Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Low Repetition-Rate, High-Resolution Femtosecond Transmission Electron Microscopy

Spatial and energy resolutions of state-of-the-art transmission electron microscopes (TEMs) have surpassed 50 pm and 5 meV. However, with respect to the time domain, even the fastest detectors combined with the brightest sources may only be able to reach the microsecond timescale. Thus, conventional methods are incapable of resolving myriad fundamental ultrafast (i.e., attosecond to picosecond) atomic-scale dynamics. The successful demonstration of femtosecond (fs) laser-based (LB) ultrafast transmission electron microscopy (UEM) nearly 20 years ago provided a means to span this nearly 10-order-of-magnitude temporal gap. While nanometer-picosecond UEM studies of dynamics are now well established, ultrafast Å-scale imaging has gone largely unrealized. Further, while instrument development has rightly been an emphasis, and while new modalities and uses of pulsed-beam TEM continue to emerge, the overall chemical and materials application space has been only modestly explored to date. In this Perspectives article, we argue that these apparent shortfalls can be attributed to a simple lack of data and detail. We speculate that present work and continued growth of the field will ultimately lead to the realization that Å-scale fs dynamics can indeed be imaged with minimally modified UEM instrumentation and with repetition rates (f rep ) below - and perhaps even well below - 1 MHz. We further argue that use of low f rep , whether for LB UEM or for chopped/bunched beams, significantly expands the accessible application space. Furthermore, this calls for systematically establishing modality-specific limits so that especially promising technologies can be pursued, thus ultimately facilitating broader adoption as individual instrument capabilities expand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification, isolation, and characterization of a novel type of Fukushima-derived microparticle

Abstract In the course of the Fukushima nuclear accident, radionuclides were released in various forms, including so-called radiocesium-bearing microparticles (CsMP). So far, four types of CsMP were described: Type A is smaller in size (< 10 μm), Types B, C, and D are larger (> 100 μm). In this work, we present a novel type of CsMP (proclaimed Type E). Three particles of Type E were extracted from a contaminated blade of grass that was sampled 1.5 km from the Fukushima Daiichi nuclear power plant in late 2011. They were located using autoradiography, isolated using an optical microscope and micromanipulator, and characterized using scanning electron microscopy, energy dispersive x-ray spectroscopy, and low-level gamma-ray spectrometry. Type E CsMPs are 10–20 μm in size and exhibit an unusually low and barely detectable 137 Cs activity of only ≤ 10 mBq per particle. Their brittle and fragile character may indicate a high surface tension.

137Cs↗

Effect of Dual-Phase Heat Treatment on Microstructure and Mechanical Properties of S135 High-Strength Drill Pipe Steel

Effect of dual-phase heat treatment (DPHT) on microstructure and mechanical properties of S135 high-strength drill pipe steel was studied by means of optical microscope, scanning electron microscope and mechanical property testing. The results show that the ferrite–martensite dual-phase microstructures were obtained at 760-800 °C. With increase in DPHT temperature, the volume fraction of martensite increases and the ferrite decreases. When the DPHT temperature is low, martensite is distributed as an island on the ferrite matrix, and ferrite is distributed as an island on the martensite matrix when the DPHT temperature is high. The hardness and strength of the steel increase, the plasticity and toughness decrease, the steel changes from ductile fracture to brittle fracture and the micro-fracture morphology changes from dimple to cleavage with increase in DPHT temperature. The strain hardening exponent of the as-received steel shows one ‘n’ value, but exhibits two ‘n’ values after DPHT. When the DPHT temperature is 750 °C, the relative content of martensite in the duplex structure is 15-20%, and the impact energy of the steel is similar to that of the as-received S135 drill pipe steel, and the strength is increased by about 15%. Micropores and micro-cracks on the subsurface of tensile fracture surface are mainly formed at the martensite/ferrite phase boundary or in the martensite slit.

36 MATERIALS SCIENCE↗

Effect of Chromium Content on Microstructure, Hardness, and Wear Resistance of As-Cast Fe-Cr-B Alloy

The effects of chromium content on microstructure, hardness and wear resistance of as-cast Fe-xCr-1.0B (x = 0, 4, 8, 12, 16, 20) alloys were investigated by means of optical microscope (OM), scanning electron microscope (SEM), x-ray diffractometer (XRD), hardness tester and ring block wear tester. The results showed that the microstructures of chromium-free alloy were mainly composed of pearlite, ferrite, and eutectic borocarbides, and the hardness was very low, only 18.8 HRC. With the increase in chromium content, the matrix of as-cast Fe-Cr-B alloy gradually began to transform from pearlite and ferrite to lath martensite, and the type of borocarbides changed from Fe{sub 2}(B, C) to M{sub 2}(B, C), M{sub 7}(C, B){sub 3} and M{sub 23}(C, B){sub 6} (M = Fe, Cr). When the chromium content was 12 wt.%, the hardness of alloy reached the highest value of 61.1 HRC, and the wear resistance of alloy was the best. The results of worn surface analysis showed that the wear failure of as-cast Fe-Cr-B alloy was mainly caused by multiple plastic deformation and micro-cutting.

36 MATERIALS SCIENCE↗

Surface treated polypropylene (PP) fibres for reinforced concrete

Surface treatments on a polypropylene (PP) fibre have contributed to the improvement of fibre/concrete adhesion in fibre-reinforced concrete. The treatments to the PP fibre were characterized by contact angle measurements, ATR-IR and XPS to analyse chemical alterations. The surface topography and fibre/concrete interaction were analysed by several microscopic techniques, namely optical petrographic, and scanning electron microscopy. Treatment modified the surface chemistry and topography of the fibre by introducing sodium moieties and created additional fibre surface roughness. Modifications in the fibre surface led to an increase in the adhesion properties between the treated fibres and concrete and an improvement in the mechanical properties of the fibre-reinforced concrete composite as compared to the concrete containing untreated PP fibres. Compatibility with the concrete and increased roughness and mineral surface was also improved by nucleated portlandite and ettringite mineral association anchored on the alkaline PP fibre surface, which is induced during treatment.

36 MATERIALS SCIENCE↗

Characterization of boron carbide particulate reinforced in situ copper surface composites synthesized using friction stir processing

Friction stir processing has evolved as a novel solid state technique to fabricate surface composites. The objective of this work is to apply the friction stir processing technique to fabricate boron carbide particulate reinforced copper surface composites and investigate the effect of B{sub 4}C particles and its volume fraction on microstructure and sliding wear behavior of the same. A groove was prepared on 6 mm thick copper plates and packed with B{sub 4}C particles. The dimensions of the groove was varied to result in five different volume fractions of B{sub 4}C particles (0, 6, 12, 18 and 24 vol.%). A single pass friction stir processing was done using a tool rotational speed of 1000 rpm, travel speed of 40 mm/min and an axial force of 10 kN. Metallurgical characterization of the Cu/B{sub 4}C surface composites was carried out using optical microscope and scanning electron microscope. The sliding wear behavior was evaluated using a pin-on-disk apparatus. Results indicated that the B{sub 4}C particles significantly influenced the area, dispersion, grain size, microhardness and sliding wear behavior of the Cu/B{sub 4}C surface composites. When the volume fraction of B{sub 4}C was increased, the wear mode changed from microcutting to abrasive wear and wear debris was found to be finer. Highlights: • Fabrication of Cu/B{sub 4}C surface composite by friction stir processing • Analyzing the effect of B{sub 4}C particles on the properties of Cu/B4C surface composite • Increased volume fraction of B{sub 4}C particles reduced the area of surface composite. • Increased volume fraction of B{sub 4}C particles enhanced the microhardness and wear rate. • B{sub 4}C particles altered the wear mode from microcutting to abrasive.

36 MATERIALS SCIENCE↗

Microstructure and tensile properties of laser engineered net shaped reduced activation ferritic/martensitic steel

Highlights: • A RAFM steel has been successfully manufactured by laser engineered net shaping (LENS), which is one of laser additive manufacturing technologies. • Columnar dendrites in vertical section and a mixture of equiaxed and columnar grains in horizontal section have been observed. • The anisotropic tensile properties are induced by LENS process, which can be eliminated well through the heat treatment. - Abstract: A laser additive manufacturing technique, laser engineered net shaping (LENS), was successfully applied to manufacture a reduced activation ferritic/martensitic (RAFM) steel with nominal composition of Fe-9Cr-0.11C-1.5W-0.4Mn-0.2V-0.12Ta (wt%). The as-deposited LENS-RAFM steels were normalized and tempered. The microstructures of as-deposited and heat treated LENS-RAFM steels were characterized by using optical microscope (OM), scanning electron microscope (SEM) and transmission electron microscope (TEM). The tensile tests of as-deposited and heat treated samples in different directions were carried out at room temperature and 873 K. The results showed that columnar dendrites grow epitaxially along the direction of deposition in vertical section (YOZ) and a mixture of equiaxed and columnar grains appears in horizontal section (XOY). No precipitates are observed in the as-deposited sample while Cr-rich M{sub 23}C{sub 6} and Ta-rich MX type carbides appear in the heat treated sample. The as-deposited sample showed anisotropic tensile properties which could be eliminated by heat treatment. The tensile strength of the LENS-RAFM steel is similar to conventional RAFM steels such as EUROFER 97 and CLAM.

36 MATERIALS SCIENCE↗

Challenging endeavor to integrate gallium and carbon via direct bonding to evolve GaN on diamond architecture

Here this paper depicts efforts for fabricating GaN on diamond microstructure through direct bonding between Ga and C, while excluding the use of adhesive interlayer during spark plasma sintering (SPS) process. The resulting GaN on diamond architecture is seemingly successful, as suggested by macroscopic morphological observations. The microscopic inspection using high-resolution transmission electron microscopy (HRTEM), however, shows a unique, off-the-chart interlayer configuration, wherein the components are migrated, etched, or fused to tentatively form multiple crystal phases. These phases can be constructed based on their utmost stabilities among all possible phases thermodynamically driven under or near the SPS conditions.

36 MATERIALS SCIENCE↗

A compact surface decontamination system for surface-sensitive magnetic imaging

A surface decontamination system for application in surface sensitive magnetic imaging tools, such as a spin-polarized scanning electron microscope, is described. Adsorbed contaminant is chemically decomposed with the use of active oxygen in a compact vacuum chamber mounted in a microscope. The present method is especially suitable for fragile magnetic surfaces of complex oxide materials to which the conventional physical etching widely used for magnetic metals could cause serious structural damage. We have succeeded in detecting magnetic signals from a decontaminated oxide surface and visualizing domain images with sufficient magnetic contrast to analyze detailed domain structures.

36 MATERIALS SCIENCE↗

In vivo virtual intraoperative surgical photoacoustic microscopy

We developed a virtual intraoperative surgical photoacoustic microscopy system by combining with a commercial surgical microscope and photoacoustic microscope (PAM). By sharing the common optical path in the microscope and PAM system, we could acquire the PAM and microscope images simultaneously. Moreover, by employing a beam projector to back-project 2D PAM images onto the microscope view plane as augmented reality, the conventional microscopic and 2D cross-sectional PAM images are concurrently mapped on the plane via an ocular lens of the microscope in real-time. Further, we guided needle insertion into phantom ex vivo and mice skins in vivo.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isothermal oxidation behavior of ternary Zr-Nb-Y alloys at high temperature

The effect of yttrium content on isothermal oxidation behavior of Zr-2,5%Nb-0,5%Y, Zr-2,5%Nb-1%Y Zr-2,5%Nb-1,5%Y alloy at high temperature has been studied. High temperature oxidation carried out at tube furnace in air at 600,700 and 800°C for 1 hour. Optical microscope is used for microstructure characterization of the alloy. Oxidized and un oxidized specimen was characterized by x-ray diffraction. In this study, kinetic oxidation of Zr-2,5%Nb with different Y content at high temperature has also been studied. Characterization by optical microscope showed that microstructure of Zr-Nb-Y alloys relatively unchanged and showed equiaxed microstructure. X-ray diffraction of the alloys depicted that the oxide scale formed during oxidation of zirconium alloys is monoclinic ZrO2 while unoxidised alloy showed two phase α and β phase. SEM-EDS examination shows that depletion of Zr composition took place under the oxide layer. Kinetic rate of oxidation of zirconium alloy showed that increasing oxidation temperature will increase oxidation rate but increasing yttrium content in the alloys will decrease oxidation rate.

36 MATERIALS SCIENCE↗

High temperature oxidation behavior of austenitic stainless steel AISI 304 in steam of nanofluids contain nanoparticle ZrO2

The objective of this study is to evaluate high temperature oxidation behavior of austenitic stainless steel SS 304 in steam of nanofluids contain nanoparticle ZrO{sub 2}. The oxidation was performed at high temperatures ranging from 600 to 800°C. The oxidation time was 60 minutes. After oxidation the surface of the samples was analyzed by different methods including, optical microscope, scanning electron microscope (SEM) and X-ray diffraction (XRD). X-ray diffraction examination show that the oxide scale formed during oxidation of stainless steel AISI 304 alloys is dominated by iron oxide, Fe{sub 2}O{sub 3}. Minor element such as Cr{sub 2}O{sub 3} is also appeared in the diffraction pattern. Characterization by optical microscope showed that cross section microstructure of stainless steel changed after oxidized with the oxide scale on the surface stainless steels. SEM and x-ray diffraction examination show that the oxide of ZrO{sub 2} appeared on the surface of stainless steel. Kinetic rate of oxidation of austenite stainless steel AISI 304 showed that increasing oxidation temperature and time will increase oxidation rate.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Four-probe measurements with a three-probe scanning tunneling microscope

We present an ultrahigh vacuum (UHV) three-probe scanning tunneling microscope in which each probe is capable of atomic resolution. A UHV JEOL scanning electron microscope aids in the placement of the probes on the sample. The machine also has a field ion microscope to clean, atomically image, and shape the probe tips. The machine uses bare conductive samples and tips with a homebuilt set of pliers for heating and loading. Automated feedback controlled tip-surface contacts allow for electrical stability and reproducibility while also greatly reducing tip and surface damage due to contact formation. The ability to register inter-tip position by imaging of a single surface feature by multiple tips is demonstrated. Four-probe material characterization is achieved by deploying two tips as fixed current probes and the third tip as a movable voltage probe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a size-selected nanocluster deposition facility and in situ characterization of grown films by x-ray photoelectron spectroscopy

We report here on a newly installed gas aggregation type nanocluster deposition unit based on magnetron sputtering ion source with mass selection of the clusters by quadrupole mass filter. The system is ultra high vacuum compatible and is equipped with an in situ X-ray Photoelectron Spectroscopy facility, giving compositional information of the films formed by nanoclusters deposition on a substrate. Detailed descriptions and working of the components of the system are presented. For the characterization of the nanocluster source and associated mass filter for size selected clusters, the dependence of output performance as a function of aggregation length, sputter gas flow and magnetron power of the cluster source have been studied. Copper nanoclusters deposited on Silicon (100) surface and on transmission electron microscope grids are, respectively, studied with scanning electron microscopy and transmission electron microscopy for the morphology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controlled synthesis and magnetic properties of monodispersed ceria nanoparticles

In the present study, monodispersed CeO{sub 2} nanoparticles (NPs) of size 8.5 ± 1.0, 11.4 ± 1.0 and 15.4 ± 1.0 nm were synthesized using the sol-gel method. Size-dependent structural, optical and magnetic properties of as-prepared samples were investigated by X-ray diffraction (XRD), field emission scanning electron microscope (FE-SEM), high resolution transmission electron microscopy (HR-TEM), ultra-violet visible (UV-VIS) spectroscopy, Raman spectroscopy and vibrating sample magnetometer (VSM) measurements. The value of optical band gap is calculated for each particle size. The decrease in the value of optical band gap with increase of particle size may be attributed to the quantum confinement, which causes to produce localized states created by the oxygen vacancies due to the conversion of Ce{sup 4+} into Ce{sup 3+} at higher calcination temperature. The Raman spectra showed a peak at ∼461 cm{sup -1} for the particle size 8.5 nm, which is attributed to the 1LO phonon mode. The shift in the Raman peak could be due to lattice strain developed due to variation in particle size. Weak ferromagnetism at room temperature is observed for each particle size. The values of saturation magnetization (Ms), coercivity (Hc) and retentivity (Mr) are increased with increase of particle size. The increase of Ms and Mr for larger particle size may be explained by increase of density of oxygen vacancies at higher calcination temperature. The latter causes high concentrations of Ce{sup 3+} ions activate more coupling between the individual magnetic moments of the Ce ions, leading to an increase of Ms value with the particle size. Moreover, the oxygen vacancies may also produce magnetic moment by polarizing spins of f electrons of cerium (Ce) ions located around oxygen vacancies, which causes ferromagnetism in pure CeO{sub 2} samples.

36 MATERIALS SCIENCE↗

Development of scanning electron and x-ray microscope

We have developed a new type of microscope possessing a unique feature of observing both scanning electron and X-ray images under one unit. Unlike former X-ray microscopes using SEM [1, 2], this scanning electron and X-ray (SELX) microscope has a sample in vacuum, thus it enables one to observe a surface structure of a sample by SEM mode, to search the region of interest, and to observe an X-ray image which transmits the region. For the X-ray observation, we have been focusing on the soft X-ray region from 280 eV to 3 keV to observe some bio samples and soft materials. The resolutions of SEM and X-ray modes are 50 nm and 100 nm, respectively, at the electron energy of 7 keV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electric Field Tuned Crossover from Classical to Weakly Localized Quantum Transport in Electron Doped SrTiO3

Electron gases created by modulating the charge density near interfaces and surfaces of insulating SrTiO{sub 3} offer a wide range of tunable behavior. Here, we utilize the nonlinear dielectric response of SrTiO{sub 3} to electrostatically manipulate the spatial confinement of an electron gas relative to an interface, where scattering is enhanced. Magnetotransport measurements reveal that the electron gas can be tuned from weakly localized to classical transport regimes. This crossover in transport demonstrates that elastic scattering can be electrostatically controlled, providing another degree of tunability for electron gases in SrTiO{sub 3}.

36 MATERIALS SCIENCE↗