section library and the Relap5-3D model developed for Exercise 2. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Upscaling of asymmetric hollow fiber‐supported thin film membranes for oxygen separation from air: Proof of concept

Abstract Hollow fiber membranes demonstrate various advantages for high performance oxygen separation. However, the small diameters of hollow fibers and the brittleness of ceramics limit their mechanical strength, imposing great difficulties on stack and module development. Gas‐tight sealing is another challenge for upscaling of hollow fiber membrane technology. Low temperature sealant materials of epoxy resin or silicon are typically used for hollow fiber stacks, requiring that the sealing portions be located out of hot zone. Consequently, only partial length of hollow fibers participates in oxygen permeation. In this study, upscaling of our recently developed asymmetric hollow fiber‐supported thin film membranes is conducted, where individual hollow fibers are assembled in parallel to form a stack. A reliable gas‐tight sealing is obtained by combining ceramic paste with conductive adhesive ink cohesively. Comprehensive oxygen permeation test is conducted with the sealing portions being in hot zone and compared with a single hollow fiber membrane. Fundamental mechanism is discussed to understand the performances and their differences. An accelerated long‐term test (∼320 h, 16 thermal cycles) demonstrates excellent stability and robustness of the stack and sealing. The characterization of post‐test samples further confirms excellent stability and robustness of the phases and microstructures of the stack.

36 MATERIALS SCIENCE↗

Component Modeling, Co-Optimization, and Trade-Space Evaluation (FY2021 Annual Progress Report)

This project is intended to support the development of new traction drive systems that meet the targets of 100 kW/L for power electronics and 50 kW/L for electric machines with reliable operation to 300,000 miles. To meet these goals, new designs must be identified that make use of state-of-the-art and next-generation electronic materials and design methods. Designs must exploit synergies between components, for example converters designed for high-frequency switching using wide band gap devices and ceramic capacitors. This project includes: (1) a survey of available technologies; (2) the development of design tools that consider the converter volume and performance; (3) exercising the design software to evaluate performance gaps and predict the impact of certain technologies and design approaches, i.e. GaN semiconductors, ceramic capacitors, and select topologies; and (4) building and testing hardware prototypes to validate models and concepts. Early instantiations of the design tools enable co-optimization of the power module and passive elements and provide some design guidance; later instantiations will enable the co-optimization of inverter and machine. Prototype testing begins with evaluation of simpler conversion topologies (i.e. the half-bridge boost converter) and progresses with fabrication of prototype inverter drives.

33 ADVANCED PROPULSION SYSTEMS↗

Advanced Perovskite Solar Cells and Modules

The “Advanced perovskite Cells and Modules” research project was the final agreement focused on enhancing perovskite solar cell (PSC) technologies funded by the US Department of Energy's Solar Energy Technologies Office. The project was designed to address three crucial areas in PSC development: stability, manufacturability, and efficiency. The project was then structured around three main tasks, each targeting one of these strategic goals. The team of experienced researchers in these materials worked collaboratively to address the targets outlined in the technical work plan. building on existing PSC research while also exploring promising new concepts arising in the field. An overview of each primary task is summarized below: Task 1 Stability: This first task, aims to identify material characteristics and metrics that can help predict the primary degradation mechanisms impacting PSC stability. This involved developing specific device tests based on hypotheses regarding mechanisms impacting stability, including fast failure procedures to speed up PSC development and improvement. Various strategies to enhance stability, like incorporating additives, post-treatments, novel contact materials etc. were developed using this fast feedback approach. The relationships between indoor and outdoor stresses were also validated. Task 2 Manufacturability: This second task, focused on creating a scalable production process for PSCs. Initially the objective is to establish a best-known method for a 182 cm2 minimodule. However, given resource limitations, these metrics were modified to focus on the other goal of outlined in the TWP. Specifically, this task worked to demonstrate the transferability of this best-known method to another research institution. Work scope in this area was expanded to material purity and understanding of reagent/process relationships. Examination of other difficulties in PSC production and potential solutions for large-scale production were also evaluated. Given challenges observed in process transfer, work to develop data infrastructure and recording tools for processing of material and devices was then also prioritized in this task. Task 3 Efficiency: This task was focused on improvements to PCE, while still considering Task 1 and Task 2 goal. The efforts targeted a PCE greater than 22% with a T95 exceeding 1000 hours at 25°C in a nitrogen environment for lab-scale devices (approximately 0.1 cm2 devices) across a range of solar-relevant perovskite compositions, including wide-gap (around 1.7 eV) and low-gap (around 1.3 eV) materials, using standard metal contacts. This work then provides a foundation for MHP-based tandem efforts undertaken in other projects and the All-MHP tandem efforts outlined in this projects TWP. Work in this project emphasized disseminating its findings through peer-reviewed publications (PRP), conference presentations, and industrial collaborations. Significant products were produced in all these areas, over 53 peer reviewed publications, 32 conference presentations and industrial investment based on NLR assistance on precompetitive challenges. The team also developed significant intellectual property and awards for their technical excellence, innovations and leadership. The team also leveraged traditional and social media platforms to engage with stakeholders and the public.

14 SOLAR ENERGY↗

Normal Tissue Complication Probability Modeling of Acute Hematologic Toxicity in Patients Treated With Intensity-Modulated Radiation Therapy for Squamous Cell Carcinoma of the Anal Canal

Purpose: To identify dosimetric parameters that correlate with acute hematologic toxicity (HT) in patients with squamous cell carcinoma of the anal canal treated with definitive chemoradiotherapy (CRT). Methods and Materials: We analyzed 33 patients receiving CRT. Pelvic bone (PBM) was contoured for each patient and divided into subsites: ilium, lower pelvis (LP), and lumbosacral spine (LSS). The volume of each region receiving at least 5, 10, 15, 20, 30, and 40 Gy was calculated. Endpoints included grade {>=}3 HT (HT3+) and hematologic event (HE), defined as any grade {>=}2 HT with a modification in chemotherapy dose. Normal tissue complication probability (NTCP) was evaluated with the Lyman-Kutcher-Burman (LKB) model. Logistic regression was used to test associations between HT and dosimetric/clinical parameters. Results: Nine patients experienced HT3+ and 15 patients experienced HE. Constrained optimization of the LKB model for HT3+ yielded the parameters m = 0.175, n = 1, and TD{sub 50} = 32 Gy. With this model, mean PBM doses of 25 Gy, 27.5 Gy, and 31 Gy result in a 10%, 20%, and 40% risk of HT3+, respectively. Compared with patients with mean PBM dose of <30 Gy, patients with mean PBM dose {>=}30 Gy had a 14-fold increase in the odds of developing HT3+ (p = 0.005). Several low-dose radiation parameters (i.e., PBM-V10) were associated with the development of HT3+ and HE. No association was found with the ilium, LP, or clinical factors. Conclusions: LKB modeling confirms the expectation that PBM acts like a parallel organ, implying that the mean dose to the organ is a useful predictor for toxicity. Low-dose radiation to the PBM was also associated with clinically significant HT. Keeping the mean PBM dose <22.5 Gy and <25 Gy is associated with a 5% and 10% risk of HT, respectively.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ZINC MITIGATION INTERIM REPORT - THERMODYNAMIC STUDY

An experimental program was initiated in order to develop and validate conditions that will effectively trap Zn vapors that are released during extraction. The proposed work is broken down into three tasks. The first task is to determine the effectiveness of various pore sizes of filter elements. The second task is to determine the effect of filter temperature on zinc vapor deposition. The final task is to determine whether the zinc vapors can be chemically bound. The approach for chemically binding the zinc vapors has two subtasks, the first is a review of literature and thermodynamic calculations and the second is an experimental approach using the best candidates. This report details the results of the thermodynamic calculations to determine feasibility of chemically binding the zinc vapors within the furnace module, specifically the lithium trap (1). A review of phase diagrams, literature, and thermodynamic calculations was conducted to determine if there are suitable materials to capture zinc vapor within the lithium trap of the extraction basket. While numerous elements exist that form compounds with zinc, many of these also form compounds with hydrogen or the water that is present in the TPBARs. This relatively comprehensive review of available data indicates that elemental cobalt and copper and molybdenum trioxide (MoO3) may have the requisite properties to capture zinc and yet not be adversely affected by the extraction gases and should be considered for testing.

08 HYDROGEN↗

A New On-the-Fly Sampling Method for Incoherent Inelastic Thermal Neutron Scattering Data in MCNP6

At thermal energies, the scattering of neutrons in a system is complicated by the comparable velocities of the neutron and target, resulting in competing upscattering and downscattering events. The neutron wavelength is also similar in size to the target's interatomic spacing making the scattering process a quantum mechanical problem. Because of the complicated nature of scattering at low energies, the thermal data files in ACE format used in continuous-energy Monte Carlo codes are quite large { on the order of megabytes for a single temperature and material. In this paper, a new storage and sampling method is introduced that is orders of magnitude less in size and is used to sample scattering parameters at any temperature on-the-fly. In addition to the reduction in storage, the need to pre-generate thermal scattering data tables at fine temperatures has been eliminated. This is advantageous for multiphysics simulations which may involve temperatures not known in advance. A new module was written for MCNP6 that bypasses the current S(α,β) table lookup in favor of the new format. The new on-the-fly sampling method was tested for graphite for two benchmark problems at ten temperatures: 1) an eigenvalue test with a fuel compact of uranium oxycarbide fuel homogenized into a graphite matrix, 2) a surface current test with a \broomstick" problem with a monoenergetic point source. The largest eigenvalue difference was 152pcm for T= 1200K. For the temperatures and incident energies chosen for the broomstick problem, the secondary neutron spectrum showed good agreement with the traditional S(α,β) sampling method. These preliminary results show that sampling thermal scattering data on-the-fly is a viable option to eliminate both the storage burden of keeping thermal data at discrete temperatures and the need to know temperatures before simulation runtime.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

0.22 THz wideband sheet electron beam traveling wave tube amplifier: Cold test measurements and beam wave interaction analysis

In this paper, we describe micro-fabrication, RF measurements, and particle-in-cell (PIC) simulation modeling analysis of the 0.22 THz double-vane half period staggered traveling wave tube amplifier (TWTA) circuit. The TWTA slow wave structure comprised of two sections separated by two sever ports loaded by loss material, with integrated broadband input/output couplers. The micro-metallic structures were fabricated using nano-CNC milling and diffusion bonded in a three layer process. The 3D optical microscopy and SEM analysis showed that the fabrication error was within 2-3 {mu}m and surface roughness was measured within 30-50 nm. The RF measurements were conducted with an Agilent PNA-X network analyzer employing WR5.1 T/R modules with a frequency range of 178-228 GHz. The in-band insertion loss (S{sub 21}) for both the short section and long section (separated by a sever) was measured as {approx}-5 dB while the return loss was generally around {approx}-15 dB or better. The measurements matched well with the S-matrix simulation analysis that predicted a 3 dB bandwidth of {approx}45 GHz with an operating frequency at 220 GHz. However, the measured S{sub 21} was {approx}3 dB less than the design values, and is attributed to surface roughness and alignment issues. The confirmation measurements were conducted over the full frequency band up to 270 GHz employing a backward wave oscillator (BWO) scalar network analyzer setup employing a BWO in the frequency range 190 GHz-270 GHz. PIC simulations were conducted for the realistic TWT output power performance analysis with incorporation of corner radius of 127 {mu}m, which is inevitably induced by nano-machining. Furthermore, the S{sub 21} value in both sections of the TWT structure was reduced to correspond to the measurements by using a degraded conductivity of 10% International Annealed Copper Standard. At 220 GHz, for an elliptic sheet electron beam of 20 kV and 0.25 A, the average output power of the tube was predicted to be reduced from 90 W (for ideal conductivity/design S-parameters) to 70 W (for the measured S-parameters/inferred conductivity) for an average input power of 50 mW. The gain of the tube remains reasonable: {approx}31.4 dB with an electronic efficiency of {approx}1.4%. The same analysis was also conducted for several frequencies between 190 GHz-260 GHz. This detailed realistic PIC analysis demonstrated that this nano-machined TWT circuit has slightly reduced S-parameters and output power from design, but within an acceptable range and still have promising output power, gain, and band width as required. Thus, we expect to meet the specifications of 1000 W-GHz for the darpa program goals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing quantitative capabilities for a scanning microwave impedance microscope

Currently no instrument exists to quantitatively measure electrical properties (dielectric constant and conductivity) on sub-micron regions, a capability of extreme importance to measure the functioning of sub-micron structures and devices. In particular, such electrical measurements could support the development and manufacture of advanced energy related materials used in technologies such as photovoltaic cells, fuel cells and advanced batteries, thereby increasing performance and/or lowering production costs. The goal of this project is to develop microwave imaging add-on modules and probes capable of quantitatively measuring the electrical properties of small regions of a material using microwaves. These modules for scanning probe microscopes, such as atomic force microscopes, make use of the near-field interaction between the exciting microwaves and a material and can resolve regions 10 nanometers in size (less than a million atoms) with little perturbation of the material. In Phase 1 commercial probes and modified hardware were used to establish the feasibility of using microwave imaging systems to quantify local permittivity and conductivity. Repeatable measurements that vary in a systematic way with electrical parameters were obtained from a variety of samples. In Phase 2 research prototypes of the needed hardware and probes were developed and their performance against test structures and real-world samples was demonstrated. Result of this research project include demonstration of quantification of both permittivity and doping level at precisions up to 10% using multiple technical approaches. The level of performance and ease of use meets market expectations and the technology and protocols researched under this grant are currently being commercialized. Quantitative capabilities of this sort will provide a key capability to energy related technologies, and to a wide variety of semiconductor, biological, and materials science applications. Applications include both materials research in academic and industrial labs, as well as manufacturing applications. In a manufacturing environment the quantitative measurement and imaging capabilities could be used both as metrology for process control and as a tool for failure analysis and yield improvement.

36 MATERIALS SCIENCE↗