Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pixel Array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Wide field and diffraction limited array camera for SIRTF

The Infrared Array Camera for the Space Infrared Telescope Facility (SIRTF/IRAC) is capable of two-dimensional photometry in either a wide field or diffraction-limited mode over the wavelength interval from 2 to 30 microns. Three different two-dimensional direct readout (DRO) array detectors are being considered: Band 1-InSb or Si:In (2-5 microns) 128 x 128 pixels, Band 2-Si:Ga (5-18 microns) 64 x 64 pixels, and Band 3-Si:Sb (18-30 microns) 64 x 64 pixels. The hybrid DRO readout architecture has the advantages of low read noise, random pixel access with individual readout rates, and nondestructive readout. The scientific goals of IRAC are discussed, which are the basis for several important requirements and capabilities of the array camera: (1) diffraction-limited resolution from 2-30 microns, (2) use of the maximum unvignetted field of view of SIRTF, (3) simultaneous observations within the three infrared spectral bands, and (4) the capability for broad and narrow bandwidth spectral resolution. A strategy has been developed to minimize the total electronic and environmental noise sources to satisfy the scientific requirements.

Fazio, G. G.↗

Hybrid UV Imager Containing Face-Up AlGaN/GaN Photodiodes

A proposed hybrid ultraviolet (UV) image sensor would comprise a planar membrane array of face-up AlGaN/GaN photodiodes integrated with a complementary metal oxide/semiconductor (CMOS) readout-circuit chip. Each pixel in the hybrid image sensor would contain a UV photodiode on the AlGaN/GaN membrane, metal oxide/semiconductor field-effect transistor (MOSFET) readout circuitry on the CMOS chip underneath the photodiode, and a metal via connection between the photodiode and the readout circuitry (see figure). The proposed sensor design would offer all the advantages of comparable prior CMOS active-pixel sensors and AlGaN UV detectors while overcoming some of the limitations of prior (AlGaN/sapphire)/CMOS hybrid image sensors that have been designed and fabricated according to the methodology of flip-chip integration. AlGaN is a nearly ideal UV-detector material because its bandgap is wide and adjustable and it offers the potential to attain extremely low dark current. Integration of AlGaN with CMOS is necessary because at present there are no practical means of realizing readout circuitry in the AlGaN/GaN material system, whereas the means of realizing readout circuitry in CMOS are well established. In one variant of the flip-chip approach to integration, an AlGaN chip on a sapphire substrate is inverted (flipped) and then bump-bonded to a CMOS readout circuit chip; this variant results in poor quantum efficiency. In another variant of the flip-chip approach, an AlGaN chip on a crystalline AlN substrate would be bonded to a CMOS readout circuit chip; this variant is expected to result in narrow spectral response, which would be undesirable in many applications. Two other major disadvantages of flip-chip integration are large pixel size (a consequence of the need to devote sufficient area to each bump bond) and severe restriction on the photodetector structure. The membrane array of AlGaN/GaN photodiodes and the CMOS readout circuit for the proposed image sensor would be fabricated separately.

Zheng, Xinyu↗

Efficient Mirrorlet Array Based Integral Field Spectrometer for HWO

Habitable World Observatory (HWO) is a NASA strategic mission recommended by 2020 astronomical decadal survey. Integral spectrometers play an important role to verify if the observed exoplanet is habitable. The traditional lenslet array based Integral Field Spectrometer (IFS) has the advantage of simplicity and compactness. However, it does not use detector pixels efficiently in order to prevent wavelength crosstalk among adjacent spectra. The efficient lenslet/mirrorlet IFS combines the advantages from both lenslet based and imager slicer based IFSes—keeping lenslet IFS’s simplicity and compactness, concurrently adding slicer IFS’s detector efficiency. This paper discusses the principle of efficient lenslet/mirrorlet IFS, design philosophy, and efficient spectral trace layout ideals. It uses HWO NIR IFS requirement as an example to provide an efficiency mirrorlet IFS optical design. The high detector efficiency not only reduces Needed detector pixel numbers, but also reduce the high communication rate demanding for much a large multiple instrument mission. The basic idea of the efficient lenslet/mirrorlet array IFS is to design a lenslet/mirrorlet array in such a way that the images from multiple mirrorlets are grouped and aligned as a spectrum from a single slit. Therefore, the number of detector rows used to prevent wavelength crosstalk is no longer needed. This paper is also going to address how to lay the traces on the detector and what is the difference from the traditional lenslet IFS. Our goal is to show that such an IFS is capable to lay all spectral traces onto a 2k x 2k detector array using HWO NIR requirement that has a higher spectral resolving power R = 70 and a large Field of View (FOV) of 96 λ/D.

Exoplanet↗

Large Format Si:As IBC Array Performance for NGST and Future IR Space Telescope Applications

A mid-IR (5-30micrometer) instrument aboard a cryogenic space telescope can have an enormous impact in resolving key questions in astronomy and cosmology. A space platform's greatly reduced thermal backgrounds (compared to airborne or ground-based platforms), allow for more sensitive observations of dusty young galaxies at high redshifts, star formation of solar-type stars in the local universe, and formation and evolution of planetary disks and systems. The previous generation's largest, in sensitive IR detectors at these wavelengths are 256x256 pixel Si:As Impurity Band Conduction (IBC) devices built by Raytheon Infrared Operations (RIO) for the Space Infrared Telescope Facility/Infrared Array Camera (SIRTF)/(IRAC) instrument. RIO has successfully enhanced these devices, increasing the pixel count by a factor of 16 while matching or exceeding SIRTF/IRAC device performance. NASA-ARC in collaboration with RIO has tested the first high performance large format (1024x 1024) Si:As IBC arrays for low background applications, such as for the middle instrument on Next Generation Space Telescope (NGST) and future IR Explorer missions. These hybrid devices consist of radiation hard SIRTF/IRAC-type Si:As IBC material mated to a readout multiplexer that has been specially processed for operation at low cryogenic temperatures (below 10K), yielding high device sensitivity over a wavelength range of 5-28 micrometers. We present laboratory testing results from these benchmark, devices. Continued development in this technology is essential for conducting large-area surveys of the local and early universe through observation and for complementing future missions such as NGST, Terrestrial Planet Finder (TPF), and Focal Plane Instruments and Requirement Science Team (FIRST).

Ennico, Kimberly↗

Position-Sensitive Magnetic Calorimeters for Lynx

We describe the performance of position-sensitive metallic magnetic calorimeter X-ray detectors for potential future astrophysics missions, such as Lynx. The motivation behind this is to achieve a large focal plane area by increasing the number of pixels compared to the number of readout channels (called hydra). The detector consists of a 5×5 array of gold absorbers thermally coupled to a paramagnetic sensor. Since each absorber has a different thermal link to the sensor, it generates a different pulse shape and enables discrimination of pixel position. Recently, we have been successfully able to discriminate 25 averaged pulse shapes by means of rise-time and pulse height. The measured pulse shapes and distribution agree well with the modeling results. The estimated energy resolutions based on the pulse height and noise data we measured are 2.8–3.7 eV for MnKα X-ray photons at 50 mK.

Magnetic calorimeters↗

Feasibility study for locating archaeological village sites by satellite remote sensing techniques

The author has identified the following significant results. The objective is to determine the feasibility of detecting large Alaskan archaeological sites by satellite remote sensing techniques and mapping such sites. The approach used is to develop digital multispectral signatures of dominant surface features including vegetation, exposed soils and rock, hydrological patterns and known archaeological sites. ERTS-1 scenes are then printed out digitally in a map-like array with a letter reflecting the most appropriate classification representing each pixel. Preliminary signatures were developed and tested. It was determined that there was a need to tighten up the archaeological site signature by developing accurate signatures for all naturally-occurring vegetation and surface conditions in the vicinity of the test area. These second generation signatures have been tested by means of computer printouts and classified tape displays on the University of Alaska CDU-200 and by comparison with aerial photography. It has been concluded that the archaeological signatures now in use are as good as can be developed. Plans are to print out signatures for the entire test area and locate on topographic maps the likely locations of archaeological sites within the test area.

Cook, J. P.↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

Extrinsic germanium photoconductors for far-IR astronomy: Research results and works in progress

Some Ge:Ga and Ge:Sb photoconductor materials and detectors that are currently under development are reported. The best Ge:Ga devices exhibit dark currents of lower than 200 electrons/s, with a concurrent responsivity of 2 A/W and a detective quantum efficiency (DQE) of 5 percent. For higher backgrounds, an operating temperature of 3 K can be used. This increases the DQE to 7 percent and the responsivity to 4.5 A/W. Investigations were initiated into n-type Ge:Sb as an alternative photoconductive material. Two crystals of Ge:Sb were grown and a number of test detectors were fabricated and evaluated. At 2 K, the best device produced dark currents of less than 100 electrons/s with concurrent responsivity of 1 A/W and DQE of 4 percent, and at 3 K, produced currents of 10(exp 5) electrons/s with a DQE of 7 percent and a responsivity of 4 A/W. Using p-type Ge:Ga crystals, two dimensional monolithic photoconductor arrays are being constructed. Future work will focus on measuring pixel-to-pixel homogeneity, cross talk issues, overall sensitivity and suitability for photometric instruments.

Beeman, J. W.↗

Satellite Calibration With LED Detectors at Mud Lake

Earth-monitoring instruments in orbit must be routinely calibrated in order to accurately analyze the data obtained. By comparing radiometric measurements taken on the ground in conjunction with a satellite overpass, calibration curves are derived for an orbiting instrument. A permanent, automated facility is planned for Mud Lake, Nevada (a large, homogeneous, dry lakebed) for this purpose. Because some orbiting instruments have low resolution (250 meters per pixel), inexpensive radiometers using LEDs as sensors are being developed to array widely over the lakebed. LEDs are ideal because they are inexpensive, reliable, and sense over a narrow bandwidth. By obtaining and averaging widespread data, errors are reduced and long-term surface changes can be more accurately observed.

Hiller, Jonathan D.↗

Comparison of Measured Leakage Current Distributions with Calculated Damage Energy Distributions in HgCdTe

This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distribution were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [I]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Car10 code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. The nuclear elastic component (also calculated using the MCNPX) has a negligible effect on the shape of the damage distribution. The Coulombic contribution was calculated using MRED [3,4], a Geant4 [4,5] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

Marshall, C. J.↗

Comparison of Measured Dark Current Distributions with Calculated Damage Energy Distributions in HgCdTe

This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distributions were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [1]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Carlo code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. While the nuclear elastic component (also calculated using the MCNPX) contributes only a small fraction of the total nonionizing damage energy, its inclusion in the shape of the damage across the array is significant. The Coulombic contribution was calculated using MRED [3-5], a Geant4 [4,6] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

Marshall, C. J.↗

AXTAR: Mission Design Concept

The Advanced X-ray Timing Array (AXTAR) is a mission concept for X-ray timing of compact objects that combines very large collecting area, broadband spectral coverage, high time resolution, highly flexible scheduling, and an ability to respond promptly to time-critical targets of opportunity. It is optimized for sub-millisecond timing of bright Galactic X-ray sources in order to study phenomena at the natural time scales of neutron star surfaces and black hole event horizons, thus probing the physics of ultra-dense matter, strongly curved spacetimes, and intense magnetic fields. AXTAR s main instrument, the Large Area Timing Array (LATA) is a collimated instrument with 2 50 keV coverage and over 3 square meters effective area. The LATA is made up of an array of super-modules that house 2-mm thick silicon pixel detectors. AXTAR will provide a significant improvement in effective area (a factor of 7 at 4 keV and a factor of 36 at 30 keV) over the RXTE PCA. AXTAR will also carry a sensitive Sky Monitor (SM) that acts as a trigger for pointed observations of X-ray transients in addition to providing high duty cycle monitoring of the X-ray sky. We review the science goals and technical concept for AXTAR and present results from a preliminary mission design study

Ray, Paul S.↗

Reducing the Read Noise of the James Webb Space Telescope Near Infrared Spectrograph Detector Subsystem

We describe a Wiener optimal approach to using the reference output and reference pixels that are built into Teledyne's HAWAII-2RG detector arrays. In this way, we are reducing the total noise per approximately 1000 second 88 frame up-the-ramp dark integration from about 6.5 e- rms to roughly 5 e- rms. Using a principal components analysis formalism, we achieved these noise improvements without altering the hardware in any way. In addition to being lower, the noise is also cleaner with much less visible correlation. For example, the faint horizontal banding that is often seen in HAWAII-2RG images is almost completely removed. Preliminary testing suggests that the relative gains are even higher when using non flight grade components. We believe that these techniques are applicable to most HAWAII-2RG based instruments.

Rauscher, Bernard↗

Development of a 2K x 2K GaAs QWIP Focal Plane Array

We are developing the next generation of GaAs Quantum Well Infrared Photodetector (QWIP) focal plane arrays (FPAs) in preparation for future NASA space-borne Earth observing missions. It is anticipated that these missions will require both wider ground spatial coverage as well as higher ground imaging resolution. In order to demonstrate our capability in meeting these future goals we have taken a two-tiered approach in the next stage of advanced QWIP focal plane array development. We will describe our progress in the development of a 512 x 3,200 (512 x 3K) array format for this next generation thermal imaging array for the NASA Landsat project. However, there currently is no existing readout integrated circuit (ROIC) for this format array.so to demonstrate the ability to scale-up an existing ROIC we developed a 1,920 x 2,048 (2K x 2K) array and it hybridized to a Raytheon SB419 CTIA readout integrated circuit that was scaled up from their existing 512 x 640 SB339 ROIC. Two versions of the 512 x 3K QWIP array were fabricated to accommodate a future design scale-up of both the Indigo 9803 ROIC based on a 25 micron pixel dimension and a scale up of the Indigo 9705 ROIC based on a 30 micron pixel dimension. Neither readout for the 512 x 3K has yet to be developed but we have fabricated both versions of the array. We describe the design, development and test results of this effort as well as the specific applications these FPAs are intended to address.

Jhabvala, M.↗

Snowballs in Euclid and WFIRST Detectors

Snowballs are transient events observed in HgCdTe detectors with a sudden increase of charge in a few pixels. They appear between consecutive reads of the detector, after which the affected pixels return to their normal behavior. The origin of the snowballs is unknown, but it was speculated that they could be the result of alpha decay of naturally radioactive contaminants in the detectors, but a cosmic ray origin cannot be ruled out. Even though previous studies predicted a low rate of occurrence of these events, and consequently, a minimal impact on science, it is interesting to investigate the cause or causes that may generate snowballs and their impact in detectors designed for future missions. We searched for the presence of snowballs in the dark current data in Euclid and Wide Field Infrared Survey Telescope (WFIRST) detectors tested in the Detector Characterization Laboratory at Goddard Space Flight Center. Our investigation shows that for Euclid and WFIRST detectors, there are snowballs that appear only one time, and others that repeat in the same spatial localization. For Euclid detectors, there is a correlation between the snowballs that repeat and bad pixels in the operational masks (pixels that do not fulfill the requirements to pass spectroscopy noise, photometry noise, quantum efficiency, and/or linearity). The rate of occurrence for a snowball event is about 0.9 snowballs/hr. in Euclid detectors (for the ones that do not have associated bad pixels in the mask), and about 0.7 snowballs/hr. in PV3 Full Array Lot WFIRST detectors.

Astronomy↗

Principal Component Analysis of Up-The-Ramp Sampled Infrared Array Data

We describe the results of principal component analysis (PCA) of up-the-ramp sampled infrared (IR) array data from the Hubble Space Telescope wide field camera 3 (WFC3 IR), James Webb Space Telescope NIRSpec, and prototype Wide Field Infrared Survey Telescope’s wide field instrument detectors. These systems use, respectively, Teledyne H1R, H2RG, and H4RG-10 near-IR detector arrays with a variety of IR array controllers. The PCA shows that the Legendre polynomials approximate the principal components of these systems (i.e., they roughly diagonalize the covariance matrix). In contrast to the monomial basis that is widely used for polynomial fitting and linearization today, the Legendre polynomials are an orthonormal basis. They provide a quantifiable, compact, and (nearly) linearly uncorrelated representation of the information content of the data. By fitting a few Legendre polynomials, nearly all of the meaningful information in representative WFC3 astronomical datacubes can be condensed from 15 up-the-ramp samples down to 6 compressible Legendre coefficients per pixel. The higher order coefficients contain time domain information that is lost when one projects up-the-ramp sampled datacubes onto two-dimensional images by fitting a straight line, even if the data are linearized before fitting the line. Going forward, we believe that this time domain information is potentially important for disentangling the various nonlinearities that can affect IR array observations, i.e., inherent pixel nonlinearity, persistence, burn in, brighter-fatter effect, (potentially) nonlinear interpixel capacitance, and perhaps others.

Rauscher, Bernard J.↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Application of a single area array detector for acquistion, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗