Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Numerical simulation of frost formation and heat transfer on fin-and-tube heat exchangers in turbulent cross-flow

Frost formation in fin-and-tube heat exchangers in turbulent cross-flow presents significant challenges in industrial refrigeration applications, affecting heat transfer efficiency and operational reliability. The purpose of this work is to investigate frost deposition and growth on a staggered bank of a fin-and-tube freezer coil under turbulent forced convection conditions. The focus here is on investigating conditions that closely replicate real-world scenarios in large walk-in industrial freezers. Using a direct numerical simulation approach, we examine the flow dynamics and thermal behaviour in the presence of frost, considering turbulent regimes characterized by a Reynolds number in the range 1050 ≤ R e D , avg ≤ 4800 , with the characteristic length being the outer diameter of the tube and the velocity being the bulk fluid velocity between the plates (fins). Computational fluid dynamics simulations are employed to resolve the interactions between turbulent airflow and the frost layer. Our approach incorporates a modified immersed boundary method and a slow-time acceleration technique to address the complex dynamic interface between the continuously evolving frost layer and the flowing air stream. Our findings indicate that frost forms more on the sides of the finned surfaces (plates) and less on the tubes themselves. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics↗

The Continuous Electron Beam Accelerator Facility at 12 GeV

This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of 20 MV / m . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Design of the EIC hadron storage ring stripline injection kicker with a novel impedance tuning capability

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will be a high luminosity (~10 34 cm –2 s –1 ) nuclear science facility. To facilitate EIC experiments, the existing yellow ring of the Relativistic Heavy Ion Collider (RHIC) will be reconfigured to serve as the Hadron Storage Ring (HSR). Designing a stripline injection kicker for the HSR beams, with high magnetic rigidity (~ 82 Tm), poses some technical challenges due to the required large pulsed voltage with long flattop duration, very fast rise time, expected shorter bunch spacing, and potential heating due to higher peak current. In addition, minimizing impedance mismatch in the transition region between the feedthrough and the stripline electrode is challenging. This paper focuses on the mechanical design and optimization of the HSR injection kicker, highlighting a novel impedance tuning capability achieved through an innovative kicker aperture adjustment mechanism. We comprehensively cover the design, including impedance optimization (both beam coupling and characteristic), beam-induced heating, and thermal analysis, and investigation of the maximum electric field due to high voltage signal excitation to ensure safe and reliable operation.

43 PARTICLE ACCELERATORS↗

Dose Rate Effects in the Aging of Nuclear Cable Insulation Subjected to Gamma Radiation

In nuclear power plants (NPPs), the aging of polymer-based electrical cable insulation must be effectively monitored to ensure the safe and reliable operation of NPPs. Gamma radiation is one of the main environmental stressors causing degradation of cable insulation. For a given total dose of absorbed gamma radiation, damage due to gamma irradiation may be dose rate dependent. The purpose of this work is to confirm whether a dose rate effect exists for the cable insulation made by crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR), quantify the relationship between degradation rate and dose rate, and explore the correlation of different measured properties. The dose rate effects at 1800 Gy/h, 200 Gy/h, and 100 Gy/h using 60Co gamma irradiation on cable aging was studied. Different types of cable insulation, including two XLPEs and one EPR, were irradiated at the different dose rates with a total dose around 300 kGy at 26 °C. The properties of unirradiated and irradiated samples were characterized by mass change, yellowness index, and other ongoing measurements. Dose rate effects were observed for mass change data of XLPE and EPR.

Li, Donghui↗

Automated qualification and analysis of protective spark gaps for DC accelerators

Protective spark gaps are used in the high voltage multiplier column of a 3 MeV DC Accelerator to prevent excessive voltage build-ups. Precise gap of 5 mm is maintained between the electrodes in these spark gaps for obtaining 120 kV± 5 kV in 6 kg/cm{sup 2} SF{sub 6} environment which is the dielectric medium. There are 74 such spark gaps used in the multiplier. Each spark gap has to be qualified for electrical performance before fitting in the accelerator to ensure reliable operation. As the breakdown voltage stabilizes after a large number of sparks between the electrodes, the qualification process becomes time consuming and cumbersome. For qualifying large number of spark gaps an automatic breakdown analysis setup has been developed. This setup operates in air, a dielectric medium. The setup consists of a flyback topology based high voltage power supply with maximum rating of 25 kV. This setup works in conjunction with spark detection and automated shutdown circuit. The breakdown voltage is sensed using a peak detector circuit. The voltage breakdown data is recorded and statistical distribution of the breakdown voltage has been analyzed. This paper describes details of the diagnostics and the spark gap qualification process based on the experimental data. (author)

43 PARTICLE ACCELERATORS↗

Privacy-Preserving Aggregation of Controllable Loads to Compensate Fluctuations in Solar Power

Cybersecurity and privacy are of the utmost importance for safe, reliable operation of the electric grid. It is well known that the increased connectivity/interoperability between all stakeholders (e.g., utilities, suppliers, and consumers) will enable personal information collection. Significant advanced metering infrastructure (AMI) deployment and demand response (DR) programs across the country, while enable enhanced automation, also generate energy data on individual consumers that can potentially be used for exploiting privacy. Inspired by existing works which consider DR, battery-based perturbation, and differential privacy noise adding, we novelly consider the aggregator (cluster) level privacy issue in the DR framework of solar photovoltaic (PV) generation following. Different from most of the existing works which mainly rely on the charging/discharging scheduling of rechargeable batteries, we utilize controllable building loads to serve as virtual storage devices to absorb a large portion of the PV genertaion while delicately keeping desired noisy terms to satisfy the differential privacy for the raw load profiles at the aggregator level. This not only ensures differential privacy, but also improves the DR efficiency in load following since part of the noisy signal in solar PV generation has been filtered out. In particular, a mixed integer quadratic optimization problem is formulated to optimally dispatch a population of on/off controllable loads to achieve this privacy-preserving DR service.

Dong, Jin↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Developing Use Cases for Evaluation of ADMS Applications to Accelerate Technology Adoption: Preprint

Grid modernization for the distribution systems comprise of the ability to effectively monitor and manage unplanned events while ensuring reliable operations. Integration of Distributed Energy Resources (DERs) and proliferation of autonomous smart controllers like microgrids and smart inverters in the distribution networks challenge the status quo of distribution system operations. Advanced Distribution Management System (ADMS) technologies are being increasingly deployed to manage the complexities of operating distribution systems. The ability to evaluate the ADMS applications in specific utility environments and for future scenarios will accelerate wider adoption of the ADMS and will lower the risks and costs of their implementation. This paper addresses the first step - identify and define the use cases for evaluating these applications. The applications that are selected for this discussion include Volt-VAr Optimization (VVO), Fault Location Isolation and Service Restoration (FLISR), Online Power Flow (OLPF)/Distribution System State Estimation (DSSE) and Market Participation. A technical description and general operational requirements for each of these applications is presented. The test scenarios that are most relevant to the utility challenges are also addressed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Convolutional Neural Network-Based Protection-Zone Classification of Faults in Distribution Feeders with Photovoltaics.

Fault detection and isolation is critical for reliable operation of distribution systems. The ride-through requirements for the distributed energy resources (DER), mandated by the IEEE 1547-2018 standard, makes it challenging to use undervoltage (UV) conditions for fault detection. In addition, with low fault current contribution from these inverter-based DERs, the time-overcurrent relays are also less effective. Thus motivated, this paper presents a learning-based approach for fault detection and localization. A convolutional neural network (CNN)-based model is proposed which uses local voltage and current waveforms from DER locations and feeder substations, for training a zonal classifier. The classifier can be adopted into any relay-like device for discriminating between faults originating from different protection zones. The performance of the proposed approach was tested on publicly available test feeders with distributed photovoltaics (PVs).

Fault localization, convolutional neural networks,↗

PLC-based Impedance Measurement and Current Injection Response Analysis

Studying and mitigating the vulnerabilities of Programmable Logic Controllers (PLCs) to electromagnetic pulse is important for the reliability of the power system. In this paper, an effective impedance measurement scheme is proposed to estimate the susceptibility of PLCs to an electromagnetic pulse. The equivalent non-uniform transmission line model is established to eliminate the impact of the fixture in the de-embedding process. Based on the measured impedance, the equivalent circuit is established to calculate the response of the device when subjected to the electromagnetic pulse. The voltage and current responses of different interfaces are compared utilizing the developed pulse Current Injection (CI) method. Finally, the impedance measurement scheme is verified through testing using three measuring instruments. And the CI simulation experiments reveal the characteristics and susceptibilities of different PLCs interfaces, indicating that some protection measures are required for the reliable operation of PLC.

Qiu, Wei↗

Leveraging Structures in Fault Diagnosis for Lithium-Ion Battery Packs

Lithium-ion battery systems consist of a varying number of single cells, designed to meet specific application requirements for output voltage and capacity. Effective fault diagnosis in these battery systems is an essential prerequisite for ensuring their safe and reliable operation. To address this need, we introduce a novel model-based fault diagnosis approach that distinguishes itself by leveraging informative structures inherent in battery systems such as architecture, uniformity among the constituent cells, and sparsity of fault occurrences to enhance its fault diagnosis capabilities. The proposed approach formulates a moving horizon estimation (MHE) problem, incorporating such structural information to estimate different fault signals—specifically, internal short circuits, external short circuits, and voltage and current sensors faults. We conduct various simulations to evaluate the performance of the proposed approach under different fault types and magnitudes. The obtained results validate the proposed approach and promise effective fault diagnosis for battery systems.

Farakhor, Amir↗

Real-Time Lifetime Prediction of Semiconductor Devices Using Hardware-in-the-Loop

This paper presents a unique approach to enable real-time lifespan prediction of semiconductor power modules using a Hardware-in-the-Loop (HIL) system. By integrating the module's overall loss characteristics-specifically switching and conduction losses-with a thermoelectric model of the thermal management system, this research demonstrates that the model can dynamically estimates the junction temperature profile of the semiconductor devices in response to a changing torque demand profile for the motor drive system. This capability enables continuous monitoring of the module's operational time and cumulative stress induced on the devices to compute accumulated remaining lifetime or time-to-failure (TTF). This study provides an architectural framework for the HIL system with high-fidelity component models of multiple physical domains, allowing simulation of dynamic behaviors of a closely-coupled motor drive system. The advanced real-time computation and measurement functionalities of the HIL system allow for both dynamic lifetime calculations based on simulated data and aggregate lifetime predictions utilizing historical data. Moreover, this paper details an algorithm that not only computes cumulative damage but also synthesizes these data into a comprehensive aggregated lifetime metric. This methodology can enhance the maintenance scheduling strategies and operational reliability of semiconductor devices in critical applications, ultimately extending their service life while optimizing performance.

hardware-in-the-loop (HIL)↗

Isolating Signatures of Cyberattacks under Stressed Grid Conditions

In a controlled cyber-physical network, such as a power grid, any malicious data injection in the sensor measurements can lead to widespread impact due to the actions of the closed-loop controllers. While fast identification of the attack signatures is imperative for reliable operations, it is challenging to do so in a large dynamical network with tightly coupled nodes. A particularly challenging scenario arises when the cyberattacks are strategically launched during a grid stress condition, caused by non-malicious physical disturbances.

Ghosh, Sanchita [BATTELLE (PACIFIC NW LAB)]↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Stability Analysis of Parallel Connected Bidirectional WPT System

This paper presents a stability analysis of parallel-connected bi-directional series-series resonant network wireless power transfer (WPT), optimized for Electric Vehicle (EV) charging and vehicle-to-grid (V2G) applications. The study addresses critical stability challenges in systems integrated with diverse distributed energy resources (DERs), including photovoltaics, fuel cells, wind turbines, energy storage systems, and the AC grid. The stability of such integrated DC grid systems is paramount for ensuring reliable operation, particularly under varying power flow conditions and dynamic interactions between parallel WPT systems. The analysis included system impedance characterization, state-space modeling, and open and closed-loop stability evaluations. The results demonstrated that the integration of a robust control architecture effectively mitigates instability risks and supports scalable, efficient operation. This work underscores the converter's adaptability and its potential for large-scale deployment in wireless EV charging infrastructures and integrated DC grid systems.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

Coupled Electro-Thermal Analysis of Permanent Magnet Synchronous Motor for Electric Vehicles

Permanent magnet synchronous motors (PMSM) are extensively used in electric vehicles. However, high internal heat generation and inefficient heat dissipation often limit the operational reliability, and longevity of the PMSM. Therefore, proper quantification of heat generation in electric motor and advanced embedded motor cooling techniques remain topics of immense interest. In order to accurately predict electro-magnetic performance, i.e., efficiency, component-wise heat losses and the corresponding temperature distribution of a jacket cooled machine, this paper presents a two-way iteratively coupled electro-thermal modeling framework. Finite element based software Motor-CAD has been utilized for electro-magnetic performance calculation of BMW i3 PMSM. Finite volume based computational fluid dynamics/heat transfer (CFD/HT) software ANSYS® FLUENT® has been employed to simulate the temperature distribution of the PMSM, using the electro-magnetic losses as heat input. Computed heat losses, stator, winding, rotor, and magnet temperatures are utilized as coupling parameters between the electro-magnetic and thermal models. A conventional one-way coupling algorithm has also been developed and compared to the newly proposed two-way coupling algorithm. Numerical results confirm that at high current density, one-way coupling algorithm significantly over-predicts the motor temperature compared to the two-way algorithm. A comprehensive analysis has been carried out to characterize the influences of current density, speed, and forced convection heat transfer coefficient on the heat losses, overall efficiency, and maximum temperature of the PMSM. Lastly, an efficiency map has been interpreted from the coupled electro-magnetic simulation.

42 ENGINEERING↗

Analysis of Transformer Magnetizing Reactance Using Describing Function in Direct Power Control of Back-to-Back Modular Multilevel Converter with Advanced Grid Support

This paper presents a Port Controlled Hamiltonian based direct power control architecture for a back-to-back modular multilevel converter system connecting two ac sources at different frequencies. The system features advanced grid support functionalities based on IEEE 1547-2018, implemented on the inverter side. The rectifier side controller ensures reference following for active and/or reactive powers and maintains the commanded dc bus voltage. The inverter side controller ensures power command following for active and reactive powers.The proposed control architecture is designed to suppress second harmonic oscillations in powers during unbalanced grid voltage sags by dynamically adjusting the currents on each ac side. This also ensures effective elimination of any second harmonic oscillations in the equivalent dc bus voltage. Validation is performed on an OPAL-RT real-time platform with case studies on unbalanced and balanced sags, demonstrating the controller's effectiveness during real time implementation. A reduced-scale laboratory prototype further verifies these case studies, with experimental results for balanced sags due to grid simulator limitations. The results confirm the robustness and efficiency of the proposed control strategy in ensuring stable and reliable operation under various grid conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PUF-Based Two-Factor Authentication Protocol for Securing the Power Grid Against Insider Threat

Recent advances in smart grid technologies have enabled additional distributed control paradigms that allow more efficient and reliable operation. However, this creates new security concerns for the grid, such as attackers using spoofed grid control devices to generate false measurements. This paper introduces a two-factor authentication protocol leveraging standard public-key cryptography as one authentication factor and a hardware-based fingerprint, known as a Physical Unclonable Function, as a second authentication factor. This protocol incurs a small overhead and prevents cyber-attacks even when an adversary is able to compromise the cryptographic keys stored in the non-volatile memory of an intelligent control device.

42 ENGINEERING↗