Search NASA⌕ Search

SEARCH · Search NASA

Results for “START”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Newton-Raphson AC Power Flow Convergence Based on Deep Learning Initialization and Homotopy Continuation

Power flow forms the basis of many power system studies. With the increased penetration of renewable energy, grid planners tend to perform multiple power flow simulations under various operating conditions and not just selected snapshots at peak or light load conditions. Getting a converged AC power flow (ACPF) case remains a significant challenge for grid planners especially in large power grid networks. This paper proposes a two-stage approach to improve Newton-Raphson ACPF convergence and was applied to a 6102 bus Electric Reliability Council of Texas (ERCOT) system. The first stage utilizes a deep learning-based initializer with data re-training. Here a deep neural network (DNN) initializer is developed to provide better initial voltage magnitude and angle guesses to aid in power flow convergence. This is because Newton-Raphson ACPF is quite sensitive to the initial conditions and bad initialization could lead to divergence. The DNN initializer includes a data re-training framework that improves the initializer's performance when faced with limited training data. The DNN initializer successfully solved 3,285 cases out of 3,899 non-converging dispatch and performed better than random forest and DC power flow initialization methods. ACPF cases not solved in this first stage are then passed through a hot-starting algorithm based on homotopy continuation with switched shunt control. The hot-starting algorithm successfully converged 416 cases out of the remaining 614 non-converging ACPF dispatch. In conclusion, the combined two-stage approach achieved a 94.9% success rate, by converging a total of 3,701 cases out of the initial 3,899 unsolved cases.

Deep learning↗

Simulating evaporative wet and dry cycles in Gale crater, Mars using thermochemical modeling techniques

The aim of this work is to provide a model‐backed hypothesis for the formation of evaporites—sulfates, borates—in Gale crater using thermochemical modeling to determine constraints on their formation. We test the hypothesis that primary evaporites required multiple wet–dry cycles to form, akin to how evaporite assemblages form on Earth. Starting with a basalt‐equilibrated Mars fluid, Mars‐relevant concentrations of B and Li were added, and then equilibrated with Gale lacustrine bedrock. We simulated the cycles of evaporation followed by groundwater recharge/dilution to establish an approximate minimum number of wet–dry cycles required to form primary evaporites. We determine that a minimum of 250 wet–dry cycles may be required to start forming primary evaporites that consist of borates and Ca‐sulfates. We estimate that ~14,250 annual cycles (~25.6 k Earth years) of wet and dry periods may form primary borates and Ca‐sulfates in Gale crater. These primary evaporites could have been remobilized during secondary diagenesis to form the veins that the Curiosity rover observes in Gale crater. No Li salts form after 14,250 cycles modeled for the Gale‐relevant scenario (approximately 10 6 cycles would be needed) which implies Li may be leftover in a groundwater brine after the time of the lake. No major deposits of borates are observed to date in Gale crater which also implies that B may be leftover in the subsequent groundwater brine that formed after evaporites were remobilized into Ca‐sulfate veins.

58 GEOSCIENCES↗

Stochastic Approximation for Multi-period Simulation Optimization with Streaming Input Data

We consider a continuous-valued simulation optimization (SO) problem, where a simulator is built to optimize an expected performance measure of a real-world system while parameters of the simulator are estimated from streaming data collected periodically from the system. At each period, a new batch of data is combined with the cumulative data and the parameters are re-estimated with higher precision. The system requires the decision variable to be selected in all periods. Therefore, it is sensible for the decision-maker to update the decision variable at each period by solving a more precise SO problem with the updated parameter estimate to reduce the performance loss with respect to the target system. We define this decision-making process as the multi-period SO problem and introduce a multi-period stochastic approximation (SA) framework that generates a sequence of solutions. Two algorithms are proposed: Re-start SA (ReSA) reinitializes the stepsize sequence in each period, whereas Warm-start SA (WaSA) carefully tunes the stepsizes, taking both fewer and shorter gradient-descent steps in later periods as parameter estimates become increasingly more precise. We show that under suitable strong convexity and regularity conditions, ReSA and WaSA achieve the best possible convergence rate in expected sub-optimality either when an unbiased or a simultaneous perturbation gradient estimator is employed, while WaSA accrues significantly lower computational cost as the number of periods increases. In addition, we present the regularized ReSA, which obviates the need to know the strong convexity constant and achieves the same convergence rate at the expense of additional computation.

Computer Science↗

RESCue Model (RESCue Experiment and Model) [SWR-24-84]

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of transmission-connected hybrid renewable energy systems, consisting of a combination of wind, solar, and/or energy storage equipment, against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. The development of hybrid reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. The research thrusts for the project included (i) development of hybrid reference architectures and (ii) a cyber-resilient design framework for hybrid energy systems. The reference architectures has provided comprehensive blueprints for the secure design and integration of hybrid renewable energy systems, accounting for their unique characteristics and interdependencies. Additionally, NREL has created a cyber-resilient design framework that integrates cybersecurity considerations from the start of the system lifecycle, ensuring security is "baked in" from the initial design phase. A demonstration experiment was developed for one of the architectures using NREL's Cyber Range resources. This experiment configuration, deployable using open-source tools, is provided here in this repository. Additional models were developed for the wind and solar architectures as well, however the configurations for only the Energy Storage scenario are provided here: https://www.nrel.gov/docs/fy24osti/89921.pdf

Hasandka, Adarsh↗

infrastore [SWR-26-077]

Infrastore is time-series storage for energy-systems simulations, backed by HDF5 + SQLite, with Rust, Python, Julia, gRPC, and CLI bindings. It is a Rust library for managing time-series data in power-systems and energy simulations. Numerical arrays are persisted in HDF5, and the metadata associating each array with its owning component lives in SQLite. Identical arrays are stored once and shared through content addressing. It ships native Rust, Python (PyO3), and Julia (C ABI) interfaces, the infrastore command-line tool, and a read-only gRPC server with a Rust client. Documentation: https://natlabrockies.github.io/infrastore/latest/ — start with the Quick Start or the Architecture.

Thom, Daniel [National Laboratory of the Rockies (↗

ReachNow EV Driving Data From Seattle, WA, Portland, OR, and New York, NY

ReachNow provided Idaho National Laboratory (INL) with a dataset describing approximately 49,000 trips taken by customers and employees in approximately 100 BMW i3 EVs operating in ReachNow's free-floating car-sharing fleets in Seattle, WA, Portland, OR, and New York, NY between May 2016 and February 2017. Data fields include vehicle rental period start and end timestamps, the location where vehicles were parked at the start and end of rental periods, and distance driven during rental periods. A field categorizing the user during each rental period is also included. This field makes it possible to identify when vehicles were rented by customers and when vehicles were driven by fleet management team employees to reposition, charge, or service the vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raw_data_Batch_I: Ashland Avenue

Date of collection: May 26, 2023 Location: Ashland Avenue, Chicago, IL This data set contains lidar and vision data collected along Ashland Avenue. A south-to-north run starts from the intersection of Irving Park and Ashland and ends at Andersonville Garden. A north-to-south run starts from Andersonville Garden and ends around the intersection of Irving Park and Ashland. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![ashland avenue image](ashland-avenue.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raw_data_Batch_I: Lakeshore Drive

Date of collection: May 18, 2023 Location: Lakeshore Drive, Chicago, IL Content: “North to South” “South to North” This data set contains lidar and vision data collected along Lakeshore Drive. The “South to North” folder starts from the intersection of Lakeshore Drive and 31st Street and ends at Hollywood Towers Chicago. The “North to South” folder starts from the intersection of Lakeshore Drive and Sheridan Avenue and ends at the 31st Street intersection. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![lakeshore drive image](lakeshore-drive.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Raw_data_Batch_I: Randall Road

Date of collection: June 3, 2022 Location: Randall Road, DuPage County, IL Content: “North to South” “South to North” This data set contains lidar and vision data collected along Randall Road in DuPage County, Illinois. The “South to North” folder starts at 1480 N. Orchard Road, Aurora, IL 60506, headed north along Randall Road until 238 N. Randall Road, St. Charles, IL 60174. The “North to South” folder starts from 238 N. Randall Road, St. Charles, IL 60174, headed south along Randall Road until 1480 N. Orchard Road, Aurora, IL. The data contains the following Robot Operating System (ROS) topics: - /Central_Camera_blurred – Image flow from coaxial camera heading, vehicle front. - /Left_Camera_blurred – Image flow from left camera, 60° from central camera on the left side. - /Right_Camera_blurred – Image flow from right camera, 60° from central camera on the right side. - /camera0/camera_info – Intrinsic and distortion information of left camera. - /camera0/projection_matrix – Extrinsic matrix of left camera from lidar. - /camera2/camera_info – Intrinsic and distortion information of central camera. - /camera2/projection_matrix – Extrinsic matrix of central camera from lidar. - /camera5/camera_info – Intrinsic and distortion information of right camera. - /camera5/projection_matrix – Extrinsic matrix of right camera from lidar. - /novatel/oem7/bestpos – Latitude, longitude, and elevation information from NovAtel GNSS-INS system. - /points_raw – VLP-32 lidar point cloud. - /tf – Vehicle base frame. The data are organized into a data description file and one or more ROS .bag files, dependent on original file size. The data description file provides information about the data collection date, location, and detailed mapping, while the .bag file(s) contain the actual data. Please note that for the purpose of securing personally identifiable information, all license plates and faces included in this publication have been intentionally blurred during real-time processing. ![randall road image](randall-road.png)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GSE Yearly Load Profiles for Each Airport Under Six Charging Scenarios

This dataset contains GSE yearly load profiles for each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse_load_profile_sample_day.png) GSE load profile of a sample day across different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charger Requirements for GSE at Each Airport

This dataset contains the required number of chargers for GSE at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fleet Size Requirements for Each GSE Type at Each Airport

This dataset contains the required number of vehicles for each GSE type at each airport under six charging scenarios: (1) charging when the battery state of charge is insufficient for the next service using 40-kW chargers (S1); (2) charging when the battery state of charge is insufficient for the next service using 20-kW chargers (S2); (3) charging starts immediately after each GSE completes a service task using 40-kW chargers (S3); (4) charging starts immediately after each GSE completes a service task using 20-kW chargers (S4); (5) charging during off-peak hours using 40-kW chargers (S5); and (6) charging during off-peak hours using 20-kW chargers (S6). ![image](gse-vehicles-chargers.png) Number of GSE vehicles per GSE type and chargers required for different airport categories under charging scenario 1.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cation Data for the East River Watershed, Colorado (2014-2025)

This data package contains mean values for cation concentration for water samples taken from the East River Watershed in Colorado. Inductively coupled plasma mass spectrometry (ICP-MS) has been used to measure the concentrations of elements of interest simultaneously for the East River Watershed, Colorado groundwater and surface water samples to inform insights on the biogeochemistry processes within the watershed. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. For samples collected prior to 06-16-2021, the instrumentation, Elan DRC II, PerkinElmer SCIEX, automatically switches among the three models necessary to analyze all 37 elements. These 37 elements include: (1) Lithium (Li), Beryllium (Be), Boron (B), Sodium (Na), Magnesium (Mg), Aluminium (Al), Silicon (Si), Phosphorus (P), Titanium (Ti), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Caesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th), Uranium (U) using standard model, argon Ar as reaction gas, (2) Potassium (K), Calcium (Ca), Vanadium (V), Chromium (Cr), Manganese (Mn), Iron (Fe) using dynamic reaction cell (DRC) model, ammonia NH3 as reaction gas, and (3) Phosphorus (P) and Selenium (Se) using DRC model, oxygen O2 as reaction gas. Note for the samples with higher concentrations of chloride (Cl-), asenic (As) concentrations were analysed with DRC model (oxygen O2 as reaction gas) to avoid the interference of chloride. For samples collected on and after 06-16-2021, an advanced Agilent 8900 triple quadrupole inductively coupled plasma mass spectrometry system (Agilent 8900 QQQ ICP-MS, Agilent Technologies) has been used to measure the concentrations of interested 36 elements simultaneously for environmental samples, including (1) Lithium (Li), Beryllium (Be) and Boron (B) using standard no gas mode, (2) Sodium (Na), Magnesium (Mg), Aluminium (Al) Phosphorus (P), Potassium (K), Chromium (Cr), Manganese (Mn), Iron (Fe), Cobalt (Co), Nickel (Ni), Copper (Cu), Zinc (Zn), Germanium (Ge), Arsenic (As), Rubidium (Rb), Strontium (Sr), Zirconium (Zr), Molybdenum (Mo), Silver (Ag), Cadmium (Cd), Tin (Sn), Antimony (Sb), Cesium (Cs), Barium (Ba), Europium (Eu), Lead (Pb), Thorium (Th) and Uranium (U) using standard helium (He) collision mode, (3) Titanium (Ti) and Vanadium (V) using high Energy (HEHe) helium (He) collision mode, and (4) Silicon (Si), Calcium (Ca) and Selenium (Se) using standard H2 reaction mode. All samples were prepared/diluted with 2% (v/v) ultrapure nitric acid in Milli-Q water (18.2 mega ohm-cm), and analyzed under a rigorous quality assurance and quality control (QA/QC) process. This data package contains (1) a zip file (cation_data_2014_2025.zip) containing a total of 5,849 files: 5.848 data files of cation data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v6_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v6_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the detemination of Method Detection Limits (MDLs) for ICP-MS PerkinElmer DRC II instrumentation (Detemination_of_Method_Detection_Limits__MDLs__for_ICP_MS__PerkinElmer_Elan_DRC_II__LBL_Bldg74_Lab214D) for samples before November 2021; (5) PDF and docx files for the determination of MDLs for ICP-MS Agilent 8900 QQQ instrumentation (ICP_MS_Analysis_detection_limits_and_QA_QC_WenmingDong_updated_2026-08-06) for samples November 2021 and onward. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 113 locations containing cation data. Update on 2021-04-11: Added Detemination of Method Detection Limits (MDLs) for ICP-MS document, which can be accessed as a PDF or with Microsoft Word. Update on 2022-06-10: versioned updates to this dataset was made along with these changes: (1) updated cation data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) removed suffix and prefix on two variables (“aqberylliumion_asberyllium” and “aqlithiumion_aslithium”), (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-16. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Updated versions of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available cation data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-06, of the PDF and docx files for determination of MDLs for ICP-MS data were added to this dataset for samples starting in November 2021.

54 ENVIRONMENTAL SCIENCES↗

Meteorological Conditions in Urban Sites in Knoxville, USA. 2025

This 2025 dataset, which contains five csv files, reports hourly air temperature, wind speed, solar radiation, incident short wave, reflected short wave, incident long wave, emitted long wave, net radiation, and photosynthetically active radiation (PAR) data measured in urban parks in Knoxville, Tennessee, USA. The sites include Cumberland Estates Park (CEP), Socially Equal Energy Efficient Development (SEEED), West Hills Park (WHP), West View Park (WVP), and Victor Ashe Park (VAP). Air temperature, wind speed, and solar radiation data were obtained from a METER ATMOS 41 All-in-One Weather Station (Pullman, Washington, USA). Incident and emitted radiation (shortwave and longwave) measurements were made using an Apogee (Logan, Utah, USA) net radiometer (Model SN-500-SS). The SQ-521 Full-Spectrum Quantum sensor (Apogee Instruments, Inc) recorded the PAR. The measurement data for all the sites started on January 1, 2025. and all measurement ended on December 31, 2025. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

Salvador, Christian [ORNL] (ORCID:0000000283287777↗

Zero-CO Residential Natural Gas Furnace

Residential natural gas furnaces are widely used in the US homes. Manufacturers dedicate significant design and testing resources to meet requirements of design standards. One area of these standards is controlling flue gas carbon monoxide (CO) emissions. To more effectively reduce CO emissions at the flue, we developed a novel catalyst-assisted approach that integrated a low Pt/Rh loading acidic gas reduction (AGR) catalyst with three-way catalyst (TWC) or diesel oxidation catalyst (DOC) components. Compact catalysts were fabricated and assembled into tubular components, which can be seamlessly incorporated into the primary heat exchanger of a representative commercially available condensing furnace. The retrofitted furnace was demonstrated and tested following ANSI/ASHRAE Standard 103-2017. Experimental results showed that both AGR/TWC and AGR/DOC configurations achieved near-zero CO emissions under steady-state and cold-start conditions, compared with up to 500 ppm at a cold start and 17 ppm in a steady state in the OEM furnace. The catalyst-assisted furnaces also exhibited an annual fuel utilization efficiency improvement of more than 1.5% relative to the baseline unit, with a manageable pressure drop of 2.0−2.5 in. of water column. These results demonstrate that the catalyst-assisted approach can effectively eliminate CO emissions and improve energy efficiency. The technology has broad applicability for residential and commercial gas-fired heating systems.

Gao, Zhiming [ORNL] (ORCID:0000000271397995)↗

AmeriFlux FLUXNET-1F US-Dmg Dutch Slough Marsh Gilbert Tract

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Dmg Dutch Slough Marsh Gilbert Tract. This is the FLUXNET version of the carbon flux data for the site US-Dmg Dutch Slough Marsh Gilbert Tract produced by applying the standard ONEFlux (1F) software. Site Description - A new restored tidal freshwater wetland located on the west Delta, within Oakley, CA. The tower is located in the eastern side of the Gilbert Parcel seeing the mid marsh transition zone upwind. Restoration work is done by DWR and started in 2018, revegetation planting started in late 2019, followed by tidal action restoration in October 2021.

Arias-Ortiz, Ariane↗

Adjoint Waveform Tomography for Crustal and Upper Mantle Structure of the Middle East and Southwest Asia for Improved Waveform Simulations Using Openly Available Broadband Data

Here we present a new model of radially anisotropic seismic wavespeeds for the crust and upper mantle of a broad region of the Middle East and Southwest Asia (MESWA) derived from adjoint waveform tomography. The new model enables fully 3D simulations of complete three-component waveforms and provides improved fits that were not possible with previous models. We inverted over 32,000 waveforms from 192 earthquakes recorded by over 1000 openly available broadband seismic stations from permanent and temporary networks in the region with highly uneven coverage. Inversion iterations proceeded from the period band 50–100 s in six stages and 54 total iterations reducing the minimum period to 30 s. Our final model, MESWA, improves waveform fits compared to the starting and other models for both the data used in the inversion and an independent validation set of 66 events. Restitution tests indicate that the model resolves features in the central part of the model to depths of about 150 km. The new model reveals tectonic features imaged by other studies and methods but in a new holistic model of anisotropic shear and compressional wavespeeds (V S and V P , respectively) covering a larger domain with smaller scale length and amplified features. Examples include low crustal V S in the Tethyan belt and low mantle VS following divergent (Gulf of Aden, Red Sea) and transform (Dead Sea fault) margins of the Arabian plate. Low V S is imaged below Cenozoic volcanic centers of the Mecca–Madina–Nafud Line, Arabian Peninsula, and the Türkiye–Iran border region. Elevated V S tracks Makran subduction under southeast Iran with near vertical dip. MESWA could be used as a starting model for further improvements, say, using waveforms from in-country seismic networks that are not currently openly available and/or smaller-scale studies targeting a shorter period. The model could be used to improve earthquake hazard studies and nuclear explosion monitoring.

58 GEOSCIENCES↗

Universal Injector at LERF – Baseline Design

A new electron injector complex has been proposed within the Low Energy Recirculating Facility (LERF) vault, which would serve both the 22 GeV CEBAF and the positron programs, while being compatible with the electron source required to produce positrons for Ce+BAF. The baseline design of a 3-pass recirculator features a main linac configured with three cryomodules, five isochronous arcs and three straight sections, allowing electron beam acceleration up to 650 MeV. The injector offers the flexibility to extract 1-pass and 2-pass energy electrons, as needed for positron production, with final reconfiguration to a 3-pass 650 MeV injector for 22 GeV CEBAF. This paper provides an overview of the baseline design of the Universal injector complex, including the 8 MeV injector and the recirculator. A comprehensive suite of beam dynamics studies to validate our design is being launched, starting with start-to-end tracking with Elegant followed by the orbit correction and error mitigation.

Bogacz, A. [Thomas Jefferson National Accelerator ↗