Search NASA⌕ Search

SEARCH · Search NASA

Results for “Net load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Value of Energy Storage for Grid Applications

This analysis evaluates several operational benefits of electricity storage, including load-leveling, spinning contingency reserves, and regulation reserves. Storage devices were simulated in a utility system in the western United States, and the operational costs of generation was compared to the same system without the added storage. This operational value of storage was estimated for devices of various sizes, providing different services, and with several sensitivities to fuel price and other factors. Overall, the results followed previous analyses that demonstrate relatively low value for load-leveling but greater value for provision of reserve services. The value was estimated by taking the difference in operational costs between cases with and without energy storage and represents the operational cost savings from deploying storage by a traditional vertically integrated utility. The analysis also estimated the potential revenues derived from a merchant storage plant in a restructured market, based on marginal system prices. Due to suppression of on-/off-peak price differentials and incomplete capture of system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit provided to the system. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value of Energy Storage for Grid Applications (Report Summary) (Presentation)

This analysis evaluates several operational benefits of electricity storage, including load-leveling, spinning contingency reserves, and regulation reserves. Storage devices were simulated in a utility system in the western United States, and the operational costs of generation was compared to the same system without the added storage. This operational value of storage was estimated for devices of various sizes, providing different services, and with several sensitivities to fuel price and other factors. Overall, the results followed previous analyses that demonstrate relatively low value for load-leveling but greater value for provision of reserve services. The value was estimated by taking the difference in operational costs between cases with and without energy storage and represents the operational cost savings from deploying storage by a traditional vertically integrated utility. The analysis also estimated the potential revenues derived from a merchant storage plant in a restructured market, based on marginal system prices. Due to suppression of on-/off-peak price differentials and incomplete capture of system benefits (such as the cost of power plant starts), the revenue obtained by storage in a market setting appears to be substantially less than the net benefit provided to the system. This demonstrates some of the additional challenges for storage deployed in restructured energy markets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transforming Agricultural Systems on Public Lands in the EAA to Support Everglades Restoration

The survival of Florida’s biodiversity and economy is dependent on finding ways to balance farm economics with proper management of water and other natural resources. The state purchase of U.S. Sugar lands in critical areas of south Florida, replacing them with water storage and treatment areas, creates both an opportunity and imperative for new farming systems. These transformed farming system could provide a viable economic and ecological alternative to the reservoirs, STA’s, and flow-way. An agricultural model built around flood-tolerant sugarcane varieties could be compatible with the new visions for EAA lands. Reducing the agricultural intensity of these farms creates the risk or reality of yield reduction and lower farm income, but would allow for water storage, reduced nutrient loads, and muck soil carbon conservation on the farms. Payments for these ecosystem services could offset the loss in crop revenues. Cultivation of flood-tolerant sugarcane allows for temporary storage of water on a field followed by water transfer to an adjacent field. Using this relay approach, a water pulse could be passed down a corridor of fields. The volume of water transported to the south via a pulse way depends largely on the nutrient dynamics of the soil-water system. If the nutrient flux becomes the limiting factor then water volumes sent into the corridors would be limited to the net increase in soil-water storage and ET losses. Including ecosystem services as revenue streams in agricultural business models to compensate for lower yield income requires: (1) quantifying the services delivered, (2) assigning values to the services, and (3) compensating farmers for the quantities delivered. The direct ecosystem services provided by a flood-tolerant sugarcane farming system are (1) water storage, (2) nutrient removal and (3) carbon sequestration. A farming system that significantly reduces soil subsidence and its resulting carbon loss to the atmosphere may be eligible for credit sales on already-existing carbon markets. Farmers and local governments traditionally have been hesitant to consider radically new approaches to agriculture. But facing a significant loss of farms, jobs and tax base creates a receptiveness to change.

54 ENVIRONMENTAL SCIENCES↗

Comparative study of the cooling energy performance of variable refrigerant flow systems and variable air volume systems in office buildings

Variable air volume (VAV) and variable refrigerant flow (VRF) systems are widely used in office buildings. This study investigated VAV and VRF systems in five typical office buildings in China, and compared their cooling energy use. Site survey and field measurements were conducted to collect the data of building characteristics and operation. Measured cooling electricity use was collected from sub-metering in the five buildings. The sub-metering data normalized by climate and operating hours indicated that the cooling energy consumed by VRF systems was up to 70% lower than that consumed by VAV systems. This was mainly because of the different operation modes of both system types that led to significantly fewer operating hours for the VRF systems. Building simulations were used to quantify the impact of operation modes of VRF and VAV systems on cooling loads. A prototype office building in China was used as the model. The simulation results showed that the VRF operation mode required much lower cooling load when compared to the VAV operation mode. For example, the cooling loads decreased by 42% in Hong Kong and 53% in Qingdao. Key findings include the following: the VRF systems operated in the part-time-part-space mode enabling occupants to turn on the air-conditioning only when needed and when the spaces were occupied. However, the VAV systems operated in the full-time-full-space mode limiting occupants’ control of operation. These findings provide insights into VRF systems operation and controls as well as their energy performance, which could help guide HVAC designers on system selection and building operators or facility managers on system operations to achieve low- or zero-net energy buildings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

RDI's Wisdom Way Solar Village Final Report: Includes Utility Bill Analysis of Occupied Homes

In 2010, Rural Development, Inc. (RDI) completed construction of Wisdom Way Solar Village (WWSV), a community of ten duplexes (20 homes) in Greenfield, MA. RDI was committed to very low energy use from the beginning of the design process throughout construction. Key features include: 1. Careful site plan so that all homes have solar access (for active and passive); 2. Cellulose insulation providing R-40 walls, R-50 ceiling, and R-40 floors; 3. Triple-pane windows; 4. Airtight construction (~0.1 CFM 50 /ft 2 enclosure area); 5. Solar water heating systems with tankless, gas, auxiliary heaters; 6. PV systems (2.8 or 3.4kW STC ); 7. 2-4 bedrooms, 1,100-1,700 ft 2 . The design heating loads in the homes were so small that each home is heated with a single, sealed-combustion, natural gas room heater. The cost savings from the simple HVAC systems made possible the tremendous investments in the homes' envelopes. The Consortium for Advanced Residential Buildings (CARB) monitored temperatures and comfort in several homes during the winter of 2009-2010. In the Spring of 2011, CARB obtained utility bill information from 13 occupied homes. Because of efficient lights, appliances, and conscientious home occupants, the energy generated by the solar electric systems exceeded the electric energy used in most homes. Most homes, in fact, had a net credit from the electric utility over the course of a year. On the natural gas side, total gas costs averaged $|$$377 per year (for heating, water heating, cooking, and clothes drying). Total energy costs were even less - $\$$337 per year, including all utility fees. The highest annual energy bill for any home evaluated was $\$$458; the lowest was $\$$171.

14 SOLAR ENERGY↗

Leveraging Energy Storage in a Solar-Tower and Combined Cycle Hybrid Power Plant

A method is presented to enhance solar penetration of a hybrid solar-combined cycle power plant integrated with a packed-bed thermal energy storage system. The hybrid plant is modeled using Simulink and employs systems-level automation. Feedback control regulates net power, collector temperature, and turbine firing temperature. A base-case plant is presented, and plant design is systematically modified to improve solar energy utilization. A novel recycling configuration enables robust control of collector temperature and net power during times of high solar activity. Recycling allows for improved solar energy utilization and a yearly solar fraction over 30%, while maintaining power control. During significant solar activity, excessive collector temperature and power setpoint mismatch are still observed with the proposed recycling configuration. A storage bypass is integrated with recycling, to lower storage charging rate. This operation results in diverting only a fraction of air flow to storage, which lowers the storage charging rate and improves solar energy utilization. Recycling with a storage bypass can handle larger solar inputs and a solar fraction over 70% occurs when following a drastic peaking power load. The novel plant configuration is estimated to reduce levelized cost of the plant by over 4% compared to the base-case plant.

14 SOLAR ENERGY↗

Solid-State NMR Investigations of the Immobilization of a BF4 Salt of a Palladium(II) Complex on Silica

The structure of the silica supported palladium(II) complex [Pd(dppp)(S{sub 2}C-NEt{sub 2})]BF{sub 4} (abbreviated as [Pd(dppp)(dtc)]BF{sub 4}, where dppp is Ph{sub 2}P(CH{sub 2}){sub 3}PPh{sub 2}) and interactions between the [Pd(dppp)(dtc)]{sup +} cation, the BF{sub 4}{sup -} anion, and the silica surface are studied using solid-state NMR spectroscopy. The unsupported, crystalline form of [Pd(dppp)(dtc)]BF{sub 4} is also investigated, both by X-ray diffraction and NMR. The structures of the cation and anion are found to be essentially the same in both unsupported and supported complex. The [Pd(dppp)(dtc)]BF{sub 4} loading has been determined by quantitative measurements of {sup 11}B, {sup 19}F, and {sup 31}P intensities, whereas the arrangement of anions and cations on the surface of silica has been established by two-dimensional heteronuclear correlation experiments involving {sup 1}H, {sup 11}B, {sup 13}C, {sup 19}F, {sup 29}Si, and {sup 31}P nuclei. At low coverages, the [Pd(dppp)(dtc)]{sup +} cations are located near the BF{sub 4}{sup -} anions, which in turn are immobilized directly on the surface near the Q{sup 4} sites. At higher loadings, which in this study corresponded to 0.06-0.15 mmol/g, the complexes stack on top of each other, despite the fact that the directly adsorbed molecules take up less than 10% of the silica surface. The relevance of these findings to heterogeneous catalysis is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scheduler Modeling of Distributed Energy Resources for Providing Ancillary Services

Distribution energy resources (DERs) have been integral components of modern power systems, and their capability to provide grid services has been widely studied. To promote the deployment of these resources in providing grid services in real-world utility operations, this paper proposes a day-ahead scheduler model for a distribution system connected DER plant. A certain amount of generation capacity of this DER plant is reserved for frequency services, and some ancillary services for the distribution system-including peak load reduction, voltage regulation, and power factor control-are integrated into the model. The model is tested on a real-world distribution system. From the simulation results, the energy and reserve schedule of the solar photovoltaic (PV) unit and battery energy storage system (BESS) can be determined, and voltage and power factor are well maintained. Additionally, in order to demonstrate the specific characteristics of the co-located and hybrid operation modes for the PV and BESS, these two modes are analyzed both theoretically and through real-time simulation. Simulation results show that most of PV's variability is transferred to the net power in the co-located mode, whereas it is transferred to the BESS in the hybrid mode. This proposed scheduler model and the comparison of co-located and hybrid modes can provide practical guidance for the applications of DER plant in the real-world utility.

14 SOLAR ENERGY↗

Soil warming alters nitrogen cycling in a New England forest: implications for ecosystem function and structure

Global climate change is expected to affect terrestrial ecosystems in a variety of ways. Some of the more well-studied effects include the biogeochemical feedbacks to the climate system that can either increase or decrease the atmospheric load of greenhouse gases such as carbon dioxide and nitrous oxide. Less well-studied are the effects of climate change on the linkages between soil and plant processes. Here, we report the effects of soil warming on these linkages observed in a large field manipulation of a deciduous forest in southern New England, USA, where soil was continuously warmed 5C above ambient for 7 years. Over this period, we have observed significant changes to the nitrogen cycle that have the potential to affect tree species composition in the long term. Since the start of the experiment, we have documented a 45% average annual increase in net nitrogen mineralization and a three-fold increase in nitrification such that in years 5 through 7, 25% of the nitrogen mineralized is then nitrified. The warming-induced increase of available nitrogen resulted in increases in the foliar nitrogen content and the relative growth rate of trees in the warmed area. Acer rubrum (red maple) trees have responded the most after 7 years of warming, with the greatest increases in both foliar nitrogen content and relative growth rates. Our study suggests that considering species-specific responses to increases in nitrogen availability and changes in nitrogen form is important in predicting future forest composition and feedbacks to the climate system.

54 ENVIRONMENTAL SCIENCES↗

Discerning molecular-level CO 2 adsorption behavior in amine-modified sorbents within a controlled CO 2 /H 2 O environment towards direct air capture

Sorbents designed for direct air capture (DAC) play a crucial role in the pursuit of achieving net-zero carbon dioxide emissions. This study elucidates CO 2 adsorption from dilute, humidified CO 2 streams onto an amine-modified benchmark DAC adsorbent via solid-state NMR spectroscopy. Various NMR techniques, including 1D 1 H MAS, 13 C MAS, 2D 1 H– 13 C HETCOR NMR, and 1 H R 2 and R 1ρ relaxometry reveal the impact of CO 2 partial pressure and H 2 O on CO 2 adsorption behavior. Here we find that CO 2 concentration governs the stepwise formation of ammonium carbamate, carbamic acid, and physisorbed CO 2 , where relative humidity (RH) at a desired low (<400 ppm) CO 2 loading affects total CO 2 uptake. The relaxation studies reveal the cooperative or competitive nature of H 2 O–CO 2 sorption in CO 2 -dilute humid gas, and in particular polymer swelling upon humidification. From those results, we demonstrate that the observed absorption capacity enhancement by humidity is caused by pore opening due to sorbent swelling, and not by bicarbonate formation. This NMR-discerned speciation provides insights into sorption behavior at different RHs in dilute CO 2 gas streams, simulating real-world atmospheric conditions, and governs the design of efficient and adaptable material-process combinations for solid sorbent DAC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Puget Sound Dissolved Oxygen Modeling Study: Development of an Intermediate-Scale Hydrodynamic Model

The Washington State Department of Ecology contracted with Pacific Northwest National Laboratory to develop an intermediate-scale hydrodynamic and water quality model to study dissolved oxygen and nutrient dynamics in Puget Sound and to help define potential Puget Sound-wide nutrient management strategies and decisions. Specifically, the project is expected to help determine 1) if current and potential future nitrogen loadings from point and non-point sources are significantly impairing water quality at a large scale and 2) what level of nutrient reductions are necessary to reduce or dominate human impacts to dissolved oxygen levels in the sensitive areas. In this study, an intermediate-scale hydrodynamic model of Puget Sound was developed to simulate the hydrodynamics of Puget Sound and the Northwest Straits for the year 2006. The model was constructed using the unstructured Finite Volume Coastal Ocean Model. The overall model grid resolution within Puget Sound in its present configuration is about 880 m. The model was driven by tides, river inflows, and meteorological forcing (wind and net heat flux) and simulated tidal circulations, temperature, and salinity distributions in Puget Sound. The model was validated against observed data of water surface elevation, velocity, temperature, and salinity at various stations within the study domain. Model validation indicated that the model simulates tidal elevations and currents in Puget Sound well and reproduces the general patterns of the temperature and salinity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Prototypical District-Scale Models

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANopt platform workflows. A case study was performed to demonstrate the model application.

building energy modeling↗

Development of Prototypical District-Scale Models: Preprint

The U.S. has set the climate goal to achieve net-zero greenhouse gas emissions by 2050. District-scale solutions, which include scale-specific opportunities for energy and emissions savings, can be investigated and implemented to help accelerate decarbonization and progress toward this goal. However, there is currently a lack of district-scale models of buildings and community energy systems that can be used to evaluate potential district-scale technologies and strategies across a range of representative community types. This initial work aims to define and develop prototype district models that can be adapted to support the planning, design, and operation of buildings and energy systems in districts considering the complexity and interactions of diverse building loads, weather impacts, distributed energy resources (e.g., PV, EV, electric and thermal energy storage), electric and thermal grid systems, and pricing signals. An overall workflow for developing these prototype district models is established. Stakeholders and potential users of the prototype district models provided technical feedback. The specifications of the selected high priority districts were defined and documented in a scorecard format. An example prototype district model was implemented with the URBANoptTM platform workflows. A case study was performed to demonstrate the model application.

district↗

MA transmutation performance in the optimized MYRRHA

MYRRHA (multi-purpose hybrid research reactor for high-tech applications) is a multipurpose research facility currently being developed at SCK-CEN. It will be able to work in both critical and subcritical modes and, cooled by lead-bismuth eutectic. In this paper the minor actinides (MA) transmutation capabilities of MYRRHA are investigated. (Pu + Am, U) MOX fuel and (Np + Am + Cm, Pu) Inert Matrix Fuel test samples have been loaded in the central channel of the MYRRHA critical core and have been irradiated during five cycles, each one consisting of 90 days of operation at 100 MWth and 30 days of shutdown. The reactivity worth of the test fuel assembly was about 1.1 dollar. A wide range of burn-up level has been achieved, extending from 42 to 110 MWd/kg HM, the samples with lower MA-to-Pu ratios reaching the highest burn-up. This study has highlighted the importance of the initial MA content, expressed in terms of MA/Pu ratio, on the transmutation rate of MA elements. For (Pu + Am, U) MOX fuel samples, a net build-up of MA is observed when the initial content of MA is very low (here, 1.77 wt% MA/Pu) while a net decrease in MA is observed in the sample with an initial content of 5 wt%. This suggests the existence of some 'equilibrium' initial MA content value beyond which a net transmutation is achievable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Causticizing for Black Liquor Gasifiers

The cost-benefit outlook of black liquor gasification (BLG) could be greatly improved if the smelt causticization step could be achieved in situ during the gasification step. Or, at a minimum, the increase in causticizing load associated with BLG could be mitigated. A number of chemistries have been proven successful during black liquor combustion. In this project, three in situ causticizing processes (titanate, manganate, and borate) were evaluated under conditions suitable for high temperature entrained flow BLG, and low temperature steam reforming of black liquor. The evaluation included both thermodynamic modeling and lab experimentation. Titanate and manganate were tested for complete direct causticizing (to thus eliminate the lime cycle), and borates were evaluated for partial causticizing (to mitigate the load increase associated with BLG). Criteria included high carbonate conversion, corresponding hydroxide recovery upon hydrolysis, non process element (NPE) removal, and economics. Of the six cases (three chemistries at two BLG conditions), only two were found to be industrially viable: titanates for complete causticizing during high temperature BLG, and borates for partial causticizing during high temperature BLG. These two cases were evaluated for integration into a gasification-based recovery island. The Larsen [28] BLG cost-benefit study was used as a reference case for economic forecasting (i.e. a 1500 tpd pulp mill using BLG and upgrading the lime cycle). By comparison, using the titanate direct causticizing process yielded a net present value (NPV) of $25M over the NPV of BLG with conventional lime cycle. Using the existing lime cycle plus borate autocausticizing for extra capacity yielded a NPV of $16M.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing Resilience in Lane Detection Methods: Infrastructure-Based Sensors and Traditional Approaches for Autonomous Vehicles

Traditional autonomous vehicle perception subsystems that use onboard sensors have the drawbacks of high computational load and data duplication. Infrastructure-based sensors, which can provide high quality information without the computational burden and data duplication, are an alternative to traditional autonomous vehicle perception subsystems. However, these technologies are still in the early stages of development and have not been extensively evaluated for lane detection system performance. Therefore, there is a lack of quantitative data on their performance relative to traditional perception methods, especially during hazardous scenarios, such as lane line occlusion, sensor failure, and environmental obstructions. We address this need by evaluating the influence of hazards on the resilience of three different lane detection methods in simulation: (1) traditional camera detection using a U-Net algorithm, (2) radar detections using infrastructure-based radar retro-reflectors (RRs), and (3) direct communication of lane line information using chip-enabled raised pavement markers (CERPMs). The performance of each of these methods is assessed using resilience engineering metrics by simulating the individual methods for each sensor technology’s response to related hazards in the CARLA simulator. Using simulation techniques to replicate these methods and hazards acquires extensive datasets without lengthy time investments. Specifically, the resilience triangle was used to quantitatively measure the resilience of the lane detection system to obtain unique insights into each of the three lane detection methods; notably the infrastructure-based CERPMs and RRs had high resistance to hazards and were not as easily affected as the vision-based U-Net. However, while U-Net was able to recover the fastest from the disruption as compared to the other two methods, it also had the most performance loss. Overall, this study demonstrates that while infrastructure-based lane keeping technologies are still in early development, they have great potential as alternatives to traditional ones.

Patil, Pritesh↗

Using an Energy Performance Based Design-Build Process to Procure a Large Scale Low-Energy Building: Preprint

This paper will review a procurement, acquisition, and contract process of a large-scale replicable net zero energy (ZEB) office building. The owners developed and implemented an energy performance based design-build process to procure a 220,000 ft2 office building with contractual requirements to meet demand side energy and LEED goals. We will outline the key procurement steps needed to ensureachievement of our energy efficiency and ZEB goals. The development of a clear and comprehensive Request for Proposals (RFP) that includes specific and measurable energy use intensity goals is critical to ensure energy goals are met in a cost effective manner. The RFP includes a contractual requirement to meet an absolute demand side energy use requirement of 25 kBtu/ft2, with specificcalculation methods on what loads are included, how to normalize the energy goal based on increased space efficiency and data center allocation, specific plug loads and schedules, and calculation details on how to account for energy used from the campus hot and chilled water supply. Additional advantages of integrating energy requirements into this procurement process include leveraging thevoluntary incentive program, which is a financial incentive based on how well the owner feels the design-build team is meeting the RFP goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OR-AGENT framework – Architecting electrified heavy-duty drayage applications

The widespread adoption of zero-emission vehicles in heavy-duty (HD) commercial freight transportation faces considerable technoeconomic challenges. For heavy-duty trucks, ensuring high uptime, cost parity with diesel, and safety standards is especially critical as these vehicles operate over long distances with heavy loads, where any downtime or off-nominal behaviors significantly impacts logistics, productivity, and the total cost of ownership. Unlike traditional diesel refueling, BEV charging infrastructure must be co-optimized with vehicle deployment, operational demands, and grid capacity to ensure cost-effective and reliable freight operations. However, the lack of a standardized ownership and service model has led to a fragmented approach—where commercial vehicle operators may invest in, own, and maintain both vehicle/batteries and charging/energy infrastructure. This disconnect may exclude energy service providers from the equation, forcing fleet operators to explore ‘behind-the-fence’ energy solutions that increase capital investment, operational downtime, overhead costs, and, in some cases, net carbon emissions. To address these issues, this study introduces OR-AGENT (Optimal Regional Architecture Generation for Efficient National Transport), a comprehensive modeling framework that integrates powertrain architectures, charging infrastructures, and energy backbone systems into a cohesive strategy. In this paper, OR-AGENT is applied to develop an interconnected systems architecture for energy efficiency and resiliency enhancement of heavy-duty drayage vehicles at the Port of Savannah, GA. This framework showcases an interconnected systems approach to electrifying heavy-duty drayage vehicles at the Port of Savannah, GA. The study assessed BEVs with 400–1200 kWh battery capacities, accounting for seasonal variations in weather and freight routing. A diverse charging mix (150 kW–1250 kW) was evaluated alongside grid capacity constraints, cost, and carbon intensity analysis, leading to the development of a strategic microgrid/Distributed Energy Resources (DER) deployment architecture to ensure a reliable and sustainable transition. However, the findings also highlight the need for alternative zero-emission solutions for remaining trips, such as larger batteries, electrified roadways, hydrogen powertrains, or net-zero emission fuels. In conclusion, the findings are incorporated into a Total Cost of Ownership (TCO) model to identify optimal architectures for an interconnected electrified ecosystem.

Commercial vehicles↗