Search NASA⌕ Search

SEARCH · Search NASA

Results for “Normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

New measurements of the astrophysical S factor for {sup 12}C(p,{gamma}){sup 13}N reaction at low energies and the asymptotic normalization coefficient (nuclear vertex constant) for the p+{sup 12}C{yields}{sup 13}N reaction

New measurements of differential and total cross sections for the {sup 12}C(p,{gamma}){sup 13}N reaction have been made at beam energies of E{sub p}=354,390,460,463,565,750, and 1061 keV. Analysis of the astrophysical S factor S(E) for the {sup 12}C(p,{gamma}){sup 13}N reaction at low energies and of the reaction rates has been carried out within the R-matrix approach by using the previously measured nuclear vertex constant (or the respective asymptotic normalization coefficient) for the virtual decay {sup 13}N{yields}p+{sup 12}C to fix the direct capture part of the amplitude in S(E). It is demonstrated that the R-matrix approach, using the measured asymptotic normalization coefficient, can be employed as an ideal tool, minimizing the uncertainties associated with a calculation of the direct capture cross section of the {sup 12}C(p,{gamma}){sup 13}N reaction at extremely low energies. New information on the proton and {gamma} width for the first excited state of {sup 13}N is obtained.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cosmological simulations of normal-branch braneworld gravity

We introduce a cosmological model based on the normal branch of Dvali-Gabadadze-Porrati (DGP) braneworld gravity with a smooth dark energy component on the brane. The expansion history in this model is identical to {lambda}CDM, thus evading all geometric constraints on the DGP crossover scale r{sub c}. This well-defined model can serve as a first approximation to more general braneworld models whose cosmological solutions have not been obtained yet. We study the formation of large-scale structure in this model in the linear and nonlinear regime using N-body simulations for different values of r{sub c}. The simulations use the code presented in 25 and solve the full nonlinear equation for the brane-bending mode in conjunction with the usual gravitational dynamics. The brane-bending mode is attractive rather than repulsive in the DGP normal branch, hence the sign of the modified gravity effects is reversed compared to those presented in 25. We compare the simulation results with those of ordinary {lambda}CDM simulations run using the same code and initial conditions. We find that the matter power spectrum in this model shows a characteristic enhancement peaking at k{approx}0.7h/Mpc. We also find that the abundance of massive halos is significantly enhanced. Other results presented here include the density profiles of dark matter halos, and signatures of the brane-bending mode self-interactions (Vainshtein mechanism) in the simulations. Independently of the expansion history, these results can be used to place constraints on the DGP model and future generalizations through their effects on the growth of cosmological structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stability of thin-shell wormholes supported by normal matter in Einstein-Maxwell-Gauss-Bonnet gravity

Recently in [Phys. Rev. D 76, 087502 (2007) and Phys. Rev. D 77, 089903 (2008)] a thin-shell wormhole has been introduced in five-dimensional Einstein-Maxwell-Gauss-Bonnet gravity which was supported by normal matter. We wish to consider this solution and investigate its stability. Our analysis shows that for the Gauss-Bonnet parameter {alpha}<0, stability regions form for a narrow band of finely tuned mass and charge. For the case {alpha}>0, we iterate once more that no stable, normal matter thin-shell wormhole exists.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decoupling of superfluid and normal modes in pulsating neutron stars

We show that equations governing pulsations of superfluid neutron stars can be split into two sets of weakly coupled equations, one describing the superfluid modes and another one, the normal modes. The coupling parameter s is small, |s|{approx}0.01-0.05, for realistic equations of state. Already an approximation s=0 is sufficient to calculate the pulsation spectrum within the accuracy of a few percent. Our results indicate, in particular, that emission of gravitational waves from superfluid pulsation modes is suppressed in comparison to that from normal modes. The proposed approach allows to drastically simplify modeling of pulsations of superfluid neutron stars.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam normal spin asymmetry for the e p → e Δ ( 1232 ) process

Here, we calculate the single spin asymmetry for the $e p \to e \Delta(1232)$ process, for an electron beam polarized normal to the scattering plane. Such single spin asymmetries vanish in the one-photon exchange approximation, and are directly proportional to the absorptive part of a two-photon exchange amplitude. As the intermediate state in such two-photon exchange process is on its mass shell, the asymmetry allows one to access for the first time the on-shell $\Delta \to \Delta$ as well as $N^\ast \to \Delta$ electromagnetic transitions. We present the general formalism to describe the $e p \to e \Delta$ beam normal spin asymmetry, and provide a numerical estimate of its value using the nucleon, $\Delta(1232)$, $S_{11}(1535)$, and $D_{13}(1520)$ intermediate states. We compare our results with the first data from the Qweak@JLab experiment and give predictions for the A4@MAMI experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rheology of dense fiber suspensions: Origin of yield stress, shear thinning, and normal stress differences

We explain the origins of yield stress, shear thinning, and normal stress differences in rigid fiber suspensions. We investigate the interplay between the hydrodynamic, noncontact attractive and repulsive, and interfiber contact interactions. The shear-thinning viscosity and finite yield stress obtained from the Immerse Boundary Method simulations are in quantitative agreement with experiential results from the literature. In this study, we show that attractive interactions result in yield stress and shear thinning rheology in the suspensions of rigid fibers. This is an important finding, given the ongoing discussion regarding the origin of the yield stress for suspensions of fibers. Finally, the ability of the proposed model to quantitatively predict the rheology is not limited to only shear thinning and yield stress but also extends to normal stresses.

42 ENGINEERING↗

Precision Measurement of the Beam-Normal Single-Spin Asymmetry in Forward-Angle Elastic Electron-Proton Scattering

A beam-normal single-spin asymmetry generated in the scattering of transversely polarized electrons from unpolarized nucleons is an observable related to the imaginary part of the two-photon exchange process. Here we report a 2% precision measurement of the beam-normal single-spin asymmetry in elastic electron-proton scattering with a mean scattering angle of θ lab = 7.9 ° and a mean energy of 1.149 GeV. The asymmetry result is B n = – 5.194 ± 0.067 ( stat ) ± 0.082 (syst) ppm. This is the most precise measurement of this quantity available to date and therefore provides a stringent test of two-photon exchange models at far-forward scattering angles ( θ lab → 0 ) where they should be most reliable.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterizing Sub-Cohorts via Data Normalization and Representation Learning

The process of identifying a cohort of interest is a very challenging task. It requires manually inspecting many patient records of complex structure that might include medical coding errors and missing data. This paper presents a computational pipeline for refining the process of cohort selection based on medical concepts recorded in the electronic health records (EHRs). The pipeline extracts EHR data for a given cohort and normalizes this data using standard vocabularies. Then a stacked denoising autoencoder is used to embed the normalized patient vectors in a low dimensional space, where the patients are subsequently clustered into sub-cohorts. The goal is to represent the cohort in a standard format and abstract variants of sub-populations. As a use-case, we applied the pipeline to 1.8 million Veterans diagnosed with major depressive disorder (MDD), and identified four meaningful sub-cohorts using the features learned by the autoencoder. Then, each sub-cohort was explored using a set of keywords for interpretation.

Rush III, Everett↗

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Planetary normal mode computation: Parallel algorithms, performance and reproducibility

This report is an extension of work entitled “Computing planetary interior normal modes with a highly parallel polynomial filtering eigensolver.” by Shi et al., [1] originally presented at the SC18 conference. A highly parallel polynomial filtered eigensolver was developed and exploited to calculate the planetary normal modes. The proposed method is ideally suited for computing interior eigenpairs for large-scale eigenvalue problems as it greatly enhances memory and computational efficiency. In this article, the second-order finite element method is used to further improve the accuracy as only the first-order finite element method was deployed in the previous work. The parallel algorithm, its parallel performance up to 20k processors, and the great computational accuracy are illustrated. The reproducibility of the previous work was successfully performed on the Student Cluster Competition at the SC19 conference by several participant teams using a completely different Mars-model dataset on different clusters. Both weak and strong scaling performances of the reproducibility by the participant teams were impressive and encouraging. The analysis and reflection of their results are demonstrated and future direction is discussed.

97 MATHEMATICS AND COMPUTING↗

Fabrication of anodic aluminum oxide on silica optical fiber with nanopore channels oriented off surface normal

Abstract Aluminum coating on silica optical fiber was anodized by applying an electric field off‐axis to surface normal of the fiber coating with simulation of the electric field lines between angularly positioned anode and cathode as a guide. The nanostructure features, including nanopore orientation, of the resultant anodized aluminum oxide (AAO) were characterized using scanning electron microscopy. This unique off‐axis electric field arrangement enabled the formation of AAO with uniformly tilted nanopore channel arrays. Nanopore channels with tilting angles around 10°–20° relative to surface normal of AAO were obtained. These results are in general agreement with the simulated electric field lines between the anode and cathode.

Materials Science↗

SU-E-T-501: Normal Tissue Toxicities of Pulsed Low Dose Rate Radiotherapy and Conventional Radiotherapy: An in Vivo Total Body Irradiation Study

Purpose: Pulsed low dose rate radiotherapy (PLDR) is a re-irradiation technique for therapy of recurrent cancers. We have previously shown a significant difference in the weight and survival time between the mice treated with conventional radiotherapy (CRT) and PLDR using total body irradiation (TBI). The purpose of this study was to investigate the in vivo effects of PLDR on normal mouse tissues.Materials and Methods: Twenty two male BALB/c nude mice, 4 months of age, were randomly assigned into a PLDR group (n=10), a CRT group (n=10), and a non-irradiated control group (n=2). The Siemens Artiste accelerator with 6 MV photon beams was used. The mice received a total of 18Gy in 3 fractions with a 20day interval. The CRT group received the 6Gy dose continuously at a dose rate of 300 MU/min. The PLDR group was irradiated with 0.2Gyx20 pulses with a 3min interval between the pulses. The mice were weighed thrice weekly and sacrificed 2 weeks after the last treatment. Brain, heart, lung, liver, spleen, gastrointestinal, urinary and reproductive organs, and sternal bone marrow were removed, formalin-fixed, paraffin-embedded and stained with H and E. Morphological changes were observed under a microscope. Results: Histopathological examination revealed atrophy in several irradiated organs. The degree of atrophy was mild to moderate in the PLDR group, but severe in the CRT group. The most pronounced morphological abnormalities were in the immune and hematopoietic systems, namely spleen and bone marrow. Brain hemorrhage was seen in the CRT group, but not in the PLDR group. Conclusions: Our results showed that PLDR induced less toxicity in the normal mouse tissues than conventional radiotherapy for the same dose and regimen. Considering that PLDR produces equivalent tumor control as conventional radiotherapy, it would be a good modality for treatment of recurrent cancers.

60 APPLIED LIFE SCIENCES↗

SU-E-I-78: Establishing a Protocol for Quick Estimation of Thyroid Internal Contamination with 131I in Normal and Emergency Situations

Purpose: I-131 is one of the most frequent radionuclides used in nuclear medicine departments. The radiation workers, who manipulate the unsealed radio-toxic iodine, should be monitored for internal contamination. In this study a protocol was established for estimating I-131 activity absorbed in the thyroid glands of the nuclear medicine staff in normal working condition and also in accidents. Methods: I-131 with the activity of 10 μCi was injected inside the thyroid gland of a home-made anthropomorphic neck phantom. The phantom is made up of PMMA as soft tissue, and Aluminium as bone. The dose rate at different distances from the surface of the neck phantom was measured using a scintillator detector for duration of two months. Then, calibration factors were obtained, for converting the dose rate at each distance to the iodine activity inside the thyroid. Results: According to the results of this study, the calibration factors for converting the dose rates (nSv/h) at distances of 0cm, 1cm, 6cm, 11cm, and 16cm to the activity (kBq) inside the thyroid were found to be 0.03, 0.04, 0.14, 0.29, and 0.49 . Conclusion: This method can be effectively used for quick estimation of the I-131 concentration inside the thyroid of the staff for daily checks in normal working conditions and also in accidents.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-230: Evaluation of ViewRay 0.35 T MRI Normal Structure Segmentation

Purpose: In order to take advantage of the high resolution soft tissue imaging available in MR images, we investigated 3D images obtained with the low field 0.35 T MR in ViewRay to serve as an alternative to CT scans for radiotherapy treatment planning. In these images, normal and target structure delineation can be visualized. Assessment is based upon comparison with the CT images and the ability to produce comparable contours. Methods: Routine radiation oncology CT scans were acquired on five patients. Contours of brain, brainstem, esophagus, heart, lungs, spinal cord, and the external body were drawn. The same five patients were then scanned on the ViewRay TrueFISP-based imaging pulse sequence. The same organs were selected on the MR images and compared to those from the CT scan. Physical volume and the Dice Similarity Coefficient (DSC) were used to assess the contours from the two systems. Image quality stability was quantitatively ensured throughout the study following the recommendations of the ACR MR accreditation procedure. Results: The highest DSC of 0.985, 0.863, and 0.843 were observed for brain, lungs, and heart respectively. On the other hand, the brainstem, spinal cord, and esophagus had the lowest DSC. Volume agreement was most satisfied for the heart (within 5%) and the brain (within 2%). Contour volume for the brainstem and lung (a widely dynamic organ) varied the most (27% and 19%). Conclusion: The DSC and volume measurements suggest that the results obtained from ViewRay images are quantitatively consistent and comparable to those obtained from CT scans for the brain, heart, and lungs. MR images from ViewRay are well-suited for treatment planning and for adaptive MRI-guided radiotherapy. The physical data from 0.35 T MR imaging is consistent with our geometrical understanding of normal structures.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-04: Characterization of Fan Beam Coded Aperture Coherent Scatter Spectral Imaging Methods for Differentiation of Normal and Neoplastic Breast Structures

Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

SU-C-BRC-01: A Monte Carlo Study of Out-Of-Field Doses From Cobalt-60 Teletherapy Units Intended for Historical Correlations of Dose to Normal Tissue

Purpose: Innovations in radiotherapy treatments, such as dynamic IMRT, VMAT, and SBRT/SRS, result in larger proportions of low-dose regions where normal tissues are exposed to low doses levels. Low doses of radiation have been linked to secondary cancers and cardiac toxicities. The AAPM TG Committee No.158 entitled, ‘Measurements and Calculations of Doses outside the Treatment Volume from External-Beam Radiation Therapy’, has been formed to review the dosimetry of non-target and out-of-field exposures using experimental and computational approaches. Studies on historical patients can provide comprehensive information about secondary effects from out-of-field doses when combined with long-term patient follow-up, thus providing significant insight into projecting future outcomes of patients undergoing modern-day treatments. Methods: We present a Monte Carlo model of a Theratron-1000 cobalt-60 teletherapy unit, which historically treated patients at the University of Florida, as a means of determining doses located outside the primary beam. Experimental data for a similar Theratron-1000 was obtained at the University of Wisconsin’s ADCL to benchmark the model for out-of-field dosimetry. An Exradin A12 ion chamber and TLD100 chips were used to measure doses in an extended water phantom to 60 cm outside the primary field at 5 and 10 cm depths. Results: Comparison between simulated and experimental measurements of PDDs and lateral profiles show good agreement for in-field and out-of-field doses. At 10 cm away from the edge of a 6×6, 10×10, and 20×20 cm2 field, relative out-of-field doses were measured in the range of 0.5% to 3% of the dose measured at 5 cm depth along the CAX. Conclusion: Out-of-field doses can be as high as 90 to 180 cGy assuming historical prescription doses of 30 to 60 Gy and should be considered when correlating late effects with normal tissue dose.

60 APPLIED LIFE SCIENCES↗

SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered. Research reported in this paper was supported in part by the National Cancer Institute of the National Institutes of Health under award R01CA181081. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Institue of Health.

60 APPLIED LIFE SCIENCES↗

SU-F-J-174: A Series of Computational Human Phantoms in DICOM-RT Format for Normal Tissue Dose Reconstruction in Epidemiological Studies

Purpose: Epidemiological studies of second cancer risk in radiotherapy patients often require individualized dose estimates of normal tissues. Prior to 3D conformal radiation therapy planning, patient anatomy information was mostly limited to 2D radiological images or not even available. Generic patient CT images are often used in commercial radiotherapy treatment planning system (TPS) to reconstruct normal tissue doses. The objective of the current work was to develop a series of reference size computational human phantoms in DICOM-RT format for direct use in dose reconstruction in TPS. Methods: Contours of 93 organs and tissues were extracted from a series of pediatric and adult hybrid computational human phantoms (newborn, 1-, 5-, 10-, 15-year-old, and adult males and females) using Rhinoceros software. A MATLAB script was created to convert the contours into the DICOM-RT structure format. The simulated CT images with the resolution of 1×1×3 mm3 were also generated from the binary phantom format and coupled with the DICOM-structure files. Accurate volumes of the organs were drawn in the format using precise delineation of the contours in converted format. Due to complex geometry of organs, higher resolution (1×1×1 mm3) was found to be more efficient in the conversion of newborn and 1-year-old phantoms. Results: Contour sets were efficiently converted into DICOM-RT structures in relatively short time (about 30 minutes for each phantom). A good agreement was observed in the volumes between the original phantoms and the converted contours for large organs (NRMSD<1.0%) and small organs (NRMSD<7.7%). Conclusion: A comprehensive series of computational human phantoms in DICOM-RT format was created to support epidemiological studies of second cancer risks in radiotherapy patients. We confirmed the DICOM-RT phantoms were successfully imported into the TPS programs of major vendors.

60 APPLIED LIFE SCIENCES↗