Search NASA⌕ Search

SEARCH · Search NASA

Results for “OPTICAL REFLECTIVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Speckle interferometry using fiber optic phase stepping

A system employing closed-loop phase-stepping is used to measure the out-of-plane deformation of a diffusely reflecting object. Optical fibers are used to provide reference and object beam illumination for a standard two-beam speckle interferometer, providing set-up flexibility and ease of alignment. Piezoelectric fiber-stretchers and a phase-measurement/servo system are used to provide highly accurate phase steps. Intensity data is captured with a charge-injection-device camera, and is converted into a phase map using a desktop computer. The closed-loop phase-stepping system provides 90 deg phase steps which are accurate to 0.02 deg, greatly improving this system relative to open-loop interferometers. The system is demonstrated on a speckle interferometer, measuring the rigid-body translation of a diffusely reflecting object with an accuracy + or - 10 deg, or roughly + or - 15 nanometers. This accuracy is achieved without the use of a pneumatically mounted optics table.

Mercer, Carolyn R.↗

Contamination effects study

The in-situ optical surface measurement system is a facility designed to study the deleterious effects of particulate materials on the surface reflectivities of optical materials in the vacuum ultraviolet (VUV). This arrangement is designed to simulate the on-orbit effects of contamination and degradation of optical surfaces. This simulation is accomplished through the use of non-coherent VUV sources illuminating optical surfaces located in a high vacuum chamber. Several sources of contamination are employed. The reflectivity is measured both at the specular reflection as well as at two scattered positions, forward and reverse. The system components are described and an operating procedure is given.

Source record↗

2D microwave imaging reflectometer electronics

A 2D microwave imaging reflectometer system has been developed to visualize electron density fluctuations on the DIII-D tokamak. Simultaneously illuminated at four probe frequencies, large aperture optics image reflections from four density-dependent cutoff surfaces in the plasma over an extended region of the DIII-D plasma. Localized density fluctuations in the vicinity of the plasma cutoff surfaces modulate the plasma reflections, yielding a 2D image of electron density fluctuations. Details are presented of the receiver down conversion electronics that generate the in-phase (I) and quadrature (Q) reflectometer signals from which 2D density fluctuation data are obtained. Also presented are details on the control system and backplane used to manage the electronics as well as an introduction to the computer based control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber optic microphone having a pressure sensing reflective membrane and a voltage source for calibration purpose

A fiber optic microphone is provided for measuring fluctuating pressures. An optical fiber probe having at least one transmitting fiber for transmitting light to a pressure-sensing membrane and at least one receiving fiber for receiving light reflected from a stretched membrane is provided. The pressure-sensing membrane may be stretched for high frequency response. Further, a reflecting surface of the pressure-sensing membrane may have dimensions which substantially correspond to dimensions of a cross section of the optical fiber probe. Further, the fiber optic microphone can be made of materials for use in high temperature environments, for example greater than 1000 F. A fiber optic probe is also provided with a back plate for damping membrane motion. The back plate further provides a means for on-line calibration of the microphone.

Zuckerwar, Allan J.↗

Studies of dust grain properties in infrared reflection nebulae

A model has been developed for reflection nebulae around luminous IR sources embedded in dense dust clouds. The shape of the IR spectrum is shown to be the result of a combination of the scattering properties of the dust, the spectrum of the illuminating source, and foreground extinction, while geometry plays a minor role. Comparison of the model results with IR observations of the reflection nebula surrounding OMC-2/IRS 1 shows that either a grain size distribution like that found in the diffuse ISM, or consisting of larger grains, can explain the observed shape of the spectrum. However, the absolute intensity level of the scattered light, as well as the observed polarization, requires large grains. By adding water-ice mantles to the silicate and graphite cores, the 3.08 micron ice-band feature observed in the spectra of several IR reflection nebulae has been modeled. It is shown that this ice band arises naturally in optically thick reflection nebulae containing ice-coated grains.

Pendleton, Y. J.↗

Relation of the diffuse reflectance remission function to the fundamental optical parameters.

The Kubelka-Munk equations describing the diffuse reflectance of a powdered sample were compared to equations obtained using a uniformly-sized rough-surfaced spherical particle model. The comparison resulted in equations relating the remission function and the Kubelka-Munk constants to the index of refraction, the absorption coefficient, and the average particle diameter of a powdered sample. Published experimental results were used to test the equation relating to the remission function to the fundamental optical parameters.

Simmons, E. L.↗

Innovative FT-IR Imaging of Protein Film Secondary Structure Before and After Heat Treatment

Changes in the secondary structure of globular protein occur during thermal processing. An infrared reflecting mirrored optical substrate that is unaffected by heat allows recording infrared spectra of protein films in a reflection absorption mode on the stage of an FT-IR microspectrometer. Hydrated films of myoglobin protein cast from solution on the mirrored substrate are interrogated before and after thermal denaturation to allow a direct comparison. Focal plane array imaging of 280 protein films allowed selection of the same area in the image from which to extract spectra. After treatment, 110 of 140 spectra from multiple films showed a dramatic shift from the {alpha}-helix form (1650 {+-} 5 cm{sup -1}) to aggregated forms on either side of the original band. Seventy maxima were near 1625 cm{sup -1}, and 40 shifted in the direction of 1670 cm{sup -1}. The method developed was applied to films cast from two other commercial animal and plant protein sources.

59 BASIC BIOLOGICAL SCIENCES↗

TH-C-17A-12: Integrated CBCT and Optical Tomography System On-Board a Small Animal Radiation Research Platform (SARRP)

Purpose: We present a newly developed on-board optical tomography system for SARRP. Innovative features include the compact design and fast acquisition optical method to perform 3D soft tissue radiation guidance. Because of the on-board feature and the combination of the CBCT, diffusive optical tomography (DOT), bioluminescence and fluorescence tomography (BLT and FT), this integrated system is expected to provide more accurate soft tissue guidance than an off-line system as well as highly sensitive functional imaging in preclinical research. Methods: Images are acquired in the order of CBCT, DOT and then BLT/FT, where the SARRP CBCT and DOT are used to provide the anatomical and optical properties information to enhance the subsequent BLT/FT optical reconstruction. The SARRP stage is redesigned to include 9 imbedded optical fibers in contact with the animal's skin. These fibers, connected to a white light lamp or laser, serve as the light sources for the DOT or FT, respectively. A CCD camera with f/1.4 lens and multi-spectral filter set is used as the optical detector and is mounted on a portable cart ready to dock into the SARRP. No radiation is delivered during optical image acquisition. A 3-way mirror system capable of 180 degree rotation around the animal reflects the optical signal to the camera at multiple projection angles. A special black-painted dome covers the stage and provides the light shielding. Results: Spontaneous metastatic bioluminescent liver and lung tumor models will be used to validate the 3D BLT reconstruction. To demonstrate the capability of our FT system, GastroSense750 fluorescence agent will be used to imaging the mouse stomach and intestinal region in 3D. Conclusion: We expect that this integrated CBCT and optical tomography on-board a SARRP will present new research opportunities for pre-clinical radiation research. Supported by NCI RO1-CA 158100.

60 APPLIED LIFE SCIENCES↗

Calculating the bidirectional reflectance of natural vegetation covers using Boolean models and geometric optics

The bidirectional radiance or reflectance of a forest or woodland can be modeled using principles of geometric optics and Boolean models for random sets in a three dimensional space. This model may be defined at two levels, the scene includes four components; sunlight and shadowed canopy, and sunlit and shadowed background. The reflectance of the scene is modeled as the sum of the reflectances of the individual components as weighted by their areal proportions in the field of view. At the leaf level, the canopy envelope is an assemblage of leaves, and thus the reflectance is a function of the areal proportions of sunlit and shadowed leaf, and sunlit and shadowed background. Because the proportions of scene components are dependent upon the directions of irradiance and exitance, the model accounts for the hotspot that is well known in leaf and tree canopies.

Strahler, Alan H.↗

Applying Orbital Multi-Angle Photopolarimetric Observations to Study Properties of Aerosols in the Earth's Atmosphere: Implications of Measurements in the 1.378 µm Spectral Channel to Retrieve Microphysical Characteristics and Composition of Stratospheric Aerosols

We analyze the possibilities of orbital photopolarimetric measurements to study properties of aerosols in the Earth's atmosphere. As an example, we consider the case when such measurements are performed within a narrow spectral channel centered at 1.378 µm that allows to retrieve microphysical characteristics of stratospheric aerosols separately from those of tropospheric aerosols. We consider the case of stratospheric aerosols caused by volcanic eruption, and adopt the model of the stratosphere in the form of a homogeneous plane-parallel layer composed of polydisperse spherical particles. We use numerically exact solutions of the vector radiative transfer equation to theoretically simulate measurements carried out at various numbers of scattering angles, including: (i) radiance measurements alone; (ii) polarization measurements alone; and (iii) radiance and polarization measurements together. The results of computations show that the simultaneous use of radiance and polarization measurements at a sufficiently large number of scattering angles enables one to retrieve the optical thickness, effective radius, and refractive index of aerosols with adequate accuracy. We demonstrate how the accuracy of the derived values of the optical parameters of aerosols depends on the accuracy of measurements of the intensity and polarization of the reflected light, optical thickness of aerosol layer itself, effective radius of aerosols, width of the particle size distribution, and number of viewing angles.

Aerosols↗

Actinic EUV mask inspection beyond 0.25 NA

Operating at EUV wavelengths, the SEMATECH Berkeley Actinic Inspection Tool (AIT) is a zoneplate microscope that provides high quality aerial image measurements in routine operations for SEMATECH member companies. We have upgraded the optical performance of the AIT to provide multiple image magnifications, and several inspection NA values up to 0.35 NA equivalent (0.0875 mask-side). We report on the improved imaging capabilities including resolution below 100-nm on the mask side (25 nm, 4x wafer equivalent). EUV reticles are intricate optical systems made from of several materials with wavelength-specific optical properties. The combined interactions of the substrate, multilayer-stack, buffer layer and absorber layer produce a reflected EUV optical field that is challenging to model accurately, and difficult to fully assess without actinic at-wavelength inspection. Understanding the aerial image from lithographic printing alone is complicated by photoresist properties. The AIT is now used to investigate mask issues such as amplitude and phase defect printability, pattern repair techniques, contamination, inspection damage, and mask architecture. The AIT has a 6{sup o} illumination angle, and high-resolution exposure times are typically 20 seconds per image. The AIT operates semi-automatically capturing through-focus imaging series with step sizes as small as 0.1 {micro}m (0.5-0.8 {micro}m are typical), and a step resolution of 0.05 {micro}m. We believe it is the most advanced EUV mask inspection tool in operation today. In the AIT, an EUV image of the mask is projected by a zoneplate lens with high magnification (680-910x) onto a CCD camera. The CCD over-samples the image, providing equivalent pixel sizes down to 15 nm in mask coordinates-several image pixels per resolution element. The original AIT zoneplate specifications were designed to emulate the resolution of a 0.25-NA 4x stepper, and thorough benchmarking analysis of the aberrations, flare, contrast-transfer function, and coherence was published in 2007 [1] (see Fig 1). Recent upgrades have also included changes to improve the illumination uniformity and increase the partial coherence {sigma} value. Five different zoneplate lenses are installed side-by-side to enable the AIT to emulate various stepper optical properties (see Fig. 2).

36 MATERIALS SCIENCE↗

In situ spectral calibration method for the impurity influx monitor (divertor) for ITER using angled physical contact fibers

The in situ calibration method for the impurity influx monitor (divertor) is experimentally examined. The total reflectance of the optical path from the focal point of the Cassegrain telescope to the first mirror is derived using a micro retroreflector array. An optical fiber with angled physical contact (APC) connectors reduces the return edge reflection. APC fibers and a multimode coupler increase the signal-to-noise ratio by about one order compared to that of triple-branched fibers and enable measurement of the wavelength dependence of the total reflectance of the optical system even after potential deterioration of mirror surfaces reduces reflectance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Comparison of Emerging and Industry Benchmark Photovoltaic Backsheets Between Different Outdoor Locations

Recent interest within the photovoltaic (PV) module industry is largely directed toward enhanced lifetimes in the field, balanced with improved recyclability. Traditionally, fluoropolymer-based backsheets have been used, however, are difficult to recycle. Emerging polyolefin (PO)-based backsheets are more recyclable and can be formulated to be robust. Properties of different fluoropolymer- and non-fluoropolymer-based backsheet coupons and in encapsulated silicon mini modules that have been fielded in Albuquerque, NM and Cocoa, FL are reported here. Seven backsheets were examined: two novel PO's, TPT, APO, PPE, AAA, and KPf. Methods of examination include module electrical performance (I - V flash test), surface morphology (optical microscope and gloss), polymer chemical structure (FTIR), EL imaging, mechanical tensile testing, DC breakdown voltage, DSC (phase transitions), and optical performance (reflectance spectra).

industries↗

Evaluation and study of advanced optical contamination, deposition, measurement, and removal techniques

A program is described to design, fabricate and install an experimental work chamber assembly (WCA) to provide a wide range of experimental capability. The WCA incorporates several techniques for studying the kinetics of contaminant films and their effect on optical surfaces. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation. Several supporting studies were conducted to define specific chamber requirements, to determine the sensitivity of the measurement techniques to be incorporated in the chamber, and to establish procedures for handling samples prior to their installation in the chamber. A bibliography and literature survey of contamination-related articles is included.

Linford, R. M. F.↗

A system for the study of molecular contamination

An experimental vacuum chambers was designed and fabricated to provide a wide range of experimental capability. This work chamber assembly (WCA) was conceived to establish the proof-of-principle of various techniques for studying the kinetics of contaminants and their effects. It incorporates the capability for depositing both optical and contaminant films on temperature-controlled samples, and for in-situ measurements of the vacuum ultraviolet reflectance. Ellipsometer optics are mounted on the chamber for film thickness determinations, and other features include access ports for radiation sources and instrumentation.

Dillow, C. F.↗

Demonstration of plasma mirror capability for the OMEGA Extended Performance laser system

A plasma mirror platform was developed for the OMEGA-EP facility to redirect beams, thus enabling more flexible experimental configurations as well as a platform that can be used in the future to improve laser contrast. The plasma mirror reflected a short pulse focusing beam at 22.5° angle of incidence onto a 12.5 μm thick Cu foil, generating Bremsstrahlung and k α x rays, and accelerating ions and relativistic electrons. By measuring these secondary sources, the plasma mirror key performance metrics of integrated reflectivity and optical quality are inferred. It is shown that for a 5 ± 2 ps, 310 J laser pulse, the plasma mirror integrated reflectivity was 62 ± 13% at an operating fluence of 1670 J cm –2 , and that the resultant short pulse driven particle acceleration and x-ray generation indicate that the on target intensity was 3.1 × 10 18 W cm –2 , which is indicative of a good post-plasma mirror interaction beam optical quality. By deriving the plasma mirror performance metrics from the secondary source scalings, it was simultaneously demonstrated that the plasma mirror is ready for adoption in short pulse particle acceleration and high energy photon generation experiments using the OMEGA-EP system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

How reduced vacuum pumping capability in a coating chamber affects the laser damage resistance of HfO 2 /SiO 2 antireflection and high-reflection coatings

Here, optical coatings with the highest laser damage thresholds rely on clean conditions in the vacuum chamber during the coating deposition process. A low-base pressure in the coating chamber, as well as the ability of the vacuum system to maintain the required pressure during deposition, are important aspects of limiting the amount of defects in an optical coating that could induce laser damage. Our large optics coating chamber at Sandia National Laboratories normally relies on three cryo pumps to maintain low pressures for e-beam coating processes. However, on occasion, one or more of the cryo pumps have been out of commission. In light of this circumstance, we explored how deposition under compromised vacuum conditions resulting from the use of only one or two cryo pumps affects the laser-induced damage thresholds of optical coatings. The coatings of this study consist of HfO 2 and SiO 2 layer materials and include antireflection coatings for 527 nm at normal incidence and high-reflection coatings for 527 nm at 45-deg angle of incidence in P-polarization.

36 MATERIALS SCIENCE↗