Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROSTATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

SU-D-207A-03: Potential Role of BOLD MRI in Discrimination of Aggressive Tumor Habitat in Prostate Cancer

Purpose: To determine whether blood oxygenation level dependent (BOLD) MRI signal measured in prostate cancer patients, in addition to quantitative diffusion and perfusion parameters from multiparametric (mp)MRI exams, can help discriminate aggressive and/or radioresistant lesions. Methods: Several ongoing clinical trials in our institution require mpMRI exam to determine eligibility (presence of identifiable tumor lesion on mpMRI) and prostate volumes for dose escalation. Upon consent, patients undergo fiducial markers placement and a T2*-weighted imaging at the time of CT sim to facilitate the fusion. In a retrospective analysis eleven clinical trial patients were identified who had undergone mpMRI on GE 3T magnet, followed by T2*-weighted imaging (time-period mean±SD = 48±20 days) using a consistent protocol (gradient echo, TR/TE=30/11.8ms, flip angle=12, matrix=256×256×75, voxel size=1.25×1.25×2.5mm). ROIs for prostate tumor lesions were automatically determined using ADC threshold ≤1200 µm2/s. Although the MR protocol was not intended for BOLD analysis, we utilized the T2*-weighted signal normalized to that in nearby muscle; likewise, T2-weighted lesion signal was normalized to muscle, following rigid registration of the T2 to T2* images. The ratio of these normalized signals, T2*/T2, is a measure of BOLD effect in the prostate tumors. Perfusion parameters (Ktrans, ve, kep) were also calculated. Results: T2*/T2 (mean±SE) was found to be substantially lower for Gleason score (GS) 8&9 (0.82±0.04) compared to GS 7 (1.08±0.07). A k-means cluster analysis of T2*/T2 versus kep = Ktrans/ve revealed two distinct clusters, one with higher T2*/T2 and lower kep, containing only GS 7 lesions, and another with lower T2*/T2 and higher kep, associated with tumor aggressiveness. This latter cluster contained all GS 8&9 lesions, as well as some GS 7. Conclusion: BOLD MRI, in addition to ADC and kep, may play a role (perhaps orthogonal to Gleason score) in identifying prostate lesions that would benefit from more aggressive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-J-101: Stereotactic Body Radiation Therapy Planning for Primary Prostate Cancer with Selective Intraprostatic Boost Determined by 18F-Choline PET/CT

Purpose: To investigate the utility of {sup 18}F-choline positron emission tomography (PET) scans guidance for SBRT dose painting in patients with prostate cancer and its impact on tumor control probability (TCP) and normal tissue complication probability (NTCP). Methods: Twenty seven patients with localized prostate cancer who had {sup 18}F-choline PET/CT scan prior to treatment were included. A pair of nested intraprostatic dominant lesion (IDL) contours (IDL{sub suv60%} and IDL{sub suv70%}) were generated for each patient based on 60% and 70% of maximum prostate uptake on the {sup 18}F-choline PET images. GTV{sub reg} was delineated on prostate according to the gland boundary seen on CT images. The PTVs (PTV{sub suv60%} and PTV{sub suv70%}) were defined as respective IDLs with a 3-mm margin posteriorly and 5 mm in all other dimensions. Two 5-fraction SBRT plans using VMAT technique along with 10 MV FFF beams, plan{sub 36Gy} and plan{sub 50–55Gy}, were generated for each patient. All plans included a dose of 36.25 Gy prescribed to PTV{sub reg}. The Plan{sub 50–55Gy} also included a simultaneous boost dose of 50 Gy and 55 Gy prescribed to the PTV{sub suv60%} and PTV{sub suv70%}, respectively. The utility of {sup 18}F-Choline PET-guided SBRT dose escalation was evaluated by its ability to achieve the prescription dose objectives while adhering to organ-at-risk (OAR) dose constraints. The TCP and NTCP calculated by radiological models were also compared between two plans for each patient. Results: In all 54 SBRT plans generated, the planning objectives and dose constraints were met without exception. Plan{sub 50–55Gy} had a significantly higher dose in PTV{sub suv60%} and PTV{sub suv70%} than those in Plan{sub 36Gy} (p < 0.05), respectively, while still maintaining a safe OAR sparing profile. In addition, plan{sub 50–55Gy} had significantly higher TCP than plan{sub 36Gy}. Conclusion: Using VMAT with FFF beams to incorporate a simultaneous {sup 18}F-choline PET-guided radiation boost dose up to 55 Gy into a SBRT plan is technically feasible. This work was supported in part by Congressionally Directed Medical Research Programs Prostate Cancer Research Program grant PC04130, National Institutes of Health/National Cancer Institute grant R41CA110121, and the UNLV Lincy Endowed Assistant Professorship.

60 APPLIED LIFE SCIENCES↗

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

SU-F-T-15: Evaluation of 192Ir, 60Co and 169Yb Sources for High Dose Rate Prostate Brachytherapy Inverse Planning Using An Interior Point Constraint Generation Algorithm

Purpose: The effectiveness of using a combination of three sources, {sup 60}Co, {sup 192}Ir and {sup 169}Yb, is analyzed. Different combinations are compared against a single {sup 192}Ir source on prostate cancer cases. A novel inverse planning interior point algorithm is developed in-house to generate the treatment plans. Methods: Thirteen prostate cancer patients are separated into two groups: Group A includes eight patients with the prostate as target volume, while group B consists of four patients with a boost nodule inside the prostate that is assigned 150% of the prescription dose. The mean target volume is 35.7±9.3cc and 30.6±8.5cc for groups A and B, respectively. All patients are treated with each source individually, then with paired sources, and finally with all three sources. To compare the results, boost volume V150 and D90, urethra Dmax and D10, and rectum Dmax and V80 are evaluated. For fair comparison, all plans are normalized to a uniform V100=100. Results: Overall, double- and triple-source plans were better than single-source plans. The triple-source plans resulted in an average decrease of 21.7% and 1.5% in urethra Dmax and D10, respectively, and 8.0% and 0.8% in rectum Dmax and V80, respectively, for group A. For group B, boost volume V150 and D90 increased by 4.7% and 3.0%, respectively, while keeping similar dose delivered to the urethra and rectum. {sup 60}Co and {sup 192}Ir produced better plans than their counterparts in the double-source category, whereas {sup 60}Co produced more favorable results than the remaining individual sources. Conclusion: This study demonstrates the potential advantage of using a combination of two or three sources, reflected in dose reduction to organs-at-risk and more conformal dose to the target. three sources, reflected in dose reduction to organs-at-risk and more conformal dose to the target. Our results show that {sup 60}Co, {sup 192}Ir and {sup 169}Yb produce the best plans when used simultaneously and can thus be an alternative to {sup 192}Ir-only in high-dose-rate prostate brachytherapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-378: Evaluation of Dose-Volume Variability and Parameters Between Prostate IMRT and VMAT Plans

Purpose: This study compared the rectal dose-volume consistency, equivalent uniform dose (EUD) and normal tissue complication probability (NTCP) in prostate intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Methods: For forty prostate IMRT and fifty VMAT patients treated using the same dose prescription (78 Gy/39 fraction) and dose-volume criteria in inverse planning optimization, the rectal EUD and NTCP were calculated for each patient. The rectal dose-volume consistency, showing the variability of dose-volume histogram (DVH) among patients, was defined and calculated based on the deviation between the mean and corresponding rectal DVH. Results: From both the prostate IMRT and VMAT plans, the rectal EUD and NTCP were found decreasing with the rectal volume. The decrease rates for the IMRT plans (EUD = 0.47 × 10{sup −3} Gy cm{sup −3} and NTCP = 3.94 × 10{sup −2} % cm{sup −3}) were higher than those for the VMAT (EUD = 0.28 × 10{sup −3} Gy cm{sup −3} and NTCP = 2.61 × 10{sup −2} % cm{sup −3}). In addition, the dependences of the rectal EUD and NTCP on the dose-volume consistency were found very similar between the prostate IMRT and VMAT plans. This shows that both delivery techniques have similar variations of the rectal EUD and NTCP on the dose-volume consistency. Conclusion: Dependences of the dose-volume consistency on the rectal EUD and NTCP were compared between the prostate IMRT and VMAT plans. It is concluded that both rectal EUD and NTCP decreased with an increase of the rectal volume. The variation rates of the rectal EUD and NTCP on the rectal volume were higher for the IMRT plans than VMAT. However, variations of the rectal dose-volume consistency on the rectal EUD and NTCP were found not significant for both delivery techniques.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-13: Continuous Intra-Fractional Monitoring of the Prostate Using Dynamic KV Collimation and Tube Current Modulation

Purpose: The focus of this work is to improve the available kV image quality for continuous intra-fraction monitoring of the prostate. This is investigated using a novel blade collimation system enabling modulated volume-of-interest (VOI) imaging of prostate fiducial markers. Methods: A four-blade dynamic kV collimator was used to track a VOI during gantry rotation. Planar image quality was investigated as a function of collimator dimension, while maintaining the same dose to isocenter, for a 22.2 cm diameter cylindrical water phantom with a 9 mm diameter bone insert. A sample prostate anatomy was defined in the planning system, including three fiducial markers within the CTV. The VOI margin around each marker was set to be 2σ of the population covariance matrix characterizing prostate motion. DRRs were used to calculate the kV attenuation for each VOI as a function of angle. The optimal marker and tube current were determined using kV attenuation. Monte Carlo simulations were used to calculate the imaging dose to the phantom and MV scatter dose to the imaging panel. Results: Preliminary measurements show an increase in CNR by a factor of 1.3 with the VOI method, when decreasing from an 6×6 to 2×2 cm{sup 2} field. Attenuation calculations show a change in kV fluence at the detector by a factor of 21.6 with fiducial optimization; resultant tube current modulation increases maximum dose by a factor of 1.4 compared to no modulation. MV scatter contribution to the kV detector changes by approximately a factor of two over a complete gantry rotation. Conclusion: The dynamic collimation system allows single fiducial marker tracking at a very low dose, with reduction of scatter and improvement of image quality, compared to imaging the entire prostate. The approach is compatible with tube current modulation, which enables consistent image quality throughout the range of gantry rotation. This project was funded by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-03: A Computational Methodology for Determination of CTV-To-PTV Margins with Inter Fractional Shape Variations Based On a Statistical Point Distribution Model for Prostate Cancer Radiation Therapy

Purpose: Our assumption was that interfractional shape variations of target volumes could not be negligible for determination of clinical target volume (CTV)-to-planning target volume (PTV) margins. The aim of this study was to investigate this assumption as a simulation study by developing a computational framework of CTV-to-PTV margins with taking the interfractional shape variations into account based on point distribution model (PDM) Methods: The systematic and random errors for interfractional shape variations and translations of target volumes were evaluated for four types of CTV regions (only a prostate, a prostate plus proximal 1-cm seminal vesicles, a prostate plus proximal 2-cm seminal vesicles, and a prostate plus whole seminal vesicles). The CTV regions were delineated depending on prostate cancer risk groups on planning computed tomography (CT) and cone beam CT (CBCT) images of 73 fractions of 10 patients. The random and systematic errors for shape variations of CTV regions were derived from PDMs of CTV surfaces for all fractions of each patient. Systematic errors of shape variations of CTV regions were derived by comparing PDMs between planning CTV surfaces and average CTV surfaces. Finally, anisotropic CTV-to-PTV margins with shape variations in 6 directions (anterior, posterior, superior, inferior, right, and left) were computed by using a van Herk margin formula. Results: Differences between CTV-to-PTV margins with and without shape variations ranged from 0.7 to 1.7 mm in anterior direction, 1.0 to 2.8 mm in posterior direction, 0.8 to 2.8 mm in superior direction, 0.6 to 1.6 mm in inferior direction, 1.4 to 4.4 mm in right direction, and 1.3 to 5.2 mm in left direction. Conclusion: More than 1.0 mm additional margins were needed at least in 3 directions to guarantee CTV coverage due to shape variations. Therefore, shape variations should be taken into account for the determination of CTV-to-PTV margins.

60 APPLIED LIFE SCIENCES↗

Quantification of mutant SPOP proteins in prostate cancer using mass spectrometry-based targeted proteomics

Speckle-type POZ protein (SPOP) is an E3 ubiquitin ligase adaptor protein that functions as a potential tumor suppressor, and SPOP mutations have been identified in ~10% of human prostate cancers. However, it remains unclear if mutant SPOP proteins can be utilized as biomarkers for early detection, diagnosis, prognosis or targeted therapy of prostate cancer. Moreover, the SPOP mutation sites are distributed in a relatively short region where multiple lysine residues, posing significant challenges for bottom-up proteomics analysis of the SPOP mutations. To address this issue, PRISM (high-pressure, high-resolution separations coupled with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometry assays have been developed for quantifying wild-type SPOP protein and 11 prostate cancer-derived SPOP mutations. Despite inherent limitations due to amino acid sequence constraints, all the PRISM-SRM assays developed using Arg-C digestion showed a linear dynamic range of at least two orders of magnitude, with limits of quantification range from 0.1 to 1 fmol/μg of total protein in the cell lysate. Applying these SRM assays to analyze HEK293T cells with and without expression of the three most frequent SPOP mutations in prostate cancer (Y87N, F102C or F133V) led to confident detection of all three SPOP mutations in corresponding positive cell lines but not in the negative cell lines. Expression of the F133V mutation and wild-type SPOP was at much lower levels compared to that of F102C and Y87N mutations; however, at present it is unknown if this also affects the activity of the SPOP protein. In summary, PRISM-SRM enables multiplexed, isoform-specific detection of mutant SPOP proteins in cell lysates, which holds great potential in biomarker development for prostate cancer.

59 BASIC BIOLOGICAL SCIENCES↗

Extremely Early Diagnostic Test for Prostate Cancer

This article reports the results of a blinded fiber diffraction study of skin samples taken from TRAMP mice and age-matched controls to determine whether changes noted in fiber diffraction studies of human skin were present in these TRAMP mice studies. These mice are bred to progress to Gleeson Type 3 to Type 5 prostate cancer. Small strips, 1 mm x 5 mm, cut from the mouse skin samples were loaded into cells in the same way as human samples and slightly stretched to remove the crimp. They remained fully hydrated throughout exposure to the synchrotron beam. The added change that was reported for prostate cancer in 2009 was obtained for all TRAMP mice samples, indicating that this change can be read as High Grade Cancer in human diagnostic tests. These changes were evident for all 3 and 7 week old TRAMP mice samples but not for any of the control samples. This indicates that the changes in the fibre diffraction patterns appear much earlier than in any other available prostate cancer diagnostic test, as none of these can verify the presence of prostate cancer in the TRAMP mice before 10 weeks of age. The fiber diffraction test is therefore the most accurate and earliest test for high grade prostate cancer.

59 BASIC BIOLOGICAL SCIENCES↗

Intrafractional Motion of the Prostate During Hypofractionated Radiotherapy

Purpose: To report the characteristics of prostate motion as tracked by the stereoscopic X-ray images of the implanted fiducials during hypofractionated radiotherapy with CyberKnife. Methods and Materials: Twenty-one patients with prostate cancer who were treated with CyberKnife between January 2005 and September 2007 were selected for this retrospective study. The CyberKnife uses a stereoscopic X-ray system to obtain the position of the prostate target through the monitoring of implanted gold fiducial markers. If there is a significant deviation, the treatment is paused while the patient is repositioned by moving the couch. The deviations calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. Results: Included in the analysis were 427 data sets and 4,439 time stamps of X-ray images. The mean duration for each data set was 697 sec. At 30 sec, a motion >2 mm exists in about 5% of data sets. The percentage is increased to 8%, 11%, and 14% at 60 sec, 90 sec, and 120 sec, respectively. A similar trend exists for other values of prostate motion. Conclusions: With proper monitoring and intervention during treatment, the prostate shifts observed among patients can be kept within the tracking range of the CyberKnife. On average, a sampling rate of {approx}40 sec between consecutive X-rays is acceptable to ensure submillimeter tracking. However, there is significant movement variation among patients, and a higher sampling rate may be necessary in some patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of two different radioactive sources for prostate brachytherapy treatment

In this study we evaluated two radioactive sources for brachytherapy treatments. Our main goal was to quantify the absorbed doses on organs and tissues of an adult male patient, submitted to a brachytherapy treatment with two radioactive sources. We evaluated a {sup 192}Ir and a {sup 125}I radioactive sources. The {sup 192}Ir radioactive source is a cylinder with 0.09 cm in diameter and 0.415 cm long. The {sup 125}I radioactive source is also a cylinder, with 0.08 cm in diameter and 0.45 cm long. To evaluate the absorbed dose distribution on the prostate, and other organs and tissues of an adult man, a male virtual anthropomorphic phantom MASH, coupled in the radiation transport code MCNPX 2.7.0, was employed.We simulated 75, 90 and 102 radioactive sources of {sup 125}I and one of {sup 192}Ir, inside the prostate, as normally used in these treatments, and each treatment was simulated separately. As this phantom was developed in a supine position, the displacement of the internal organs of the chest, compression of the lungs and reduction of the sagittal diameter were all taken into account. For the {sup 192}Ir, the higher doses values were obtained for the prostate and surrounding organs, as the colon, gonads and bladder. Considering the {sup 125}I sources, with photons with lower energies, the doses to organs that are far from the prostate were lower. All values for the dose rates are in agreement with those recommended for brachytherapy treatments. Besides that, the new seeds evaluated in this work present usefulness as a new tool in prostate brachytherapy treatments, and the methodology employed in this work may be applied for other radiation sources, or treatments. (authors)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

False positive PSMA PET for tumor remnants in the irradiated prostate and other interpretation pitfalls in a prospective multi-center trial

Readers need to be informed about potential pitfalls of [ 68 Ga]Ga-PSMA-11 PET interpretation. Here we report [ 68 Ga]Ga-PSMA-11 PET findings discordant with the histopathology/composite reference standard in a recently published prospective trial on 635 patients with biochemically recurrent prostate cancer. Consensus reads were false positive in 20 regions of 17/217 (8%) patients with lesion validation. Majority of the false positive interpretations (13 of 20, 65%) occurred in the context of suspected prostate (bed) relapse (T) after radiotherapy ( n = 11); other false positive findings were noted for prostate bed post prostatectomy (T, n = 2), pelvic nodes (N, n = 2), or extra pelvic lesions (M, n = 5). Major sources of false positive findings were PSMA-expressing residual adenocarcinoma with marked post-radiotherapy treatment effect. False negative interpretation occurred in 8 regions of 6/79 (8%) patients with histopathology validation, including prostate (bed) ( n = 5), pelvic nodes ( n = 1), and extra pelvic lesions ( n = 2). Lesions were missed mostly due to small metastases or adjacent bladder/urine uptake.[ 68 Ga]Ga-PSMA-11 PET at biochemical recurrence resulted in less than 10% false positive interpretations. Post-radiotherapy prostate uptake was a major source of [ 68 Ga]Ga-PSMA-11 PET false positivity. In few cases, PET correctly detects residual PSMA expression post-radiotherapy, originating however from treated, benign tissue or potentially indolent tumor remnants.

Radiology, Nuclear Medicine & Medical Imaging↗

Enzalutamide response in a panel of prostate cancer cell lines reveals a role for glucocorticoid receptor in enzalutamide resistant disease

Representative in vitro model systems that accurately model response to therapy and allow the identification of new targets are important for improving our treatment of prostate cancer. Here we describe molecular characterization and drug testing in a panel of 20 prostate cancer cell lines. The cell lines cluster into distinct subsets based on RNA expression, which is largely driven by functional Androgen Receptor (AR) expression. KLK3 , the AR-responsive gene that encodes prostate specific antigen, shows the greatest variability in expression across the cell line panel. Other common prostate cancer associated genes such as TMPRSS2 and ERG show similar expression patterns. Copy number analysis demonstrates that many of the most commonly gained (including regions containing TERC and MYC ) and lost regions (including regions containing TP53 and PTEN) that were identified in patient samples by the TCGA are mirrored in the prostate cancer cell lines. Assessment of response to the anti-androgen enzalutamide shows a distinct separation of responders and non-responders, predominantly related to status of wild-type AR. Surprisingly, several AR-null lines responded to enzalutamide. These AR-null, enzalutamide-responsive cells were characterized by high levels of expression of glucocorticoid receptor (GR) encoded by NR3C1 . Treatment of these cells with the anti-GR agent mifepristone showed that they were more sensitive to this drug than enzalutamide, as were several of the enzalutamide non-responsive lines. This is consistent with several recent reports that suggest that GR expression is an alternative signaling mechanism that can bypass AR blockade. This study reinforces the utility of large cell line panels for the study of cancer and identifies several cell lines that represent ideal models to study AR-null cells that have upregulated GR to sustain growth.

59 BASIC BIOLOGICAL SCIENCES↗

Laminin receptor specific therapeutic gold nanoparticles (198AuNP-EGCg) show efficacy in treating prostate cancer

Systemic delivery of therapeutic agents to solid tumors is hindered by vascular and interstitial barriers. We hypothesized that prostate tumor specific epigallocatechingallate( EGCg) functionalized radioactive gold nanoparticles, when delivered intratumorally (IT), will circumvent transport barriers, resulting in targeted delivery of therapeutic payloads. The results described herein provide unequivocal validation of our hypothesis. We report the development of inherently therapeutic gold nanoparticles derived from Au-198 isotope; the range of 198Au β-particle ( ~ 11 mm in tissue or ~1100 cell diameters) is sufficiently long to provide cross-fire effects of radiation dose delivered to cells within the prostate gland and short enough to minimize radiation dose to critical tissues near the periphery of the capsule. The formulation of biocompatible 198AuNPs utilizes the redox chemistry of prostate tumor specific phytochemical EGCg as it converts gold salt into gold nanoparticles and also selectively binds with excellent affinity to Laminin67R receptors which are over expressed in prostate tumor cells. Pharmacokinetic studies in PC-3 xenograft SCID mice showed ~72% retention of 198AuNP-EGCg in tumors 24 h after intratumoral administration. Therapeutic studies showed 80% reduction of tumor volumes after 28 days demonstrating significant inhibition of tumor growth compared to controls. This innovative “green nanotechnological“approach serves as a basis for designing target specific antineoplastic agents. This novel intratumorally injectable 198AuNP-EGCg nanotherapeutic agent may provide significant advances in oncology for use as an effective treatment for prostate and other solid tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiplexed targeted mass spectrometry assays for prostate cancer-associated urinary proteins

Biomarkers for effective early diagnosis and prognosis of prostate cancer are still lacking. Multiplexed assays for cancer-associated proteins could be useful for identifying biomarkers for cancer detection and stratification. Herein, we report the development of sensitive targeted mass spectrometry assays for simultaneous quantification of 10 prostate cancer-associated proteins in urine. The diagnostic utility of these markers was evaluated with an initial cohort of 20 clinical urine samples. Individual marker concentration was normalized against the measured urinary prostate-specific antigen level as a reference of prostate-specific secretion. The areas under the receiver-operating characteristic curves for the 10 proteins ranged from 0.75 for CXCL14 to 0.87 for CEACAM5. Furthermore, MMP9 level was found to be significantly higher in patients with high Gleason scores, suggesting a potential of MMP9 as a marker for risk level assessment. Taken together, our work illustrated the feasibility of accurate multiplexed measurements of low-abundance cancer-associated proteins in urine and provided a viable path forward for preclinical verification of candidate biomarkers for prostate cancer.

Environmental Molecular Sciences Laboratory↗

Further Developments in Microwave Ablation of Prostate Cells

A report presents additional information about the subject matter of Microwave Treatment of Prostate Cancer and Hyperplasia (MSC-23049), NASA Tech Briefs, Vol. 29, No. 6 (June 2005), page 62. To recapitulate: the basic idea is to use microwaves to heat and thereby kill small volumes of unhealthy prostate tissue. The prostate is irradiated with microwaves from one or more antennas positioned near the prostate by means of catheters inserted in the urethra and/or colon. The microwave frequency, power, and exposure time, phasing, positions, and orientations of the antennas may be chosen to obtain the desired temperature rise in the heated region and to ensure that the location and extent of the heated region coincides with the region to be treated to within a few millimeters. Going beyond the description in the cited previous article, the report includes a diagram that illustrates typical placement of urethra and colon antenna catheters and presents results of computationally simulated prostate-heating profiles for several different combinations of antenna arrangements, frequencies, and delivered- energy levels as well as experimental results within phantom materials. The advantage of the two-antenna technology is that the heat generated at each antenna is significantly reduced from that associated with only one antenna. The microwave energy radiated from each antenna is focused at the tumor center by adjusting the phasing of the irradiated microwave signal from the antennas.

Arndt, G. Dickey↗

Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

Majewski, Stanislaw↗

Applications of immunoPET: Using 124 I-anti-PSCA A11 minibody for imaging disease progression and response to therapy in mouse xenograft models of prostate cancer

Here, prostate stem cell antigen (PSCA) is highly expressed in local prostate cancers and prostate cancer bone metastases and its expression correlates with androgen receptor activation and a poor prognosis. Here in this study, we investigate the potential clinical applications of immunoPET with the anti-PSCA A11 minibody, an antibody fragment optimized for use as an imaging agent. We compare A11 minibody immunoPET to 18 F-Fluoride PET bone scans for detecting prostate cancer bone tumors and evaluate the ability of the A11 minibody to image tumor response to androgen deprivation. Osteoblastic, PSCA expressing, LAPC-9 intratibial xenografts were imaged with serial 124 I-anti-PSCA A11 minibody immunoPET and 18 F-Fluoride bone scans. Mice bearing LAPC-9 subcutaneous xenografts were treated with either vehicle or MDV-3100 and imaged with A11 minibody immunoPET/CT scans pre- and post-treatment. Ex vivo flow cytometry measured the change in PSCA expression in response to androgen deprivation. A11 minibody demonstrated improved sensitivity and specificity over 18 F-Fluoride bone scans for detecting LAPC-9 intratibial xenografts at all time points. Finally, LAPC-9 subcutaneous xenografts showed downregulation of PSCA when treated with MDV-3100 which A11 minibody immunoPET was able to detect in vivo .

62 RADIOLOGY AND NUCLEAR MEDICINE↗