Search NASA⌕ Search

SEARCH · Search NASA

Results for “Muon System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Progress on muon parametric-resonance ionization cooling channel development

Parametric-resonance Ionization Cooling (PIC) is intended as the final 6D cooling stage of a high-luminosity muon collider. To implement PIC, a continuous-field twin-helix magnetic channel was developed. A 6D cooling with stochastic effects off is demonstrated in a GEANT4/G4beamline model of a system where wedge-shaped Be absorbers are placed at the appropriate dispersion points in the twin-helix channel and are followed by short rf cavities. To proceed to cooling simulations with stochastics on, compensation of the beam aberrations from one absorber to another is required. Initial results on aberration compensation using a set of various-order continuous multipole fields are presented. As another avenue to mitigate the aberration effect, we optimize the cooling channel's period length. We observe a parasitic parametric resonance naturally occurring in the channel's horizontal plane due to the periodic beam energy modulation caused by the absorbers and rf. We discuss options for compensating this resonance and/or properly combining it with the induced half-integer parametric resonance needed for PIC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing CPT conservation using the NuMI neutrino beam with the MINOS experiment

The MINOS experiment was designed to measure neutrino oscillation parameters with muon neutrinos. It achieves this by measuring the neutrino energy spectrum and flavor composition of the man-made NuMI neutrino beam 1km after the beam is formed and again after 735 km. By comparing the two spectra it is possible to measure the oscillation parameters. The NuMI beam is made up of 7.0%$\bar{v}$ μ , which can be separated from the v μ because the MINOS detectors are magnetized. This makes it possible to study $\bar{v}$ μ oscillations separately from those of muon neutrinos, and thereby test CPT invariance in the neutrino sector by determining the $\bar{v}$ μ oscillation parameters and comparing them with those for v μ , although any unknown physics of the antineutrino would appear as a difference in oscillation parameters. Such a test has not been performed with beam $\bar{v}$ μ before. It is also possible to produce an almost pure $\bar{v}$ μ beam by reversing the current through the magnetic focusing horns of the NuMI beamline, thereby focusing negatively, instead of positively charged particles. This thesis describes the analysis of the 7% $\bar{v}$ μ component of the forward horn current NuMI beam. The $\bar{v}$ μ of a data sample of 3.2 x 10{sup 20} protons on target analysis found 42 events, compared to a CPT conserving prediction of 58.3 -7.6 +7.6 (stat.) -3.6 +3.6 (syst.) events. This corresponds to a 1.9 σ deficit, and a best fit value of Δ$\bar{m}$ 32 2 = 18 x 10 -3 eV 2 and sin 2 2$\bar{θ}$ 23 = 0.55. This thesis focuses particularly on the selection of $\bar{v}$ μ events, and investigates possible improvements of the selection algorithm. From this a different selector was chosen, which corroborated the findings of the original selector. The thesis also investigates how the systematic errors affect the precision of Δ$\bar{m}$ 32 2 and sin 2 2$\bar{θ}$ 23 . Furthermore, it describes a study to determine the gains of the PMTs via the single-photoelectron spectrum. The results were used as a crosscheck of the gains determined at higher intensities by an LED-based light-injection system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Epicyclic Twin-Helix Ionization Cooling Simulations

Parametric-resonance Ionization Cooling (PIC) is proposed as the final 6D cooling stage of a highluminosity muon collider. For the implementation of PIC, we earlier developed an epicyclic twin-helix channel with correlated behavior of the horizontal and vertical betatron motions and dispersion. We now insert absorber plates with short energy-recovering units located next to them at the appropriate locations in the twin-helix channel. We first demonstrate conventional ionization cooling in such a system with the optics uncorrelated. We then adjust the correlated optics state and induce a parametric resonance to study ionization cooling under the resonant condition.

43 PARTICLE ACCELERATORS↗

Muon Borehole Detector Design for Use in 4-D Density Overburden Monitoring

The increase of atmospheric CO2 concentrations has initiated research into carbon sequestration methods. One possibility is to store CO2 in subsurface porous reservoirs. The monitoring of the injected CO2 plume is vital because escaping CO2 poses health and environmental risks. Typically, seismic reflection methods are used to determine the change in density due to the replacement of brine by CO2 in the reservoir, but this is expensive and not continuous. A potential alternative is to use cosmic muon tomography to measure density changes in the reservoir as a function of time. This paper describes the development of a muon detector that will be capable of being deployed in boreholes. The detector has the required dimensions, an angular resolution of approximately 2 degrees, and is robust. The design is based on alternating layers of scintillating rods, which can provide 4-D tomographic data to detect small changes in density at depths up to approximately 2 km. Geant4, a Monte Carlo simulation code, is being used to develop models to guide the design of the physical configuration. Preliminary testing and measurements have been performed to validate the simulation predictions and optimize the performance of the system. The simulation and preliminary experimental results are presented here.

Borehole Detector, CO¬2 Sequestration, Geant4, Muo↗

The SeaQuest spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell–Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

36 MATERIALS SCIENCE↗

Light-front spin-dependent spectral function and nucleon momentum distributions for a three-body system

Poincare covariant definitions for the spin-dependent spectral function and for the momentum distributions within the light-front Hamiltonian dynamics are proposed for a three-fermion bound system, starting from the light-front wave function of the system. The adopted approach is based on the Bakamjian–Thomas construction of the Poincaré generators, which allows one to easily import the familiar and wide knowledge on the nuclear interaction into a light-front framework. The proposed formalism can find useful applications in refined nuclear calculations, such as those needed for evaluating the European Muon Collaboration effect or the semi-inclusive deep inelastic cross sections with polarized nuclear targets, since remarkably the light-front unpolarized momentum distribution by definition fulfills both normalization and momentum sum rules. As a result, also shown is a straightforward generalization of the definition of the light-front spectral function to an A -nucleon system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast inference of Boosted Decision Trees in FPGAs for particle physics

We describe the implementation of Boosted Decision Trees in the hls4ml library, which allows the translation of a trained model into FPGA firmware through an automated conversion process. Thanks to its fully on-chip implementation, hls4ml performs inference of Boosted Decision Tree models with extremely low latency. With a typical latency less than 100 ns, this solution is suitable for FPGA-based real-time processing, such as in the Level-1 Trigger system of a collider experiment. These developments open up prospects for physicists to deploy BDTs in FPGAs for identifying the origin of jets, better reconstructing the energies of muons, and enabling better selection of rare signal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higgs boson exchange effects in l{sup +}l{sup -}{yields}W{sup +}W{sup -} at high energy

We consider the prospects for detecting effects due to the Higgs exchange diagram in high energy {mu}{sup +}{mu}{sup -}, e{sup +}e{sup -}, and {tau}{sup +}{tau}{sup -} collisions producing a pair of W bosons. The processes l{sup +}l{sup -}{yields}W{sup +}W{sup -} (with l={mu}, e, {tau}) are analyzed, analytically and via numerical simulations, to determine the center of mass energy, {radical}(s{sub H}), where the effects from Higgs exchange become relevant. The scaling of {radical}(s{sub H}) with the mass of the incoming leptons is also studied. Special consideration is given to the W{sup +}W{sup -}{yields}l{sup {+-}}{nu}{sub l}jj final state after experimental acceptance cuts are imposed. Angular cuts are shown to be able to significantly lower {radical}(s{sub H}). The center of mass energy for which Higgs exchange effects become relevant in l{sup +}l{sup -}{yields}W{sup +}W{sup -} is found to be much higher than that in l{sup +}l{sup -}{yields}{nu}{nu}W{sup +}W{sup -}. Higgs boson exchange effects in W-pair production thus will not be relevant for the e{sup +}e{sup -} and {mu}{sup +}{mu}{sup -} colliders currently on the drawing board.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of the LBNF Beamline Target Station

The Long Baseline Neutrino Facility (LBNF) project will build a beamline located at Fermilab to create and aim an intense neutrino beam of appropriate energy range toward the DUNE detectors at the SURF facility in Lead, South Dakota. Neutrino production starts in the Target Station, which consists of a solid target, magnetic focusing horns, and the associated sub-systems and shielding infrastructure. Protons hit the target producing mesons which are then focused by the horns into a helium-filled decay pipe where they decay into muons and neutrinos. The target and horns are encased in actively cooled steel and concrete shielding in a chamber called the target chase. The reference design chase is filled with air, but nitrogen and helium are being evaluated as alternatives. A replaceable beam window separates the decay pipe from the target chase. The facility is designed for initial operation at 1.2 MW, with the ability to upgrade to 2.4 MW, and is taking advantage of the experience gained by operating Fermilab’s NuMI facility. We discuss here the design status, associated challenges, and ongoing R&D and physics-driven component optimization of the Target Station.

Tariq, S.↗

Reduction of the beam dynamics systematic uncertainties by the phase space matching with RF electric fields in Muon g –2 experiment at Fermilab

Muon g –2 experiment at Fermilab aims to measure the magnetic anomaly of the muon in a precision of 140 parts-per-billion (ppb). It is one of the most strongly motivated precision particle physics experiments to unveil the mystery of the long-standing 3σ-4σ tension between the previous measurement of the muon g –2 experiment at BNL and the Standard Model predictions. One of the main challenges of the experiment is to keep the total systematic uncertainty within 100 ppb budget. In this dissertation, a novel way of matching the phase space in the muon g –2 storage ring to reduce the beam dynamics systematic effects with RF electric fields is presented. Systematic simulation studies and hardware development of the RF matching system are covered, followed by the promising analysis results of the commissioning runs.

Kim, On↗

A liquid hydrogen target for the MUSE experiment at PSI

A 280 ml liquid hydrogen target has been constructed and tested here for the MUSE experiment at PSI to investigate the proton charge radius via simultaneous measurement of elastic muon–proton and elastic electron–proton scattering. To control systematic uncertainties at a sub-percent level, strong constraints were put on the amount of material surrounding the target and on its temperature stability. The target system was successfully operated during a commissioning run at PSI at the end of 2018. The target temperature was stable at the 0.01 K level. This indicates a density stability at the 0.02% level, which is about a factor of ten better than required.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for an excited lepton that decays via a contact interaction to a lepton and two jets in proton-proton collisions at $\sqrt{s} =$ 13 TeV

Results are presented from a search for events containing an excited lepton (electron or muon) produced in association with an ordinary lepton of the same flavor and decaying to a lepton and two hadronic jets. Both the production and the decay of the excited leptons are assumed to occur via a contact interaction with a characteristic energy scale Λ. The branching fraction for the decay mode under study increases with the mass of the excited lepton and is the most sensitive channel for very heavy excited leptons. The analysis uses a sample of proton-proton collisions collected by the CMS experiment at the LHC at $ \sqrt{s} $ = 13 TeV, corresponding to an integrated luminosity of 77.4 fb$^{−1}$. The four-body invariant mass of the two lepton plus two jet system is used as the primary discriminating variable. No significant excess of events beyond the expectation for standard model processes is observed. Assuming that Λ is equal to the mass of the excited leptons, excited electrons and muons with masses below 5.6 and 5.7 TeV, respectively, are excluded at 95% confidence level. These are the best limits to date.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic design constraints of helical solenoids

Helical solenoids have been proposed as an option for a Helical Cooling Channel for muons in a proposed Muon Collider. Helical solenoids can provide the required three main field components: solenoidal, helical dipole, and a helical gradient. In general terms, the last two are a function of many geometric parameters: coil aperture, coil radial and longitudinal dimensions, helix period and orbit radius. In this paper, we present design studies of a Helical Solenoid, addressing the geometric tunability limits and auxiliary correction system.

43 PARTICLE ACCELERATORS↗

The SeaQuest Spectrometer at Fermilab

The SeaQuest spectrometer at Fermilab was designed to detect oppositely-charged pairs of muons (dimuons) produced by interactions between a 120 GeV proton beam and liquid hydrogen, liquid deuterium and solid nuclear targets. The primary physics program uses the Drell-Yan process to probe antiquark distributions in the target nucleon. The spectrometer consists of a target system, two dipole magnets and four detector stations. The upstream magnet is a closed-aperture solid iron magnet which also serves as the beam dump, while the second magnet is an open aperture magnet. Each of the detector stations consists of scintillator hodoscopes and a high-resolution tracking device. The FPGA-based trigger compares the hodoscope signals to a set of pre-programmed roads to determine if the event contains oppositely-signed, high-mass muon pairs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fun- damental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr- based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared

Gallego-Ros, Ana↗

Muon spin rotation measurements of heterogeneous field response in overdoped La2-xSrxCuO4

Transverse-field muon spin rotation measurements of overdoped La{sub 2-x}Sr{sub x}CuO{sub 4} reveal a large broadening of the local magnetic field distribution in response to applied field, persisting to high temperatures. The field response is approximately Curie-Weiss-like in temperature and is largest for the highest doping investigated. Such behavior is contrary to the canonical Fermi-liquid picture commonly associated with the overdoped cuprates and implies extensive heterogeneity in this region of the phase diagram. A possible explanation for the result lies in regions of staggered magnetization about dopant cations, analogous to what is argued to exist in underdoped systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Studies on the scintillation light detection in the ProtoDUNE Dual Phase liquid-argon TPC and its capability for the supernova trigger in DUNE

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino oscillation experiment that aims at addressing key questions in neutrino physics in the next decades. Its scientific program includes the detection of the neutrino flux from a core-collapse supernova. The DUNE far detector will have four 17-kt mass liquid-argon (LAr) time-projection chamber (TPC) modules. ProtoDUNE Dual Phase (DP), a dual-phase LAr TPC with 300 t of active mass and 6 m of drift distance, was operated with cosmic muons in 2019-2020 as part of an R&D program at the CERN Neutrino Platform to demonstrate the feasibility of the technology at such a large scale. In a LAr TPC, the photon detection system (PDS) provides fundamental timing information and trigger capabilities. The PDS of ProtoDUNE-DP, which consisted of 36 photomultiplier tubes (PMTs), counted on a dedicated light calibration system (LCS) to monitor the PMT response. In this dissertation, the characterization and validation of the ProtoDUNE-DP PDS and LCS components before their installation will be reviewed, highlighting the results of general interest for experiments that use liquid noble gasses as target medium. The results from the stable performance of both systems in the detector during 15 months will be presented next as well as the studies on the scintillation light detection in ProtoDUNE-DP, where the collection of light produced in LAr at 7 m from the photosensors has been achieved for the first time. It is worth pointing out that the excellent LAr purity and the large size of the detector have enabled to develop a unique data-driven investigation on aspects that are critical for LAr-based experiments but that are not completely understood. The analyses cover the characterization of the low-energy background detected by the PDS, the quantification of the electric field impact on the light yield, the evaluation of the Rayleigh scattering affecting the light propagation, and the analysis of the PMT detection efficiency. The effect of the VUV reflectivity of the detector materials will be also discussed. In addition, the estimation of the cosmic muon flux crossing the TPC and the study of the observed light yield by the PDS will be reported. Finally, the results from the simulation-based study of the supernova burst trigger capability with the PDS of a 12.1-kt active mass dual-phase LAr TPC as the one proposed for DUNE will be summarized. Several configurations of reflective foils installed in the TPC to enhance the light collection will be compared.

Gallego Ros, Ana↗