Search NASA⌕ Search

SEARCH · Search NASA

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Precision measurement of the branching fraction of J / ψ → K + K − via ψ ( 2 S ) → π + π − J / ψ

Using a sample of 448.1 × 10 6 ψ ( 2 S ) events collected with the BESIII detector, we perform a study of the decay J / ψ → K + K − via ψ ( 2 S ) → π + π − J / ψ . The branching fraction of J / ψ → K + K − is determined to be B K + K − = ( 3.072 ± 0.023 ( stat ) ± 0.050 ( syst ) ) × 10 − 4 , which is consistent with previous measurements but with significantly improved precision. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Precision measurement of the Ξ b − baryon lifetime

A sample of p p collision data, corresponding to an integrated luminosity of 5.5 fb − 1 and collected by the LHCb experiment during LHC Run 2, is used to measure the ratio of the lifetime of the Ξ b − baryon to that of the Λ b 0 baryon, r τ ≡ τ Ξ b − / τ Λ b 0 . The value r τ = 1.076 ± 0.013 ± 0.006 is obtained, where the first uncertainty is statistical and the second systematic. This value is averaged with the corresponding value from Run 1 to obtain r τ Run 1 , 2 = 1.078 ± 0.012 ± 0.007 . Multiplying by the world-average value of the Λ b 0 lifetime yields τ Ξ b − Run 1 , 2 = 1.578 ± 0.018 ± 0.010 ± 0.011 ps , where the uncertainties are statistical, systematic, and due to the limited knowledge of the Λ b 0 lifetime. This measurement improves the precision of the current world average of the Ξ b − lifetime by about a factor of 2, and is in good agreement with the most recent theoretical predictions. © 2024 CERN, for the LHCb Collaboration 2024 CERN

Aaij, R. (ORCID:0000000305331952)↗

Precision measurements of EFT parameters and BAO peak shifts for the Lyman- α forest

We present precision measurements of the bias parameters of the one-loop power spectrum model of the Lyman- α (Ly- α ) forest, derived within the effective field theory (EFT) of large-scale structure. We fit our model to the three-dimensional flux power spectrum measured from the ACCEL 2 hydrodynamic simulations. The EFT model fits the data with an accuracy of below 2% up to k = 2 h Mpc − 1 . Further, we analytically derive how nonlinearities in the three-dimensional clustering of the Ly- α forest introduce biases in measurements of the baryon acoustic oscillations (BAOs) scaling parameters in radial and transverse directions. From our EFT parameter measurements, we obtain a theoretical error budget of Δ α ∥ = − 0.2 % ( Δ α ⊥ = − 0.3 % ) for the radial (transverse) parameters at redshift z = 2.0 . This corresponds to a shift of − 0.3 % (0.1%) for the isotropic (anisotropic) distance measurements. We provide an estimate for the shift of the BAO peak for Ly- α -quasar cross-correlation measurements assuming analytical and simulation-based scaling relations for the nonlinear quasar bias parameters resulting in a shift of − 0.2 % ( − 0.1 % ) for the radial (transverse) dilation parameters, respectively. This analysis emphasizes the robustness of Ly- α forest BAO measurements to the theory modeling. We provide informative priors and an error budget for measuring the BAO feature—a key science driver of the currently observing Dark Energy Spectroscopic Instrument (DESI). Our work paves the way for full-shape cosmological analyses of Ly- α forest data from DESI and upcoming surveys such as the Prime Focus Spectrograph, WEAVE-QSO, and 4MOST. Published by the American Physical Society 2025

de Belsunce, Roger (ORCID:0000000336604028)↗

Precise Measurement of Born Cross Sections for e + e − → D D ¯ at s = 3.80 − 4.95 GeV

Using data samples collected with the BESIII detector at the BEPCII collider at center-of-mass energies ranging from 3.80 to 4.95 GeV, corresponding to an integrated luminosity of 20 fb − 1 , a measurement of Born cross sections for the e + e − → D 0 D ¯ 0 and D + D − processes is presented with unprecedented precision. Many clear peaks in the line shape of e + e − → D 0 D ¯ 0 and D + D − around the mass range of G ( 3900 ) , ψ ( 4040 ) , ψ ( 4160 ) , Y ( 4260 ) , and ψ ( 4415 ) , etc., are foreseen. These results offer crucial experimental insights into the nature of hadron production in the open-charm region. Published by the American Physical Society 2024

Physics↗

Precise Measurement of the e + e − → D s + D s − Cross Section at Center-of-Mass Energies from Threshold to 4.95 GeV

Using the e + e − collision data collected with the BESIII detector operating at the BEPCII collider, at center-of-mass energies from the threshold to 4.95 GeV, we present precise measurements of the cross section for the process e + e − → D s + D s − using a single-tag method. The resulting cross section line shape exhibits several new structures, thereby offering an input for a future coupled-channel analysis and model tests, which are critical to understand vector charmonium-like states with masses between 4 and 5 GeV. Published by the American Physical Society 2024

Ablikim, M.↗

Precision beam diagnostics at the NuMI facility using muon monitor observations

The Neutrinos at the Main Injector (NuMI) facility at Fermilab delivers an intense neutrino beam for multiple experiments by producing pions that decay into neutrinos, muons, and other particles. Magnetic horns—the primary pion focusing elements in the NuMI beamline—exhibit predominantly linear optics, enabling a predictable relationship between the proton beam and the resulting pion and muon phase spaces. This study has two primary objectives: first, to evaluate and confirm the linearity of the horn focusing mechanism using analytical models and numerical simulations; and second, to demonstrate that key beam parameters—such as proton beam intensity, beam position on target, and horn current—can be extracted from muon monitor observations within this linear optics framework. Using a machine learning model trained on spill-by-spill muon monitor data, we infer the horn current with a precision of ±0.05%, the beam intensity with ±0.1%, and the beam position on target with ±0.018⁢ mm horizontally and ±0.013⁢ mm vertically. This approach provides a reliable cross-check of beam parameters, helping to reduce systematic uncertainties that are critical for future experiments such as the Deep Underground Neutrino Experiment, which will rely on the neutrino beam produced by the Long-Baseline Neutrino Facility.

Beam control↗

Precise 𝐾* ⁡(892) → 𝐾⁡𝜋 branching fractions

Although discovered more than sixty years ago, direct measurement of the 𝐾*⁡(892) → 𝐾⁡𝜋 branching fractions is a formidable challenge that has not been attempted. Typically they are assumed to obey the isospin limit in hundreds of particle data measurements. We show that an abundance of recent amplitude analyses and other data, however, enables recovery of the ratios ℬ⁡(𝐾 *+ → 𝐾 + ⁢𝜋 0 )/ℬ⁡(𝐾 *+ → 𝐾$^0_S$ ⁢𝜋 + ) and 4⁢ℬ⁡(𝐾 *0 → 𝐾$^0_S$ ⁢𝜋 0 )/ℬ⁡(𝐾 *0 → 𝐾 +⁢ 𝜋 − ) at ∼5% precision.

Gligorov, Vladimir V. [Sorbonne Université, Paris ↗

High-precision Penning trap mass measurements of neutron-rich chlorine isotopes at the 𝑁 = 28 shell closure

Although it is known that the N = 28 spherical shell closure erodes, the strength of the closure with decreasing proton number Z < 20 is an open question in nuclear structure. Here, in this region of interest, high-precision mass measurements of neutron-rich 43-45 Cl isotopes were performed at the Low Energy Beam and Ion Trap (LEBIT) when coupled to the National Superconducting Cyclotron Lab. The resulting mass excesses (MEs) are ME(⁴³Cl) = -24114.4(1.7) keV, ME(⁴⁴Cl) = -20450.8(10.6) keV, and ME(⁴⁵Cl) = -18240.1(3.7) keV, and improve the uncertainty of these masses by up to a factor of ∼40 compared to the previous values reported in the 2020 Atomic Mass Evaluation. Comparison to ab initio calculations using the Valence-Space In-Medium Similarity Renormalization Group (VS-IMSRG) shows good agreement up to and including the closure.

Erington, H. [Michigan State Univ., East Lansing, ↗

Precision measurement of the $Ξ^0_b$ baryon lifetime

A sample of 𝑝⁢𝑝 collision data, corresponding to an integrated luminosity of 5.4 fb −1 and collected by the LHCb experiment during LHC Run 2, is used to measure the ratio of the lifetime of the $Ξ^0_b$ baryon to that of the $Λ^0_b$ baryon, 𝑟 𝜏 $≡$ $𝜏_{Ξ^0_b}$$/𝜏_{Λ^0_b}$. The value 𝑟$^{\textrm{Run 2}}_𝜏$ =1.004 ± 0.009 ± 0.006 is obtained, where the first uncertainty is statistical and the second systematic. This value is averaged with the corresponding value from Run 1 to obtain 𝑟 𝜏 =1.004 ± 0.008 ± 0.005. Multiplying by the known value of the $Λ^0_b$ lifetime yields $𝜏_{Ξ^0_b}$ = 1.475 ± 0.012 ± 0.008 ± 0.009 ps, where the last uncertainty is due to the limited knowledge of the $Λ^0_b$ lifetime. This measurement improves the precision of the current world average of the $Ξ^0_b$ lifetime by about a factor of two, and is in good agreement with the most recent theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision study of the massive Schwinger model near quantum criticality

We perform a numerical analysis of the massive Schwinger model in the presence of a background electric field. Using the Density Matrix Renormalization Group approach, we efficiently compute the spectrum of the Schwinger model on a staggered lattice with up to 3000 qubits. As a result, we achieve a precise computation of the critical mass of the massive Schwinger model to five digits using four different “criticality criteria,” observing perfect agreement among them Additionally, we discuss the effect of a four-fermion operator deformation of the Schwinger model and compute the critical mass for various values of the deformation parameter.

Critical phenomena↗

Precision Measurement of Neutrino Oscillation Parameters with 10 Years of Data from the NOvA Experiment

This Letter reports measurements of muon-neutrino disappearance and electron-neutrino appearance and the corresponding antineutrino processes between the two NOvA detectors in the NuMI neutrino beam. These measurements use a dataset with double the neutrino mode beam exposure that was previously analyzed, along with improved simulation and analysis techniques. A joint fit to these samples in the three-flavor paradigm results in the most precise single-experiment constraint on the atmospheric neutrino mass-splitting, $Δm^2_{32}= 2.431^{+0.036}_{-0.034} (-2.479^{+0.036}_{-0.036}) \times 10^{-3}$~eV$^2$ if the mass ordering is Normal (Inverted). In both orderings, a region close to maximal mixing with $\sin^2θ_{23}=0.55_{+0.06}^{-0.02}$ is preferred. The NOvA data show a mild preference for the Normal mass ordering with a Bayes factor of 2.4 (corresponding to 70% of the posterior probability), indicating that the Normal ordering is 2.4 times more probable than the Inverted ordering. When incorporating a 2D $Δm^2_{32}\textrm{--}\sin^2 2θ_{13}$ constraint based on Daya Bay data, this preference strengthens to a Bayes factor of 6.6 (87\%).

FOS: Physical sciences↗

Fabrication and characterization of a full-size ultra-precise lamellar grating for the Cosmic beamline at ALS-U

We have developed a new process for the production of ultra-precise variable line spacing (VLS) lamellar diffraction gratings through nanofabrication. The process enables the fabrication of full-size X-ray gratings with sub-nanometre accuracy in groove depth, an optimal land-to-groove ratio, and uniform groove depth across the entire grating area. We also established a method for evaluating VLS groove density variation using stitched Fizeau interferometry. The measurements confirmed the exceptionally high accuracy of the VLS groove density in the fabricated gratings, which is well within the specification tolerances while the residual groove density errors are vanishingly small. The gold-coated grating demonstrated near-theoretical diffraction efficiency across the energy range of 100–1200 eV.

36 MATERIALS SCIENCE↗

Clarifying Terminology in Microbial Ecology: A Call for Precision in Scientific Communication

The rapid evolution of microbiology as a field of research has led to the introduction of new terminology and the adaptation of existing terms. However, inconsistencies in the use of these terms, including variations across different scientific disciplines, can lead to confusion and miscommunication within the scientific community. This article discusses the importance of precise terminology in microbiome research, highlighting examples where terms have been misused or redefined without clear justification. We also present a list of frequently used terms in microbial ecology along with their specific definitions. We argue that the misuse of terminology can hinder scientific progress by creating ambiguity and misunderstanding. To address this, we propose a set of guidelines for the consistent use of key terms and provide clear definitions for some of the most commonly misused or newly introduced terms in the field. The definitions provided herein will also function as a guide for young researchers new to the field of microbial ecology. Accurate and consistent use of terminology is crucial for effective communication and collaboration in microbiology research. By adhering to standardised definitions, researchers can ensure that their work is clearly communicated and contributes meaningfully to the progress of science.

definitions↗

High-precision chemical quantum sensing in flowing monodisperse microdroplets

A method is presented for high-precision chemical detection that integrates quantum sensing with droplet microfluidics. Using nanodiamonds (ND) with fluorescent nitrogen-vacancy (NV) centers as quantum sensors, rapidly flowing microdroplets containing analyte molecules are analyzed. A noise-suppressed mode of optically detected magnetic resonance is enabled by pairing controllable flow with microwave control of NV electronic spins, to detect analyte-induced signals of a few hundredths of a percent of the ND fluorescence. Using this method, paramagnetic ions in droplets are detected with low limit-of-detection using small analyte volumes, with exceptional measurement stability over >10 3 s. In addition, these droplets are used as microconfinement chambers by co-encapsulating ND quantum sensors with various analytes such as single cells, suggesting wide-ranging applications including single-cell metabolomics and real-time intracellular measurements from bioreactors. Important advances are enabled by this work, including portable chemical testing devices, amplification-free chemical assays, and chemical imaging tools for probing reactions within microenvironments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precise test of lepton flavour universality in W -boson decays into muons and electrons in pp collisions at $\sqrt{s}$ =13 TeV with the ATLAS detector

The ratio of branching ratios of the $W$ boson to muons and electrons, $R^{μ/e}_{W}$ = $\mathcal{B}$($W$ → $μν$)/$\mathcal{B}$($W$ → $eν$), has been measured using 140 fb -1 of pp collision data at $\sqrt{s}$ = 13 TeV collected with the ATLAS detector at the LHC, probing the universality of lepton couplings. The ratio is obtained from measurements of the $t\overline{t}$ production cross section in the $ee$, $eμ$ and $μμ$ dilepton final states. To reduce systematic uncertainties, it is normalised by the square root of the corresponding ratio $R^{μμ/ee}_{Z}$ for the Z boson measured in inclusive $Z$ → $ee$ and $Z$ → $μμ$ events. By using the precise value of $R^{μμ/ee}_{Z}$ determined from $e^+$ $e^-$ colliders, the ratio $R^{μ/e}_{W}$ is determined to be $R^{μ/e}_{W}$ = 0.9995 ± 0.0022 (stat) ± 0.0036 (syst) ± 0.0014 (ext). The three uncertainties correspond to data statistics, experimental systematics and the external measurement of $R^{μμ/ee}_{Z}$, giving a total uncertainty of 0.0045, and confirming the Standard Model assumption of lepton flavour universality in $W$ boson decays at the 0.5% level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision measurement of the B0 meson lifetime using B0→J/ψK∗0 decays with the ATLAS detector

A measurement of the B0$$B^{0}$$ meson lifetime using B0→J/ψK∗0$$ B^{0} \rightarrow J/\psi K^{*0} $$ decays in data from 13 TeV$$\text {TeV}$$ proton–proton collisions with an integrated luminosity of 140fb-1$$ 140~\mathrm {fb^{-1}} $$ recorded by the ATLAS detector at the LHC is presented. The measured effective lifetime is τ=1.5053±0.0012(stat.)±0.0035(syst.)ps.$$ \tau = 1.5053\pm 0.0012~\mathrm {(stat.)} \pm 0.0035~\mathrm {(syst.)~ps}. $$The average decay width extracted from the effective lifetime, using parameters from external sources, is Γd=0.6639±0.0005(stat.)±0.0016(syst.)±0.0038(ext.)ps-1,$$\begin{aligned} \Gamma _d = 0.6639\pm 0.0005~\mathrm {(stat.)} \pm 0.0016~\mathrm {(syst.)}\\ \pm 0.0038~\text {(ext.)} \text {~ps}^{-1}, \end{aligned}$$where the uncertainties are statistical, systematic and from external sources. The earlier ATLAS measurement of Γs$$\Gamma _s$$ in the Bs0→J/ψϕ$$B^{0}_{s} \rightarrow J/\psi \phi $$ decay was used to derive a value for the ratio of the average decay widths Γd$$\Gamma _d$$ and Γs$$\Gamma _s$$ for B0$$B^{0} $$ and Bs0$$B^{0}_{s} $$ mesons respectively, of ΓdΓs=0.9905±0.0022(stat.)±0.0036(syst.)±0.0057(ext.).$$ \frac{\Gamma _d }{\Gamma _s } = 0.9905\pm 0.0022~\text {(stat.)} \pm 0.0036~\text {(syst.)} \pm 0.0057~\text {(ext.)}. $$The measured lifetime, average decay width and decay width ratio are in agreement with theoretical predictions and with measurements by other experiments. This measurement provides the most precise result of the effective lifetime of the B0$$B^{0}$$ meson to date.

Aad, G↗

A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton–proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector

The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton–proton collisions at $\sqrt{s} = 13$ TeV collected with the ATLAS detector during Run 2 at the Large Hadron Collider. The jet calibration uncertainty for anti-$k_T$ jets with a jet radius parameter of R$_\textrm{jet} = 0.4$ and in the central jet rapidity region is about 2.5% for transverse momenta ($p_{\text {T}}$) of 20 $\text {GeV}$ , about 0.5% for $p_{\text {T}} = 300$ GeV and 0.7% for $p_{\text {T}} = 4$ TeV . Excellent agreement is found with earlier determinations obtained from -balance based in situ methods ($Z/\gamma$ +jets). The combination of these two independent methods results in the most precise jet energy measurement achieved so far with the ATLAS detector with a relative uncertainty of 0.3% at $p_\textrm{T} = 300$ GeV and 0.6% at 4 TeV. The jet energy calibration is also derived with the single-particle calorimeter response measurements separately for quark- and gluon-induced jets and furthermore for jets with R jet varying from 0.2 to 1.0 retaining the correlations between these measurements. Differences between inclusive jets and jets from boosted top-quark decays, with and without grooming the soft jet constituents, are also studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Numerical eigen-spectrum slicing, accurate orthogonal eigen-basis, and mixed-precision eigenvalue refinement using OpenMP data-dependent tasks and accelerator offload

Performing a variety of numerical computations efficiently and, at the same time, in a portable fashion requires both an overarching design followed by a number of implementation strategies. All of these are exemplified below as we present transitioning the PLASMA numerical library from relying on dependence-driven large tasks to achieving utilization of fine grain tasking and offload to hardware accelerators while keeping its core dependence sets: OpenMP source code pragmas and runtime for most system-level functionality and basic low-level numerical kernels provided directly by hardware vendors or open source projects with vendor contributions. We also present new algorithmic methods and their efficient parallel implementations including fine grained tasking for eigen-spectrum slicing and offload for mixed-precision eigenvalue refinement. We provide performance, scaling, and numerical results showing sizable gains over the available solutions from either the open source and vendor-provided packages.

Luszczek, Piotr↗