Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability & Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Renewable Source Controls for Grid Stability

The goal of this study was to evaluate the small signal and transient stability of the Western Electricity Coordinating Council (WECC) under high penetrations of renewable energy, and to identify control technologies that would improve the system performance. The WECC is the regional entity responsible for coordinating and promoting bulk electric system reliability in the Western Interconnection. Transient stability is the ability of the power system to maintain synchronism after a large disturbance while small signal stability is the ability of the power system to maintain synchronism after a small disturbance. Transient stability analysis usually focuses on the relative rotor angle between synchronous machines compared to some stability margin. For this study we employed generator speed relative to system speed as a metric for assessing transient stability. In addition, we evaluated the system transient response using the system frequency nadir, which provides an assessment of the adequacy of the primary frequency control reserves. Small signal stability analysis typically identifies the eigenvalues or modes of the system in response to a disturbance. For this study we developed mode shape maps for the different scenarios. Prony analysis was applied to generator speed after a 1.4 GW, 0.5 second, brake insertion at various locations. Six different WECC base cases were analyzed, including the 2022 light spring case which meets the renewable portfolio standards. Because of the difficulty in identifying the cause and effect relationship in large power system models with different scenarios, several simulations were run on a 7-bus, 5-generator system to isolate the effects of different configurations. Based on the results of the study, for a large power system like the WECC, incorporating frequency droop into wind/solar systems provides a larger benefit to system transient response than replacing the lost inertia with synthetic inertia. From a small signal stability perspective, the increase in renewable penetration results in subtle changes to the system modes. In general, mode frequencies increase slightly, and mode shapes remain similar. The system frequency nadir for the 2022 light spring case was slightly lower than the other cases, largely because of the reduced system inertia. However, the nadir is still well above the minimum load shedding frequency of 59.5 Hz. Finally, several discrepancies were identified between actual and reported wind penetration, and additional work on wind/solar modeling is required to increase the fidelity of the WECC models.

power system stability↗

Performance Evaluation of High-Temperature Ultrasonic Communication System

Ultrasonic communication is a technique that allows transmitting information through a solid material such as tubes or bars using high-frequency elastic waves. The communication channels often extend into a high-temperature range in the field of power, oil, or nuclear industry. When the temperature is taken into consideration, the ultrasonic wave propagation through the solid channel is complex and unpredictable. It is necessary to study the influence of temperature on the ultrasonic guided wave to improve ultrasonic communication. In this study, a temperature control system is assembled to adjust the temperature of a steel pipe channel ranging from room temperature to 150 degrees C. The temperature performance evaluation is conducted to estimate the signal-to-noise ratio (SNR) and bit error rate (BER) of transferring the ultrasonic signal. The work aims to develop a reliable ultrasonic communication system in a high-temperature environment. The system temperature can be maintained at 150 degrees C and the LiNbO3 transducers are used as transmitters and receivers. No power amplifier is used in the communication system. The high-temperature ultrasonic communication system (HT-UCS) is feasible at 150 degrees C and can achieve a bit rate of 10 kbps without any error.

HT-UCS↗

Improved FGD dewatering process cuts solid wastes

In 2007, Duke Energy's W.H. Zimmer Station set out to advance the overall performance of its flue gas desulfurization (FGD) dewatering process. The plant implemented a variety of measures, including upgrading water-solids separation, improving polymer program effectiveness and reliability, optimizing treatment costs, reducing solid waste sent to the landfill, decreasing labor requirements, and maintaining septic-free conditions in clarifiers. The changes succeeded in greatly reducing solid waste generation and achieving total annual savings of over half a million dollars per year. 8 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Landowner’s Guide for Compatible Use of BPA Rights-of-Way

Keeping transmission lines safe and reliable is a critical priority for the Bonneville Power Administration. The key element in achieving those objectives is BPA’s ability to construct, operate and maintain its transmission lines and rights-of-way — the area under and around the lines. You can help BPA keep these rights-of-way clear of trees, brush and structures that could affect the safety or reliability of the transmission system. Prior to planting, digging, or constructing within BPA’s rights-of-way, fill out BPA’s Land Use Application Form. The information you provide on the application helps BPA understand your proposed use and the potential impacts to public safety, and the safety of our crews. BPA also reviews the application to determine whether a proposed use of land is compatible with the construction, operation and maintenance of BPA transmission lines. Coordinating with BPA early in your planning process can keep you safe and avoid wasting time and money.

Rights-of-way, transmission lines, BPA Land Use Ap↗

Multileaf Collimator Characteristics and Reliability Requirements for IMRT Elekta System

Understanding the characteristics of a multileaf collimator (MLC) system, modeling MLC in a treatment planning system, and maintaining the mechanical accuracy of the linear accelerator gantry head system are important factors in the safe implementation of an intensity-modulated radiotherapy program. We review the characteristics of an Elekta MLC system, discuss the necessary MLC modeling parameters for a treatment planning system, and provide a novel method to establish an MLC leaf position quality assurance program. To perform quality assurance on 40 pairs of individual MLC leaves is a time-consuming and difficult task. In this report, an effective routine MLC quality assurance method based on the field edge of a backup jaw as referenced in conjunction with a diode array as a radiation detector system is discussed. The sensitivity of this test for determining the relative leaf positions was observed to be better than 0.1 mm. The Elekta MLC leaf position accuracy measured with this system has been better than 0.3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

Passive Safety System Reliability Analysis: Methodology, Application, and Results

Many advanced reactor designs rely on passive systems to provide assurance that certain safety functions, such as reactivity control and reactor heat removal, are maintained during transient scenarios. The performance of these systems is sensitive to boundary and environmental conditions and can lead to functional failure, which is the inability of the system to perform as intended even without any physical failures. Additionally, conditions can cause the passive systems to operate in an intermediate or degraded state. These operational modes of passive systems and their overall reliability can be difficult to capture in traditional probabilistic frameworks where discrete operating modes are assumed or time-dependent boundary conditions are not accounted for. Novel strategies and methods are needed to be able to capture the reliability of these passive systems and their impact on facility safety. The current abstract provides a summary of such a methodology and examples of its use in a case study, the GE Hitachi (GEH) PRISM probabilistic safety assessment (PSA), and the U.S. Department of Energy (USDOE) Versatile Test Reactor (VTR) PSA.

Bucknor, M.↗

Using Qualified On-Site Nuclear Power Plant Simulators in Human Factors Validations of Control Room Upgrades

Existing commercial nuclear power plants (NPPs) are valuable assets in the infrastructure portfolio of the United States (U.S.) because they safely and reliably generate about 1/5th of all the electricity used. The instrumentation and control (I&C) systems in commercial NPPs are the ‘eyes and ears' of the operator, allowing operators to maintain situation awareness, thereby allowing the plant to operate safely and efficiently for all phases of operation. Because the I&C systems in NPPs are still mostly based on analog technologies, which are reliable but not especially cost-effective, upgrading the existing I&C in com-mercial NPPs to new digital I&C is very important. Furthermore, simulators and simulation are critical human factors engineering tools for this I&C modernization work. NPP control room simulators are essential test beds to simulate normal, abnormal, and emergency operations that allow human factors researchers to safely and realistically evaluate early design phase prototypes of the upgraded digital I&C, and validate final as-built digital I&C systems that have been modernized deployed in NPPs. This paper describes research performed using qualified on-site NPP simulators to perform human factors validations of digital I&C control room upgrades.

99 GENERAL AND MISCELLANEOUS↗

A new bipolar Qtrim power supply system

This year marks the 15th run of RHIC (Relativistic Heavy Ion Collider) operations. The reliability of superconducting magnet power supplies is one of the essential factors in the entire accelerator complex. Besides maintaining existing power supplies and their associated equipment, newly designed systems are also required based on the physicist’s latest requirements. A bipolar power supply was required for this year’s main quadruple trim power supply. This paper will explain the design, prototype, testing, installation and operation of this recently installed power supply system.

43 PARTICLE ACCELERATORS↗

Prediction of carbon nanostructure mechanical properties and the role of defects using machine learning

Graphene-based nanostructures hold immense potential as strong and lightweight materials, however, their mechanical properties such as modulus and strength are difficult to fully exploit due to challenges in atomic-scale engineering. This study presents a database of over 2,000 pristine and defective nanoscale CNT bundles and other graphitic assemblies, inspired by microscopy, with associated stress–strain curves from reactive molecular dynamics (MD) simulations using the reactive INTERFACE force field (IFF-R). These 3D structures, containing up to 80,000 atoms, enable detailed analyses of structure-stiffness-failure relationships. By leveraging the database and physics- and chemistry-informed machine learning (ML), accurate predictions of elastic moduli and tensile strength are demonstrated at speeds 1,000 to 10,000 times faster than efficient MD simulations. Hierarchical Graph Neural Networks with Spatial Information (HS-GNNs) are introduced, which integrate chemistry knowledge. HS-GNNs as well as extreme gradient boosted trees (XGBoost) achieve forecasts of mechanical properties of arbitrary carbon nanostructures with only 3 to 6% mean relative error. The reliability equals experimental accuracy and is up to 20 times higher than other ML methods. Predictions maintain 8 to 18% accuracy for large CNT bundles, CNT junctions, and carbon fiber cross-sections outside the training distribution. The physics- and chemistry-informed HS-GNN works remarkably well for data outside the training range while XGBoost works well with limited training data inside the training range. The carbon nanostructure database is designed for integration with multimodal experimental and simulation data, scalable beyond 100 nm size, and extendable to chemically similar compounds and broader property ranges. The ML approaches have potential for applications in structural materials, nanoelectronics, and carbon-based catalysts.

Winetrout, Jordan J.↗

Artificial intelligence-based predictive modeling for imaging neutral particle analyzers on the DIII-D tokamak

The Imaging Neutral Particle Analyzer (INPA) at DIII-D is a diagnostic system used to accurately resolve the energy and spatial distributions of fast ions in fusion plasmas. A novel artificial intelligence (AI) technique named INPA-net is based on Reservoir Computing Networks and developed here to predict active and passive signals produced by charge-exchange reactions from injected and edge-cold neutrals, respectively, in magnetically confined fusion plasmas. This model is trained using a set of 21 time domain signals between 0 s to 3.35 s that includes injected beam and thermal plasma information, and 6444 real 2D experimental images of the INPA in 12 plasma discharges at DIII-D. The trained neural network is able to forecast experimental images in real-time. The model achieves an R-squared value of 0.91, which is higher than the 0.83 value achieved by a simple linear regression model. This improvement highlights the model's enhanced predictive accuracy for measured images from the validation set. This AI approach is valuable due to its rapid response times and potential for integration into real-time plasma control systems. A version of this model capable of generating syntehic images would be useful for the real-time monitoring of fast-ion transport. A comprehensive sensitivity study reveals that INPA-net maintains high performance even with variations in the input parameters, indicating the model's robustness and reliability. While developed for the INPA, the underlying architecture is adaptable and may be applied to various 2D imaging diagnostics in fusion research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operational Experience with the Frontier System in CMS

The Frontier framework is used in the CMS experiment at the LHC to deliver conditions data to processing clients worldwide, including calibration, alignment, and configuration information. Each central server at CERN, called a Frontier Launchpad, uses tomcat as a servlet container to establish the communication between clients and the central Oracle database. HTTP-proxy Squid servers, located close to clients, cache the responses to queries in order to provide high performance data access and to reduce the load on the central Oracle database. Each Frontier Launchpad also has its own reverse-proxy Squid for caching. The three central servers have been delivering about 5 million responses every day since the LHC startup, containing about 40 GB data in total, to more than one hundred Squid servers located worldwide, with an average response time on the order of 10 milliseconds. The Squid caches deployed worldwide process many more requests per day, over 700 million, and deliver over 40 TB of data. Several monitoring tools of the tomcat log files, the accesses of the Squids on the central Launchpad servers, and the availability of remote Squids have been developed to guarantee the performance of the service and make the system easily maintainable. Following a brief introduction of the Frontier framework, we describe the performance of this highly reliable and stable system, detail monitoring concerns and their deployment, and discuss the overall operational experience from the first two years of LHC data-taking.

Blumenfeld, Barry↗

Characterization and novel application of power over fiber for electronics in a harsh environment

Power-over-Fiber (PoF) technology has been used extensively in settings where high voltages require isolation from ground. In a novel application of PoF, power is provided to photon detector modules located on a surface at ∼ 300 kV with respect to ground in the planned DUNE experiment. In cryogenic environments, PoF offers a reliable means of power transmission, leveraging optical fibers to transfer optical power. PoF technology excels in maintaining low noise levels when delivering power to sensitive electronic systems operating in extreme temperatures and high voltage environments. This paper presents the R&D effort of PoF in extreme conditions and underscores its capacity to revolutionize power delivery and management in critical applications, offering a dependable solution with low noise, optimal efficiency (∼ 51%), and superior isolation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY2014 LX-21 Blasting Cap Testing

For a new material to qualify as an Extremely Insensitive Substance (EIS), the material must pass the UN Test 7, EIS Cap Test. This test attempts to measure the shock sensitivity of the material to a standard detonator at its nominal shipping density. The standard detonator specified for this test is based upon the historical number eight, #8, blasting cap. The standard detonator must contain a base charge (output charge) greater than or equal to 450mg and have a detonation velocity of at least 7.0 km/s. The Du Pont E-1A blasting cap, which is no longer made by Du Pont, was originally used to qualify TATB-based insensitive materials in the DOE. This detonator met the requirements of the EIS Cap Test. Several other commercial vendors currently sell products that are listed as equivalent to a number eight blasting cap, but have, in several cases, exceeded the original output energy of the historical number eight. By the loose specification that the number eight contain at least 450mg of output explosive, any product containing at least this quantity can be labeled as a number eight. Indeed, for most applications, higher output energy merely means a better, more reliable product. For standards testing, variation the output energy greatly affects the test results. Pantex has maintained a quantity of the original, number eight blasting caps the DOE used to qualify TATB materials (The DOE uses an IHE qualification, which is similar to the HD 1.6 classification, and requires a similar EIS Cap Test.) In FY-13, we acquired blasting caps from the original Pantex supply and from two commercial vendors for characterization and comparison. Our goals were to first characterize each of the three standard detonators with the intention of using a detonator that was as equivalent to the Du Pont number eight blasting cap as possible. Second, to work with a commercial vendor to produce a number eight equivalent that would either be based on a safer initiation technology such as an exploding bridge wire (EBW) or exploding foil initiator (EFI) – most commercial units hot-wire based, which present considerable safety concerns.

42 ENGINEERING↗

Benchmark datasets for SARS-CoV-2 surveillance bioinformatics

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the cause of coronavirus disease 2019 (COVID-19), has spread globally and is being surveilled with an international genome sequencing effort. Surveillance consists of sample acquisition, library preparation, and whole genome sequencing. This has necessitated a classification scheme detailing Variants of Concern (VOC) and Variants of Interest (VOI), and the rapid expansion of bioinformatics tools for sequence analysis. These bioinformatic tools are means for major actionable results: maintaining quality assurance and checks, defining population structure, performing genomic epidemiology, and inferring lineage to allow reliable and actionable identification and classification. Additionally, the pandemic has required public health laboratories to reach high throughput proficiency in sequencing library preparation and downstream data analysis rapidly. However, both processes can be limited by a lack of a standardized sequence dataset. We identified six SARS-CoV-2 sequence datasets from recent publications, public databases and internal resources. In addition, we created a method to mine public databases to identify representative genomes for these datasets. Using this novel method, we identified several genomes as either VOI/VOC representatives or non-VOI/VOC representatives. To describe each dataset, we utilized a previously published datasets format, which describes accession information and whole dataset information. Additionally, a script from the same publication has been enhanced to download and verify all data from this study.

60 APPLIED LIFE SCIENCES↗

2015 Stewardship Science Academic Programs Annual

The Stockpile Stewardship Academic Programs (SSAP) are essential to maintaining a pipeline of professionals to support the technical capabilities that reside at the National Nuclear Security Administration (NNSA) national laboratories, sites, and plants. Since 1992, the United States has observed the moratorium on nuclear testing while significantly decreasing the nuclear arsenal. To accomplish this without nuclear testing, NNSA and its laboratories developed a science-based Stockpile Stewardship Program to maintain and enhance the experimental and computational tools required to ensure the continued safety, security, and reliability of the stockpile. NNSA launched its academic program portfolio more than a decade ago to engage students skilled in specific technical areas of relevance to stockpile stewardship. The success of this program is reflected by the large number of SSAP students choosing to begin their careers at NNSA national laboratories.

Stone, Terri↗

How to Support Reliability and Maintenance of Your Equipment [Poster]

Preventive maintenance is routine maintenance performed on equipment and systems to prevent them from failing and maintain expected performance. Pantex and Y-12 have different procedures in how they create and implement PM. With a standardized procedure across both plants, the following will be supported: (1) Worker safety, (2) Reduced material and downtime costs, (3) Completion of PM tasks. The purpose of the project is to gather information on the “pilot” facility to see how the proposed actions will affect the PM program and how it can be applied plant-wide.

99 GENERAL AND MISCELLANEOUS↗

10 CFR 830 Major Modification Determination for the ATR Diesel Bus (E-3) and Switchgear Replacement

Near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent subprojects. The first project, subject of this determination, will replace the existent diesel-electrical bus (E-3) and associated switchgear. More specifically, INL proposes transitioning ATR to 100% commercial power with appropriate emergency backup to include: • Provide commercial power as the normal source of power to the ATR loads currently supplied by diesel-electric power. • Provide backup power to the critical ATR loads in the event of a loss of commercial power. • Replace obsolescent critical ATR power distribution equipment, e.g., switchgear, transformers, motor control centers, distribution panels. Completion of this and two other age-related projects (primary coolant pump and motor replacement and emergency firewater injection system replacement) will resolve major age related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues make the project a major modification: 1. Evaluation Criteria #2 (Footprint change). The addition of a new PC-4 structure to the ATR Facility to house safety-related SSCs requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., structural qualification, fire suppression) to ensure no adverse impacts to the safety-related functions of the housed equipment. 2. Evaluation Criteria #3 (Change of existing process). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps requires careful attention and analysis to ensure it meets a project primary object to maintain or reduce CDF and does not negatively affect the efficacy of the currently approved strategy. 3. Evaluation Criteria #5 (Create the need for new or revised safety SSCs). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps, based on the pre-conceptual design, will require the addition of two quick start diesel generators, their associated power coordination/distribution controls, and a UPS to the list of safety-related SSCs. Similarly to item 1 above, the addition of these active SSCs to the list of safety-related SSCs and replacement of the E-3 bus requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., seismic qualification, isolation of redundant trains from common fault failures) to ensure no adverse impacts to the safety-related functions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗