Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron activation system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

A NEW ACCRETION DISK AROUND THE MISSING LINK BINARY SYSTEM PSR J1023+0038

PSR J1023+0038 is an exceptional system for understanding how slowly rotating neutron stars are spun up to millisecond rotational periods through accretion from a companion star. Observed as a radio pulsar from 2007-2013, optical data showed that the system had an accretion disk in 2000/2001. Starting at the end of 2013 June, the radio pulsar has become undetectable, suggesting a return to the previous accretion-disk state, where the system more closely resembles an X-ray binary. In this Letter we report the first targeted X-ray observations ever performed of the active phase and complement them with UV/optical and radio observations collected in 2013 October. We find strong evidence that indeed an accretion disk has recently formed in the system and we report the detection of fast X-ray changes spanning about two orders of magnitude in luminosity. No radio pulsations are seen during low flux states in the X-ray light curve or at any other times.

79 ASTRONOMY AND ASTROPHYSICS↗

Identification of limiting case between DBA and SBDBA (CL break area sensitivity): A new model for the boron injection system

Atucha-2 is a Siemens-designed PHWR reactor under construction in the Republic of Argentina. Its geometrical complexity and (e.g., oblique Control Rods, Positive Void coefficient) required a developed and validated complex three dimensional (3D) neutron kinetics (NK) coupled thermal hydraulic (TH) model. Reactor shut-down is obtained by oblique CRs and, during accidental conditions, by an emergency shut-down system (JDJ) injecting a highly concentrated boron solution (boron clouds) in the moderator tank, the boron clouds reconstruction is obtained using a CFD (CFX) code calculation. A complete LBLOCA calculation implies the application of the RELAP5-3D{sup C} system code. Within the framework of the third Agreement 'NA-SA - Univ. of Pisa' a new RELAP5-3D control system for the boron injection system was developed and implemented in the validated coupled RELAP5-3D/NESTLE model of the Atucha 2 NPP. The aim of this activity is to find out the limiting case (maximum break area size) for the Peak Cladding Temperature for LOCAs under fixed boundary conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

First DIII-D-West hybrid scenario similarity experiments for iter-relevant long-pulse operation

For the first time, similarity experiments between DIII-D and WEST were performed in the ITER "hybrid-like" regime during dedicated campaigns in April and May 2025. The matched parameters include elongation, triangularity, ion ∇B drift direction toward the X-point, qprofile, and core normalized physics quantities in terms of normalized pressure, normalized gyroradius, electron collisionality, ratio of ion to electron temperature, T i /T e . Core transport physics is explored with different aspect ratio (R/a) values (typically 3 at DIII-D and 5 on WEST). DIII-D explored high-beta conditions (electromagnetic effect) with low torque injection (~0 ± 0.5 N•m) using high heating power (up to 6 MW NBI and 2 MW ECRH powers), while scanning the heating mix (ion vs electron), beta, T i /T e , core radiation via controlled tungsten injection using the Laser Blow-Off system. WEST extended operation toward long-duration pulses using its actively cooled tungsten divertor, achieving dominated electron heating regimes with reduced tungsten contamination. Boron impurity injection were scanned on WEST to control edge conditions and core performance. It is found that core confinement improves-manifested by higher electron temperature, total energy content, neutron rate, and ion temperatureunder conditions of low separatrix density, consistent with previous observations [Bourdelle et al., Nucl. Fusion 63 (2023) 056021]. Conditions for Hmode access and for ion heating in electron-dominated regimes in both WEST and DIII-D will be discussed and compared. The ratio of the thermal energy confinement time (τ E ) to the volume-averaged electron-ion collisional heat exchange time (τ e-i ) is a key parameter to enhance ion heating and potentially facilitate H-mode access in electron-heated regimes. These first-of-a-kind coordinated DIII-D and WEST experiments provide a unique multi-machine dataset to validate predictive models and to optimize ITER hybrid-scenario performance under diverse core and edge conditions.

DIII-D↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗

EXPERIENCE WITH THE SNS SC LINAC

The SNS superconducting linac (SCL) is designed to deliver 1 GeV, up to 1.56-MW pulsed H- beams for neutron production. Commissioning of the accelerator systems was completed in June 2006, and the maximum beam energy achieved was approximately 952 MeV. In 2007, the SCL was successfully tuned for 1.01-GeV beam during a test operation. In the linac tune-up, phase scan signature matching, drifting beam measurement, and linac radio frequency cavity phase scaling were applied. In this paper, we will introduce the experiences with the SCL, including the tune-up, beam loss, and beam activation, and briefly discuss beam parameter measurements

43 PARTICLE ACCELERATORS↗

Overview of ten-year operation of the superconducting linear accelerator at the Spallation Neutron Source

The Spallation Neutron Source (SNS) has acquired extensive operational experience of a pulsed proton superconducting linear accelerator (SCL) as a user facility. Numerous lessons have been learned in its first 10 years operation to achieve a stable and reliable operation of the SCL. In this paper, an overview of the SNS SCL design, qualification of superconducting radio frequency (SRF) cavities and ancillary subsystems, an overview of the SNS cryogenic system, the SCL operation including SCL output energy history and downtime statistics, performance stability of the SRF cavities, efforts for SRF cavity performance recovery and improvement at the SNS, and maintenance activities for cryomodules are introduced.

43 PARTICLE ACCELERATORS↗

Cross-section measurement of the 18F(alpha,p)21Ne reaction and possible implication for neutron production in explosive helium burning

At the high temperature and density conditions of hot or explosive helium burning, the {sup 18}F({alpha},p){sup 21}Ne reaction may compete successfully wilh the {sup 18}F({beta}{sup +}{nu}) decay. This suggesls {sup 21}Ne({alpha},n) as an alternative neutron source in Ihe r-process. We have determined the total cross section of the {sup 18}F({alpha},p){sup 21}Ne reaction by studying the time-reverse reaction {sup 21}Ne(p,{alpha}){sup 18}F. Using the activation technique, the total reaction yield was measured in the proton beam energy range of 2.3-4.0 MeV, which corresponds to energies of 0.5-2.1 MeV in the {sup 18}F + {alpha} system. The resulting yield curve was analyzed in terms of the thick target formalism and the R-matrix theory. The reaction rate was deduced experimentally for the first time for the temperature of 0.1 < T{sub 9} < I. The experimemal reaction rate was compared with Hauser-Feshbach predictions. The astrophysical implications of the new rate are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of an Energy Tuning Assembly for High Explosives Detection

The Portable Isotopic Neutron Spectroscopy (PINS) system, employs neutron-induced gamma-ray spectroscopy and provides a nondestructive method for high explosives detection. In standard operation it uses Californium-252 as a neutron source. Operating PINS with a deuterium-tritium (DT) neutron generator has some advantages over Cf-252, including lifetime and ability to produce high-energy inelastic scattering gamma rays. However, current systems using DT neutron generators suffer from a high environmental background and reduced ability to induce neutron capture, reducing spectral quality and limiting nitrogen sensitivity. Here, this study presents the development of an energy-tuning assembly (ETA) designed to optimize the DT neutron energy spectrum to increase nitrogen reaction rates in a target, thereby improving high explosive detection capabilities. A metaheuristic optimization framework, MultiGNOWEE, coupled with MCNP, was employed to generate two ETA configurations: a single-objective ETA, which maximizes nitrogen capture reactions, and a multi-objective ETA, which balances neutron capture and inelastic scattering. Simulations demonstrated the optimized configurations achieved up to a 10-fold improvement in nitrogen capture rates compared to the bare configuration. Experimental validation was conducted using a DT neutron generator and a high-purity germanium (HPGe) detector. Two prototype ETAs were constructed and assessed on a melamine simulant. Measurements demonstrated improved nitrogen detection for both prototype ETA configurations when compared to the standard system.

97 MATHEMATICS AND COMPUTING↗

A Computationally-Efficient, Multi-Mechanism Based Framework for the Comprehensive Modeling of the Evolutionary Behavior of Shape Memory Alloys

The report summarizes the accomplishments made during the 4-year duration of the project. Here, the major emphasis is placed on the different tasks performed by the two research teams; i.e., the modeling activities by the University of Akron (UA) team and the experimental and neutron diffraction studies conducted by the University of Central Florida (UCF) team, during this 4-year period. Further technical details are given in the upcoming sections by UA and UCF for each of the milestones/years (together with the corresponding figures and captions).The project majorly involved the development, validation, and application of a general theoretical model that is capable of capturing the nonlinear hysteretic responses, including pseudoelasticity, shape memory effect, rate-dependency, multi-axiality, asymmetry in tension versus compression response of shape memory alloys. Among the targeted goals for the SMA model was its ability to account for the evolutionary character response (including transient and long term behavior under sustained cycles) for both conventional and high temperature (HT) SMAs, as well as being able to simulate some of the devices which exploit these unique material systems. This required extensive (uniaxial and multi-axial) experiments needed to guide us in calibrating and characterizing the model. Moreover, since the model is formulated on the theoretical notion of internal state variables (ISVs), neutron diffraction experiments were needed to establish the linkage between the micromechanical changes and these ISVs. In addition, the design of the model should allow easy implementation in large scale finite element application to study the behavior of devices making use of these SMA materials under different loading controls. Summary of the activities, progress/achievements made during this period is given below in details for the University of Akron and the University (Section 2.0) of Central Florida (Section 3.0).

Alloys↗

Application of spectral summing to indeterminate suspect low-level drums at Los Alamos National Laboratory

An analytical technique developed by Pajarito Scientific Corporation (PSC), utilizing spectral summing of spectra from groups of drums of similar waste type, is being employed by the Waste Disposition Project - Low Level Waste Disposal (WDP-LLWD) Group at Los Alamos National Laboratory (LANL). This technique has been used to disposition low-level radioactive waste that has dropped out of the transuranic (TRU) category and has no place to go unless it can be proven to be LLW and not TRU. The TRU program at LANL run by Mobile Characterization Services (MCS) employs two High Efficiency Neutron Counters (HENC) with built-in gamma assay systems to assay radioactive waste for shipment and disposal as TRU waste at the Waste Isolation Pilot Plant (WIPP) at Carlsbad, New Mexico. As well as being certified for WIPP assays, the HENC systems can also be used for low-level waste assays for disposal at LANL or off-site disposal facilities, such as the Nevada Test Site (NTS). Some of the waste processed through the HENC systems cannot be confinned TRU due to the absence of detected TRU alpha emitters above the TRU cutoff of 100 nCi/g. This waste becomes suspect low-level waste (SLLW). In many cases, the waste also can't be classified as LLW because the minimum detectable activity (MDA) of TRU radio nuclides is above the 100 nCi/g level. These wastes that do not have enough detectable TRU activity to be classified as TRU waste and have too high a MDA to be classified as LLW enter a radioactive waste characterization indetenninate status that prevents their dispositioning as either TRU waste or LLW. Spectral summing allows an experienced ganuna spectroscopy analyst to add the HENC gamma spectra of a number of similar waste items together to form a consolidated (summed) spectrum. This summed spectrum contains the assay results of the group of items rather than the individual item, and gamma peaks that were not discernable in the individual spectra can become quantifiable in the summed spectrum and the MDA for group sum is reduced. The group of waste items can then be properly classified as LLW based on the summed spectrum and valid assay values can be assigned for disposal. This technique has been successfully applied to a set of 52 debris drums - with individual MDA > 100 nCi/g - with a resulting group total TRU alpha activity concentration below 40nCi/g. Further application of the technique at LANL to other waste drums that are measured on a WIPP certified HENC system is planned and good candidate drum sets are being evaluated as indeterminate situations develop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strong reduction of V{sup 4+} amount in vanadium oxide/hexadecylamine nanotubes by doping with Co{sup 2+} and Ni{sup 2+} ions: Electron paramagnetic resonance and magnetic studies

In this work we present a complete characterization and magnetic study of vanadium oxide/hexadecylamine nanotubes (VO{sub x}/Hexa NT's) doped with Co{sup 2+} and Ni{sup 2+} ions. The morphology of the NT's has been characterized by transmission electron microscopy, while the metallic elements have been quantified by the instrumental neutron activation analysis technique. The static and dynamic magnetic properties were studied by collecting data of magnetization as a function of magnetic field and temperature and by electron paramagnetic resonance. At difference of the majority reports in the literature, we do not observe magnetic dimers in vanadium oxide nanotubes. Also, we observed that the incorporation of metallic ions (Co{sup 2+}, S = 3/2 and Ni{sup 2+}, S = 1) decreases notably the amount of V{sup 4+} ions in the system, from 14-16% (nondoped case) to 2%-4%, with respect to the total vanadium atoms (fact corroborated by XPS experiments) anyway preserving the tubular nanostructure. The method to decrease the amount of V{sup 4+} in the nanotubes improves considerably their potential technological applications as Li-ion batteries cathodes.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Pre-conceptual design activities for the materials plasma exposure experiment

The development of next step fusion facilities such as DEMO or a Fusion Nuclear Science Facility (FNSF) requires first closing technology gaps in a few critical areas. Understanding the material-plasma interface is necessary to enable the development of divertors for long-pulse plasma facilities. A pre-conceptual design for a proposed steady-state linear plasma device, the Materials Plasma Exposure Experiment (MPEX), is underway. A helicon plasma source along with ion cyclotron and electron Bernstein wave heating systems will produce ITER divertor relevant plasma conditions with steady-state parallel heat fluxes of up to 40 MW/m 2 with ion fluxes up to 10 24 /m 2 s on target. Current plans are for the device to use superconducting magnets to produce 1–2 T fields. As a steady-state device, active cooling will be required for components that interact with the plasma (targets, limiters, etc.), as well as for other plasma facing components (transport regions, vacuum tanks, diagnostic ports). Design concepts for the vacuum system, the cooling system, and the plasma heating systems have been completed. The device will include the capability for handling samples that have been neutron irradiated in order to consider the multivariate effects of neutrons, plasma, and high heat-flux on the microstructure of divertor candidate materials. A vacuum cask, which can be disconnected from the high field environment in order to perform in-vacuo diagnosis of the surface evolution is also planned for the facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel design and diagnostics improvements for increased production capacity and improved reliability at the Los Alamos Isotope Production Facility

The Isotope Production Facility (IPF) at Los Alamos National Laboratory (LANL) is used to produce an array of isotopes for medical, global security, and research applications with an intense beam of protons supplied by the linear accelerator at the Los Alamos Neutron Science Center (LANSCE). An Accelerator Improvement Project (AIP) was recently conducted at IPF to improve facility reliability and reduce programmatic risk while increasing general isotope production capacity and flexibility. This was accomplished through the installation of an improved beam window assembly, more robust beam diagnostics, an active and adjustable collimator, and a new beam rastering system. This paper will highlight the four exciting innovations and how they were designed, validated, and installed in parallel as well as the significant operational advantages they provide to IPF. Key experiments and the increased currents achieved in routine production runs demonstrating the enhanced capability from the AIP will be presented. As a result, the most notable capability enhancements include irradiations with beam currents ranging from 100 nA experimental runs up to 300 μA on routine production targets and utilization of a range of cylindrical target diameters.

100 MeV protons↗

Radiochemical capabilities for astrophysics experiments at the national ignition facility

The Nuclear and Radiochemistry Group at Lawrence Livermore National Laboratory (LLNL) has developed a suite of diagnostics and techniques that can be used for astrophysics experiments at the National Ignition Facility (NIF). Capabilities have been developed to add material to the outside of NIF hohlraum assemblies as well as to the interior of NIF target capsules or the fill gas. The ability to place very small amounts of material close to the NIF target enables activation with very large, short-pulse neutron fluxes. The Solid Radiochemistry Diagnostic can be used to collect solid debris from a NIF shot within 2 h of the execution of a shot, and this can be analyzed for radioactive signatures with or without post-shot chemical processing. The Radiochemical Analysis of Gaseous Samples diagnostic system can be used to collect gaseous products produced during a NIF shot. Capsule doping and radiochemical analysis capabilities at NIF will be discussed. The application of these techniques to astrophysical measurements will be discussed as well as some preliminary results.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Iridium and tantalum foils for spaceflight neutron dosimetry.

Description of a two-foil system of iridium and tantalum which can measure thermal and intermediate energy neutrons at flux densities of 1 neutron/sq cm-sec over a ten-day lunar mission (1,000,000 neutrons/sq cm). The foils are chemically inert and nontoxic, weigh less than 1 g each, and require only routine gamma pulse height analysis for activation measurement. Detection of fluences below 1,000,000 neutrons/sq cm are achieved for counts of foil activity made as late as two months following neutron exposure. Tantalum foils flown in Apollo 11 indicated a mean dose equivalent to the astronauts of less than 16 mrem from thermal plus intermediate energy neutrons, while nuclear emulsion track analysis indicated approximately 17 mrem from neutrons of energy greater than 0.6 MeV. Iridium foils flown on Apollo 12 indicated dose equivalents of 1.8 to 2.8 mrem from thermal neutrons, excluding tissue thermalized SNAP-27 neutrons.

English, R. A.↗

Impact of f-element complexation on the radiolytic robustness of separations ligands

Impact of f-element complexation on the radiolytic robustness of separations ligands Gregory P. Horne, Makayla R. Baxter, Corey D. Pilgrim, Travis S. Grimes, Center for Radiation Chemistry Research, Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID, 83415, USA Cristian Celis Barros, Department of Chemistry and Biochemistry, Florida State University, Tallahassee, FL 32306, USA. E-mail: ccelisbarros@fsu.edu Andrew R. Cook, Department of Chemistry, Brookhaven National Laboratory, Upton, New York, 11973, USA Stephen P. Mezyk, Department of Chemistry and Biochemistry, California State University Long Beach, 1250 Bellflower Boulevard, Long Beach, California, 90840-9507, USA The effects of ionizing radiation are ubiquitous throughout all aspects of a nuclear fuel cycle. However, the complexity and intensity of these effects are greatest during the management of used nuclear fuel, owing to the presence of a wide spectrum of radionuclides from neutron capture and fission processes. With regards to used nuclear fuel (UNF) reprocessing, radiation-induced processes typically promote the destruction of active compounds (e.g., complexants and additives) with the concomitant formation of potentially detrimental degradation products and corresponding changes in physical and chemical properties, which ultimately impact the effectiveness and longevity of a given reprocessing system. Concerning UNF complexants, radiation chemistry studies have historically focused on their radiation robustness in the absence of the metal ions they were designed to selectively complex. This knowledge gap is worrisome as previous studies on aqueous phase complexants have demonstrated significant changes in radiolytic behavior upon metal ion complexation.1-4 More recently, the rate of reaction of the n-dodecane radical cation—believed to be the major organic phase radiation-induced transient species responsible for complexant radiolysis in n-dodecane based solvent systems—with hexa-n-octylnitrilo-triacetamide (HONTA) was shown to increase by an order-of-magnitude upon complexation of europium or americium.5 These findings have significant implications on the projected longevity of complexants in UNF reprocessing solvent systems. Consequently, a thorough understanding of metal ion complexation effects on the radiolytic integrity of UNF complexants is essential to evaluate their potential for process application. Presented here are two recent studies from the Idaho National Laboratory Center for Radiation Chemistry Research group that demonstrate the various impacts of f-element complexation (uranium, americium, and lanthanides) on the radiolytic integrity (gamma and electron pulse) of tributyl phosphate (TBP), N,N-di-(2-ethylhexyl)butyramide (DEHBA), N,N-di-2-ethylhexylisobutryamide (DEHiBA), and 2-ethylhexylphosphonic acid mono-2-ethylhexyl ester (HEH[EHP]) under UNF reprocessing conditions. References 1) Bhattacharyya and Kundu, Int. J. Radiat. Phys. Chem., 1971, 3, 1. 2) Kundu and Matuura, Int. J. Radiat. Phys. Chem., 1975, 7, 565. 3) Ilan and Czapski, Biochimica et Biophysica Acta, 1977, 498, 386. 4) Buettner, Doherty, and Patterson, Fed. Euro. Biochem. Soc., 1983, 158 (1), 143. 5) Toigawa, Peterman, Meeker, Grimes, Zalupski, Mezyk, Cook, Yamashita, Kumagai, Matsumura, Horne, PCCP, 2021, 23, 1343.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

EPR/PTFE dosimetry for test reactor environments

The use of Electron Paramagnetic Resonance (EPR) spectroscopy with materials such as alanine is well established as a technique for measurement of ionizing radiation absorbed dose in photon and electron fields such as Co-60, high-energy bremsstrahlung and electron-beam fields [1]. In fact, EPR/Alanine dosimetry has become a routine transfer standard for national standards bodies such as NIST and NPL. In 1992 the Radiation Metrology Laboratory (RML) at Sandia National Laboratories implemented EPR/Alanine capabilities for use in routine and calibration activities at its Co-60 and pulsed-power facilities. At that time it also investigated the usefulness of the system for measurement of absorbed dose in the mixed neutron/photon environments of reactors such as the Sandia Pulsed Reactor and the Annular Core Research Reactor used for hardness testing of electronics. The RML concluded that the neutron response of alanine was a sufficiently high fraction of the overall dosimeter response that the resulting uncertainties in the photon dose would be unacceptably large for silicon-device testing. However, it also suggested that non-hydrogenous materials such as polytetrafluoroethylene (PTFE) would exhibit smaller neutron response and might be useful in mixed environments. Preliminary research with PTFE in photon environments indicated considerable promise, but further development was not pursued at that time. Because of renewed interest in absorbed dose measurements that could better define the individual contributions of photon and neutron components to the overall dose delivered to a test object, the RML has re-initiated the development of an EPR/PTFE dosimetry system. This effort consists of three stages: 1) Identification of PTFE materials that may be suitable for dosimetry applications. It was speculated that the inconsistency of EPR signatures in the earlier samples may have been due to variability in PTFE manufacturing processes. 2) Characterization of dosimetry in photon-only environments. This is necessary to establish requirements for sample preparation, operating parameters and limitations for use in well-defined and predictable environments prior to deployment in the less well-defined mixed environments of test reactors. 3) Characterization of the EPR responses obtained with PTFE in mixed neutron/photon fields. This includes evaluation of the neutron and photon contributions to response, determination of applicable of neutron fluence and photon dose ranges. This paper presents a summary of the research, a description of the EPR/PTFE dosimetry system, and recommendations for preparation and fielding of the dosimetry in photon and mixed neutron/photon environments. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗