Search NASA⌕ Search

SEARCH · Search NASA

Results for “Morris method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Optimizing Transmission of Acoustic Signals to Monitor Internal Conditions of Canisters for Dry Storage of Commercial Spent Nuclear Fuel

Safe storage of spent nuclear fuel (SNF) is critical to the nuclear fuel cycle and the future of nuclear energy. In the United States, SNF is stored primarily via two methods regulated by the U.S. Nuclear Regulatory Commission: wet storage in SNF pools and dry storage in dry cask storage systems (DCSSs). After about five years of cooling in spent fuel pools, the fuel assemblies are transferred into DCSSs, and the systems are filled with helium and sealed by welding. Deterioration of conditions inside of a DCSS is reflected in changes in the internal gas properties; this motivates the development of acoustic techniques to monitor internal gas properties, over extended storage periods, using sensors mounted on the exterior of the storage packages. However, a major challenge in collecting acoustic signals is the impedance mismatch between the steel canister shell and the gas. Only a small fraction of the ultrasonic signal can be transmitted through the gas medium. This paper documents experimental studies conducted on a full-scale canister mock-up to capture the gas-borne signals. Damping materials were pasted on the outside, and blocking and unblocking tests were conducted to identify the gas-borne signal. The results show that the excitation frequency plays an important role in maximizing the gas-borne signals. The gas-borne signal was successfully detected at around the theoretical time-of-flight. A high signal-to-noise ratio was achieved in the measurements. Next, the acoustic impedance matching layers were introduced, and the gas signal was drastically improved compared with that using no AIM layers.

Spent nuclear fuel (SNF), Canisters, Internal cond↗

The Solar Orbiter SPICE Instrument An Extreme UV imaging spectrometer

Aims. The Spectral Imaging of the Coronal Environment (SPICE) instrument is a high-resolution imaging spectrometer operating at extreme ultraviolet wavelengths. In this paper, we present the concept, design, and pre-launch performance of this facility instrument on the ESA/NASA Solar Orbiter mission. Methods. The goal of this paper is to give prospective users a better understanding of the possible types of observations, the data acquisition, and the sources that contribute to the instrument’s signal. Results. The paper discusses the science objectives, with a focus on the SPICE-specific aspects, before presenting the instrument’s design, including optical, mechanical, thermal, and electronics aspects. This is followed by a characterisation and calibration of the instrument’s performance. The paper concludes with descriptions of the operations concept and data processing. Conclusions. The performance measurements of the various instrument parameters meet the requirements derived from the mission’s science objectives. The SPICE instrument is ready to perform measurements that will provide vital contributions to the scientific success of the Solar Orbiter mission.

M. Anderson↗

Unresectable Squamous Cell Carcinoma of the Lung: An Outcomes Study

Purpose: To report survival and control rates in patients with inoperable squamous cell carcinoma (SCC). Methods and Materials: Two hundred seventy-five patients with inoperable squamous cell carcinoma of the lung (Stages I-IIIB) who received radiotherapy alone or combined with chemotherapy given with curative intent at University of Florida between 1963 and 2006 were retrospectively analyzed. Results: Overall survival (OS) at 5 years for Stages I, II, and III was 10%, 14%, and 7% (p = 0.0034); local-regional control at 5 years was 51%, 38%, and 29% (p = 0.0003); and freedom from metastases at 5 years was 81%, 60%, and 65% (p = 0.0689), respectively. Patients who received doses {>=} 65 Gy had improved cause-specific survival (CSS), OS, and metastasis-free survival at 5 years compared with those who received doses < 65 Gy. Five-year regional control was significantly improved with twice-daily vs. once-daily treatment (37% vs. 14%, p = 0.02). Chemotherapy significantly improved 5-year regional control (36% for patients who received chemotherapy vs. 13% for those who did not; p = 0.01). Conclusions: Dose escalation, accelerated fractionation, and combined modality therapies improve outcomes in SCC of the lung. Our review of the literature highlights the different natural history for SCC vs. other non-small cell lung cancers and emphasizes the importance of tailoring treatment strategies to individual patients. At University of Florida, we have begun treating unresectable Stage III patients with SCC of the lung using 69.6 Gy twice daily with concurrent chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multimodality Local Therapy for Retroperitoneal Sarcoma

Purpose: Soft-tissue sarcomas of the retroperitoneum are rare tumors comprising less than 1% of all malignancies. Although surgery continues as the mainstay of treatment, the large size of these tumors coupled with their proximity to critical structures make resection with wide margins difficult to achieve. The role and timing of radiotherapy are controversial. This study updates our institutional experience using multimodality local therapy for resectable retroperitoneal sarcoma and identifies prognostic factors impacting disease control and survival. Methods and Materials: Between 1974 and 2007, 58 patients with nonmetastatic retroperitoneal sarcoma were treated with surgery and radiation at University of Florida. The median age at radiotherapy was 57 years old (range, 18-80 years). Forty-two patients received preoperative radiotherapy and 16 received postoperative radiotherapy. Nineteen patients received 1.8 Gy once daily and 39 patients received 1.2 Gy twice daily. Variables analyzed for prognostic value included age, grade, kidney involvement, histology, de novo versus recurrent presentation, tumor diameter, margin status, radiotherapy sequencing (preoperative vs. postoperative), total radiation dose, fractionation scheme, and treatment era. Results: The 5-year overall survival, cause-specific survival, and local control rates were 49%, 58%, and 62%, respectively. Nearly two-thirds of disease failures involved a component of local progression. On multivariate analysis, only margin status was significantly associated with improved 5-year local control (85%, negative margins; 63%, microscopic positive margins; 0%, gross positive margins; p < 0.0001) and 5-year overall survival (64%, negative margins; 56%, microscopic positive margins; 13%, gross positive margins; p = 0.0012). Thirty-one Grade 3 or greater toxicities were observed in 22 patients, including two treatment-related deaths (3%). Conclusion: For retroperitoneal sarcoma, local control remains a challenge and combined-modality therapy may be associated with significant acute and late morbidity. Our patterns of failure data suggest that improvements in local control may translate into a survival benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The De-Icing Comparison Experiment – ARM Contribution (DICEXACO) Field Campaign Report

Longwave and shortwave radiative fluxes are fundamental quantities regularly observed globally using broadband radiometers. In regions conducive to frost, rime, and snow, ice frequently builds up on sensor windows, contaminating measurements. Since icing occurs under particular meteorological conditions, associated data loss constitutes a climatological bias. Furthermore, the signal caused by ice is difficult to distinguish from that of clouds, hampering efforts to identify contaminated data in post-processing. Because of the sensitivity of radiometers to internal temperature instabilities, there are limitations to using heat as a de-icing method, and consequently substantial amounts of data are lost. The De-Icing Comparison Experiment (D-ICE) was a campaign carried out at $Utqia\dot{g}vik$ (formerly known as Barrow) and Oliktok Point, Alaska, from August 2017 to July 2018. The purpose of D-ICE was to evaluate ventilation and heating technologies developed to mitigate radiometer icing. D-ICE consisted of 20 pyranometers and 5 pyrgeometers operating in various ventilator housings alongside operational stations run by the NOAA Global Monitoring Division (GMD) at NOAA’s Barrow Atmospheric Baseline Observatory. D-ICE also evaluated the sky radiometer (SKYRAD) systems at the U.S. Department of Energy’s Atmospheric Radiation Measurement (ARM) North Slope of Alaska (NSA) and Oliktok Point (OLI; third ARM Mobile Facility [AMF3]) observatories. In total, 34 systems were evaluated (8 of which were SKYRAD radiometers). All radiometers were monitored continuously using cameras, and a total of more than one million images of sensor domes were archived collectively between the stations. Data collected as part of D-ICE by NOAA can be found through the project web page, https://www.esrl.noaa.gov/psd/arctic/d-ice/. The DICEXACO component of D-ICE (https://www.arm.gov/research/campaigns/nsa2017dicexaco) are the images collected at 10-min intervals at both OLI and NSA and are the subject of this report. Two cameras were installed at each ARM station, one directed towards the SKYRAD tracker and the other towards the SKYRAD global precision spectral pyranometer (PSP).

Oliktok Point, North Slope of Alaska, SKYRAD, pyra↗

Carotid-Sparing Intensity-Modulated Radiotherapy for Early-Stage Squamous Cell Carcinoma of the True Vocal Cord

Purpose: To compare radiation doses to carotid arteries among various radiotherapy techniques for treatment of early-stage squamous cell carcinoma (SCC) of the true vocal cords. Methods and Materials: Five patients were simulated using computed tomography (CT). Clinical and planning target volumes (PTV) were created for bilateral and unilateral stage T1 vocal cord cancers. Planning risk volumes for the carotid arteries and spinal cord were delineated. For each patient, three treatment plans were designed for bilateral and unilateral target volumes: opposed laterals (LATS), three-dimensional conformal radiotherapy (3DCRT), and intensity-modulated radiotherapy (IMRT), for a total of 30 plans. More than 95% of the PTV received the prescription dose (63Gy at 2.25 Gy per treatment). Results: Carotid dose was lowest with IMRT. With a bilateral vocal cord target, the median carotid dose was 10Gy with IMRT vs. 25 Gy with 3DCRT and 38 Gy with LATS (p < 0.05); with a unilateral target, the median carotid dose was 4 Gy with IMRT vs. 19 Gy with 3DCRT and 39 Gy with LATS (p < 0.05). The dosimetric tradeoff with IMRT is a small area of high dose in the PTV. The worst heterogeneity results were at a maximum point dose of 80 Gy (127%) in a unilateral target that was close to the carotid. Conclusions: There is no question that IMRT can reduce the dose to the carotid arteries in patients with early-stage vocal cord cancer. The question is whether the potential advantage of reducing the carotid dose outweighs the risk of tumor recurrence due to contouring errors and organ motion and the risk of complications from dose heterogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spinal and Paraspinal Ewing Tumors

Purpose: To perform a review of the 40-year University of Florida experience treating spinal and paraspinal Ewing tumors. Patients and Methods: A total of 27 patients were treated between 1965 and 2007. For local management, 21 patients were treated with radiotherapy (RT) alone and 6 with surgery plus RT. All patients with metastatic disease were treated with RT alone. The risk profiles of each group were otherwise similar. The median age was 17 years, and the most frequent subsite was the sacral spine (n = 9). The median potential follow-up was 16 years. Results: The 5-year actuarial overall survival, cause-specific survival, and local control rate was 62%, 62%, and 90%, respectively. For the nonmetastatic subset (n = 22), the 5-year overall survival, cause-specific survival, and local control rate was 71%, 71%, and 89%, respectively. The local control rate was 84% for patients treated with RT alone vs. 100% for those treated with surgery plus RT. Patients who were >14 years old and those who were treated with intensive therapy demonstrated superior local control. Of 9 patients in our series with Frankel C or greater neurologic deficits at presentation, 7 experienced a full recovery with treatment. Of the 27 patients, 37% experienced Common Toxicity Criteria Grade 3 or greater toxicity, including 2 deaths from sepsis. Conclusion: Aggressive management of spinal and paraspinal Ewing tumors with RT with or without surgery results in high toxicity but excellent local control and neurologic outcomes. Efforts should be focused on identifying disease amenable to combined modality local therapy and improving RT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight available printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.

60 APPLIED LIFE SCIENCES↗

SU-E-J-07: IGRT Gently: Evaluating Imaging Dose in Phantoms of Different Sizes

Purpose: IGRT imaging procedures have emerged as a common method of patient position verification in radiotherapy, though imaging dose is generally neglected in the treatment plan. Consequently, evaluating and optimizing the dose from these procedures is worthwhile. This process is especially important for children, who are more radiosensitive than adults. The aim of this work was to gain some understanding of the relative doses involved with various XVI-preset parameters for an “adult” and “child” phantom set, with the hopes that imaging dose for a child can be reduced. Methods: 32 and 16cm CTDI-phantoms were used as surrogates for adult and child torsos, respectively. Dose was measured in the central and peripheral chamber positions of the phantoms. CBCT scans were made for both phantoms using Elekta’s Chest-preset to establish a dose baseline. The child-phantom was then scanned using the Elekta Head and Neck (HN) preset. A modified HN-preset (named Peds Abd-pelvis) was also created with a doubled mAs to maintain a reduction in dose to the child-phantom (relative to the baseline), while providing clinically-usable image quality. Results: The baseline dose to the child-phantom from the Chest-preset was 310% that of the adult-phantom for the center chamber position and 150% at the periphery. An average dose reduction of 97% was obtained in the childphantom by switching from the Chest-preset to the HN-preset, while the Peds Abd-pelvis-preset similarly reduced the dose by an average of 92%. Conclusion: XVI-preset parameters significantly affect dose, and should be optimized to reduce dose, while ensuring clinically-usable image quality. Using a modified imaging preset (Peds Abd-pelvis-preset) greatly reduced the dose to the child-phantom compared to the dose for the Chest-preset for both the child and adult-phantoms. This outcome provides support for the development of child-specific protocols for IGRT imaging in pediatric patients.

60 APPLIED LIFE SCIENCES↗

The Dynamic Tumor Bed: Volumetric Changes in the Lumpectomy Cavity During Breast-Conserving Therapy

Purpose: To characterize the magnitude of volume change in the postoperative tumor bed before and during radiotherapy, and to identify any factors associated with large volumetric change. Methods and Materials: Thirty-six consecutive patients with early-stage or preinvasive breast cancer underwent breast-conserving therapy at our institution between June 2006 and October 2007. Computed tomography (CT) scans of the breast were obtained shortly after surgery, before the start of radiotherapy (RT) for treatment planning, and, if applicable, before the tumor bed boost. Postoperative changes, seroma, and surgical clips were used to define the tumor bed through consensus agreement of 3 observers (B.P., D.I., and J.L.). Multiple variables were examined for correlation with volumetric change. Results: Between the first and last scan obtained (median time, 7.2 weeks), the tumor bed volume decreased at least 20% in 86% of patients (n = 31) and at least 50% in 64% of patients (n = 23). From the postoperative scan to the planning scan (median time, 3 weeks), the tumor bed volume decreased by an average of 49.9%, or approximately 2.1% per postoperative day. From planning scan to boost scan (median interval, 7 weeks), the median tumor bed volume decreased by 44.6%, at an average rate of 0.95% per postoperative day. No single factor was significantly associated with a change in tumor bed volume greater than 20%. Conclusions: The average postlumpectomy cavity undergoes dramatic volumetric change after surgery and continues this change during RT. The rate of change is inversely proportional to the duration from surgery. In this study no factors studied predicted large volumetric change.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Outcomes From Three Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

Purpose: To report early outcomes with image-guided proton therapy for prostate cancer. Methods and Materials: We accrued 211 prostate cancer patients on prospective Institutional Review Board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, dose escalation from 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel followed by androgen deprivation for high-risk disease. Minimum follow-up was 2 years. Results: One intermediate-risk patient and 2 high-risk patients had disease progression. Pretreatment genitourinary (GU) symptom management was required in 38% of patients. A cumulative 88 (42%) patients required posttreatment GU symptom management. Four transient Grade 3 GU toxicities occurred, all among patients requiring pretreatment GU symptom management. Multivariate analysis showed correlation between posttreatment GU 2+ symptoms and pretreatment GU symptom management (p < 0.0001) and age (p = 0.0048). Only 1 Grade 3+ gastrointestinal (GI) symptom occurred. The prevalence of Grade 2+ GI symptoms was 0 (0%), 10 (5%), 12 (6%), and 8 (4%) at 6, 12, 18, and 24 months, with a cumulative incidence of 20 (10%) patients at 2 years after proton therapy. Univariate and multivariate analyses showed significant correlation between Grade 2+ rectal bleeding and proctitis and the percentage of rectal wall (rectum) receiving doses ranging from 40 CGE (10 CGE) to 80 CGE. Conclusions: Early outcomes with image-guided proton therapy suggest high efficacy and minimal toxicity with only 1.9% Grade 3 GU symptoms and <0.5% Grade 3 GI toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase 2 Trial of Concurrent Chemotherapy and Proton Therapy for Stage III Non-Small Cell Lung Cancer: Results and Reflections Following Early Closure of a Single-Institution Study

Purpose: Proton therapy has been shown to reduce radiation dose to organs at risk (OAR) and could be used to safely escalate the radiation dose. We analyzed outcomes in a group of phase 2 study patients treated with dose-escalated proton therapy with concurrent chemotherapy for stage 3 non-small cell lung cancer (NSCLC). Methods and Materials: From 2009 through 2013, LU02, a phase 2 trial of proton therapy delivering 74 to 80 Gy at 2 Gy/fraction with concurrent chemotherapy for stage 3 NSCLC, was opened to accrual at our institution. Due to slow accrual and competing trials, the study was closed after just 14 patients (stage IIIA, 9 patients; stage IIIB, 5 patients) were accrued over 4 years. During that same time period, 55 additional stage III patients were treated with high-dose proton therapy, including 7 in multi-institutional proton clinical trials, 4 not enrolled due to physician preference, and 44 who were ineligible based on strict entry criteria. An unknown number of patients were ineligible for enrollment due to insurance coverage issues and thus were treated with photon radiation. Median follow-up of surviving patients was 52 months. Results: Two-year overall survival and progression-free survival rates were 57% and 25%, respectively. Median lengths of overall survival and progression-free survival were 33 months and 14 months, respectively. There were no acute grade 3 toxicities related to proton therapy. Late grade 3 gastrointestinal toxicity and pulmonary toxicity each occurred in 1 patient. Conclusions: Dose-escalated proton therapy with concurrent chemotherapy was well tolerated with encouraging results among a small cohort of patients. Unfortunately, single-institution proton studies may be difficult to accrue and consideration for pragmatic and/or multicenter trial design should be considered when developing future proton clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasonic Characterization of Cast Austenitic Stainless Steel Microstructure: Discrimination between Equiaxed- and Columnar-Grain Material – An Interim Study

Ultrasonic nondestructive evaluation (NDE) and inspection of cast austenitic stainless steel (CASS) components used in the nuclear power industry is neither as effective nor reliable as is needed due to detrimental effects upon the interrogating ultrasonic beam and interference from ultrasonic backscatter. The root cause is the coarse-grain microstructure inherent to this class of materials. Some ultrasonic techniques perform better for particular microstructural classifications and this has led to the hypothesis that an ultrasonic inspection can be optimized for a particular microstructural class, if a technique exists to reliably classify the microstructure for feedback to the inspection. This document summarizes scoping experiments of in-situ ultrasonic methods for classification and/or characterization of the material microstructures in CASS components from the outside surface of a pipe. The focus of this study was to evaluate ultrasonic methods and provide an interim report that documents results and technical progress. An initial set of experiments were performed to test the hypothesis that in-service characterization of cast austenitic stainless steel (CASS) is feasible, and that, if reliably performed, such data would provide real-time feedback to optimize in-service inspections in the field. With this objective in mind, measurements for the experiment were restricted to techniques that should be robust if carried forward to eventual field implementation. Two parameters were investigated for their ability to discriminate between different microstructures in CASS components. The first parameter was a time-of-flight ratio of a normal incidence shear wave to that of a normal incidence longitudinal wave (TOFRSL). The ratio removed dependency on component thickness which may not be accurately reported in the field. The second parameter was longitudinal wave attenuation. The selected CASS specimens provided five equiaxed-grain material samples and five columnar-grain material samples for a two-class discrimination problem. Qualitative TOFRSL estimates and a threshold algorithm classified all 10 material samples correctly and indicated a reliable and robust technique. Qualitative longitudinal wave attenuation estimates and a threshold algorithm also classified all 10 materials samples correctly; however, the technique was not as robust as TOFRSL. The experiments provided promising results and demonstrated that good potential exists for future development of techniques to implement real-time classification of CASS material. However, the reported measurements need to be substantiated with measurements on additional specimens.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MO-DE-207A-12: Toward Patient-Specific 4DCT Reconstruction Using Adaptive Velocity Binning

Purpose: While 4DCT provides organ/tumor motion information, it often samples data over 10–20 breathing cycles. For patients presenting with compromised pulmonary function, breathing patterns can change over the acquisition time, potentially leading to tumor delineation discrepancies. This work introduces a novel adaptive velocity-modulated binning (AVB) 4DCT algorithm that modulates the reconstruction based on the respiratory waveform, yielding a patient-specific 4DCT solution. Methods: AVB was implemented in a research reconstruction configuration. After filtering the respiratory waveform, the algorithm examines neighboring data to a phase reconstruction point and the temporal gate is widened until the difference between the reconstruction point and waveform exceeds a threshold value—defined as percent difference between maximum/minimum waveform amplitude. The algorithm only impacts reconstruction if the gate width exceeds a set minimum temporal width required for accurate reconstruction. A sensitivity experiment of threshold values (0.5, 1, 5, 10, and 12%) was conducted to examine the interplay between threshold, signal to noise ratio (SNR), and image sharpness for phantom and several patient 4DCT cases using ten-phase reconstructions. Individual phase reconstructions were examined. Subtraction images and regions of interest were compared to quantify changes in SNR. Results: AVB increased signal in reconstructed 4DCT slices for respiratory waveforms that met the prescribed criteria. For the end-exhale phases, where the respiratory velocity is low, patient data revealed a threshold of 0.5% demonstrated increased SNR in the AVB reconstructions. For intermediate breathing phases, threshold values were required to be >10% to notice appreciable changes in CT intensity with AVB. AVB reconstructions exhibited appreciably higher SNR and reduced noise in regions of interest that were photon deprived such as the liver. Conclusion: We demonstrated that patient-specific velocity-based 4DCT reconstruction is feasible. Image noise was reduced with AVB, suggesting potential applications for low-dose acquisitions and to improve 4DCT reconstruction for irregular breathing patients. The submitting institution holds research agreements with Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Panels of HIV-1 Subtype C Env Reference Strains for Standardized Neutralization Assessments

In the search for effective immunologic interventions to prevent and treat HIV-1 infection, standardized reference reagents are a cost-effective way to maintain robustness and reproducibility among immunological assays. To support planned and ongoing studies where clade C predominates, here we describe three virus panels, chosen from 200 well-characterized clade C envelope (Env)-pseudotyped viruses from early infection. All 200 Envs were expressed as a single round of replication pseudoviruses and were tested to quantify neutralization titers by 16 broadly neutralizing antibodies (bnAbs) and sera from 30 subjects with chronic clade C infections. We selected large panels of 50 and 100 Envs either to characterize cross-reactive breadth for sera identified as having potent neutralization activity based on initial screening or to evaluate neutralization magnitude-breadth distributions of newly isolated antibodies. We identified these panels by downselection after hierarchical clustering of bnAb neutralization titers. The resulting panels represent the diversity of neutralization profiles throughout the range of virus sensitivities identified in the original panel of 200 viruses. A small 12-Env panel was chosen to screen sera from vaccine trials or natural-infection studies for neutralization responses. We considered panels selected by previously described methods but favored a computationally informed method that enabled selection of viruses representing diverse neutralization sensitivity patterns, given that we do not a priori know what the neutralization-response profile of vaccine sera will be relative to that of sera from infected individuals. The resulting 12-Env panel complements existing panels. Use of standardized panels enables direct comparisons of data from different trials and study sites testing HIV-1 clade C-specific products. HIV-1 group M includes nine clades and many recombinants. Clade C is the most common lineage, responsible for roughly half of current HIV-1 infections, and is a focus for vaccine design and testing. Standard reference reagents, particularly virus panels to study neutralization by antibodies, are crucial for developing cost-effective and yet rigorous and reproducible assays against diverse examples of this variable virus. We developed clade C-specific panels for use as standardized reagents to monitor complex polyclonal sera for neutralization activity and to characterize the potency and breadth of cross-reactive neutralization by monoclonal antibodies, whether engineered or isolated from infected individuals. We chose from 200 southern African, clade C envelope-pseudotyped viruses with neutralization titers against 16 broadly neutralizing antibodies and 30 sera from chronic clade C infections. We selected panels to represent the diversity of bnAb neutralization profiles and Env neutralization sensitivities. Finally, use of standard virus panels can facilitate comparison of results across studies and sites.

59 BASIC BIOLOGICAL SCIENCES↗

Chest Wall Ewing Sarcoma Family of Tumors: Long-Term Outcomes

Purpose: To review the 40-year University of Florida experience treating Ewing sarcoma family of tumors of the chest wall. Methods and Materials: Thirty-nine patients were treated from 1966 to 2006. Of the patients, 22 were treated with radiotherapy (RT) alone, and 17 patients were treated with surgery with or without RT. Of 9 patients with metastatic disease, 8 were treated with RT alone. The risk profiles of each group were otherwise similar. The median age was 16.6 years, and the most frequent primary site was the rib (n = 17). The median potential follow-up was 19.2 years. Results: The 5-year actuarial overall survival (OS), cause-specific survival (CSS), and local control (LC) rates were 34%, 34%, and 72%, respectively. For the nonmetastatic subset (n = 30), the 5-year OS, CSS, and LC rates were 44%, 44%, and 79%, respectively. LC was not statistically significantly different between patients treated with RT alone (61%) vs. surgery + RT (75%). None of the 4 patients treated with surgery alone experienced local failure. No patient or treatment variable was significantly associated with local failure. Of the patients, 26% experienced Common Toxicity Criteria (CTC) Grade 3+ toxicity, including 2 pulmonary deaths. Modern intensive systemic therapy helped increase the 5-year CSS from 7% to 49% in patients treated after 1984 (p = 0.03). Conclusions: This is the largest single-institution series describing the treatment of chest wall Ewing tumors. Despite improvements in survival, obtaining local control is challenging and often accompanied by morbidity. Effort should be focused on identifying tumors amenable to combined-modality local therapy and to improving RT techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Five-Year Outcomes from 3 Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

Purpose: To report 5-year clinical outcomes of 3 prospective trials of image-guided proton therapy for prostate cancer. Methods and Materials: A total of 211 prostate cancer patients (89 low-risk, 82 intermediate-risk, and 40 high-risk) were treated in institutional review board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel therapy followed by androgen deprivation therapy for high-risk disease. Toxicities were graded according to Common Terminology Criteria for Adverse Events (CTCAE), version 3.0. Median follow-up was 5.2 years. Results: Five-year rates of biochemical and clinical freedom from disease progression were 99%, 99%, and 76% in low-, intermediate-, and high-risk patients, respectively. Actuarial 5-year rates of late CTCAE, version 3.0 (or version 4.0) grade 3 gastrointestinal and urologic toxicity were 1.0% (0.5%) and 5.4% (1.0%), respectively. Median pretreatment scores and International Prostate Symptom Scores at >4 years posttreatment were 8 and 7, 6 and 6, and 9 and 8, respectively, among the low-, intermediate-, and high-risk patients. There were no significant changes between median pretreatment summary scores and Expanded Prostate Cancer Index Composite scores at >4 years for bowel, urinary irritative and/or obstructive, and urinary continence. Conclusions: Five-year clinical outcomes with image-guided proton therapy included extremely high efficacy, minimal physician-assessed toxicity, and excellent patient-reported outcomes. Further follow-up and a larger patient experience are necessary to confirm these favorable outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of body repositioning after venous air embolism. An echocardiographic study

BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

NASA Discipline Environmental Health↗