1,548 records · Page 33

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS

The Evolution of the Moon and the Terrestrial Planets

The thermal evolutions of the Moon, Mars, Venus, and Mercury are calculated theoretically starting from cosmochemical condensation models. An assortment of geological, geochemical, and geophysical data are used to constrain both the present-day temperatures and the thermal histories of the planets' interiors. Such data imply that the planets were heated during or shortly after formation and that all the terrestrial planets started their differentiations early in their history. Initial temperatures and core formation play the most important roles in the early differentiation. The size of the planet is the primary factor in determining its present-day thermal state. The Moon, smallest in size, is characterized as a differentiated body with a crust, a thick solid mantle, and an interior region which may be partially molten. It is presently cooling rapidly and is relatively inactive tectonically. Mercury, which probably has a large core, may have a 500-km-thick solid lithosphere and a partially molten core, if it is assumed that some heat sources exist in the core. If this is not the case, the planet's interior temperatures are everywhere below the melting curve for iron. The thermal evolution is dominated by the core separation and the high conductivity of iron that makes up the bulk of Mercury. Mars, intermediate in size, is assumed to have differentiated an Fe-FeS core. While the formation of an early crust is evident, large-scale melting and differentiation of the mantle silicates has occurred at least up until 1 b.y. ago. Present-day temperature profiles indicate moderate tectonic activity at the present time. Venus is characterized as a planet not unlike the Earth in many respects. Core formation has occurred probably during the first billion years after the formation. The present-day temperatures indicate a partially molten upper mantle overlain by a 100-km-thick lithosphere and a molten Fe-Ni core. We can expect that today Venus may have tectonic processes similar to the Earth's.

M Nafi Toksöz

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe

Nimbus and Landsat

The operation and systems design of a nickel cadmium battery system used on the Nimbus and LANDSAT satellites are discussed. Emphasis is placed on the charging-discharging operation of the battery system.

D A Baer

International Space Station Lithium-Ion Battery

The International Space Station (ISS) Electric Power System (EPS) currently uses Nickel-Hydrogen (Ni-H2) batteries to store electrical energy. The batteries are charged during insolation and discharged during eclipse. The Ni-H2 batteries are designed to operate at a 35 depth of discharge (DOD) maximum during normal operation in a Low Earth Orbit. Since the oldest of the 48 Ni-H2 battery Orbital Replacement Units (ORUs) has been cycling since September 2006, these batteries are now approaching their end of useful life. In 2010, the ISS Program began the development of Lithium-Ion (Li-ion) batteries to replace the Ni-H2 batteries and concurrently funded a Li-ion cell life testing project. This paper will include an overview of the ISS Li-Ion battery system architecture and the progress of the Li-ion battery design and development.

Battery

Hydrofluoroether (HFE) Cleaning Fluid Replacement and Qualification

This NASA Engineering and Safety Center (NESC) Technical Assessment Report addresses the urgent need to identify, test, and qualify replacement cleaning solvents and technologies following 3M’s decision to discontinue production of hydrofluoroether (HFE) products, including Novec HFE-7100, by the end of 2025. HFE-7100 is widely used across NASA for precision cleaning of ground and flight hardware, especially in oxygen system components, and as a heat transfer fluid in high-power-density thermal control systems. The assessment evaluates commercially available replacement solvents, alternative cleaning technologies, and their compatibility with NASA’s operational requirements. Key findings include the identification of viable solvent replacements, their performance in contaminant removal, materials compatibility, and oxygen system safety. The report also explores novel cleaning approaches, including aqueous, supercritical CO₂, cryogenic aerosol, plasma, UV-ozone, magnetically optimized fluids, and induced charge active filtration, highlighting their merits, limitations, and readiness for NASA adoption. The NESC provides recommendations for solvent selection, facility adaptation, and continued technology maturation to ensure mission continuity and regulatory compliance.

Alternative Cleaning Technologies

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Loop Heat Pipe

A Simplified Model of VIPER Thermal Management System. Part II: Integrated Vehicle

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) thermal management system (TMS) relies on four loop heat pipes (LHPs) to transport electronic waste heat to the vehicle cooling radiative surface and avoid overheating. The TMS has also ten constant conductance heat pipes (CCHPs) dedicated to balance the thermal load within the internal environment where the avionics boxes are mounted, also called warm electronic box (WEB), and to transport the heat from two of the science payload instruments. The TMS also uses two thermal straps to thermally link the batteries to the WEB. These thermal components, in addition to heaters, thermostat, multi-layer insulation (MLIs), and isolators forms the core of the VIPER TMS. The complex heat transport balance managed by the TMS is challenging to characterize and model. The more fidelity and granularity of a model, the more costly the computational resources needed and the longer the simulation and modeling time. When the priority is to provide quick but reliable assessments of the thermal performance or real time thermal feedback for training of console operators, simplified modeling tools are needed. To satisfy that need, this paper describes the effort to develop and correlate a model of VIPER TMS based on control volume approach. The correlation effort in particular focuses on hibernation, cold thermal balance, and hot thermal balance data from the integrated vehicle thermal vacuum (TVAC) test. Thus, the correlated model captures the heat leaks during hibernations and the performance at two extremes, bounding, operating scenarios.

Thermal Modeling

Development of the Orion Life-Support Integration Facility (OLIF)

Testing the life support hardware of a vehicle that is going to take humans beyond low-Earth orbit (LEO) in conditions similar to space is crucial. The Orion Life-Support Integration Facility (OLIF) at NASA Johnson Space Center (JSC) was designed and built to test the Orion vehicle’s hardware and software as integrated systems to provide a complete Environmental Control and Life Support System (ECLSS) system-level qualification. The existing 11 Foot human rated vacuum chamber has been adapted to accommodate and integrate various qualification and flight like components of the Orion vehicle’s Air Revitalization System (ARS), Pressure Control System (PCS), Active Thermal Control System (ATCS) and the Orion Crew Survival System Suits (OCSS). The ultimate goal was to create an analog testbed that could safely support up to four test subjects in open “shirt-sleeve” or closed suit loop configurations and simulate Orion Cabin conditions. This integrated hardware/software ARS and PCS will help identify any technical issues that should be addressed prior to the Artemis-2 mission. This paper will discuss the history of Orion ECLSS hardware development testing in the 11 Foot Chamber, the challenge of integrating flight hardware and software control systems, and the capabilities that make it a unique, world class facility for NASA. It will provide an overview of past and future testing, and the lessons learned along the way.

Peter A Masi

Isotopic Signature of Organic Molecules from Beyond the Solar System: An Enriched Methane D/H Ratio in the Interstellar Object 3I/ATLAS

Interstellar objects are interlopers from other planetary systems, and their volatile compositions provide a glimpse into planet formation around their host star. We present near-infrared spectra of the coma of interstellar object 3I/ATLAS measured with the James Webb Space Telescope. Our results demonstrate an unexpectedly high D/H = (3.31 ± 0.34)% for methane and represent an exceedingly rare detection of deuterated organic molecules in an interstellar object. This D/H ratio is a factor of 14 ± 2 higher than that measured in comet 67P/Churyumov-Gerasimenko by the Rosetta spacecraft, the only other comet for which CH3D has been detected, yet the ratio of deuteration in methane compared with water is consistent for both comets within 1.2σ. The D/H ratio in methane is observationally unconstrained in extrasolar sources to date, but the enriched ratio in 3I/ATLAS is most similar to those measured in other organic molecules toward primitive environments. The high D/H ratios of water and methane in 3I/ATLAS are a natural consequence of formation in a high D/H elemental ratio environment as a result of locally cold conditions in the protoplanetary disk and prior interstellar cloud. Thus, 3I/ATLAS formed in an environment very different from that in which our Sun and planets originated.

Interstellar Object 3I/ATLAS

In-suit CO2 Washout Test System (ICWTS) for CO2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

SCOAPE-II: A 2024 Multiplatform Measurement Campaign off the US Gulf Coast to Assess Oil and Gas Emissions on the Outer Continental Shelf

Nine years ago, the Department of Interior’s Bureau of Ocean Energy Management (BOEM), the Agency with Air Quality (AQ) jurisdiction over the Outer Continental Shelf (OCS) of the US Gulf Coast west of 87.5° W longitude, asked NASA to determine the feasibility of using satellite data to measure offshore emissions in a region of concentrated oil and natural gas (ONG) operations. To study this issue NASA and BOEM conducted the May 2019 Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf. SCOAPE addressed both technological and scientific issues related to measuring nitrogen dioxide (NO 2 , a common air pollutant), including contrasting near-shore and deepwater regimes. Given the April 2023 launch of the geostationary Tropospheric Emissions: Monitoring of Pollution (TEMPO) AQ satellite, a 2024 SCOAPE-II was conducted in the Gulf with both ship and aircraft measurements. We present an overview of the SCOAPE-II campaign, analysis and validation of satellite-observed NO 2 , and evaluate measurements of methane from ship, aircraft, and satellite near ONG platforms. Our SCOAPE-II results are as follows: 1) Satellite NO 2 measurements (∼13:30 local time) from the TROPOspheric Monitoring Instrument (TROPOMI) are more accurate than TEMPO’s hourly scans (8.6% vs. 23.6% mean absolute bias); a new version of TEMPO data is currently being processed; 2) ship and aircraft measurements captured dozens of NO 2 and methane plumes from ONG operations, showing that they are persistent emitters; 3) satellite measurements of methane failed to replicate ship and aircraft measurements, presenting ongoing challenges for operational emissions monitoring over the Gulf.

satellite validation

In-suit CO 2 Washout Test System (ICWTS) for CO 2 Washout Verification in Spacesuits

Since the time of Mercury, Gemini, and Apollo, NASA has been performing CO 2 washout verification of spacesuits with Human in the Loop (HITL) test methods. Classically, the only instrumentation both with the accuracy and response time necessary was that of external mass spectrometers or medical gas analyzers fed by a long capillary line from the oro-nasal region within the suit. The helmet CO 2 washout configuration including the challenges posed by variation of a suited human subject frequently created difficulty in capturing adequate breath by breath data. For example, a nasal cannula could be worn with reasonable comfort however it posed the following challenges: (1) impeded the test subject’s ability to do a proper Valsalva maneuver; (2) frequently provided a corrupted waveform with relative movement; (3) precluded the ability to evaluate the Flow Weighted Average (FWA) at subject interface. A mouthpiece could be used in lieu of a cannula but posed challenges as well: (1) created potential disturbances of the flow field; (2) precluded the test subject from speaking during usage; and (3) presented comfort issues limiting the duration of test points. These challenges made it impractical to use a mouthpiece for anything other than short lab ambient environment tests. Technology development and NASA investment have afforded new capabilities to address some of these measurements providing improved data collection and are implemented in the In-suit CO 2 Washout Test System (ICWTS) which provides suit inlet/outlet pressure, temperature, relative humidity, partial pressure of oxygen, partial pressure of CO 2 , and flow measurement coupled with the acquisition of the inspired PPCO 2 including the ability for FWA measurement. This test system, coupled with use of the In-suit Respiration Mannequin Assembly (IRMA) and Computational Fluid Dynamics (CFD) combine to provide a full picture of the in-suit oro-nasal flow field and effectiveness of CO 2 washout in a spacesuit design.

Colin Campbell

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Change Material Heat Capacitor

A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft’s propylene glycol-water mixture coolant system. Testing was performed with the phase change material contained under sealed conditions after a degassing procedure and exposed to atmosphere without prior degassing. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements and theoretical N-Pentadecane storage capacity.

Propylene Glycol Water

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide