Search NASA⌕ Search

SEARCH · Search NASA

Results for “Position Sensitive Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Numerical assessment of uncertainty and dynamic range expansion of multispectral image-based pyrometry

Temperature measurements based on spectral radiation are often limited by prior knowledge of target surface properties and detector sensitivity. Here the present work describes a multispectral pyrometry method for temperature estimation that does not require information on surface emissivity or calibration. Digital camera simulations considering a silicon-based sensor and five bandpass filters are used to create synthetic images of targets. The detector sensitivity is compensated via high dynamic range imaging technique. The effect of natural and detector noise on temperature estimates is assessed via Monte Carlo simulations. Results from a wavelength-independent model (Gray) are compared with those from the Band model (with emissivity varying between constant spectral bands). The effect of detector dynamic range and spectral position of bandpass filters is discussed. Temperatures as low as 520 K are obtained, with an overall uncertainty of the order of 10 K. The proposed method is applicable to temperature measurements using commercial-grade CMOS/CCD cameras.

42 ENGINEERING↗

Quartz Detector for the SuperHMS Spectrometer at Hall-C Jefferson Lab

We have developed and constructed a quartz hodoscope to be part of the trigger system for the Super High Momentum Spectrometer (SHMS). The SHMS spectrometer will play a central role in carrying out the 12-GeVphysics program at Hall-C Jefferson Lab. The hodoscope consists of twenty one fused silica bars. Each bar is 125-cm long, 5.5-cm wide, and 2.5-cm thick. It is viewed by a UV-sensitive PMT on each end. The quartz hodoscope task is to provide a clean detection of charged particles, a high level of background suppression, and an accurate tracking efficiency determination. We present results of tests leading to the construction of the hodoscope, as well performance test results of the completed detectors such as detection efficiency and position resolution.

Ahmidouch, Abdellah↗

Microfabrication of High Resolution X-ray Magnetic Calorimeters

Metallic magnetic calorimeter (MMC) is one of the most promising x-ray detector technologies for providing the very high energy resolution needed for future astronomical x-ray imaging spectroscopy. For this purpose, we have developed micro-fabricated 5x5 arrays of MMC of which each individual pixel has excellent energy resolution as good as 3.4 eV at 6 keV x-ray. Here we report on the fabrication techniques developed to achieve good resolution and high efficiency. These include: processing of a thin insulation layer for strong magnetic coupling between the AuEr sensor film and the niobium pick-up coil; production of overhanging absorbers for enhanced efficiency of x-ray absorption; fabrication on SiN membranes to minimize the effects on energy resolution from athermal phonon loss. We have also improved the deposition of the magnetic sensor film such that the film magnetization is nearly completely that is expected from the AuEr sputter target bulk material. In addition, we have included a study of a positional sensitive design, the Hydra design, which allows thermal coupling of four absorbers to a common MMC sensor and circuit.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multibaseline gravitational wave radiometry

We present a statistic for the detection of stochastic gravitational wave backgrounds (SGWBs) using radiometry with a network of multiple baselines. We also quantitatively compare the sensitivities of existing baselines and their network to SGWBs. We assess how the measurement accuracy of signal parameters, e.g., the sky position of a localized source, can improve when using a network of baselines, as compared to any of the single participating baselines. The search statistic itself is derived from the likelihood ratio of the cross correlation of the data across all possible baselines in a detector network and is optimal in Gaussian noise. Specifically, it is the likelihood ratio maximized over the strength of the SGWB and is called the maximized-likelihood ratio (MLR). One of the main advantages of using the MLR over past search strategies for inferring the presence or absence of a signal is that the former does not require the deconvolution of the cross correlation statistic. Therefore, it does not suffer from errors inherent to the deconvolution procedure and is especially useful for detecting weak sources. In the limit of a single baseline, it reduces to the detection statistic studied by Ballmer [Classical Quantum Gravity 23, S179 (2006).] and Mitra et al.[Phys. Rev. D 77, 042002 (2008).]. Unlike past studies, here the MLR statistic enables us to compare quantitatively the performances of a variety of baselines searching for a SGWB signal in (simulated) data. Although we use simulated noise and SGWB signals for making these comparisons, our method can be straightforwardly applied on real data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GPS-Based Gamma Survey for Characterizing and Decommissioning NORM Sites - 20389

Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-32: Evaluation of the Performance of a Multiple-Array-Diode Detector for Quality Assurance Tests in High-Dose-Rate Brachytherapy with Ir-192 Source

Purpose: To evaluate the performance of a two-dimensional (2D) array-diode- detector for geometric and dosimetric quality assurance (QA) tests of high-dose-rate (HDR) brachytherapy with an Ir-192-source. Methods: A phantom setup was designed that encapsulated a two-dimensional (2D) array-diode-detector (MapCheck2) and a catheter for the HDR brachytherapy Ir-192 source. This setup was used to perform both geometric and dosimetric quality assurance for the HDR-Ir192 source. The geometric tests included: (a) measurement of the position of the source and (b) spacing between different dwell positions. The dosimteric tests include: (a) linearity of output with time, (b) end effect and (c) relative dose verification. The 2D-dose distribution measured with MapCheck2 was used to perform the previous tests. The results of MapCheck2 were compared with the corresponding quality assurance testes performed with Gafchromic-film and well-ionization-chamber. Results: The position of the source and the spacing between different dwell-positions were reproducible within 1 mm accuracy by measuring the position of maximal dose using MapCheck2 in contrast to the film which showed a blurred image of the dwell positions due to limited film sensitivity to irradiation. The linearity of the dose with dwell times measured from MapCheck2 was superior to the linearity measured with ionization chamber due to higher signal-to-noise ratio of the diode readings. MapCheck2 provided more accurate measurement of the end effect with uncertainty < 1.5% in comparison with the ionization chamber uncertainty of 3%. Although MapCheck2 did not provide absolute calibration dosimeter for the activity of the source, it provided accurate tool for relative dose verification in HDR-brachytherapy. Conclusion: The 2D-array-diode-detector provides a practical, compact and accurate tool to perform quality assurance for HDR-brachytherapy with an Ir-192 source. The diodes in MapCheck2 have high radiation sensitivity and linearity that is superior to Gafchromic-films and ionization chamber used for geometric and dosimetric QA in HDR-brachytherapy, respectively.

60 APPLIED LIFE SCIENCES↗

IR Spectrometer Using 90-Degree Off-Axis Parabolic Mirrors

A gated spectrometer has been designed for real-time, pulsed infrared (IR) studies at the National Synchrotron Light Source at the Brookhaven National Laboratory. A pair of 90-degree, off-axis parabolic mirrors are used to relay the light from an entrance slit to an output recording camera. With an initial wavelength range of 1500–4500 nm required, gratings could not be used in the spectrometer because grating orders would overlap. A magnesium oxide prism, placed between these parabolic mirrors, serves as the dispersion element. The spectrometer is doubly telecentric. With proper choice of the air spacing between the prism and the second parabolic mirror, any spectral region of interest within the InSb camera array’s sensitivity region can be recorded. The wavelengths leaving the second parabolic mirror are collimated, thereby relaxing the camera positioning tolerance. To set up the instrument, two different wavelength (visible) lasers are introduced at the entrance slit and made collinear with the optical axis via flip mirrors. After dispersion by the prism, these two laser beams are directed to tick marks located on the outside housing of the gated IR camera. This provides first-order wavelength calibration for the instrument. Light that is reflected off the front prism face is coupled into a high-speed detector to verify steady radiance during the gated spectral imaging. Alignment features include tick marks on the prism and parabolic mirrors. This instrument was designed to complement single-point pyrometry, which provides continuous time histories of a small collection of spots from shock-heated targets.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of a Lanthanum Bromide Detector and a New Conception Collimator for Radiopharmaceuticals Molecular Imaging in Oncology

We have realized and tested a new-design compact gamma camera for high resolution SPET (Single Photon Emission Tomography), and small animals' radio-pharmaceutical molecular imaging. The camera is based on a 'continuous' Lanthanum tri-Bromide crystal, and a new Low Energy (LE) collimator. The crystal is interfaced to a 2x2 array of Hamamatsu-H8500 position sensitive photo-multipliers. The lead collimator features parallel hexagonal 1.0 mm holes, 18 mm length, 0.2 mm septa and 10x10 cm{sup 2} detection area. It was newly designed to fully exploit the high spatial resolution a Lanthanum crystal may provide. To better evaluate its role, we have compared our camera to three other systems with similar crystals and photomultipliers, but employing traditional collimators, either pinhole or parallel. The new camera seems to be complementary to pinhole systems and shows a very attractive trade-off between spatial resolution and detection area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-A-9A-05: First Experimental Demonstration of the Anisotropic Detection Principle in X-Ray Fluorescence Computed Tomography

Purpose: To improve the sensitivity of X-ray fluorescence computed tomography (XFCT) for in vivo molecular imaging. Is the maximum sensitivity achieved with an isotropic (4π) detector configuration? We prove that this is not necessarily true, and that a greater sensitivity is possible with anisotropic detector configuration. Methods: An XFCT imaging system was constructed consisting of 1) a collimated pencil beam x-ray source using a fluoroscopy grade x-ray tube; 2) a CdTe x-ray photon counting detector to detect fluorescent x-rays; and 3) a rotation/translation stage for tomographic imaging. We created a 6.5-cm diameter water phantom with 2-cm inserts of low gold concentration (0.25%–1%) to simulate tumors targeted by gold nano-particles. The placement of x-ray fluorescence detector were chosen to minimize scatter x-rays. XFCT imaging was performed at three different detector positions (60°, 90°, 145°) to determine the impact of forward-scatter, side-scatter, and back-scatter on imaging performance. The three data sets were also combined to estimate the imaging performance with an isotropic detector. Results: The highest imaging performance was achieved when the XF detector was in the backscatter 145° configuration. The signal-to-noise ratio (SNR) was 5.5 for the 0.25% gold concentration compared to SNRs of 1.4, 0, and 2.4 for 60°, 90°, and combined (60°+90°+145°) datasets. Only the 145° detector arrangement alone could detect the 0.25% concentration. The imaging dose was 14 mGy for each detector arrangement experiment. Conclusion: This study experimentally proves, for the fist time, the Anisotropic Detection Principle in XF imaging, which holds that optimized anisotropic x-ray fluorescence detection provides greater sensitivity than isotropic detection. The optimized detection arrangement was used to improve the sensitivity of the XFCT experiment. The achieved XFCT sensitivity is the highest ever for a phantom at least this large using a benchtop x-ray source, which is an important step toward clinical XFCT molecular imaging. This work was supported by the NCI fellowship grant R25T-CA118681 and by the NIH (1R01-EB016777) and NIBIB (1K99-EB016059)

60 APPLIED LIFE SCIENCES↗

Large-volume protein crystal growth for neutron macromolecular crystallography

Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for the growth of crystals to significant dimensions that are now relevant to NMC are revisited. We report that these include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulations of the LHC high luminosity monitors at beam energies from 3.5 TeV to 7.0 TeV

We have constructed two pairs of fast ionization chambers (BRAN) for measurement and optimization of luminosity at IR1 and IR5 of the LHC. These devices are capable of monitoring the performance of the LHC at low luminosity 10{sup 28} cm{sup -2}s{sup -1} during beam commissioning all the way up to the expected full luminosity of 10{sup 34} cm{sup -2}s{sup -1} at 7.0 TeV. The ionization chambers measure the intensity of hadronic/electromagnetic showers produced by the forward neutral particles of LHC collisions. To predict and improve the understanding of the BRAN performance, we created a detailed FLUKA model of the detector and its surroundings. In this paper, we describe the model and the results of our simulations including the detector's estimated response to pp collisions at beam energies of 3.5, 5.0, and 7.0 TeV per beam. In addition, these simulations show the sensitivity of the BRAN to the crossing angle of the two LHC beams. It is shown that the BRAN sensitivity to the crossing angle is proportional to the measurement of crossing angle by the LHC beam position monitors.

43 PARTICLE ACCELERATORS↗

Distribution of Pb-210 in Spanish Soils: Study of the Atmospheric Contribution

The vertical distribution of activity and inventories of atmospheric Pb-210 is being studied in Spanish soils, aiming to establish the reference levels in the zone, based on the type of soil and the annual rainfall. A homogeneous distribution grid (approx. 150x150 km each cell) has been established covering the peninsular land, trying to combine the varying soil types (remaining undisturbed for the last 50 years) and the closeness to meteorological stations. Sampling has been performed by extracting undisturbed soil cylinders of 6 cm diameter and 120 cm length, with an impact penetrometer, and the soil cores have been sectioned in slices of 3 cm thick. The analysis of Pb-210 has been performed using a gamma spectrometry system with coaxial HPGe detector sensitive at low energies (46.5 keV emission). The geometry of measured samples is thin enough (approx. 2 cm) to minimize self-absorption corrections. The work presents the results obtained so far. The Pb-210 activity profiles exhibit the characteristic decreasing shape with depth, showing maximum levels at the surface, and reaching the equilibrium activity with Ra-226 at a maximum depth depending on different environmental conditions. The unsupported Pb-210 inventory values are in the usual range (1000-5000 Bq/m{sup 2}), showing a positive correlation with the averaged annual rainfall. These reference levels could be used in posterior studies of anthropogenic alteration of soils, evaluation of erosion and desertification processes.

54 ENVIRONMENTAL SCIENCES↗

Maximum likelihood positioning algorithm for high-resolution PET scanners

Purpose: In high-resolution positron emission tomography (PET), lightsharing elements are incorporated into typical detector stacks to read out scintillator arrays in which one scintillator element (crystal) is smaller than the size of the readout channel. In order to identify the hit crystal by means of the measured light distribution, a positioning algorithm is required. One commonly applied positioning algorithm uses the center of gravity (COG) of the measured light distribution. The COG algorithm is limited in spatial resolution by noise and intercrystal Compton scatter. The purpose of this work is to develop a positioning algorithm which overcomes this limitation. Methods: The authors present a maximum likelihood (ML) algorithm which compares a set of expected light distributions given by probability density functions (PDFs) with the measured light distribution. Instead of modeling the PDFs by using an analytical model, the PDFs of the proposed ML algorithm are generated assuming a single-gamma-interaction model from measured data. The algorithm was evaluated with a hot-rod phantom measurement acquired with the preclinical HYPERION II {sup D} PET scanner. In order to assess the performance with respect to sensitivity, energy resolution, and image quality, the ML algorithm was compared to a COG algorithm which calculates the COG from a restricted set of channels. The authors studied the energy resolution of the ML and the COG algorithm regarding incomplete light distributions (missing channel information caused by detector dead time). Furthermore, the authors investigated the effects of using a filter based on the likelihood values on sensitivity, energy resolution, and image quality. Results: A sensitivity gain of up to 19% was demonstrated in comparison to the COG algorithm for the selected operation parameters. Energy resolution and image quality were on a similar level for both algorithms. Additionally, the authors demonstrated that the performance of the ML algorithm is less prone to missing channel information. A likelihood filter visually improved the image quality, i.e., the peak-to-valley increased up to a factor of 3 for 2-mm-diameter phantom rods by rejecting 87% of the coincidences. A relative improvement of the energy resolution of up to 12.8% was also measured rejecting 91% of the coincidences. Conclusions: The developed ML algorithm increases the sensitivity by correctly handling missing channel information without influencing energy resolution or image quality. Furthermore, the authors showed that energy resolution and image quality can be improved substantially by rejecting events that do not comply well with the single-gamma-interaction model, such as Compton-scattered events.

60 APPLIED LIFE SCIENCES↗

Analysis of Polarimetry Data with Angular Uncertainties

For a track based polarimeter, such as the Imaging X-ray Polarimetry Explorer (IXPE), the sensitivity to polarization depends on the modulation factor, which is a strong function of energy. In previous work, a likelihood method was developed that would account for this variation in order to estimate the minimum detectable polarization (MDP). That method essentially required that the position angles of individual events should be known precisely. In a separate work, however, it was shown that using a machine-learning method for measuring event tracks can generate track angle uncertainties, which can be used in the analysis. Here, the maximum likelihood method is used as a basis for revising the estimate of the MDP in a general way that can include uncertainties in event track position angles. The resultant MDP depends solely upon the distribution of track angle uncertainties present in the input data. Due to the physics of the IXPE detectors, it is possible to derive a simple relationship between these angular uncertainties and the energy-dependent modulation function as a step in the process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose homogeneity specification for reference dosimetry of nonstandard fields

Purpose: To investigate the sensitivity of the plan-class specific correction factor to dose distributions in composite nonstandard field dosimetry. Methods: A cylindrical water-filled PMMA phantom was constructed at the center of which reference absorbed dose could be measured. Ten different TomoTherapy-based IMRT fields were created on the CT images of the phantom. The dose distribution for each IMRT field was estimated at the position of a radiation detector or ionization chamber. The dose in each IMRT field normalized to that in a reference 10 x 10 cm{sup 2} field was measured using a PTW micro liquid ion chamber. Based on the new dosimetry formalism, a plan-class specific correction factor k{sub Q{sub p{sub c{sub s{sub r,Q}{sup f{sub p}{sub c}{sub s}{sub r},f{sub r}{sub e}{sub f}}}}}} for each field was measured for two Farmer-type chambers, Exradin A12 and NE2571, as well as for a smaller Exradin A1SL chamber. The dependence of the measured correction factor on parameters characterizing dose distribution was analyzed. Results: Uncertainty on the plan-class specific correction factor measurement was in the range of 0.3%-0.5% and 0.3%-0.8% for the Farmer-type chambers and the Exradin A1SL, respectively. When the heterogeneity of the central region of the target volume was less than 5%, the correction factor did not differ from unity by more than 0.7% for the three air-filled ionization chambers. For more heterogeneous dose deliveries, the correction factor differed from unity by up to 2.4% for the Farmer-type chambers. For the Exradin A1SL, the correction factor was closer to unity due to the reduced effect of dose gradients, while it was highly variable in different IMRT fields because of a more significant impact of positioning uncertainties on the response of this chamber. Conclusions: The authors have shown that a plan-class specific correction factor can be specified as a function of plan evaluation parameters especially for Farmer-type chambers. This work provides a recipe based on quantifying dose distribution to accurately select air-filled ionization chamber correction factors for nonstandard fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atmospheric {sup 41}Ar Plume Tracking of the UF Training Reactor Using a Large-Volume NaI Detector

The ability to track and monitor gaseous radioactive materials is important in the event of a radioactive release such as from a nuclear power plant accident, weapons testing, or other unintended release scenarios. The International Monitoring System (IMS) is currently in place to monitor for weapons testing and has been used to monitor nuclear power plant accidents. However, only 80 radionuclide stations for the IMS exist in the world and are stationary, limiting the resolution of any radioactive plumes detected. Furthermore, the IMS radionuclide stations are designed to be sensitive specifically to atmospheric radio-xenon and no other radionuclides. Historically, monitoring radioactive releases has been limited to the detection of radio-xenon and radio-krypton, both arising as fission products from nuclear fuel. After the accident at Three Mile Island Unit 2, scientists were interested in finding the dose the public received from released radioactive material. This was achieved by analyzing radiation monitors in the exhaust stack and filters within the reactor building. furthermore, a series of 20 thermoluminescent dosimeters (TLD's), 8 air sampling station positioned around Three Mile Island, and a helicopter survey which used a NaI(Tl) detector array provided data on radionuclides, specifically {sup 137}Cs, that escaped the confines of the reactor building. The TLD's and air sampling stations were stationary, and therefore limited the resolution of the radioactive release plume. The helicopter survey using the NaI detectors was limited by the technology available at the time. The NaI detector array output was compressed from 1024 channels to 256 channels, limiting the energy resolution of the spectral data. The helicopter used a microwave ranging system to establish position. Since this survey was taken in October of 1982, advancements in technology allow spectral data to be saved in its full 1024 channel format and the advent of GPS can give a more accurate account of the detector position. An updated mobile system for tracking a radioactive release would help to alleviate these issues as well as gain the ability to track a radioactive release in real-time. We investigate the feasibility of mobile tracking through study and measurement of the {sup 41}Ar plume released from the University of Florida Training Reactor (UFTR) research reactor. We use a large-volume NaI(Tl) detector placed on the roof near the reactor. This detector may also be placed and moved on a cart to survey the area surrounding the reactor. We compare the spectral data taken when the reactor is running at full power to the background to analyze the effectiveness of the detector at identifying atmospheric {sup 41}Ar. Finally we discuss the implications of these measurements with regards to validation of plume models and the capability to track releases over a localized area from the source. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing General Relativity in Fermilab

Modern theories of the fundamental particles and the interactions among them have achieved a simple and coherent description of an unprecedented range of natural phenomena, but our new understanding raises intriguing new questions. Though there is a growing confidence in our ability to unify electroweak and strong interactions in a single gauge theory, gravity remains widely separated from the particle physics. In fact, road to a correct description of quantum gravity depends crucially on if experimental search methods end up with a negative or positive answer for the presence of higher-curvature space-time dimensions. Our theoretical study of general-relativistic gravitational force generated by a 1 Tev bunch of protons at Fermilab Tevatron accelerator demonstrates that the force has many similarities with the synchrotron radiation, and is in the range of sensitivity of modern low-frequency (torsion balance-type) detectors. Its measurement may open new fascinating opportunities for experimental study of the unification of gravity with other fundamental interactions presumably including the string theory.

43 PARTICLE ACCELERATORS↗

Flux Measurement at a Neutrino Factory Near Detector for Neutrino Oscillations

It is well established that a Near Detector positioned within 1 km of the muon decay pipe at a Neutrino Factory is essential for a true determination of the neutrino flux, necessary for the neutrino oscillation signal. Here we present a method for the the extraction of the oscillation probability parameters using the Near Detector, in combination with a long baseline Far Detector and demonstrate that by using this method, the sensitivity to oscillation parameters is maintained down values of {theta}{sub 13} one order of magnitude lower than the current world limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗