Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Logarithmic accuracy of parton showers: a fixed-order study

We formulate some first fundamental elements of an approach for assessing the logarithmic accuracy of parton-shower algorithms based on two broad criteria: their ability to reproduce the singularity structure of multi-parton matrix elements, and their ability to reproduce logarithmic resummation results. We illustrate our approach by considering properties of two transverse-momentum ordered final-state showers, examining features up to second order in the strong coupling. In particular we identify regions where they fail to reproduce the known singular limits of matrix elements. Here, the characteristics of the shower that are responsible for this also affect the logarithmic resummation accuracies of the shower, both in terms of leading (double) logarithms at subleading N C and next-to-leading (single) logarithms at leading N C .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Treatment Planning and Volumetric Response Assessment for Yttrium-90 Radioembolization: Semiautomated Determination of Liver Volume and Volume of Tumor Necrosis in Patients with Hepatic Malignancy

Purpose: The primary purpose of this study was to demonstrate intraobserver/interobserver reproducibility for novel semiautomated measurements of hepatic volume used for Yttrium-90 dose calculations as well as whole-liver and necrotic-liver (hypodense/nonenhancing) tumor volume after radioembolization. The secondary aim was to provide initial comparisons of tumor volumetric measurements with linear measurements, as defined by Response Evaluation Criteria in Solid Tumors criteria, and survival outcomes. Methods: Between 2006 and 2009, 23 consecutive radioembolization procedures were performed for 14 cases of hepatocellular carcinoma and 9 cases of hepatic metastases. Baseline and follow-up computed tomography obtained 1 month after treatment were retrospectively analyzed. Three observers measured liver, whole-tumor, and tumor-necrosis volumes twice using semiautomated software. Results: Good intraobserver/interobserver reproducibility was demonstrated (intraclass correlation [ICC] > 0.9) for tumor and liver volumes. Semiautomated measurements of liver volumes were statistically similar to those obtained with manual tracing (ICC = 0.868), but they required significantly less time to perform (p < 0.0001, ICC = 0.088). There was a positive association between change in linear tumor measurements and whole-tumor volume (p < 0.0001). However, linear measurements did not correlate with volume of necrosis (p > 0.05). Dose, change in tumor diameters, tumor volume, and necrotic volume did not correlate with survival (p > 0.05 in all instances). However, Kaplan-Meier curves suggest that a >10% increase in necrotic volume correlated with survival (p = 0.0472). Conclusion: Semiautomated volumetric analysis of liver, whole-tumor, and tumor-necrosis volume can be performed with good intraobserver/interobserver reproducibility. In this small retrospective study, measurements of tumor necrosis were suggested to correlate with survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Large Scale Production of Magnetic Nanoparticles Using Bacterial Fermentation

Microbial production of nano-sized particles has a demonstrated capacity to make highly crystalline pure phase magnetite or with some substitution of Fe by Co, Ni, Cr, Mn, Zn or the rare earths. Microbial production of magnetic nanoparticles can be achieved in large quantities and at low cost. Over 1 kg (wet weight) of Zn-substituted magnetite (nominal composition of Zn0.6Fe2.4O4) has been recovered from 30 L fermentations. Transmission electron microscopy (TEM) was used to confirm that this mass produced extracellular magnetites exhibited good mono-dispersity. TEM results also showed a highly reproducible particle size and corroborated average crystallite size (ACS) of 13.1 0.8 nm determined through X-ray diffraction (N=7) at a 99 % confidence level. Based on scale-up experiments performed using a 35 L reactor, the increase in ACS reproducibility may be attributed to an increase of electron donor input, availability of divalent substitution metal ions and less ferrous ions in the case of substituted magnetite, increased reactor volume overcoming differences in each batch, or a combination of the above. While costs of commercial nanometer sized magnetite (25-50 nm) may cost $500/kg, microbial production is likely capable of producing 5-90 nm pure or substituted magnetites at a fraction of the cost of traditional chemical synthesis. While there are numerous approaches for the synthesis of nanoparticles, bacterial fermentation of magnetite or metal-substituted magnetite may represent an advantageous manufacturing technology with respect to yield, reproducibility and scalable synthesis with low costs at low energy input.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging

Objectives: The purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts. Methods: For each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility. Results: In all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%. Conclusions: An automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phonon contribution to the shear viscosity of a superfluid Fermi gas in the unitarity limit

We present a detailed analysis of the contribution of small-angle Nambu–Goldstone boson (phonon) collisions to the shear viscosity, η, in a superfluid atomic Fermi gas close to the unitarity limit. We show that the experimental values of the shear viscosity coefficient to entropy ratio, η/s, obtained at the lowest reached temperature can be reproduced assuming that phonons give the leading contribution to η. The phonon contribution is evaluated considering 1↔2 processes and taking into account the finite size of the experimental system. In particular, for very low temperatures, T≲0.1T{sub F}, we find that phonons are ballistic and the contribution of phonons to the shear viscosity is determined by the processes that take place at the interface between the superfluid and the normal phase. This result is independent of the detailed form of the phonon dispersion law and leads to two testable predictions: the shear viscosity should correlate with the size of the optical trap and it should decrease with decreasing temperature. For higher temperatures the detailed form of the phonon dispersion law becomes relevant and, within our model, we find that the experimental data for η/s can be reproduced assuming that phonons have an anomalous dispersion law. -- Highlights: •We study the contribution of phonons to shear viscosity of a cold Fermi gas at unitary. •The shear viscosity to entropy ratio (η/s) is reproduced for T<∼0.1T{sub F}. •For very low temperatures η/s correlates with the size of the optical trap. •We explain η/s for T>∼0.1T{sub F} assuming an anomalous dispersion law for phonons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimized anion exchange column isolation of zirconium-89 (89Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform

Zirconium-89 (89Zr), produced by the (p,n) reaction from naturally monoisotopic yttrium (natY), is a promising positron emitting isotope for immunoPET imaging. Its long half-life of 78.4 h is sufficient for evaluating slow physiological processes. A prototype automated fluidic system, coupled to on-line and in-line detectors, has been constructed to facilitate development of new 89Zr purification methodologies. The highly reproducible reagent delivery platform and near-real time monitoring of column effluents allows for efficient method optimization. The separation of Zr from dissolved Y metal targets was evaluated using several anion exchange resins. Each resin was evaluated against its ability to quantitatively capture Zr from a load solution that is high in dissolved Y. The most appropriate anion exchange resin for this application was identified, and the separation method was optimized. The method is capable of a high Y decontamination factor (>105) and has been shown to separate Fe, an abundant contaminant in Y foils, from the 89Zr elution fraction. Finally, the performance of the method was evaluated using cyclotron bombarded Y foil targets. The separation method was shown to achieve >95% recovery of the 89Zr present in the foils. The 89Zr eluent, however, was in a chemical matrix not immediately conducive to labeling onto proteins. The main intent of this study was to develop a tandem column 89Zr purification process, wherein the anion exchange column method described here is the first separation in a dual-column purification process.

Zirconium-89, ImmunoPET, medical isotope, automati↗

Computational analysis of flame initiation, quenching, and re-ignition in a prechamber natural gas engine under varying EGR-dilution levels

The on-road natural-gas (NG) fueled transportation relies on stoichiometric spark-ignition engines for the advantages of simple after-treatment system despite the efficiency penalty relative to lean-burn combustion strategies. Exhaust gas recirculation (EGR) has the potential to reduce this efficiency gap at low to moderate loads without the need for complex lean-exhaust aftertreatment systems. However, EGR dilution leads to reduced combustion stability and increased cycle-to-cycle variability. A promising technology that has the potential to achieve reliable operation under diluted conditions is the prechamber ignition (or turbulent jet ignition) which uses chemically active turbulent jets generated from combustion inside a prechamber to initiate, stabilize and accelerate combustion of the mixture inside the main chamber. The present work focusses on developing a RANS-based CFD approach to accurately reproduce in-cylinder phenomena in a stoichiometric NG prechamber-assisted heavy-duty engine without relying on complex combustion models that account for turbulence-chemistry interactions. This is necessary because reactive prechamber jets at high EGR dilution tend to extinguish while emerging into the main chamber, which is followed by a phase of re-ignition — a phenomenon that conventional G-equation or well-stirred reactor combustion models cannot reproduce. With addition of a damping multiplier to the well-stirred reactor model, the predictions are seen to show good agreement with experimental pressure evolution and combustion images acquired from a single cylinder Cummins N-14 optical diesel engine retrofitted with a prechamber ignition system. Model predictions of local heat release in the flame and temperature evolution inside the flame are used to investigate combustion dynamics in the prechamber and the main chamber. It is seen that the well-stirred reactor model with the inclusion of damping is able to reproduce the temporary reduction in heat release within the flame, which can be considered equivalent to quenching of jets, and the subsequent re-ignition of the flame inside the main chamber. The delay between quenching and re-ignition depends on the amount of dilution, as explained by an illustration of flame evolution in a Borghi diagram.

Prechamber ignition↗

Effectiveness of Using Fewer Implanted Fiducial Markers for Prostate Target Alignment

Purpose: To evaluate the impact of the number and location of intraprostatic fiducial markers on the accuracy and reproducibility of daily prostate target alignment and to evaluate the migration of such markers. Methods and Materials: Three gold fiducial markers were implanted transrectally under ultrasound guidance near the apex, middle, and base of the prostate in 10 prostate cancer patients. The patients had pretreatment in-room computed tomography (CT) scans three times a week, for approximately 25 CT scans per patient during the 8-week treatment course. A total of 1280 alignments were performed using different alignment scenarios: whole-prostate soft tissue alignment (the gold standard), bone alignment, and seven permutations of alignments using one, two, or three fiducial markers. The results of bone alignment and fiducial alignment were compared with the results of whole-prostate alignment. Fiducial migration was also evaluated. Results: Single-fiducial-marker alignment was more accurate and reproducible than bone alignment. However, due to organ deformation, single fiducial markers did not always reliably represent the position of the entire prostate. The use of two-fiducial combinations was more accurate and reproducible than single-fiducial alignment, and use of all three fiducials was the best. Use of an apex fiducial together with a base fiducial rivaled the use of all three fiducials markers together. Fiducial migration was minimal. Conclusions: The number and the location of implanted fiducial markers affect the accuracy and reliability of daily prostate target alignment. The use of two or more fiducial markers is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of CT and MR-CT Fusion for Prostate Post-Implant Dosimetry

Purpose: The use of T2 MR for postimplant dosimetry (PID) after prostate brachytherapy allows more anatomically accurate and precise contouring but does not readily permit seed identification. We developed a reproducible technique for performing MR-CT fusion and compared the resulting dosimetry to standard CT-based PID. Methods and Materials: CT and T1-weighted MR images for 45 patients were fused and aligned based on seed distribution. The T2-weighted MR image was then fused to the aligned T1. Reproducibility of the fusion technique was tested by inter- and intraobserver variability for 13 patients. Dosimetry was computed for the prostate as a whole and for the prostate divided into anterior and posterior sectors of the base, mid-prostate, and apex. Results: Inter- and intraobserver variability for the fusion technique showed less than 1% variation in D90. MR-CT fusion D90 and CT D90 were nearly equivalent for the whole prostate, but differed depending on the identification of superior extent of the base (p = 0.007) and on MR/CT prostate volume ratio (p = 0.03). Sector analysis showed a decrease in MR-CT fusion D90 in the anterior base (ratio 0.93 {+-}0.25, p < 0.05) and an increase in MR-CT fusion D90 in the apex (p < 0.05). The volume of extraprostatic tissue encompassed by the V100 is greater on MR than CT. Factors associated with this difference are the MR/CT volume ratio (p < 0.001) and the difference in identification of the inferior extent of the apex (p = 0.03). Conclusions: We developed a reproducible MR-CT fusion technique that allows MR-based dosimetry. Comparing the resulting postimplant dosimetry with standard CT dosimetry shows several differences, including adequacy of coverage of the base and conformity of the dosimetry around the apex. Given the advantage of MR-based tissue definition, further study of MR-based dosimetry is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Phase II Study of Submandibular Gland Transfer Prior to Radiation for Prevention of Radiation-induced Xerostomia in Head-and-Neck Cancer (RTOG 0244)

Purpose: We report the results of a phase II study to determine the reproducibility of a submandibular salivary gland transfer (SGT) surgical technique for prevention of radiation (XRT)-induced xerostomia in a multi-institutional setting and to assess severity of xerostomia. Methods and Materials: Eligible patients had surgery for primary, neck dissection, and SGT, followed by XRT, during which the transferred salivary gland was shielded. Intensity modulated radiation therapy, amifostine, and pilocarpine were not allowed, but postoperative chemotherapy was allowed. Each operation was reviewed by 2 reviewers and radiation by 1 reviewer. If 13 or more (of 43) were 'not per protocol,' then the technique would be considered not reproducible as per study design. The secondary endpoint was the rate of acute xerostomia, grade 2 or higher, and a rate of {<=}51% was acceptable. Results: Forty-four of the total 49 patients were analyzable: male (81.8%), oropharynx (63.6%), stage IV (61.4%), median age 56.5 years. SGT was 'per protocol' or within acceptable variation in 34 patients (77.3%) and XRT in 79.5%. Nine patients (20.9%) developed grade 2 acute xerostomia; 2 had grade 0-1 xerostomia (4.7%) but started on amifostine/pilocarpine. Treatment for these 11 patients (25.6%) was considered a failure for the xerostomia endpoint. Thirteen patients died; median follow-up for 31 surviving patients was 2.9 years. Two-year overall and disease-free survival rates were 76.4% and 71.7%, respectively. Conclusions: The technique of submandibular SGT is reproducible in a multicenter setting. Seventy-four percent of patients were prevented from XRT-induced acute xerostomia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetoelastic transition and magnetocaloric effect in induction melted Fe 100-x Rh x bulk alloys with x = 50, 51

Magnetoelastic transitions (METs) in bulk in nearly equiatomic Fe-Rh alloys produced by arc melting may show poor reproducibility related to insufficient chemical homogeneity and presence of impurity phases in variable concentrations. To better understand the synthesis conditions that reliably yield bulk FeRh materials with reproducible MET characteristics, Fe 100-x Rh x alloys with x = 50, 50.5 and 51 at. % were prepared by induction melting and thermal annealing under identical conditions. The fabricated samples were cut into several slices, followed by characterization of METs in each of the slices using isothermal and isofield magnetization measurements, differential scanning calorimetry, and direct measurements of the magnetocaloric effect. All of the slices exhibit METs between the AFM and FM states, but the transitions are abrupt with nearly the same change of magnetization, ΔM, when x = 50.5 and 51, whereas for the x = 50 alloy the transition spreads over a wide temperature interval and ΔM may fluctuate by as much as 10 % from one specimen to another. A comparison of the magnetocaloric responses of x = 50 and 51 materials is presented. The clearly different effect of the magnetic field on the transition in both directions leads to significant differences in the reversibility and maximum values of the magnetic field-induced entropy and adiabatic temperature changes, as well as average hysteresis losses. In terms of reproducibility, our results suggest that induction melting is a more appropriate technique to prepare these binary alloys.

36 MATERIALS SCIENCE↗

The controllable assembly of nanorods, nanowires and microwires of a perylenediimide molecule with photoswitching property

By using an electron donor–acceptor molecule that consists of a perylenediimide (PDI) core bonded with two ferrocene (Fc) units, well-defined nanorods, nanowires and microwires of PDI-Fc were formed through simply adjusting the initial concentration of PDI-Fc in dichloromethane or CH{sub 2}Cl{sub 2}. Moreover, the two-ended devices based on individual microwire were fabricated. Highly reproducible and sensitive photo response characteristics were demonstrated in the microwire through controlling the white light on and off with different light intensities. The assembly strategy via complementary donors and acceptors is of significance for constructing photoconductive systems and developing novel functional devices. - Graphical abstract: The two-ended devices based on individual microwire were fabricated. Highly reproducible and sensitive photo response characteristics were observed by controlling the white light on and off with different light intensities. - Highlights: • An electron donor–acceptor molecule (PDI-Fc) was synthesized. • Well-defined nanorods, nanowires and microwires of PDI-Fc were formed. • The two-ended devices based on individual microwire were fabricated. • Highly reproducible and sensitive photo response characteristics were observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent and its application

Graphical abstract: Electrochemical deposition of netlike gold nanoparticles (GNPs) on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The catalytic properties of netlike gold nanoparticles on the glassy carbon electrode for dopamine were demonstrated. The results indicate that the netlike gold nanoparticle modified electrode has an excellent repeatability and reproducibility. Display Omitted Highlights: ► Synthesis of netlike gold nanoparticles using ampicillin as a stabilizing reagent. ► Excellent repeatability and reproducibility of netlike gold nanoparticle modified glassy carbon electrode. ► The catalytic properties of netlike gold nanoparticle for dopamine. -- Abstract: Electrochemical deposition of netlike gold nanoparticles on the surface of glassy carbon electrode and preparation of netlike GNPs in aqueous solution using ampicillin as a stabilizing reagent were proposed. The netlike gold nanoparticles were characterized by scanning electron microscope, transmission electron microscope, infrared spectrometer, UV spectrophotometer, powder X-ray diffractometer and electrochemical analyzer. The catalysis of the netlike gold nanoparticles on the glassy carbon electrode for dopamine was demonstrated. The results indicate that the gold nanoparticle modified electrode has an excellent repeatability and reproducibility.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fragility correlates thermodynamic and kinetic properties of glass forming liquids

Graphical abstract: The suggested new fragility parameter correlates viscosity and configurational entropy. - Highlights: • A new fragility function, F=ΔT/ΔC{sub p}×C{sub p}{sup l}/T{sub g} has been proposed. • A three parameter viscosity function using the new F reproduces Angell fragility plot. • A new ΔC{sub p} function is derived which directly relates Adam–Gibbs function with the fragility based viscosity function. - Abstract: In our earlier communication we proposed a simple fragility determining function, ([NBO]/V{sub m}{sup 3}T{sub g}), which we have now used to analyze several glass systems using available thermal data. A comparison with similar fragility determining function, ΔC{sub p}/C{sub p}{sup l}, introduced by Chryssikos et al. in their investigation of lithium borate glasses has also been performed and found to be more convenient quantity for discussing fragilities. We now propose a new function which uses both ΔC{sub p} and ΔT and which gives a numerical fragility parameter, F whose value lies between 0 and 1 for glass forming liquids. F can be calculated through the use of measured thermal parameters ΔC{sub p}, C{sub p}{sup l}, T{sub g} and T{sub m}. Use of the new fragility values in reduced viscosity equation reproduces the whole range of viscosity curves of the Angell plot. The reduced viscosity equation can be directly compared with the Adam–Gibbs viscosity equation and a heat capacity function can be formulated which reproduces satisfactorily the ΔC{sub p} versus ln(T{sub r}) curves and hence the configurational entropy.

36 MATERIALS SCIENCE↗

Beams Arrangement in Non-Small Cell Lung Cancer (NSCLC) According to PTV and Dosimetric Parameters Predictive of Pneumonitis

The aim of this study is to propose and validate an original new class of solutions for three-dimensional conformal radiation therapy (3DCRT) treatment planning for non-small cell lung cancer (NSCLC) according to the different patterns of disease presentation (on the basis of tumor location and volume) and to explore beams arrangement (planar or no-planar solutions) to respect dose constraints to the lung parenchyma. Benchmarks matched to validate the new approach are interuser reproducibility and saving on planning time. Tumor location was explored and specific categories created according to the tumor volume and location. Therefore, by applying planar and no-planar 3D plans, we searched for an optimization of the beams arrangement for each category. Dose-volume histograms (DVHs) were analyzed and a plan comparison performed. Results were then validated (class solution planning confirmation) by applying the same strategy to another group of patients. This has been realized at two dose levels (50.4 and 59.4 Gy). Fifty-nine patients were enrolled in this dosimetric study. In the first 27 patients ('exploratory sample') three main planning target volume location categories were identified according to the pattern of the disease presentation: (1) centrally located; (2) peripheral T and mediastinal N (P+N); and (3) superior sulcus. Original class solutions were proposed for each location category. On the next 32 patients ('validation sample'), the treatment planning started directly with the recommended approach. Mean V{sub 20Gy} value was 18.8% (SD {+-} 7.25); mean V{sub 30Gy}:12% (SD {+-} 4.05); and mean lung dose: 11.6Gy (SD {+-} 5.77). No differences between the two total dose level groups were observed. These results suggest a simple and reproducible tool for treatment planning in NSCLC, allowing interuser reproducibility and cutting down on planning time.

61 RADIATION PROTECTION AND DOSIMETRY↗

Monitoring Linear Accelerator Output Constancy Using the PTW Linacheck

The PTW-Linacheck was assessed for its ability to monitor linear accelerator radiation output constancy. The key issues that were considered were the setup for daily output measurements, e.g., requirements for build-up and backscatter material, and the reproducibility and linearity of the device with linear accelerator output. An appropriate measurement setup includes a 10 x 10 cm field at 100 cm FSD, 5 cm backscatter, and no added build-up for 4 MeV electron beams, 1 cm added build-up for 6-16 MeV electron beams and 5 cm added build-up for 6-15 MV photon beams. Using this measurement setup, the dose linearity and short-term reproducibility were acceptable; however, the Linacheck should be recalibrated on a monthly basis to ensure acceptable long-term reproducibility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of responses of 2d array seven29 detector and its combined use with octavius phantom for the patient-specific quality assurance in rapidarc treatment delivery

A commercial 2D array seven29 detector has been characterized and its performance has been evaluated. 2D array ionization chamber equipped with 729 ionization chambers uniformly arranged in a 27 Multiplication-Sign 27 matrix with an active area of 27 Multiplication-Sign 27 cm{sup 2} was used for the study. An octagon-shaped phantom (Octavius Phantom) with a central cavity is used to insert the 2D ion chamber array. All measurements were done with a linear accelerator. The detector dose linearity, reproducibility, output factors, dose rate, source to surface distance (SSD), and directional dependency has been studied. The performance of the 2D array, when measuring clinical dose maps, was also investigated. For pretreatment quality assurance, 10 different RapidArc plans conforming to the clinical standards were selected. The 2D array demonstrates an excellent short-term output reproducibility. The long-term reproducibility was found to be within {+-}1% over a period of 5 months. Output factor measurements for the central chamber of the array showed no considerable deviation from ion chamber measurements. We found that the 2D array exhibits directional dependency for static fields. Measurement of beam profiles and wedge-modulated fields with the 2D array matched very well with the ion chamber measurements in the water phantom. The study shows that 2D array seven29 is a reliable and accurate dosimeter and a useful tool for quality assurance. The combination of the 2D array with the Octavius phantom proved to be a fast and reliable method for pretreatment verification of rotational treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗