Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Quantum limited particle sensing in optical tweezers

Particle sensing in optical tweezers systems provides information on the position, velocity, and force of the specimen particles. The conventional quadrant detection scheme is applied ubiquitously in optical tweezers experiments to quantify these parameters. In this paper, we show that quadrant detection is nonoptimal for particle sensing in optical tweezers and propose an alternative optimal particle sensing scheme based on spatial homodyne detection. A formalism for particle sensing in terms of transverse spatial modes is developed and numerical simulations of the efficacies of both quadrant and spatial homodyne detection are shown. We demonstrate that 1 order of magnitude improvement in particle sensing sensitivity can be achieved using spatial homodyne over quadrant detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for acoustic signals from ultrahigh energy neutrinos in 1500 km{sup 3} of sea water

An underwater acoustic sensor array spanning {approx}1500 km{sup 3} is used to search for cosmic-ray neutrinos of ultrahigh energies ( E{sub {nu}>}10{sup 18} eV). Approximately 328 million triggers accumulated over an integrated 130 days of data taking are analyzed. The sensitivity of the experiment is determined from a Monte Carlo simulation of the array using recorded noise conditions and expected waveforms. Two events are found to have properties compatible with showers in the energy range 10{sup 24} eV<E{sub sh}<5x10{sup 24} eV and 10{sup 22} eV<E{sub sh}<5x10{sup 22} eV. Since the understanding of impulsive backgrounds is limited, a flux upper limit is set providing the most sensitive limit on ultrahigh energy neutrinos using the acoustic technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Parameterization of Top-Hat Particle Sensors with Microchannel-Plate-Based Detection Systems and its Application to the Fast Plasma Investigation on NASA's Magnetospheric MultiScale Mission

The most common instrument for low energy plasmas consists of a top-hat electrostatic analyzer geometry coupled with a microchannel-plate (MCP)-based detection system. While the electrostatic optics for such sensors are readily simulated and parameterized during the laboratory calibration process, the detection system is often less well characterized. Furthermore, due to finite resources, for large sensor suites such as the Fast Plasma Investigation (FPI) on NASA's Magnetospheric Multiscale (MMS) mission, calibration data are increasingly sparse. Measurements must be interpolated and extrapolated to understand instrument behavior for untestable operating modes and yet sensor inter-calibration is critical to mission success. To characterize instruments from a minimal set of parameters we have developed the first comprehensive mathematical description of both sensor electrostatic optics and particle detection systems. We include effects of MCP efficiency, gain, scattering, capacitive crosstalk, and charge cloud spreading at the detector output. Our parameterization enables the interpolation and extrapolation of instrument response to all relevant particle energies, detector high voltage settings, and polar angles from a small set of calibration data. We apply this model to the 32 sensor heads in the Dual Electron Sensor (DES) and 32 sensor heads in the Dual Ion Sensor (DIS) instruments on the 4 MMS observatories and use least squares fitting of calibration data to extract all key instrument parameters. Parameters that will evolve in flight, namely MCP gain, will be determined daily through application of this model to specifically tailored in-flight calibration activities, providing a robust characterization of sensor suite performance throughout mission lifetime. Beyond FPI, our model provides a valuable framework for the simulation and evaluation of future detection system designs and can be used to maximize instrument understanding with minimal calibration resources.

Instrument-model↗

Ground-based observations of thunderstorm-correlated fluxes of high-energy electrons, gamma rays, and neutrons

The Aragats Space Environmental Center facilities continuously measure fluxes of neutral and charged secondary cosmic ray incidents on the Earth's surface. Since 2003 in the 1-minute time series we have detected more than 100 enhancements in the electron, gamma ray, and neutron fluxes correlated with thunderstorm activities. During the periods of the count rate enhancements, lasting tens of minutes, millions of additional particles were detected. Based on the largest particle event of September 19, 2009, we show that our measurements support the existence of long-lasting particle multiplication and acceleration mechanisms in the thunderstorm atmosphere. For the first time we present the energy spectra of electrons and gamma rays from the particle avalanches produced in the thunderstorm atmosphere, reaching the Earth's surface.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Challenges in the detection of long lived particles: the Hidden Valley Scenario

Neutral particles with long decay paths and many particles in the final state represent, from an experimental point of view, a challenge both for the trigger and for the reconstruction capabilities of the ATLAS detector. The Hidden Valley scenario is an excellent framework to explore the challenges posed by long-lived neutral particles. In this paper we present strategies to select such events, in particular for the Higgs boson decays, with special attention to trigger level problems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Image plate multi-scan response to fusion protons in the range of 1–14 MeV

Image plates (IPs) are a quickly recoverable and reusable radiation detector often used to measure proton and x-ray fluence in laser-driven experiments. Recently, IPs have been used in a proton radiography detector stack on the OMEGA laser, a diagnostic historically implemented with CR-39, or radiochromic film. The IPs used in this and other diagnostics detect charged particles, neutrons, and x-rays indiscriminately. IPs detect radiation using a photo-stimulated luminescence (PSL) material, often phosphor, in which electrons are excited to metastable states by ionizing radiation. Protons at MeV energies deposit energy deeper into the IP compared with x rays below ∼20 keV due to the Bragg peak present for protons. This property is exploited to discriminate between radiation types. Doses of mono-energetic protons between 1.7 and 14 MeV are applied to IPs using the MIT linear electrostatic ion accelerator. This paper presents the results from consecutive scans of IPs irradiated with different proton energies. The PSL ratios between subsequent scans are shown to depend on proton energy, with higher energy protons having lower PSL ratios for each scan. This finding is separate from the known energy dependence in the absolute sensitivity of IPs. The results can be compared to complimentary work on x rays, showing a difference between protons and x rays, forging a path to discriminate between proton and x-ray fluence in mixed radiation environments.

Instruments & Instrumentation↗

Neutrino-nucleus cross section impacts on neutrino oscillation measurements

The challenges in neutrino-nucleus cross section modeling and its impact on neutrino oscillation experiments are widely recognized. However, a comprehensive and theoretically robust estimation of cross section uncertainties has been lacking, and few studies have quantitatively examined their impact on oscillation measurements. In this work, we evaluate the effect of cross section uncertainties on oscillation parameters using setups inspired by NOvA and DUNE. To characterize these uncertainties, we adopt multiple neutrino-nucleus event generators and simulate a realistic experimental procedure that incorporates near-detector data and near-to-far-detector extrapolation. Our results confirm that cross section uncertainties cannot significantly bias oscillation results in current statistics-dominated experiments like NOvA. However, they could lead to substantial bias for future systematics-dominated experiments like DUNE, even when near-detector data are employed to mitigate uncertainties. These findings underscore the need for further studies on the quantitative impacts of cross section modeling, improved strategies to utilize near-detector data and the PRISM concept, and more robust cross section models to optimize the success of future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A drift detector system with anode and cathode readout in the GlueX experiment

A drift detector system designed to detect charged particle tracks in the GlueX experiment dedicated to study the nature of confinement is described. The key design features of the drift chambers associated with the requirement of a minimum material budget in the path of secondary particles are presented. The spatial resolution and the detection efficiency have been measured with cosmic rays using the automatic data acquisition system.

Berdnikov, V V↗

Detection of asteroidal dust particles from known families in near-Earth orbits

The orbital evolution of dust particles with two different sizes (diameters equal to 4 and 9 microns) originating from the Eos, Koronis, and Themis asteroidal families was studied. All the planetary perturbations, radiation pressure, Poynting-Robertson light drag, and corpuscular solar wind effects are included in the calculation. It is concluded that for particles having diameters ranging from 4 to 9 microns, Eos particles are quite different in orbital elements from Themis and Koronis particles. For Koronis and Themis particles, the best times to collect them are around April and October.

Dermott, Stanley F.↗

Heterogeneous Point Set Transformers for Segmentation of Multiple View Particle Detectors

NOvA is a long-baseline neutrino oscillation experiment that detects neutrino particles from the NuMI beam at Fermilab. Before data from this experiment can be used in analyses, raw hits in the detector must be matched to their source particles, and the type of each particle must be identified. This task has commonly been done using a mix of traditional clustering approaches and convolutional neural networks (CNNs). Due to the construction of the detector, the data is presented as two sparse 2D images: an XZ and a YZ view of the detector, rather than a 3D representation. We propose a point set neural network that operates on the sparse matrices with an operation that mixes information from both views. Our model uses less than 10% of the memory required using previous methods while achieving a 96.8% AUC score, a higher score than obtained when both views are processed independently (85.4%).

Robles, Edgar E. [UC, Irvine (main)]↗