Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Dynamic Importance Sampling

Dynamic Importance (DynIm) Sampling is a new approach for importance sampling in high-dimensional space. DynIm has two key characteristics. (1) Importance sampling: The notion of importance of candidate samples is used to guide the sampling, where importance is defined based on the (dis)similarity from previously selected samples (via Euclidean distance metric). (2) Dynamic sampling: The sampling can be performed dynamically, as new candidates are generated and new samples must be selected. DynIm was developed as part of a machine learning based coupling of scales in large multiscale simulations and can be used for a variety of applications.

Bhatia, Harsh↗

High quality copy number and genotype data from FFPE samples using Molecular Inversion Probe (MIP) microarrays

A major challenge facing DNA copy number (CN) studies of tumors is that most banked samples with extensive clinical follow-up information are Formalin-Fixed Paraffin Embedded (FFPE). DNA from FFPE samples generally underperforms or suffers high failure rates compared to fresh frozen samples because of DNA degradation and cross-linking during FFPE fixation and processing. As FFPE protocols may vary widely between labs and samples may be stored for decades at room temperature, an ideal FFPE CN technology should work on diverse sample sets. Molecular Inversion Probe (MIP) technology has been applied successfully to obtain high quality CN and genotype data from cell line and frozen tumor DNA. Since the MIP probes require only a small ({approx}40 bp) target binding site, we reasoned they may be well suited to assess degraded FFPE DNA. We assessed CN with a MIP panel of 50,000 markers in 93 FFPE tumor samples from 7 diverse collections. For 38 FFPE samples from three collections we were also able to asses CN in matched fresh frozen tumor tissue. Using an input of 37 ng genomic DNA, we generated high quality CN data with MIP technology in 88% of FFPE samples from seven diverse collections. When matched fresh frozen tissue was available, the performance of FFPE DNA was comparable to that of DNA obtained from matched frozen tumor (genotype concordance averaged 99.9%), with only a modest loss in performance in FFPE. MIP technology can be used to generate high quality CN and genotype data in FFPE as well as fresh frozen samples.

59 BASIC BIOLOGICAL SCIENCES↗

SALTSTONE VAULT CLASSIFICATION SAMPLES MODULAR CAUSTIC SIDE SOLVENT EXTRACTION UNIT/ACTINIDE REMOVAL PROCESS WASTE STREAM APRIL 2011

Savannah River National Laboratory (SRNL) was asked to prepare saltstone from samples of Tank 50H obtained by SRNL on April 5, 2011 (Tank 50H sampling occurred on April 4, 2011) during 2QCY11 to determine the non-hazardous nature of the grout and for additional vault classification analyses. The samples were cured and shipped to Babcock & Wilcox Technical Services Group-Radioisotope and Analytical Chemistry Laboratory (B&W TSG-RACL) to perform the Toxic Characteristic Leaching Procedure (TCLP) and subsequent extract analysis on saltstone samples for the analytes required for the quarterly analysis saltstone sample. In addition to the eight toxic metals - arsenic, barium, cadmium, chromium, mercury, lead, selenium and silver - analytes included the underlying hazardous constituents (UHC) antimony, beryllium, nickel, and thallium which could not be eliminated from analysis by process knowledge. Additional inorganic species determined by B&W TSG-RACL include aluminum, boron, chloride, cobalt, copper, fluoride, iron, lithium, manganese, molybdenum, nitrate/nitrite as Nitrogen, strontium, sulfate, uranium, and zinc and the following radionuclides: gross alpha, gross beta/gamma, 3H, 60Co, 90Sr, 99Tc, 106Ru, 106Rh, 125Sb, 137Cs, 137mBa, 154Eu, 238Pu, 239/240Pu, 241Pu, 241Am, 242Cm, and 243/244Cm. B&W TSG-RACL provided subsamples to GEL Laboratories, LLC for analysis for the VOCs benzene, toluene, and 1-butanol. GEL also determines phenol (total) and the following radionuclides: 147Pm, 226Ra and 228Ra. Preparation of the 2QCY11 saltstone samples for the quarterly analysis and for vault classification purposes and the subsequent TCLP analyses of these samples showed that: (1) The saltstone waste form disposed of in the Saltstone Disposal Facility in 2QCY11 was not characteristically hazardous for toxicity. (2) The concentrations of the eight RCRA metals and UHCs identified as possible in the saltstone waste form were present at levels below the UTS. (3) Most of the inorganic species measured in the leachate do not exceed the MCL, SMCL or TW limits. (4) The inorganic waste species that exceeded the MCL by more than a factor of 10 were nitrate, nitrite and the sum of nitrate and nitrite. (5) Analyses met all quality assurance specifications of US EPA SW-846. (6) The organic species (benzene, toluene, 1-butanol, phenol) were either not detected or were less than reportable for the vault classification samples. (7) The gross alpha and radium isotopes could not be determined to the MCL because of the elevated background which raised the detection limits. (8) Most of the beta/gamma activity was from 137Cs and its daughter 137mBa. (9) The concentration of 137Cs and 90Sr were present in the leachate at concentrations 1/40th and 1/8th respectively than in the 2003 vault classification samples. The saltstone waste form placed in the Saltstone Disposal Facility in 2QCY11 met the SCHWMR R.61-79.261.24(b) RCRA metals requirements for a nonhazardous waste form. The TCLP leachate concentrations for nitrate, nitrite and the sum of nitrate and nitrite were greater than 10x the MCLs in SCDHEC Regulations R.61-107.19, Part I A, which confirms the Saltstone Disposal Facility classification as a Class 3 Landfill. The saltstone waste form placed in the Saltstone Disposal Facility in 2QCY11 met the R.61-79.268.48(a) non wastewater treatment standards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hydraulic Conductivity of Saltstone Formulated Using 1Q11, 2Q11 and 3Q11 Tank 50 Slurry Samples

As part of the Saltstone formulation work requested by Waste Solidification Engineering (WSE), Savannah River National Laboratory (SRNL) was tasked with preparing Saltstone samples for fresh property analysis and hydraulic conductivity measurements using actual Tank 50 salt solution rather than simulated salt solution. Samples of low level waste salt solution collected from Tank 50H during the first, second, and third quarters of 2011 were used to formulate the Saltstone samples. The salt solution was mixed with premix (45 wt % slag, 45 wt % fly ash, and 10 wt % cement), in a ratio consistent with facility operating conditions during the quarter of interest. The fresh properties (gel, set, bleed) of each mix were evaluated and compared to the recommended acceptance criteria for the Saltstone Production Facility. ASTM D5084-03, Method C was used to measure the hydraulic conductivity of the Saltstone samples. The hydraulic conductivity of Saltstone samples prepared from 1Q11 and 2Q11 samples of Tank 50H is 4.2E-9 cm/sec and 2.6E-9 cm/sec, respectively. Two additional 2Q11 and one 3Q11 sample were not successfully tested due to the inability to achieve stable readings during saturation and testing. The hydraulic conductivity of the samples made from Tank 50H salt solution compare well to samples prepared with simulated salt solution and cured under similar conditions (1.4E-9 - 4.9E-8 cm/sec).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Sampling Inlets for Continuous Air Monitors in Calm Air Conditions

The Canberra NetCAM (networked continuous air monitor) can be operated with a radial inlet attachment from the manufacturer. Sampled aerosol can be transported through large diameter tubing from a desired location to the NetCAM sampler. In this assessment, the effect of the addition of the radial inlet was investigated. Also, a sampling system consisting of a vertical sample tube and a 90-degree elbow (to the horizontal plane) was evaluated by empirical calculations with the DEPO software. Generalized aspiration ratio calculations were done with the empirical model from Vincent. Three different sample probe types were also experimentally tested. In summary: (1) For typical room air conditions, the addition of the Canberra inline adapter to the NetCAM has no discernible effect on system performance. This was determined by literature search with a previously published study. (2) The DEPO software (US NRC / Texas A&M University) was used to show the effect of adding a 2-meter high vertical tube and a ninety-degree tube bend to a sampling inlet. In this example, there was a total penetration of 97.7% of 10-micron diameter aerosol particles for an air flowrate of 2.0 ACFM (actual cubic feet per minute). (3) Calculations of nozzle aspiration ratio (for general, non-specific situations) were performed using the Vincent empirical model. For example, in typical room air, where the average velocity is less than 0.5 m/sec, an aerosol inlet probe has a calculated aspiration ratio (or penetration efficiency) value between 98 and 100%, depending on the angle of the probe inlet compared to the direction of the incoming air velocity vector. A table of nozzle aspiration ratios was generated for a range of different room air velocities and probe inlet angles. (4) Three different candidate probe geometries were tested, (A) a probe with a vertical entry and vertical transport tube, (B) a probe with a horizontal entry and vertical transport tube, and (C) a ‘widemouth’ probe with a vertical entry and vertical transport tube. The experimentally determined values were 98%, 102%, and 100%, respectively, for the aerosol penetration into these inlets. In conclusion, the addition of a complete sampling system with probe inlet, a short length of sampling lines and the radial inlet would still be able to deliver about 95% of the sampled aerosol from the sampling location to the Canberra NetCAM.

61 RADIATION PROTECTION AND DOSIMETRY↗

Analysis Of 2h-Evaporator Scale Wall [HTF-13-82] And Pot Bottom [HTF-13-77] Samples

Savannah River Remediation (SRR) is planning to remove a buildup of sodium aluminosilicate scale from the 2H-evaporator pot by loading and soaking the pot with heated 1.5 M nitric acid solution. Sampling and analysis of the scale material has been performed so that uranium and plutonium isotopic analysis can be input into a Nuclear Criticality Safety Assessment (NCSA) for scale removal by chemical cleaning. Historically, since the operation of the Defense Waste Processing Facility (DWPF), silicon in the DWPF recycle stream combines with aluminum in the typical tank farm supernate to form sodium aluminosilicate scale mineral deposits in the 2Hevaporator pot and gravity drain line. The 2H-evaporator scale samples analyzed by Savannah River National Laboratory (SRNL) came from the bottom cone sections of the 2H-evaporator pot [Sample HTF-13-77] and the wall 2H-evaporator [sample HTF-13-82]. X-ray diffraction analysis (XRD) confirmed that both the 2H-evaporator pot scale and the wall samples consist of nitrated cancrinite (a crystalline sodium aluminosilicate solid) and clarkeite (a uranium oxy-hydroxide mineral). On “as received” basis, the bottom pot section scale sample contained an average of 2.59E+00 ± 1.40E-01 wt % total uranium with a U-235 enrichment of 6.12E-01 ± 1.48E-02 %, while the wall sample contained an average of 4.03E+00 ± 9.79E-01 wt % total uranium with a U-235 enrichment of 6.03E-01% ± 1.66E-02 wt %. The bottom pot section scale sample analyses results for Pu-238, Pu-239, and Pu-241 are 3.16E- 05 ± 5.40E-06 wt %, 3.28E-04 ± 1.45E-05 wt %, and <8.80E-07 wt %, respectively. The evaporator wall scale samples analysis values for Pu-238, Pu-239, and Pu-241 averages 3.74E-05 ± 6.01E-06 wt %, 4.38E-04 ± 5.08E-05 wt %, and <1.38E-06 wt %, respectively. The Pu-241 analyses results, as presented, are upper limit values. These results are provided so that SRR can calculate the equivalent uranium-235 concentrations for the NCSA. Results confirm that the uranium contained in the scale remains depleted with respect to natural uranium. SRNL did not calculate an equivalent U-235 enrichment, which takes into account other fissionable isotopes U-233, Pu-239 and Pu-241. The applicable method for calculation of equivalent U-235 will be determined in the NCSA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of stainless steel canister corrosion studies and environmental sample investigations

This progress report describes work being done at Sandia National Laboratories (SNL) to assess the localized corrosion performance of container/cask materials used in the interim storage of used nuclear fuel. The work involves both characterization of the potential physical and chemical environment on the surface of the storage canisters and how it might evolve through time, and testing to evaluate performance of the canister materials under anticipated storage conditions. To evaluate the potential environment on the surface of the canisters, SNL is working with the Electric Power Research Institute (EPRI) to collect and analyze dust samples from the surface of in-service SNF storage canisters. In FY 13, SNL analyzed samples from the Calvert Cliffs Independent Spent Fuel Storage Installation (ISFSI); here, results are presented for samples collected from two additional near-marine ISFSI sites, Hope Creek NJ, and Diablo Canyon CA. The Hope Creek site is located on the shores of the Delaware River within the tidal zone; the water is brackish and wave action is normally minor. The Diablo Canyon site is located on a rocky Pacific Ocean shoreline with breaking waves. Two types of samples were collected: SaltSmart™ samples, which leach the soluble salts from a known surface area of the canister, and dry pad samples, which collected a surface salt and dust using a swipe method with a mildly abrasive ScotchBrite™ pad. The dry samples were used to characterize the mineralogy and texture of the soluble and insoluble components in the dust via microanalytical techniques, including mapping X-ray Fluorescence spectroscopy and Scanning Electron Microscopy. For both Hope Creek and Diablo Canyon canisters, dust loadings were much higher on the flat upper surfaces of the canisters than on the vertical sides. Maximum dust sizes collected at both sites were slightly larger than 20 μm, but Phragmites grass seeds ~1 mm in size, were observed on the tops of the Hope Creek canisters. At both sites, the surface dust could be divided into fractions generated by manufacturing processes and by natural processes. The fraction from manufacturing processes consisted of variably-oxidized angular and spherical particles of stainless steel and iron, generated by machining and welding/cutting processes, respectively. Dust from natural sources consisted largely of detrital quartz and aluminosilicates (feldspars and clays) at both sites. At Hope Creek, soluble salts were dominated by sulfates and nitrates, mostly of calcium. Chloride was a trace component and the only chloride mineral observed by SEM was NaCl. Chloride surface loads measured by the Saltsmart™ sensors were very low, less than 60 mg m –2 on the canister top, and less than 10 mg m –2 on the canister sides. At Diablo Canyon, sea-salt aggregates of NaCl and Mg-SO 4 , with minor K and Ca, were abundant in the dust, in some cases dominating the observed dust assemblage. Measured Saltsmart™ chloride surface loads were very low (<5 mg m –2 ); however, high canister surface temperatures damaged the Saltsmart™ sensors, and, in view of the SEM observations of abundant sea-salts on the package surfaces, the measured surface loads may not be valid. Moreover, the more heavily-loaded canister tops at Diablo Canyon were not sampled with the Saltsmart™ sensors. The observed low surface loads do not preclude chloride-induced stress corrosion cracking (CISCC) at either site, because (1) the measured data may not be valid for the Diablo Canyon canisters; (2) the surface coverage was not complete (for instance, the 45º offset between the outlet and inlet vents means that near-inlet areas, likely to have heavier dust and salt loads, were not sampled); and (3) CISCC has been experimentally been observed at salt loads as low as 5-8 mg/m 2 . Experimental efforts at SNL to assess corrosion of interim storage canister materials include three tasks in FY14. First, a full-diameter canister mockup, made using materials and techniques identical to those used to make interim storage canisters, was designed and ordered from Ranor Inc., a cask vendor for Areva/TN. The mockup will be delivered prior to the end of FY14, and will be used for evaluating weld residual stresses and degrees of sensitization for typical interim storage canister welds. Following weld characterization, the mockup will be sectioned and provided to participating organizations for corrosion testing purposes. A test plan is being developed for these efforts. In a second task, experimental work was carried out to evaluate crevice corrosion of 304SS in the presence of limited reactants, as would be present on a dustcovered storage canister. This work tests the theory that limited salt loads will limit corrosion penetration over time, and is a continuation of work carried out in FY13. Laser confocal microscopy was utilized to assess the volume and depth of corrosion pits formed during the crevice corrosion tests. Results indicate that for the duration of the current experiments (100 days), no stifling of corrosion occurred due to limitations in the amount of reactants present at three different salt loadings. Finally, work has been carried out this year perfecting an instrument for depositing sea-salts onto metal surfaces for atmospheric corrosion testing purposes. The system uses an X-Y plotter system with a commercial airbrush, and deposition is monitored with a quartz crystal microbalance. The system is capable of depositing very even salt loadings, even at very low total deposition rates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Results for the first quarter calendar year 2017 tank 50H salt solution sample

In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Addendum to Sampling and Analysis Plan (SAP) for Assessment of LANL-Derived Residual Radionuclides in Soils within Tract A-16-d for Land Conveyance and Transfer for Sewage Treatment Facility Area

This report summarizes the sampling design used, associated statistical assumptions, as well as general guidelines for conducting post-sampling data analysis. Sampling plan components presented here include how many sampling locations to choose and where within the sampling area to collect those samples. The type of medium to sample (i.e., soil, groundwater, etc.) and how to analyze the samples (in-situ, fixed laboratory, etc.) are addressed in other sections of the sampling plan.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Samples Collected from the Surface of Interim Storage Canisters at Calvert Cliffs in June 2017: Revision 01.

In June 2017, dust and salt samples were collected from the surface of Spent Nuclear Fuel (SNF) dry storage canisters at the Calvert Cliffs Nuclear Power Plant. The samples were delivered to Sandia National laboratories for analysis. Two types of samples were collected: filter-backed Scotch-Brite TM pads were used to collect dry dust samples for characterization of salt and dust morphologies and distributions; and Saltsmart TM test strips were used to collect soluble salts for determining salt surface loadings per unit area. After collection, the samples were sealed into plastic sleeves for shipping. Condensation within the sleeves containing the Scotch-Brite TM samples remobilized the salts, rendering them ineffective for the intended purpose, and also led to mold growth, further compromising the samples; for these reasons, the samples were not analyzed. The SaltSmart TM samples were unaffected and were analyzed by ion chromatography for major anions and cations. The results of those analyses are presented here.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Identification and Shipment Progress of the INL and LANL Samples to Be Received at ORNL

Ferritic-martensitic steel Grade 92, with T91 as a reference, together with austenitic stainless steel (or Incoloy Alloy) 800H and its grain-boundary-engineered version 800H-TMP (ThermoMechanical Processing), is investigated in this project. A total of fifteen Grade 92 samples from two or three heats, four T91 samples from two heats, and six 800H and six 800H-TMP samples from one heat were selected, which were primarily irradiated in the Advanced Test Reactor of Idaho National Laboratory (INL), with the rest in the High Flux Isotope Reactor of Oak Ridge National Laboratory (ORNL), BOR-60 of Russia, and Phénix reactor of France. The samples were irradiated in the temperature range of 241 to 720°C and a dose range of 1.28 to ~70 displacements per atom. All the INL samples, most of the ORNL samples, and part of the LANL (Los Alamos National Laboratory) samples from the ATR, BOR-60 and Phénix reactors have been received at the Irradiated Materials Examination and Testing (IMET) hot cell facility and Low Activation Materials Design and Analysis (LAMDA) laboratory of ORNL. Post-irradiation examination of the received samples is in progress at ORNL. The effects of irradiation temperature, dose, reactor (e.g., dose rate, neutron-spectrum-induced difference in transmutation), TMP, and heats variation on the microstructures and mechanical properties of the samples will be evaluated.

36 MATERIALS SCIENCE↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37-19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37- 19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Dimensional Spectral Sampling

A wide variety of applications in science and engineering depend on effectively and efficiently exploring high- dimensional parameter spaces. Common examples are uncertainty quantification, inverse problems, or various optimization approaches. In such applications, the first step is to create an initial uniform, random sampling of the space to create a baseline of knowledge. The simulations evaluated at these samples are then used for subsequent processing. In its most generic form, the goal of sampling is to produce the maximal amount of information with the minimal number of samples. However, despite being the first step and thus influencing the performance of the entire workflow, the quality of the initial sample designs is rarely analyzed or optimized. This project develops a new spectral sampling theory for analyzing and creating experiment designs in high-dimensional spaces. Further, new algorithms for estimating sample properties and sample synthesis are designed. Finally, applications of the proposed spectral sampling tools in surrogate modeling, scientific machine learning and image analysis are presented.

97 MATHEMATICS AND COMPUTING↗

Solvent Hold Tank Sample Results for MCU-19-2-3-4 (January 2019), MCU-19-83-84-85 (February 2019), MCU-19-208-209-210 (March 2019) and MCU-19-138-139-140 (March special trim): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples (MCU-19-2-3-4, MCU-19-83-84-85, MCU-19-208-209-210); and a set from a special trim (MCU-19-138-139-140) are reported. Most of the conclusions are based on the March SHT sample (MCU-18-208-209-210). Analyses of the March SHT sample (MCU-19-208-209-210) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L, respectively) by 3% and 6%, respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has increased since the January 2019 measurement to 1141 mg/L, which is above the minimum recommended concentration (479 mg/L). These new concentrations are consistent with the concentrations observed when MCU was fully operational in 2016. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the January sample and consistently detected in the February and March samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the March SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.55E5 dpm/mL) measured in the March 2019 SHT samples was consistent with previous values observed when MCU was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias (a statistical difference at 5% level) between the FT-HNMR and HPLC methods when measuring the MaxCalix and Modifier concentration; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was also detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-19-366- 367-368 (April 2019), MCU-19-469-470-471 (May 2019), MCU-19-524-525-526 (June 2019): Quarterly Report

A trend summary of three sets of Solvent Hold Tank (SHT) monthly samples MCU-19-366-367-368 (April), MCU-19-469-470-471 (May), and MCU-19-524-525-526 (June) are reported. Most of the conclusions are based on the June SHT sample (MCU-19-524-525-526). Analyses of the June SHT sample (MCU-19-524- 525-526) indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 4% and 2% respectively but consistent with previously observed levels during normal runs. The Suppressor (N,N’,N”– tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the March 2019 measurement to 793 mg/L, which is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected presence of phthalates at a few ppm. The impurity concentration was highest in the April sample and consistently detected in the May and June samples (but always registered as a few ppm or less). Another impurity observed in the samples was mercury. Based on the June SHT sample, up to 25 ± 5 micrograms of mercury per mL of solvent was detected (as the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10. The gamma concentration (~2.90E4 dpm/mL) measured in the June 2019 SHT samples was consistent with previous values observed when the Modular Caustic-Side Solvent Extraction Unit (MCU) was operating continuously (for example, between December 2016 and January 2017). Statistical analysis of the different analytical methods detected a bias between the FT-HNMR and the High Performance Liquid Chromatography (HPLC) methods when measuring the MaxCalix and Modifier concentrations; the FT-HNMR gave a higher concentration possibly due to peak overlapping in the measured data. A bias was detected when measuring total mercury by the DMA method versus the XRF method with the XRF method reported higher mercury concentrations. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-19-569-571 (December 2019), MCU-20-1-28 (January 2020), and MCU-20-29-30-31 (June 2020) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples MCU-19-569-570-571 (December 2019), MCU-20-1-28 (January 2020), and MCU-20-29-30-31 (June 2020) are reported. Most of the conclusions are based on the June 2020 SHT sample (MCU-20-29-30-31). Analyses of the June 2020 SHT sample indicated that the Modifier (Cs-7SB) and the Extractant (MaxCalix) concentrations were above their nominal recommended concentrations (169,000 mg/L and 46,900 mg/L respectively) by 6% and 7% respectively. The Suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has remained at 833 ± 16 mg/L, but it is above the minimum recommended concentration (479 mg/L). The Semi-Volatile Organic Analysis (SVOA) and FT-HNMR did not detect any organic impurities. Another impurity observed in the samples was mercury. Based on the June 2020 SHT sample, up to 23 ± 5 micrograms of mercury per gram of solvent (or 19 ± 4 mg/L) was detected. The mercury concentration steadily decreased from 34.8 ug/g solvent (or 21.9 mg/L) in the December 2019 SHT sample to 34.8 ug/g solvent (or 19 mg/L) in the June 2020 SHT sample. The gamma concentration (~3.33E4 dpm/mL) measured in the June 2020 SHT samples was consistent with previous values observed when MCU was idle (for example, between February 2017 and August 2017). If additional SHT samples become available, the laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reference document for LANL stack sampling and ANSI N13.1 (Article) Gielow RL and McNamee MR 1993. Numerical Flue Gas Flow Modeling for Continuous Emissions Monitoring Applications. EPRI CEM Users Group Meeting. Baltimore. RP1961-13

American National Standard N13.1 “sets forth guidelines and performance criteria for sampling the emissions of airborne radioactive substances in the air discharge ducts and stacks of nuclear facilities. Emphasis is on extractive sampling from a location in a stack or duct where the contaminant is well mixed. At such a location, sampling may be conducted at a single point. This standard provides performance-based criteria for the use of air sampling probes, transport lines, sample collectors, sample monitoring instruments, and gas flow measuring methods. This standard also covers sampling program objectives, quality assurance issues, developing air sampling action levels, system optimization, and system performance verification. Workplace, containment, and environmental air monitoring are not addressed. Specific sample analysis methods and the reporting or interpreting of results are also not addressed.” (HPS 2011).

61 RADIATION PROTECTION AND DOSIMETRY↗