Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Mark III very long baseline interferometry positions of eight stellar systems and astrometric comparisons

Accurate positions of eight stellar systems have been obtained from Mark III VLBI observations performed with multistation arrays, and the quality of the celestial frames used by different techniques is compared. The satisfactory agreement found between VLBI and optical positions indicates that the preliminary FK5 optical frame defined by Fricke (1982) is aligned with the VLBI extragalactic reference frame. The VLBI and VLA right ascensions agree, while a large discrepancy is noted between the VLBI and VLA declinations.

Lestrade, Jean-Francois↗

Effect of the Trendelenburg position on the distribution of arterial air emboli in dogs

The effect of Trendelenburg position (TP) on the distribution of arterial air emboli in dogs was examined in a two-part investigation. In the first part, the effects of the bubble size and the vessel angle on the bubble velocity and the direction of flow were investigated in vitro, using a simulated carotid artery preparation. It was found that larger bubbles increased in velocity in the same direction as the blood flow at 0-, 10-, and 30-deg vessel angles, and decreased when the vessel was positioned at 90 deg. Smaller bubbles did not change velocity from 0 to 30 deg, but acted to increase the velocity, in the same direction as the flood flow, at 90 deg. The second series of experiments examined the effect of 0 to 30 deg TP on carotid-artery distribution of gas bubbles injected into the left ventricle or ascending aorta of anesthetized dogs. It was found that, regardless of the degree of the TP, the bubbles passed into the carotid artery simultaneously with the passage into the abdominal aorta. It is concluded that the TP does not prevent arterial bubbles from reaching the brain.

Butler, Bruce D.↗

Improvements to an electromagnetic position sensor for a magnetic suspension wind tunnel

The original and improved designs for the Electromagnetic Position Sensor (EPS), an electronic instrument and associated multicoil sensor for the six-inch Magnetic Suspension and Balance System (MSBS) that measures aerodynamic model position, are compared. The EPS power amplifier and oscillator, input nulling stage, reference voltage generators, bandpass filter, summation and demodulation, and final stage are described. The effects of the MSBS and of model materials on the performance are addressed.

Daniels, Taumi S.↗

Position sensitivity of MAMA detectors

The results of laboratory and telescopic measurements of the position sensitivity of a visible MAMA detector utilizing a 'coarse-fine' array are presented. The photometric accuracy of this detector was determined under point source illumination. It was found that computed centroid positions are accurate across the entire array to within 0.04 pixels.

Morgan, J. S.↗

Centroid position measurements and subpixel sensitivity variations with the MAMA detector

Initial measurements of the position sensitivity of a visible-light multianode microchannel array detector show that centroid calculations for image spots are accurate to better than 0.04 pixels even with sources that are essentially delta functions at the photocathode.Subpixel sensitivity variations of 10-15 percent are typically found for pixels in the array. Variations as large as 30 percent are possible in the worst conditions. These variations limit the photometric accuracy of the detector when very small scale features are observed. The photometric accuracy and the position sensitivity of the detector appear to be limited by cross-coupling effects within the anode array. Initial measurements with more recent designs of the detector show that most or all of this cross-coupling has been eliminated.

Morgan, Jeffrey S.↗

Equilibrium shape and location of a liquid drop acoustically positioned in a resonant rectangular chamber

The effect of a standing wave field in a rectangular chamber on the shape and location of an acoustically positioned drop or bubble is calculated. The sample deformation and equilibrium position are obtained from an analysis of the spherical harmonic projections of the total surface stress tensor. The method of calculation relies on the assumed condition that the sample is only slightly distorted from a spherical form. The equilibrium location of a levitated drop is combined with a formula introduced by Hasegawa (1979) to calcualte the ka dependence of the radiation force function. The present theory is valid for large as well as small ka values. Calculations in the small ka limit agree with previous theories and experimental results. Examples are presented for nonplane-wave modes as well as plane-wave rectangular modes.

Jackson, H. W.↗

Positioning X-Ray Film With String And Magnets

Technique devised to position x-ray film in normally inaccessible places for inspection of welded joints. Lead/magnet markers and string attached to ends of strips of x-ray film to facilitate positioning. Fewer shots required than in random trial-and-error sequence, and resulting images more accurate.

Larosa, William D.↗

Tests Of A Differential Global Positioning System

Paper describes validation tests of global positioning system (GPS) for low-flying helicopters. Configured as differential GPS, in which components in both aircraft and ground station compute position errors relative to known location using satellite navigational data. Corrections computed from differences between computed and measured ranges to four satellites being tracked by receiver in both aircraft and ground systems. Tests conducted to determine whether equipment and computer programs of system operated correctly and consistently.

Edwards, F. G.↗

Simple Regulator For Positive-Pressure Glove Box

Weighted, inflated bag regulates pressure in positive-pressure glove box such as those used to manipulate samples in atmosphere isolated from such contaminations in open air as moisture or oxygen. Weight atop the inflated bag rises and falls as gas flows into and out of bag from glove box. Positive pressure relative to surroundings pushes gloves outward when not being used. To manipulate items in box, technician forces gloves inside. Sensitive materials manipulated in dry or inert atmosphere without danger of overpressure when technician inserts hands in gloves, or of underpressure - and inward leakage of air - when technician draws hands out of gloves. Replaces elaborate system of pressure-activated valves. Quieter, cheaper, and more reliable.

Shlichta, Paul J.↗

Optical techniques for determination of normal shock position in supersonic flows for aerospace applications

Techniques for the quantitative determination of shock position in supersonic flows using direct and indirect methods is presented. A description of an experimental setup is also presented, different configurations of shock position sensing systems are explained, and some experimental results are given. All of the methods discussed are analyzed to determine the ease of technology transfer from the laboratory to in-flight operation.

Adamovsky, Grigory↗

Reanalysis and confirmation of positive latitude gradients for anomalous helium and Galactic cosmic rays measured in 1975-1976 with Pioneer II

Reanalysis of the 1975-1978 observations from Pioneer 10, Pioneer 11, and IMP 8 confirm earlier reports of a positive latitude gradient during this period for low-energy anomalous helium and, possibly, for low-energy Galactic protons. The observations are most consistent with an intensity distribution that is asymmetric with respect to the heliographic equatorial plane, rather than symmetric, as had been assumed in the earlier reports, and as would be most naturally consistent with currently available models for the solar modulation. Attempts to relate the intensity to the relative positions of the spacecraft with respect to the interplanetary equatorial neutral sheet yield no improvement in the organization of the data.

Mckibben, R. B.↗

A novel sample-positioning system for microgravity application

This paper proposes a novel method for sample positioning in containerless processing at microgravity, using a system based on pulsed lasers. The method has two attributes. First, by generating beams that cancel out vectorially, the suspended material can be heated without being accelerated, a feature that can be used in melting and heat-treatment applications. Second, the specimen can be positioned within a fairly large work space. It is emphasized that this method can service a regime unfulfilled by the other levitation methods, such as electromagnetic levitation, active magnetic suspension, acoustic levitation, of electrostatic suspension.

Sridharan, G.↗

Reinforced Positive Filler Paste For Lead/Acid Batteries

Lead-coated glass fibers extend battery life. Mixture of lead-coated glass fibers and positive paste form pellets of active material between grid wires of positive battery electrode. Fibers contribute to charge capacity, electrical conductivity, and mechanical stability of electrode.

Edwards, Dean B.↗

Improved Rotary Transformer For Shaft-Position Indicator

Improved rotary transformer for Inductosyn (or equivalent) shaft-position-indicating circuit has pair of ferrite cores instead of the solid-iron cores. Designed with view toward decreasing excitation power (to maximum allowable 2 W) supplied to shaft-position-indicating circuit to increase its output signal and make tracking system less vulnerable to electromagnetic interference.

Mclyman, W. T.↗

A computer model of the electrostatic positioning system

Positioning systems based upon electrstatic forces are being developed for the containerless processing of materials that cannot use acoustic or electromagnetic positioning techniques. Currently, electrode configurations for these electrostatic systems are designed on the basis of approximate analytical calculations and past experience. A three dimensional computer model is being developed that will predict the electrostatic fields and forces for a given electrode configuration and will allow for a more rapid evaluation of proposed designs. Early results of this model are presented.

Gutt, G. M.↗

Some considerations for various positioning systems and their science capabilities

Containerless processing of materials at elevated temperatures is discussed with emphasis on high temperature chemistry, thermophysical properties, materials science, and materials processing. Acoustic and electromagnetic positioning of high temperature melts are discussed. Results from recent ground based experiments, including KC-135 testing of an acoustic levitator, are presented. Some current positioning technologies and the potential for enhancing them are considered. Further, a summary of these technologies and their science capabilities for the development of future experiments is given.

Rey, Charles A.↗

Large scale motions of Neptune's bow shock: Evidence for control of the shock position by the rotation phase of Neptune's magnetic field

The Voyager 2 spacecraft observed high levels of Langmuir waves before the inbound crossing of Neptune's bow shock, thereby signifying magnetic connection of the bow shock. The Langmuir waves occurred in multiple bursts throughout two distinct periods separated by an 85 minute absence of wave activity. The times of onsets, peaks, and disappearances of the waves were used together with the magnetic field directions and spacecraft position, to perform a 'remote-sensing' analysis of the shape and location of Neptune's bow shock prior to the inbound bow shock crossing. The bow shock is assumed to have a parabolidal shape with a nose location and flaring parameter determined independently for each wave event. The remote-sensing analysis give a shock position consistent with the time of the inbound shock crossing. The flaring parameter of the shock remains approximately constant throughout each period of wave activity but differs by a factor of 10 between the two periods. The absence of waves between two periods of wave activity coincides with a large rotation of the magnetic field and a large increase in the solar wind ram pressure' both these effects lead to magnetic disconnection of the spacecraft from shock. The planetwards motion of the shock's nose from 38.5 R(sub N) to 34.5 R(sub N) during the second time period occurred while the solar wind ram pressure remained constant to within 15 percent. This second period of planetwards motion of the shock is therefore strong evidence for Neptune's bow shock moving in response to the rotation of Neptune's oblique, tilted magnetic dipole. Normalizing the ram pressure, the remotely-sensed shock moves sunwards during the first wave period and planetwards in the second wave period. The maximum standoff distance occurs while the dipole axis is close to being perpendicular to the Sun-Neptune direction. The remote-sensing analysis provides strong evidence that the location of Neptune's bow shock is controlled by Neptune's rotation phase.

Cairns, Iver H.↗

Laser optical disk position encoder with active heads

An angular position encoder that minimizes the effects of eccentricity and other misalignments between the disk and the read stations by employing heads with beam steering optics that actively track the disk in directions along the disk radius and normal to its surface is discussed. The device adapts features prevalent in optical disk technology to the application of angular position sensing.

Osborne, Eric P.↗