Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dark-field x-ray microscopy for 2D and 3D imaging of microstructural dynamics at the European x-ray free-electron laser

Dark field x-ray microscopy (DXFM) can visualize microstructural distortions in bulk crystals. Using the femtosecond x-ray pulses generated by x-ray free-electron lasers (XFELs), DFXM can achieve sub-μm spatial resolution and <100 fs time resolution simultaneously. In this paper, we demonstrate ultrafast DFXM measurements at the European XFEL to visualize an optically driven longitudinal strain wave propagating through a diamond single crystal. We also present two DFXM scanning modalities that are new to the XFEL sources: spatial 3D and 2D axial-strain scans with sub-μm spatial resolution. With this progress in XFEL-based DFXM, we discuss new opportunities to study multi-timescale spatiotemporal dynamics of microstructures.

47 OTHER INSTRUMENTATION↗

Measurements of fast neutrons by bubble detectors

Neutron bubble detectors have been studied using Am-Be and D-D neuron sources, which give limited energy information. The Bubble Detector Spectrometer (BDS) have six different energy thresholds ranging from 10 KeV to 10 Mev. The number of bubbles obtained in each measurement is related to the dose (standardized response R) equivalent neutrons through sensitivity (b / {mu}Sv) and also with the neutron flux (neutrons per unit area) through a relationship that provided by the manufacturer. Bubble detectors were used with six different answers (0.11 b/ {mu}Sv, 0093 b/{mu}Sv, 0.14 b/{mu}Sv, 0.17 b/{mu}Sv, 0051 b/{mu}Sv). To test the response of the detectors (BDS) radiate a set of six of them with different energy threshold, with a source of Am-Be, placing them at a distance of one meter from it for a few minutes. Also, exposed to dense plasma focus Fuego Nuevo II (FN-II FPD) of ICN-UNAM, apparatus which produces fusion plasma, generating neutrons by nuclear reactions of neutrons whose energy emitting is 2.45 MeV. In this case the detectors were placed at a distance of 50 cm from the pinch at 90 Degree-Sign this was done for a certain number of shots. In both cases, the standard response is reported (Dose in {mu}Sv) for each of the six detectors representing an energy range, this response is given by the expression R{sub i}= B{sub i} / S{sub i} where B{sub i} is the number of bubbles formed in each and the detector sensitivity (S{sub i}) is given for each detector in (b / {mu}Sv). Also, reported for both cases, the detected neutron flux (n cm{sup -2}), by a given ratio and the response involves both standardized R, as the average cross section sigma. The results obtained have been compared with the spectrum of Am-Be source. From these measurements it can be concluded that with a combination of bubble detectors, with different responses is possible to measure the equivalent dose in a range of 10 to 100 {mu}Sv fields mixed neutron and gamma, and pulsed generated fusion devices.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The dynamics of thermal expansion in single crystal beryllium from nanosecond x-ray pulses

Single crystals of beryllium were exposed to nanosecond x-ray pulses generated from laser irradiated (1.5 x 10{sup 14} W/cm{sup 2}) gold targets. The characteristic gold M-band centered at 2.5 keV was measured by time integrated transmission grating spectroscopy and time resolved (spectrally integrated) x-ray photodiodes through beryllium targets of various thickness. Approximately decaying exponential temperature profiles were immediately induced in 100 {mu}m thick single crystal targets producing nearly instand surface motion as measured by free surface velocity interferometry. This temperature profile gave rise to a similar velocity history between a c-axis single crystal and a (10{bar 1}0) single crystal where a large initial acceleration gave way to a profile due to the internal temperature gradient. A smooth rise to the peak velocity was then followed by a sharp release originating from the opposite free surface. Differences between the velocities in each of these regions were found between the two single crystals investigated, which were due to the thermal expansion properties as a function of direction (including plasticity). These results can be used to predict behavior of polycrystalline targets relevant to instability seeding in inertial confinement fusion (ICF) ablators.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Similar Character of Generation of Superradiance Pulses in an Electron–Wave Backward Wave Oscillator

The phenomenon of superradiance of electron bunches provides a promising method for generating high-power ultrashort electromagnetic pulses. In the present paper, it is shown that the equations describing the interaction between an electron beam and an electromagnetic wave in a BWO-type oscillator admit a self-similar solution that describes an amplifying and compressing pulse. It is demonstrated by numerical simulation that the generation of short superradiance pulses is of self-similar character at the initial stage of the transient process. The specific features of the main characteristics of such pulses (the amplitude and width of a pulse and the coordinates of its maximum) are investigated as a function of time and control parameters. It is shown that, after a transient process, the solution reaches the self-similar stage, where the pulse amplitude and the inverse of its squared width grow linearly with time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emergence of pseudoresonance in high-intensity resonant inelastic x-ray scattering

We report resonant inelastic x-ray scattering (RIXS) spectra of neon atoms interacting with intense x-ray pulses generated using an x-ray free-electron laser (XFEL). We find that an unexpected peak emerges near the 𝐾⁢𝛼 line of Ne, which does not coincide with any physical resonances of neon ions. We perform theoretical calculations based on a quantum-state-resolved rate-equation approach with x-ray-induced processes including possible resonant excitations. Our dynamics simulations demonstrate that a sequence of multiple resonant photoabsorption events are involved and the interplay of those multiple resonances in combination with the relatively large spectral bandwidth of XFEL radiation leads to the emergent resonance-like structure at a position where no resonances exist. Our finding offers critical guidance for future applications of high-intensity RIXS at XFEL facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Fissile and fertile nuclear material measurements using a new differential die-away self-interrogation technique

This paper presents a new technique for the measurement of fissile and fertile nuclear materials in spent fuel and plutonium laden materials such as mixed oxide (MOX) fuel. The technique, called differential die-away self-interrogation, is similar to traditional differential die-away analysis, but it does not require a pulsed neutron generator or pulsed beam accelerator, and it can measure the fertile mass in addition to the fissile mass. The new method uses the spontaneous fission neutrons from {sup 244}Cm in spent fuel and {sup 240}Pu effective neutrons in MOX as the 'pulsed' neutron source with an average of {approx} 2.7 neutrons per pulse. The time correlated neutrons from the spontaneous fission and the subsequent induced fissions are analyzed as a function of time to determine the spontaneous fission rate, the induced fast-neutron fissions, and the induced thermal-neutron fissions. The fissile mass is determined from the induced thermal-neutron fissions that are produced by reflected thermal neutrons that originated from the spontaneous fission reaction. The sensitivity of the fissile mass measurement is enhanced by the use of two measurements, with and without a cadmium liner between the sample and the hydrogenous moderator. The fertile mass is determined from the multiplicity analysis of the neutrons detected soon after the initial triggering neutron is detected. The method obtains good sensitivity by the optimal design of two different neutron die-away regions: a short die-away for the neutron detector region and a longer die-away for the sample interrogation region.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization and performance of the DTAS detector

DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. In conclusion, special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of β-delayed neutron emitting nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast Graphene Light Emitters

Ultrafast electrically driven nanoscale light sources are critical components in nanophotonics. Compound semiconductor-based light sources for the nanophotonic platforms have been extensively investigated over the past decades. However, monolithic ultrafast light sources with a small footprint remain a challenge. Here in this paper, we demonstrate electrically driven ultrafast graphene light emitters that achieve light pulse generation with up to 10 GHz bandwidth across a broad spectral range from the visible to the near-infrared. The fast response results from ultrafast charge-carrier dynamics in graphene and weak electron-acoustic phonon-mediated coupling between the electronic and lattice degrees of freedom. We also find that encapsulating graphene with hexagonal boron nitride (hBN) layers strongly modifies the emission spectrum by changing the local optical density of states, thus providing up to 460% enhancement compared to the gray-body thermal radiation for a broad peak centered at 720 nm. Furthermore, the hBN encapsulation layers permit stable and bright visible thermal radiation with electronic temperatures up to 2000 K under ambient conditions as well as efficient ultrafast electronic cooling via near-field coupling to hybrid polaritonic modes under electrical excitation. These high-speed graphene light emitters provide a promising path for on-chip light sources for optical communications and other optoelectronic applications.

36 MATERIALS SCIENCE↗

α-Particle Detection and Charge Transport Characteristics in the A 3 M 2 I 9 Defect Perovskites (A = Cs, Rb; M = Bi, Sb)

Here, we have investigated the defect perovskites A 3 M 2 I 9 (A = Cs, Rb; M = Bi, Sb) as materials for radiation detection. The phase purity of Bridgman-grown A 3 M 2 I 9 single crystals was confirmed via high-resolution synchrotron X-ray diffraction, while density functional theory calculations (DFT) show surprisingly dispersive bands in the out-of-plane direction for these layered materials, with low effective masses for both holes and electrons. Accordingly, each of the four A 3 M 2 I 9 defect perovskites showed response to 241 Am α-particle irradiation for hole and electron electrode configurations, a remarkable ambipolar response that resembles the 3D halide perovskites. The electron response spectra were used to estimate the mobility–lifetime product (μτ) e for electrons in these materials, with Rb 3 Bi 2 I 9 showing the lowest (μτ) e value of 1.7 × 10 – 6 cm 2 V –1 and Cs 3 Bi 2 I 9 the highest (μτ) e of 5.4 × 10 –5 cm 2 V –1 . The rise time of the α-particle-generated pulse was used to estimate the electron mobility μ e of the A 3 M 2 I 9 defect perovskites, which ranged from 0.32 cm 2 V –1 s–1 for Rb 3 Sb 2 I 9 to 4.3 cm 2 V –1 s –1 in Cs 3 Bi 2 I 9 . Similar analysis of the hole response spectra yielded (μτ) h values for each A 3 M 2 I 9 compound, with Cs 3 Bi 2 I 9 again showing the highest (μτ) h value of 1.8 × 10 –5 cm 2 V –1 , while Rb 3 Bi 2 I 9 showed the lowest (μτ) h with 2.0 × 10 –6 cm 2 V –1 . Rise time analysis gave hole mobilities ranging from 1.7 cm 2 V –1 s –1 for Cs 3 Bi 2 I 9 to 0.14 cm 2 V –1 s –1 for Cs 3 Sb 2 I 9 . Comparing the experimental electron and hole mobilities to the effective masses obtained from DFT calculations revealed sizable discrepancies, possibly indicating self-trapping of charge carriers due to electron–phonon interactions. The α-particle response of the A 3 M 2 I 9 defect perovskites demonstrates their potential as semiconductor radiation detectors, with Cs 3 Bi 2 I 9 and Cs 3 Sb 2 I 9 showing the most promise.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental observation of attosecond control over relativistic electron bunches with two-colour fields

Energy coupling during relativistically intense laser–matter interactions is encoded in the attosecond motion of strongly driven electrons at the pre-formed plasma–vacuum boundary. Studying and controlling this motion can reveal details about the microscopic processes that govern a vast array of light–matter interaction phenomena, including those at the forefront of extreme laser–plasma science such as laser-driven ion acceleration, bright attosecond pulse generation and efficient energy coupling for the generation and study of warm dense matter. Here in this paper, we experimentally demonstrate that by precisely adjusting the relative phase of an additional laser beam operating at the second harmonic of the driving laser it is possible to control the trajectories of relativistic electron bunches formed during the interaction with a solid target at the attosecond scale. Finally, we observe significant enhancements in the resulting high-harmonic yield, suggesting potential applications for sources of ultra-bright, extreme ultraviolet attosecond radiation to be used in atomic and molecular pump–probe experiments

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparative Characteristics of Four Small Dense Plasma Focus Devices

Four small (in the energy range 2-7 kJ) dense plasma focus devices were elaborated and put into operation in the last several years: ING-103, DPF-10, PF-5M, and DPF-6. Each device has its own parameters (energy, current rise-time and magnitude, pulse duration of ionizing radiation of different types, weight, etc.) and together with the specific discharge chambers they are optimized for various applications. Comparative description of functioning parameters of these devices together with the results of the most successful applications is presented in the report.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On-site Real-Time Inspection System for Pump-impeller using X-band Linac X-ray Source

The methods of nondestructive testing (NDT) are generally ultrasonic, neutron, eddy-current and X-rays, NDT by using X-rays, in particular, is the most useful inspection technique having high resolution. We can especially evaluate corroded pipes of petrochemical complex, nuclear and thermal-power plants by the high energy X-ray NDT system. We develop a portable X-ray NDT system with X-band linac and magnetron. This system can generate a 950 keV electron beam. We are able to get X-ray images of samples with 1 mm spatial resolution. This system has application to real time impeller inspection because linac based X-ray sources are able to generate pulsed X-rays. So, we can inspect the rotating impeller if the X-ray pulse rate is synchronized with the impeller rotation rate. This system has application in condition based maintenance (CBM) of nuclear plants, for example. However, 950 keV X-ray source can only be used for thin tubes with 20 mm thickness. We have started design of a 3.95 MeV X-band linac for broader X-ray NDT application. We think that this X-ray NDT system will be useful for corrosion wastage and cracking in thicker tubes at nuclear plants and impeller of larger pumps. This system consists of X-band linac, thermionic cathode electron gun, magnetron and waveguide components. For achieving higher electric fields the 3.95 MeV X-band linac structure has the side-coupled acceleration structure. This structure has more efficient acceleration than the 950 keV linac with alternating periodic structure (APS). We adopt a 1.3 MW magnetron for the RF source. This accelerator system is about 30 cm long. The beam current is about 150 mA, and X-ray dose rate is 10 Gy at 1 m/500 pps. In this paper, the detail of the whole system concept and the electromagnetic field of designed linac structure will be reported.

43 PARTICLE ACCELERATORS↗

Propagation of rarefaction pulses in particulate materials with strain-softening behavior

We investigate rarefaction waves in nonlinear periodic systems with a 'softening' power-law relationship between force and displacement to understand the dynamic behavior of this class of materials. A closed form expression describing the shape of the strongly nonlinear rarefaction wave is exact for n = 1/2 and agrees well with the shape and width of the pulses resulting from discrete simulations. A chain of particles under impact was shown to propagate a rarefaction pulse as the leading pulse in initially compressive impulsive loading in the absence of dissipation. Compression pulses generated by impact quickly disintegrated into a leading rarefaction solitary wave followed by an oscillatory train. Such behavior is favorable for metamaterials design of shock absorption layers as well as tunable information transmission lines for scrambling of acoustic information.

42 ENGINEERING↗

Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transmission for the other wavelengths for downstream use. The second crystal is about 300 μm thick and makes the exit beam of the monochromator parallel to the incoming beam with an offset of 600 mm. Here we present details on the monochromator design and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voltage and pressure scaling of streamer dynamics in a helium plasma jet with N{sub 2} co-flow

Positive polarity applied voltage and gas pressure dependent scaling of cathode directed streamer propagation properties in helium gas flow guided capillary dielectric barrier discharge have been quantified from streamer velocity, streamer current, and streamer optical diameter measurements. All measurements of the non-stochastic streamer properties have been performed in a variable gas pressure glass cell with N{sub 2} co-flow and under self-consistent Poisson electric field dominated conditions to permit data comparison with 2-D streamer dynamics models in air/nitrogen. The streamer optical diameter was found to be nearly independent of both gas pressures, from 170 Torr up to 760 Torr, and also for applied voltages from 6 to 11 kV at 520 Torr. The streamer velocity was found to increase quadratically with increased applied voltage. These observed differences in the 2-D scaling properties of ionization wave sustained cathode directed streamer propagation in helium flow channel with N{sub 2} annular co-flow compared to the streamer propagation in air or nitrogen have been shown to be caused by the remnant ionization distribution due to large differences in the dissociative recombination rates of He{sub 2}{sup +} versus N{sub 4}{sup +} ions, for this 5 kHz repetition rate applied voltage pulse generated streamers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗