Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power System Dynamics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dynamic RPS Path to Flight - Nuclear and Emerging Technologies for Space

NASA Glenn Research Center has been pursuing the development of dynamic power conversion for several decades. Candidate NASA missions involve mutli-year travel to far away destinations, or to extreme environments where sunlight does not exist. Human-base mission studies also show that power needs would be beyond the capabilities of solar energy conversion, and instead would require nuclear reactor energy sources, for which the thermal energy must be converted to electricity. Dynamic power conversion technology has developed sufficiently to make a sound engineering argument that it is suitable for these NASA missions. Dynamic conversion power sources have yet to be flown in space, and thus suffer a disadvantage owing to their lack of heritage data on flight missions. One of the largest obstacles for adoption is the uncertainty in reliability of a device with moving parts. However, significant progress has been made toward demonstrating the technology capable in all relevant environments, with the necessary long life. Another hurdle for adoption is the lack of mission, which would drive specific requirements, and provide a solid timeline for technology development endpoint. Until a mission is identified, an alternative approach is necessary to advance a dynamic power conversion system towards flight.

Oriti, Salvatore↗

SMD Technology Highlights

Two technology highlights from the Science Mission Directorate (SMD) Planetary Science Division and Biological and Physical Sciences division are featured: a) The Dynamic Radioisotope Power Systems Project (DRPS) may enable lunar science payloads to survive and thrive during the harsh lunar night. New robust DRPS have been built and delivered by industry and are in the process of being tested at NASA’s Glenn Research Center. b) NASA's Plant Water Management (PWM) project is demonstrating that even without the help of gravity, hydroponic plant watering methods can enable plant habitats aboard crewed or robotic space missions. On Earth, plants draw water upwards through the roots against gravity, via capillary action, which orients the plant and enables display of its canopy (foliage and branches) for optimal photosynthesis and transpiration. The plant grows above the nutrient-rich soil as the water U.S. Astronaut Kate Rubins poses with PWM after nearly doubling the science returns of the ISS experiment by drawing on her wealth of wet lab operations and handling experience—on Earth and in space.

RPS↗

On the Feasibility of Dynamic Power Steering

While high performance has always been the primary constraint behind large-scale system design, future systems will be built with increasing energy efficiency in mind. Mechanisms such as fine-grained power scaling and gating will provide tools to system-software and application developers to ensure the most efficient use of tightly constrained power budgets. Such approaches to-date have been focused on node level optimizations to impact overall system energy efficiency. In this work we introduce Dynamic Power Steering, in which power can be dynamically routed across a system to resources where it will be of most benefit and away from other resources to maintain a near-constant overall power budget. This, a higher level algorithmic approach to improving energy efficiency, considers the whole extent of a system being used by an application. It can be used for applications in which there is load imbalance that varies over its execution. Using two classes of applications, namely those that contain a wave front type processing, and a particle-in-cell, we quantify the benefit of Dynamic Power Steering for a variety of workload characteristics and derive some insight into the ways in which workload behavior affect Power Steering applicability.

Barker, Kevin J.↗

Stabilizing Inverter-Based Transmission Systems: Power Hardware-in-the-Loop Experiments with a Megawatt-Scale Grid-Forming Inverter

This article presents what the authors believe to be the first experimental verification of the ability of grid-forming (GFM) inverters to stabilize a transmission electric power system that is otherwise unstable. The experiments described here were performed using power hardware-in-the-loop (PHIL) simulation to connect a megawatt-scale battery inverter to a real-time electromagnetic transient (EMT) simulation of the near-future Maui power system. This allows the dynamic interactions between the inverter and the power system to be observed without putting the real power system at risk. The ability to use the actual inverter hardware removes the need to rely on a computer model approximation of the inverter's behavior.

electromagnetic transient simulations↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Theoretical Solid Oxide Fuel Cell Model for System Controls and Stability Design

As the aviation industry moves towards higher efficiency electrical power generation, all electric aircraft, or zero emissions and more quiet aircraft, fuel cells are sought as the technology that can deliver on these high expectations. The Hybrid Solid Oxide Fuel Cell system combines the fuel cell with a microturbine to obtain up to 70 percent cycle efficiency, and then distributes the electrical power to the loads via a power distribution system. The challenge is to understand the dynamics of this complex multi-discipline system, and design distributed controls that take the system through its operating conditions in a stable and safe manner while maintaining the system performance. This particular system is a power generation and distribution system and the fuel cell and microturbine model fidelity should be compatible with the dynamics of the power distribution system in order to allow proper stability and distributed controls design. A novel modeling approach is proposed for the fuel cell that will allow the fuel cell and the power system to be integrated and designed for stability, distributed controls, and other interface specifications. This investigation shows that for the fuel cell, the voltage characteristic should be modeled, but in addition, conservation equation dynamics, ion diffusion, charge transfer kinetics, and the electron flow inherent impedance should also be included.

Kopasakis, George↗

Dynamic Parameter Estimation with Physics-based Neural Ordinary Differential Equations

Accurate estimation of dynamic parameters of gen-erators is crucial to building a reliable model for dynamical studies and reliable operation of the power system. This paper develops a physics-based neural ordinary differential equations (ODE) approach to learn the parameters of generator dynamic model using phasor measurement units (PMU) data. We design a physics-based neural network to represent the swing equations of the power system dynamics. A loss function is defined as the difference between dynamic simulation results from the physics-based neural networks and pseudo PMU measurements. The parameters of generator dynamic model are iteratively updated using the neural ODEs and the adjoint method. By exploiting the mini-batch scheme in neural ODE training, the parameter estimation performance is significantly improved. Numerical study results on a 3-machine 9-bus system show that the proposed algorithm outperforms state-of-the-art baseline method in both computation time and dynamic parameter estimation accuracy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Theoretical Solid Oxide Fuel Cell Model for Systems Controls and Stability Design

As the aviation industry moves toward higher efficiency electrical power generation, all electric aircraft, or zero emissions and more quiet aircraft, fuel cells are sought as the technology that can deliver on these high expectations. The hybrid solid oxide fuel cell system combines the fuel cell with a micro-turbine to obtain up to 70% cycle efficiency, and then distributes the electrical power to the loads via a power distribution system. The challenge is to understand the dynamics of this complex multidiscipline system and the design distributed controls that take the system through its operating conditions in a stable and safe manner while maintaining the system performance. This particular system is a power generation and a distribution system, and the fuel cell and micro-turbine model fidelity should be compatible with the dynamics of the power distribution system in order to allow proper stability and distributed controls design. The novelty in this paper is that, first, the case is made why a high fidelity fuel cell mode is needed for systems control and stability designs. Second, a novel modeling approach is proposed for the fuel cell that will allow the fuel cell and the power system to be integrated and designed for stability, distributed controls, and other interface specifications. This investigation shows that for the fuel cell, the voltage characteristic should be modeled but in addition, conservation equation dynamics, ion diffusion, charge transfer kinetics, and the electron flow inherent impedance should also be included.

Kopasakis, George↗

Sensitivity Analysis of Compensation Topologies for Dynamic WPT System

The dynamic wireless power transfer (DWPT) or in-motion charging of electric vehicles (EVs) may alleviate the challenges encountered by the plug-in charging systems and assist in the penetration of the EVs at a larger scale. Similar to its stationary charging counterpart, DPWT also makes use of compensation circuits to reduce the inductive reactance for enabling higher current on the coupler winding and improve the power transfer. However, the behavior of compensation circuits has not been comprehensively analyzed in a DWPT system. This paper analyzes in detail the performance of three compensation topologies applied to the DWPT system. A combination of finite element analysis (FEA) and circuit analysis is employed to study the compensation topologies when the receiving coil moves over the transmitting coil. Moreover, the variations in operating frequency have also been considered in the analysis. Furthermore, the theoretical calculations for the dynamic WPT system are verified using PLECS simulation model.

Haruna, Josiah↗

Indicator-directed Dynamic Power Management for Iterative Workloads on GPU-Accelerated Systems

Modern high-performance and warehouse computing centers show strong interest in minimizing system power consumption while satisfying customers’ quality of service (QoS). Dynamic voltage and frequency scaling (DVFS) is effective for achieving this goal. Nevertheless, automating the process online and making it transparent to users must address three major challenges: (1) Complexity — today’s hardware components (e.g., CPUs, GPUs, memory, network, etc.) can be configured in several or dozens of frequency/voltage states for satisfying divergent system demands. Given their combination and the emergence of heterogeneity, searching the optimal configuration in the design space online can be timing consuming. (2) QoS guarantee — user-defined objectives such as power constraint and performance target must be monitored, predicted and ensured at the best effort. (3) Adaptability — various known and unknown workloads run on systems. Workloads characteristics should be quickly determined and configurations dynamically adjusted in accord with workloads and QoS. In this work, we focus on applications exhibiting an interesting feature – iterative or periodic, which is common among conventional HPC and emerging machine learning workloads. We propose an online dynamic power-performance (ODPP) management framework to dynamically adjust GPU DVFS configurations to meet performance and power objectives and constraints, without any code annotation or intrusion. Particularly, ODPP extracts the performance and power indicators for applications from their resources utilization profiles in a short episode. It further automatically constructs an accurate model that infers from the indicators how the application's performance and power vary with GPU core and memory frequencies. Aided with the model, for both seen and unseen applications, ODPP can quickly determine the most appropriate DVFS configuration for their execution. We evaluate ODPP on an NVIDIA GPU using multiple exascale computing (ECP) and deep learning applications.

Zou, Pengfei↗

Data Projection of the High Temperature Electrolysis System in the Dynamic Energy Transport and Integration Laboratory using Dynamic System Scaling

For nuclear power to be flexible in a functioning Integrated Energy System (IES), excess produced heat must be stored or utilized during times of low power demand to ensure a load factor of 1 while load balancing. The Dynamic Energy Transport and Integration Laboratory (DETAIL) is one facility that is under development to emulate IES conditions on the engineering-scale, planned to conduct virtual real time operations with industry-scale facilities, and is currently testing thermal storage and high temperature electrolysis. As part of the study to develop a method to preprocess input signals or postprocess output signals between systems of different scales via Dynamical System Scaling (DSS), the current research is one of the continued efforts branching from the data projection activity conducted for the Thermal Energy Distribution System and currently engages the High Temperature Electrolysis (HTE) System in DETAIL. The HTE SOEC electrical, fluid, and thermal dynamics Figure of Merits (FOM) were identified, governing equations and closure relations were successfully scaled, and relations between FOM scaling ratios were determined. Setting the scaling objectives to reform existing data to project a data set that doubly accelerated the electrolysis process while preserving the produced amount of hydrogen was generated for the full transient. The calculated boundary conditions were inlet temperature, stack current, and inlet steam mass flow rate at 1470 K, 121.1 A, and 1.886 g/s, respectively. The research outcomes demonstrated an output signal postprocessing case accelerating the hydrogen production without changing geometry, number of cells, and partial pressures.

08 HYDROGEN↗

Advanced High-Temperature Reactor Dynamic System Model Development: April 2012 Status

The Advanced High-Temperature Reactor (AHTR) is a large-output fluoride-salt-cooled high-temperature reactor (FHR). An early-phase preconceptual design of a 1500 MW(e) power plant was developed in 2011 [Refs. 1 and 2]. An updated version of this plant is shown as Fig. 1. FHRs feature low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. The AHTR is designed to be a “walk away” reactor that requires no action to prevent large off-site releases following even severe reactor accidents. This report describes the development of dynamic system models used to further the AHTR design toward that goal. These models predict system response during warmup, startup, normal operation, and limited off-normal operating conditions. Severe accidents that include a loss-of-fluid inventory are not currently modeled. The scope of the models is limited to the plant power system, including the reactor, the primary and intermediate heat transport systems, the power conversion system, and safety-related or auxiliary heat removal systems. The primary coolant system, the intermediate heat transport system and the reactor building structure surrounding them are shown in Fig. 2. These systems are modeled in the most detail because the passive interaction of the primary system with the surrounding structure and heat removal systems, and ultimately the environment, protects the reactor fuel and the vessel from damage during severe reactor transients. The reactor silo also plays an important role during system warmup. The dynamic system modeling tools predict system performance and response. The goal is to accurately predict temperatures and pressures within the primary, intermediate, and power conversion systems and to study the impacts of design changes on those responses. The models are design tools and are not intended to be used in reactor qualification. The important details to capture in the primary system relate to flows within the reactor vessel during severe events and the resulting temperature profiles (temperature and duration) for major components. Critical components include the fuel, reactor vessel, primary piping, and the primary-to-intermediate heat exchangers (P-IHXs). The major AHTR power system loops are shown in Fig. 3. The intermediate heat transfer system is a group of three pumped salt loops that transports the energy produced in the primary system to the power conversion system. Two dynamic system models are used to analyze the AHTR. A Matlab/Simulink-based model initiated in 2011 has been updated to reflect the evolving design parameters related to the heat flows associated with the reactor vessel. The Matlab model utilizes simplified flow assumptions within the vessel and incorporates an empirical representation of the Direct Reactor Auxiliary Cooling System (DRACS). A Dymola/Modelica model incorporates a more sophisticated representation of primary coolant flow and a physics-based representation of the three-loop DRACS thermal hydraulics. This model is not currently operating in a fully integrated mode. The Matlab model serves as a prototype and provides verification for the Dymola model, and its use will be phased out as the Dymola model nears completion. The heat exchangers in the system are sized using spreadsheet-based, steady-state calculations. The detail features of the heat exchangers are programmed into the dynamic models, and the overall dimensions are used to generate realistic plant designs. For the modeling cases where the emphasis is on understanding responses within the intermediate and primary systems, the power conversion system may be modeled as a simple boundary condition at the intermediate-to-power conversion system heat exchangers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Study of the Impact of Reduced Inertia in Power Systems

Inertia in power systems plays an important role in maintaining the stability and reliability of the system by counteracting changes in frequency. However, the traditional sources of synchronous generation are being displaced by renewable resources, which often have no inherent inertia. This paper investigates the impact of reduced system inertia on several aspects of the dynamic stability of power systems, such as angular stability, primary frequency response, and oscillatory modes. This study is performed on a large-scale 2000 bus synthetic Texas model by selectively replacing synchronous generators with inverter-based generation resources. This paper also compares the analysis results obtained by the above-mentioned inertia-reduction approach of renewable integration with another approach in which the inertia constant of all synchronous generators is decreased. This paper demonstrates that only reducing the inertia of all synchronous generators in a system does not provide an accurate analysis of the challenges associated with the reduced system inertia caused by renewable integration.

System Inertia, Angular stability, System Inertial↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗

Simulation and dynamic performance of a 20-kHz spacecraft power system

A candidate 20-kHz spacecraft power system which includes a series-parallel combination of four Mapham inverters connected to several types of loads is described. A computer simulation of the power system is used to illustrate its steady-state and dynamic performance on an end-to-end basis. Comparisons with measured data are made. It is shown that significant distortion of the 20-kHz bus voltage can occur due to the switching of the load converters. This distortion can be reduced by including a shunt-connected parallel resonant filter on the 20-kHz side of the load converter. It is also shown that the distortion can be reduced by using a pulse-density-modulated switching strategy.

Wasynczuk, O.↗

Performance of Three Mode-Meter Block-Processing Algorithms for Automated Dynamic Stability Assessment

The frequency and damping of electromechanical modes offer considerable insight into the dynamic stability properties of a power system. The performance properties of three block-processing algorithms from the perspective of near real-time automated stability assessment are demonstrated and examined. The algorithms are: the extended modified Yule Walker (YW); extended modified Yule Walker with Spectral analysis (YWS); and numerical state-space subspace system identification(N4SID) algorithm. The YW and N4SID have been introduced in previous publications while the YWS is introduced here. Issues addressed include: stability assessment requirements; automated subset selecting identified modes; using algorithms in an automated format; data assumptions and quality; and expected algorithm estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗