Search NASA⌕ Search

SEARCH · Search NASA

Results for “Persistent Availability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

583 records · Page 33

Cavity contour segmentation in chest radiographs using supervised learning and dynamic programming

Purpose: Efficacy of tuberculosis (TB) treatment is often monitored using chest radiography. Monitoring size of cavities in pulmonary tuberculosis is important as the size predicts severity of the disease and its persistence under therapy predicts relapse. The authors present a method for automatic cavity segmentation in chest radiographs. Methods: A two stage method is proposed to segment the cavity borders, given a user defined seed point close to the center of the cavity. First, a supervised learning approach is employed to train a pixel classifier using texture and radial features to identify the border pixels of the cavity. A likelihood value of belonging to the cavity border is assigned to each pixel by the classifier. The authors experimented with four different classifiers:k-nearest neighbor (kNN), linear discriminant analysis (LDA), GentleBoost (GB), and random forest (RF). Next, the constructed likelihood map was used as an input cost image in the polar transformed image space for dynamic programming to trace the optimal maximum cost path. This constructed path corresponds to the segmented cavity contour in image space. Results: The method was evaluated on 100 chest radiographs (CXRs) containing 126 cavities. The reference segmentation was manually delineated by an experienced chest radiologist. An independent observer (a chest radiologist) also delineated all cavities to estimate interobserver variability. Jaccard overlap measure Ω was computed between the reference segmentation and the automatic segmentation; and between the reference segmentation and the independent observer's segmentation for all cavities. A median overlap Ω of 0.81 (0.76 ± 0.16), and 0.85 (0.82 ± 0.11) was achieved between the reference segmentation and the automatic segmentation, and between the segmentations by the two radiologists, respectively. The best reported mean contour distance and Hausdorff distance between the reference and the automatic segmentation were, respectively, 2.48 ± 2.19 and 8.32 ± 5.66 mm, whereas these distances were 1.66 ± 1.29 and 5.75 ± 4.88 mm between the segmentations by the reference reader and the independent observer, respectively. The automatic segmentations were also visually assessed by two trained CXR readers as “excellent,” “adequate,” or “insufficient.” The readers had good agreement in assessing the cavity outlines and 84% of the segmentations were rated as “excellent” or “adequate” by both readers. Conclusions: The proposed cavity segmentation technique produced results with a good degree of overlap with manual expert segmentations. The evaluation measures demonstrated that the results approached the results of the experienced chest radiologists, in terms of overlap measure and contour distance measures. Automatic cavity segmentation can be employed in TB clinics for treatment monitoring, especially in resource limited settings where radiologists are not available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of electron beam technology to decompose persistent emerging drinking water contaminants: poly- and perfluoroalkyl substances (PFAS) and 1,4-Dioxane

Poly- and perfluoroalkyl substances (PFAS) and 1,4-dioxane are persistent emerging contaminants that are currently under consideration for federal and state-specific regulations in drinking water. Both PFAS and 1,4-dioxane are highly resistant to degradation and are not effectively removed by conventional drinking water treatment systems. Results from the Unregulated Contaminant Monitoring Rule 3 survey showed that >540 sites across the nation are contaminated with both PFAS and 1,4-dioxane. Hence, there is a need to identify technologies that can effectively remove both these contaminants. Water treatment via electron beam (e-beam) has been proven effective at treating a wide range of contaminants, including perfluorooctane sulfonate (PFOS), perfluorooctanoate (PFOA), polychlorinated biphenyls, and trichloroethylene. While the e-beam process is often considered similar to advanced oxidation processes (AOPs), e-beam technology is unique in that it produces both highly oxidizing and reducing species at the same time. The specific objectives of this study were to: (i) determine the effectiveness of 9 MeV electrons provided by the Fermilab’s Accelerator Application Development and Demonstration (A2D2) tool to decompose PFAS and 1,4-dioxane; (ii) assess the formation of byproducts during water treatment; (iii) apply the optimized treatment to field groundwater samples contaminated with PFAS and 1,4-dioxane, and (iv) assess the energy demands for the treatment of these contaminants using e-beam. Results from this study showed that e-beam is effective in treating both 1,4-dioxane and PFAS. Complete degradation of 1,4-dioxane was observed at a dose of 5 kGy for an initial concentration of up to 1 ppm without the need for any sample modification. The electrical energy per order (EEo) for treatment of 1,4-dioxane ranged from 0.46 to 0.72 kWh/m 3 /order and was comparable and even lower, in some cases, than other AOP technologies. Alkaline conditions (pH 13) and low dissolved oxygen concentration (2 mg/L) highly favored the treatment of PFAS by e-beam. Greater than 90% removal of PFOA and PFOS from an initial concentration of 100 to 500 ppb was achieved at a dose of 250 kGy and 500 kGy, respectively, under optimized conditions. The degradation efficiency was not significantly changed when treating other PFAS of fluorinated carbon chain length of 5 to 7 individually at 250 kGy with a removal ranging from 85¬–99% for different compounds. Short chain PFAS (perfluorobutanoate: PFBA and perfluorobutane sulfonate: PFBS) did not degrade under the same conditions at 250 kGy, but 70 to 99% degradation was observed at a higher dose of 1000 kGy. Short chain PFAS (perfluorohexanoate: PFHxA (C5) and perfluoroheptanoate: PFHpA (C6)) were detected after treatment of PFOA, but not after PFOS treatment. Inability to close the mass balance through targeted analysis suggests the presence of other intermediates not detectable by available analytical methods. When treating PFAS mixture containing ten compounds at equimolar concentration of 0.05 µM each, preferential degradation of polyfluorinated compound (6:2 fluorotelomer sulfonate or 6:2 FTS) followed by C8 and C7 compounds was observed as a function of increasing e-beam dose. About 30% degradation of ΣPFAS was observed at 250 kGy and no further removal was observed up to a dose of 1000 kGy. C4 to C6 PFASs showed no degradation, while C3 PFAS (PFBS) showed an increase in concentration by 34% at 1000 kGy due to formation from the breakdown of other long chain PFAS. These results suggested that (a) the reaction kinetics is likely different for different PFAS based on chain length, functional group, and the degree of fluorination of the carbon chain, and (b) there may be intermediates generated from the degradation of 6:2 FTS and C7/C8 compounds that can potentially scavenge hydrated electrons needed for reaction with the untreated PFAS molecules. Treatment of three PFAS-contaminated groundwater samples from two US states showed similar trends as observed in the treatment of equimolar PFAS mixtures. Up to 71% removal of ΣPFAS was achieved in real groundwater samples at 750 kGy and data trend suggested that higher degradation is feasible if higher doses (>1MGy) are applied to treat field samples to overcome matrix effects and competing species. Calculated EEo for PFAS ranged from as low as ~48 to 1081 kWh/m 3 /order depending on the type of PFAS treated. These values are comparable and even lower, in some cases, than other destructive technologies employed for PFAS treatment such as ultrasound, plasma, and photochemical treatment. The results from this study indicate e-beam is a promising approach under favorable conditions and should be explored further as an end-of-train treatment option for PFAS destruction.

1,4-Dioxane↗

Metal Bioavailability and Ecotoxicity of Bioremediated Oils and Tailings by BioTiger{sup TM}, a Microbial Consortium

Oil Sands and Mature Fine Tailings: Oil sand reserves are a major source of oil for the United States. Oil sands are a mixture of sand, clay, water, and bitumen. The refining process requires large volumes of water and generates hazardous Mature Fine Tailings (MFTs) that are stored in engineered settling ponds. They are of major environmental concern due to their persistence and difficulty to naturally biodegrade. MFT Contaminants of Concern: Naphthenic Acids (NAs), Polycyclic Aromatic Hydrocarbons (PAHs), Benzene, Toluene, Ethylbenzene and Xylene (BTEX), Metals, Residual Bitumen. BioTiger{sup TM} (BT{sup TM}), the SRNL patented 12 component microbial consortia was found to cometabolically degrade some NAs and PAHs. Previous studies performing short term exposure (48 hours and 7 days) to BT{sup TM} have resulted in increased toxicity due to the partial degradation of PAHs forming toxic intermediates. Objective: Evaluate the ecotoxicity of BT{sup TM} remediated MFTs exposed to a 2 week period w/ yeast (Y) extract. This work will determine BT{sup TM}'s remediation of MFTs from Fort McMurray, Alberta. Acute toxicity tests will be performed under section 9 of EPA's Method for Measuring Acute Toxicity using the freshwater organism, Ceriodaphnia dubia. Monitor BT{sup TM} growth through Most Probable Number (MPN) counts, pH, and metal bioavailability will also be evaluated. Preparing tailing solutions for biodegradation: BT{sup TM} components were grown in R2A media and combined. Mother BT{sup TM} was centrifuged at 7000 rpm for 20 minutes and resuspended in Bushnell Haus. 33 g of tailings were added to 1100 mL Bushnell Haus along with yeast extract (11 g) to create a 3% tailing solution. Treatments were performed in triplicate. Preparing solutions for toxicity tests using C. dubia: Supernatant was collected immediately after centrifuging at 7000 rpm for 20 min. Supernatant was filtered via a 0.22 μm sterile system. All treatments except MFT, Y peaked at T=4. This decrease in microbial growth could be associated with toxicity from intermediate byproducts. Treatments containing only MFTs decreased in the initial 11 days before growing significantly. Final solution for MFT, Y treatment had the highest pH. This could potentially be due to increased microbial activity linked with yeast consumption. All treatments except MFT, Y peaked at T=4. This decrease in microbial growth could be associated with toxicity from intermediate byproducts. Treatments containing only MFTs decreased in the initial 11 days before growing significantly. Future Direction: Await results from Acute Toxicity Tests and Metal Bioavailability Quantification of biosurfactant production. Evaluate hydrocarbon degradation byproducts using an analytical chemistry approach. More toxicity experiments with variations in time and conditions.

54 ENVIRONMENTAL SCIENCES↗

Coastal Ohio Wind Project

The Coastal Ohio Wind Project intends to address problems that impede deployment of wind turbines in the coastal and offshore regions of Northern Ohio. The project evaluates different wind turbine designs and the potential impact of offshore turbines on migratory and resident birds by developing multidisciplinary research, which involves wildlife biology, electrical and mechanical engineering, and geospatial science. Firstly, the project conducts cost and performance studies of two- and three-blade wind turbines using a turbine design suited for the Great Lakes. The numerical studies comprised an analysis and evaluation of the annual energy production of two- and three-blade wind turbines to determine the levelized cost of energy. This task also involved wind tunnel studies of model wind turbines to quantify the wake flow field of upwind and downwind wind turbine-tower arrangements. The experimental work included a study of a scaled model of an offshore wind turbine platform in a water tunnel. The levelized cost of energy work consisted of the development and application of a cost model to predict the cost of energy produced by a wind turbine system placed offshore. The analysis found that a floating two-blade wind turbine presents the most cost effective alternative for the Great Lakes. The load effects studies showed that the two-blade wind turbine model experiences less torque under all IEC Standard design load cases considered. Other load effects did not show this trend and depending on the design load cases, the two-bladed wind turbine showed higher or lower load effects. The experimental studies of the wake were conducted using smoke flow visualization and hot wire anemometry. Flow visualization studies showed that in the downwind turbine configuration the wake flow was insensitive to the presence of the blade and was very similar to that of the tower alone. On the other hand, in the upwind turbine configuration, increasing the rotor blade angle of attack reduced the wake size and enhanced the vortices in the flow downstream of the turbine-tower compared with the tower alone case. Mean and rms velocity distributions from hot wire anemometer data confirmed that in a downwind configuration, the wake of the tower dominates the flow, thus the flow fields of a tower alone and tower-turbine combinations are nearly the same. For the upwind configuration, the mean velocity shows a narrowing of the wake compared with the tower alone case. The downwind configuration wake persisted longer than that of an upwind configuration; however, it was not possible to quantify this difference because of the size limitation of the wind tunnel downstream of the test section. The water tunnel studies demonstrated that the scale model studies could be used to adequately produce accurate motions to model the motions of a wind turbine platform subject to large waves. It was found that the important factors that affect the platform is whether the platform is submerged or surface piercing. In the former, the loads on the platform will be relatively reduced whereas in the latter case, the structure pierces the wave free surface and gains stiffness and stability. The other important element that affects the movement of the platform is depth of the sea in which the wind turbine will be installed. Furthermore, the wildlife biology component evaluated migratory patterns by different monitoring systems consisting of marine radar, thermal IR camera and acoustic recorders. The types of radar used in the project are weather surveillance radar and marine radar. The weather surveillance radar (1988 Doppler), also known as Next Generation Radar (NEXRAD), provides a network of weather stations in the US. Data generated from this network were used to understand general migratory patterns, migratory stopover habitats, and other patterns caused by the effects of weather conditions. At a local scale our marine radar was used to complement the datasets from NEXRAD and to collect additional monitoring parameters such as passage rates, flight paths, flight directions, and flight altitudes of nocturnal migrating species. Our work focused on the design and development of custom built marine radar that used t-bar and parabolic dish antennas. The marine radar used in the project was Furuno (XANK250) which was coupled with a XIR3000B digitizing card from Russell Technologies for collection of the radar data. The radar data was processed by open source radR processing software using different computational techniques and methods. Additional data from thermal IR imaging cameras were collected to detect heat emitted from objects and provide information on movements of birds and bats, data which we used for different animal flight behavior analysis. Lastly, the data from the acoustic recorders were used to provide the number of bird calls for assessing patterns and peak passage rates during migration. The development of the geospatial database included collection of different data sources that are used to support offshore wind turbine development. Many different data sets were collected and organized using initial version of web-based repository software tools that can accommodate distribution of rectified pertinent data sets such as the lake depth, lake bottom engineering parameters, extent of ice, navigation pathways, wind speed, important bird habitats, fish efforts and other layers that are relevant for supporting robust offshore wind turbine developments. Additional geospatial products developed during the project included few different prototypes for offshore wind farm suitability which can involve different stakeholders and participants for solving complex planning problems and building consensus. Some of the prototypes include spatial decision support system (SDSS) for collaborative decision making, a web-based Participatory Geographic Information System (PGIS) framework for evaluating importance of different decision alternatives using different evaluation criteria, and an Android application for collection of field data using mobile and tablet devices . In summary, the simulations of two- and three-blade wind turbines suggested that two-bladed machines could produce comparable annual energy as the three-blade wind turbines but have a lighter tower top weight, which leads to lower cost of energy. In addition, the two-blade rotor configuration potentially costs 20% less than a three blade configuration that produces the same power at the same site. The cost model analysis predicted a potential cost savings of approximately 15% for offshore two-blade wind turbines. The foundation design for a wind turbine in Lake Erie is likely to be driven by ice loads based on the currently available ice data and ice mechanics models. Hence, for Lake Eire, the cost savings will be somewhat smaller than the other lakes in the Great Lakes. Considering the size of cranes and vessels currently available in the Great Lakes, the cost optimal wind turbine size should be 3 MW, not larger. The surveillance data from different monitoring systems suggested that bird and bat passage rates per hour were comparable during heavy migrations in both spring and fall seasons while passage rates were significantly correlated to wind directions and wind speeds. The altitude of migration was higher during heavy migrations and higher over water relative to over land. Notable portions of migration on some spring nights occurred parallel the shoreline, often moving perpendicular to southern winds. The birds approaching the Western basin have a higher propensity to cross than birds approaching the Central basin of Lake Erie and as such offshore turbine development might be a better option further east towards Cleveland than in the Western basin. The high stopover density was more strongly associated with migration volume the following night rather than the preceding night. The processed mean scalar wind speeds with temporal resolutions as fine as 10-minute intervals near turbine height showed that August is the month with the weakest winds while December is the month, which typically has the strongest winds. The ice data suggests that shallow western basin of Lake Erie has higher ice cover duration many times exceeding 90 days during some winters.

17 WIND ENERGY↗

Diffusive release of uranium from contaminated sediments into capillary fringe pore water

Despite remediation efforts at the former nuclear weapons facility at the Hanford site (Washington State), leaching of uranium (U) from contaminated sediments to the ground water persists at the Hanford 300 Area. Flooding of contaminated capillary fringe sediments due to seasonal changes in the Columbia River stage has been identified as a reason of continued U supply to ground water. We investigated the release of U from Hanford capillary fringe sediments to pore water. Contaminated Hanford sediments were packed into reservoirs of centrifugal filter devices and saturated with Columbia River water for 3 to 84 days at varying solution-to-solid ratios (1:3, 1:1, 5:1, 10:1, 25:1 mL:g). After specified times, samples were centrifuged to a gravimetric water content of 0.11 ± 0.06 g g-1. Within the first three days, there was an initial rapid release of 6-9% of total U from the sediments into the pore water, independent of the solution-to-solid ratio. After 14 days of reaction, however, the experiments with the narrowest solution-to-solid ratios (1:3 and 1:1 mL:g) showed a decline in dissolved U concentrations. The removal of U from the solution phase was accompanied by removal of Ca and HCO3-. Geochemist workbench simulations, conducted using measured solution concentrations from experiments, indicated that calcite could precipitate in the 1:3 solution-to-solid ratio experiment. After the rapid initial release in the first three days for the 5:1, 10:1, and 25:1 solution-to-solid ratio experiments, there was sustained release of U into the pore water. Up to 22% of total U was released on day 84 for the 25:1 solution-to-solid ratio reaction. This sustained release of U from the sediments had diffusion-limited kinetics.

contaminated sediments↗

Remediation Guidance for Major Airports after a Bioterrorist Attack

This document provides general guidelines for airport managers, local officials, and other stakeholders for developing a response and recovery plan for a major airport following the release of a biological warfare agent, with specific guidance for remediation. San Francisco International Airport was selected as the example airport during development of the guidance to illustrate specific details. The spore-forming bacterium Bacillus anthracis was selected as the biological agent of primary concern because it is the most difficult of known bioterrorism agents to inactivate and is considered to be one of the agents most likely to be used as a biological weapon. The focus of the guidance is on cleanup and disposal activities associated with the Characterization, Decontamination, and Clearance Phases that are defined herein. Activities associated with the Notification and First-Response Phases are brieÀy discussed in Appendixes A and B, respectively. In addition to the main text of this Remediation Guidance document and associated appendixes, a data supplement was developed specifically for San Francisco International Airport. Requests for the data supplement must be made directly to the Emergency Planning Operations Division of San Francisco International Airport. This document does not describe public health responses to release of a biological warfare agent. If laboratory analytical results confirm the presence of a biological agent, the responsible public health agency involved in the response will commence appropriate public health actions, such as treatment (CDC 2004) and decontamination of potentially contaminated individuals, distribution of prophylaxis, and medical examinations. See the Centers for Disease Control and Prevention web site for more information on emergency public health responses (http://www.bt.cdc.gov/). Effective communication with the media and the public is an essential component of airport remediation and recovery. Whereas such communication is beyond the scope of this document, many helpful resources are available. (See Section 1.1 for more information.) The concept of operations described in this document for cleanup of a Bacillus anthracis release at a major airport conforms to the National Response Framework (NRF) (DHS 2008) and implementation of the National Incident Management System (NIMS 2004). In most cases, a Unified Command would be formed to direct the cleanup process jointly and to take ultimate responsibility for all cleanup decisions. The Unified Command would likely include the Airport Manager or Airport Emergency Operations Manager, representatives from state and local public health and emergency management agencies, and Federal agencies, such as the U.S. Environmental Protection Agency. The Unified Command and Incident Command Staff would ideally be co-located in an Incident Command Post in an uncontaminated area of the airport. If a release is large or complex, co-location of all key players may not be possible. If a major incident is declared, a Principal Federal Official may be appointed by the Department of Homeland Security to facilitate Federal support to the Unified Command. In some facilities and jurisdictions, additional response plans or procedures (such as BioWatch or other emergency response plans, procedures, or protocols) may govern notification and first response. Facility personnel, responders, and emergency management coordinators should be aware of all applicable plans and procedures and how to implement them. Cleanups following the anthrax attacks of 2001 in the U.S. pre-dated the NRF and NIMS and did not make use of a NIMS Incident Command System as we know it today. Most Incident Commanders for the larger of those cleanups chose to convene a Technical Working Group (TWG) of multi-agency, multi-disciplinary, outside experts to advise in developing sampling and decontamination plans. Most of the Incident Commanders also convened a separate Environmental Clearance Committee (ECC) to independently review pre- and post decontamination sampling data as well as data on decontamination parameters, to evaluate whether the decontamination was effective, and to add credibility regarding a decision that decontaminated areas may be reoccupied. Use of such specialized technical expertise is strongly recommended, although it would now operate within the construct of the NIMS Incident Command System. The TWG, if convened, would act in an advisory capacity to the Environmental Unit within the Planning Section. Likewise, the ECC, if convened, would provide independent peer review of products and recommendations by the Environmental Unit. For maximum impartiality, the ECC could also provide recommendations directly to the Unified Command. Cleanup activities commence with site characterization. The principal goal of characterization is to define the extent of contamination and to gather information needed to design the decontamination approach. Initial sampling data collected by first responders are assessed to approximate the location(s) of contamination. Confirmation of the agent type and viability is obtained from a Laboratory Response Network laboratory. Additional characterization data are collected to determine the extent of contamination and where decontamination actions are needed. Areas suspected of being contaminated are contained and isolated to the degree possible to prevent further movement of an agent to uncontaminated areas or the environment, and to reduce the potential for future exposure from the agent or fumigant, if fumigation is needed. Agent air monitoring in areas adjacent to the contained contamination zones is done to ensure the protection of remediation personnel and to monitor any release from the contained zones. Various sampling approaches are considered. For example, wipe samples can be used to sample hard, nonporous surfaces. Swab samples can be used to sample nooks, crannies, joints, and seams. Appendix I is a template for preparing an incident-specific, operational characterization plan. Upon completion of the characterization plan, an internal review is initiated. Upon approval of the plan by the Unified Command, characterization commences. The Site Safety Officer develops a Health and Safety Plan to ensure that coordinated health and safety measures are in place for all responding personnel. This plan describes physical, chemical, and biological hazards at the site, personal protective equipment, personal decontamination procedures, and emergency procedures to be used by sampling and remediation personnel. An incident-specific Remediation Action Plan is developed, which describes the decontamination methods to be used and other details, including waste disposal. Under NIMS, this overall plan, as well as other plans described below, are implemented through a series of standardized, shorter-term Incident Action Plans, which describe specific activities that will take place during a shift or a day. The template in Appendix J is designed to facilitate preparation of the Remediation Action Plan. If fumigation will be done, a Sampling and Analysis Plan will be needed, as well as an Ambient Air Monitoring Plan, which can be a component of the Remediation Action Plan. These three plans are needed to obtain a crisis exemption from the U.S. Environmental Protection Agency for authorized use of an unregistered sterilant or pesticide during cleanup. If pesticide products become registered for inactivation of B. anthracis in the future, the three plans will likely be required by the product’s labeling, but the plans would no longer be submitted to the U.S. Environmental Protection Agency for approval; rather, the Incident Commander would approve them. If fumigation is used, an Emergency Response Plan is also recommended, although such a plan is not required for a crisis exemption. For some nonpersistent biological warfare agents, natural attenuation may be an adequate decontamination option. In cases where contamination is not extensive or an agent is not persistent, application of surface decontaminants or other methods of medical infection control may be effective. For extensive contamination by persistent agents, such as Bacillus anthracis, fumigation may be necessary. In those cases, the Decontamination Phase commences with source reduction, such as pre-cleaning surfaces to reduce the contaminant load. To expedite cleanup and prevent costs from escalating unnecessarily, a cost–benefit analysis should be incorporated in the decision process related to retention versus disposal of facility items and materials. Certain materials and structural components can be decontaminated for reuse, but it may not be feasible or cost-effective to decontaminate other items. Those items must be pre-treated, packaged (with the package decontaminated externally), and removed for disposal as waste. Site preparation includes sealing openings to prevent leaks and setting up equipment. Decontamination reagents and delivery systems are selected, and pre-testing all systems is done before carrying out chemical treatment(s). The important choice of decontamination technologies depends on characteristics of the agent, the nature and extent of contamination, and other site parameters identified during characterization. Decontamination-related decisions can have a major impact on waste-disposal costs, and it is necessary to develop a disposal plan that identifies a means of disposal, necessary approvals, transportation, and other details. A clearance strategy is developed to ensure that after decontamination, the risk of exposure to residual contamination is negligible. A clearance sampling plan is developed, which sets clearance criteria, specifies how to determine whether the criteria have been met, and describes how and where to collect clearance samples after decontamination. In most cases, clearance sampling includes both surface and aggressive air samples. Appendix K is a clearance plan template that identifies the types of required information. To determine whether the decontaminated area may be reoccupied, the Environmental Unit (and the ECC separately, if one is convened) evaluates the results of clearance samples. For the anthrax incidents to date, and given methods that have been used, cleanup was considered successful only when there was no growth of B. anthracis cultured from any environmental samples taken after decontamination. Other factors that will be considered include the decontamination process parameters (e.g., temperature, relative humidity, decontaminant concentration, and contact time) and the results from post-decontamination culture of biological indicators that may have been used during fumigation or sterilization processes. From such an evaluation the Environmental Unit or ECC, or both, recommend whether the area may be reoccupied, or whether further decontamination is necessary. The UC makes the final decision that a facility is appropriately decontaminated for reoccupancy. The facility owner or responsible public health agency makes the final decision to reopen a decontaminated facility. A theme that is emphasized throughout this document is that many activities can greatly reduce the time required to restore airport operations if those activities are conducted prior to an actual release of biological warfare agent. A summary of specific resources (such as Federal, state, and local agency contacts; contractors; prospective team members; subject-matter experts; laboratory facilities; and other entities) that should be identified in advance by airport officials is provided in each pertinent section of this document, and summary contact lists of such resources are provided in Appendix L. A summary of overall pre-planning actions that should be completed by airport officials is presented at the end of this document.

59 BASIC BIOLOGICAL SCIENCES↗