Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scanning Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Self-correcting electronically scanned pressure sensor

A multiple channel high data rate pressure sensing device is disclosed for use in wind tunnels, spacecraft, airborne, process control, automotive, etc., pressure measurements. Data rates in excess of 100,000 measurements per second are offered with inaccuracies from temperature shifts less than 0.25% (nominal) of full scale over a temperature span of 55 C. The device consists of thirty-two solid state sensors, signal multiplexing electronics to electronically address each sensor, and digital electronic circuitry to automatically correct the inherent thermal shift errors of the pressure sensors and their associated electronics.

Gross, C.↗

Nanoscale control over single vortex motion in an unconventional superconductor

Precise control of superconducting vortices is crucial for studying vortex dynamics and vortex braiding. We propose a new method to pull vortex lines in the layered superconductor FeSe using a scanning tunneling microscope (STM) tip. Weak contact of the STM tip with the FeSe surface locally reduces the superconducting gap, thereby creating a tunable vortex pinning potential on the nanometer scale. This enables controlled vortex line deformation even in dense vortex lattices. Analytical modeling reveals that the deformation strength scales logarithmically with conductance and depends on tip geometry. Our findings point to local strain-induced gap suppression as the mechanism for STM-mediated vortex manipulation, providing a fundamental insight relevant to vortex behavior in the context of quantum information studies.

Song, Sang Yong [Oak Ridge National Laboratory (OR↗

Advances in X-ray Instruments to Support Mars Sample Return

The Mars 2020 Perseverance rover is currently collecting drill cores of ancient igneous and sedimentary rock in and around Jezero crater for potential transport to Earth. These samples from the martian surface will enable detailed mineralogical, geochemical, and petrological measurements to characterize ancient depositional and diagenetic environments, quantitatively age-date the samples, and identify the building blocks for life or evidence for life itself. Furthermore, these drill cores are especially precious because they may represent the most pristine samples from the martian surface and our best chance at identifying martian life, as future sample return missions may be conducted by humans that can introduce biological contaminants to the samples. Because of the importance of these samples, we must take great care in their handling, curation, and preliminary analyses so that they are preserved for scientific measurements for decades to come. In-situ measurements by Perseverance have identified minerals that further warrant special treatment of the returned samples. Hydrated sulfate carbonate, swelling clay minerals, and oxychlorine salts are extremely sensitive to changes in temperature and relative humidity. The structures of hydrated sulfates and oxychlorine minerals, in particular, readily change when exposed to different conditions, meaning the mineral assemblage of the as-returned samples may be lost if the samples aren’t handled properly. Characterizing the as-returned mineral assemblage, particularly of the salts, is essential for reconstructing past aqueous conditions and habitability. To characterize the as-returned mineral assemblage, the samples must be analyzed rapidly before phase changes occur and/or under controlled conditions (e.g., within a glove box). Significant recent advances in X-ray instrumentation for robotic exploration of the solar system have resulted in high-resolution miniaturized instruments that would provide mineralogical, geochemical, and petrological information on the returned martian samples without degradation of the mineral assemblage. Here, we describe a combined X-ray diffractometer/X-ray fluorescence spectrometer (XRD/XRF), an X-ray computed tomographic (XCT) instrument, and a scanned beam XRF mapping instrument that could be used in a glove box so that the martian samples remain under controlled conditions.

E. B. Rampe↗

Streptomycin ototoxicity and hair cell regeneration in the adult pigeon utricle

OBJECTIVE: The purpose of this study was to develop a technique to investigate the regeneration of utricular hair cells in the adult pigeon (Columba livia) following complete hair cell loss through administration of streptomycin. STUDY DESIGN: Experimental animal study. METHODS: Animals were divided into four groups. Group 1 received 10 to 15 days of systemic streptomycin injections. Animals in Groups 2 and 3 received a single direct placement of a 1-, 2-, 4-, or 8-mg streptomycin dose into the perilymphatic space. Animals in Groups 1 and 2 were analyzed within 1 week from injection to investigate hair cell destruction, whereas Group 3 was investigated at later dates to study hair cell recovery. Group 4 animals received a control injection of saline into the perilymphatic space. Damage and recovery were quantified by counting hair cells in isolated utricles using scanning electron microscopy. RESULTS: Although systemic injections failed to reliably achieve complete utricular hair cell destruction, a single direct placement of a 2-, 4-, or 8-mg streptomycin dose caused complete destruction within the first week. Incomplete hair cell loss was observed with the 1-mg dose. Over the long term, regeneration of the hair cells was seen with the 2-mg dose but not the 8-mg dose. Control injections of saline into the perilymphatic space caused no measurable hair cell loss. CONCLUSIONS: Direct placement of streptomycin into the perilymph is an effective, reliable method for complete destruction of utricular hair cells while preserving the regenerative potential of the neuroepithelium.

Non-NASA Center↗

Overexpression and surface localization of HPRT in prostate cancer provides a potential target for cancer specific antibody mediated cellular cytotoxicity

Highlights: • HPRT is heterogeneously expressed in prostate cancer cells, with surface HPRT being expressed in a p53-dependent fashion. • HPRT is localized to the surface of DU145 prostate cancer cells and is targeted specifically to induce anti-tumor efficacy. • Reductions in p53 expression correspond to reductions in HPRT internal and surface expression within mutant p53 cell lines. We chose to evaluate Hypoxanthine Guanine Phosphoribosyltransferase (HPRT) as a possible biomarker for prostate cancer due to its involvement in nucleotide synthesis and cell cycle progression. We utilized two prostate cancer cell lines (PC3 and DU145) along with patient tissue and knockdowns to evaluate overall HPRT expression. The surface localization of HPRT was determined utilizing flow cytometry, confocal microscopy, and scanning electron microscopy followed by ADCC to evaluate targeting potential. We found significant upregulation of HPRT within malignant samples with approximately 47% of patients had elevated levels of HPRT compared to normal controls. We also observed a significant association between HPRT and the plasma membrane of DU145 cells (p = 0.0004), but found no presence on PC3 cells (p = 0.14). This was confirmed with scanning electron microscopy and confocal microscopy. ADCC experiments were performed to determine whether HPRT could be used as a target antigen for selective cell-mediated killing. We found that DU145 cells treated with HPRT antibodies had a significantly higher incidence of cell death than both isotype treated samples and PC3 cells treated with the same concentrations of HPRT antibody. Finally, we determined that p53 had a significant impact on HPRT expression both internally and on the surface of cancer cells. These results suggest HPRT as a possible biomarker target for the treatment of patients with prostate cancer.

60 APPLIED LIFE SCIENCES↗

Reversible assembly of silica nanoparticles at water–hydrocarbon interfaces controlled by SDS surfactant

Achieving reversible and tunable assembly of silica nanoparticles at liquid–liquid interfaces is vital for a wide range of scientific and technological applications including sustainable subsurface energy applications, catalysis, drug delivery and material synthesis. In this study, we report the mechanisms controlling the assembly of silica nanoparticles (dia. 50 nm and 100 nm) at water–heptane and water–toluene interfaces using sodium dodecyl sulfate (SDS) surfactant with concentrations ranging from 0.001–0.1 wt% using operando ultrasmall/small-angle X-ray scattering, cryogenic scanning electron microscopy imaging and classical molecular dynamics simulations. The results show that the assembly of silica nanoparticles at water–hydrocarbon interfaces can be tuned by controlling the concentrations of SDS. Silica nanoparticles are found to: (a) dominate the interfaces in the absence of interfacial SDS molecules, (b) coexist with SDS at the interfaces at low surfactant concentration of 0.001 wt% and (c) migrate toward the aqueous phase at a high SDS concentration of 0.1 wt%. Energetic analyses suggest that the van der Waals and electrostatic interactions between silica nanoparticles and SDS surfactants increase with SDS concentration. However, the favorable van der Waals and electrostatic interactions between the silica nanoparticles and toluene or heptane decrease with increasing SDS concentration. As a result, the silica nanoparticles migrate away from the water–hydrocarbon interface and towards bulk water at higher SDS concentrations. These calibrated investigations reveal the mechanistic basis for tuning silica nanoparticle assembly at complex interfaces.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Temperature control analysis and flight results for the Viking Orbiter 1975 Mars atmospheric water detection instrument

The Mars atmospheric water detector (MAWD) instrument required a temperature of -70 C at the detector. The monochromator housing required +20 C + or - 1 C. This instrument was located on the scan platform, and slewed across two solar panels. The thermal design for the detector was an open flat plate radiator thermally isolated on four 1-in. tubes, with a flexible strap to the detector. MAWD radiator view factors and heat loads from the spacecraft were determined for the Lander on and off, for all angular positions of the scan platform. Subsystem and system tests were performed using the 25-ft diameter solar simulator. In-flight results have shown no anomalies, and no degradation has been observed. Servo-controlled heaters are used to control the temperature.

Kavanagh, H. M.↗

The effectiveness of incorporating a real-time oculometer system in a commercial flight training program

The effectiveness of incroporating a real-time oculometer system into a Boeing 737 commercial flight training program was studied. The study combined a specialized oculometer system with sophisticated video equipment that would allow instructor pilots (IPs) to monitor pilot and copilot trainees' instrument scan behavior in real-time, and provide each trainee with video tapes of his/her instrument scanning behavior for each training session. The IPs' performance ratings and trainees' self-ratings were compared to the performance ratings by IPs and trainees in a control group. The results indicate no difference in IP ratings or trainees' self-ratings for the control and experimental groups. The results indicated that the major beneficial role of a real-time oculometer system for pilots and copilots having a significant amount of flight experience would be for problem solving or refinement of instrument scanning behavior rather than a general instructional scheme. It is suggested that this line of research be continued with the incorporation of objective data (e.g., state of the aircraft data), measures of cost effectiveness and with trainees having less flight experience.

Jones, D. H.↗

Tailoring the rheological properties of high protein suspension by thermal-mechanical treatment

The viscoelasticity of concentrated protein suspensions associates closely with the mixing efficiency and cleaning frequency of facility during high-protein food development. This study investigated the effects of thermal-mechanical treatment on the viscoelasticity of milk protein isolate (MPI) suspensions and their underlying mechanisms to develop protein ingredient with low viscoelasticity. MPI suspensions (20%) were treated at 25, 50 and 85°C for 10-60 min under constant shear (100 s -1 ), followed by storage at 4°C. The viscosity (η) of MPI suspension treated at 50°C and 85°C was similar to 1-10% as those treated at 25 ° C. After four days of storage at 4°C, η showed the least value in 50°C-treated samples compared to those at 25 ° C and 85 ° C. The η and storage modulus (G') was decreased with prolonged treatment at 25 and 50°C, whereas opposite trend was found in 85°C treated samples. Differential scanning calorimetry found proteins in 50°C treated samples had smaller enthalpy than those in the control and 25°C treated samples. Protein surface hydrophobicity was increased slightly from 25°C to 50°C, but remarkably in 85°C treated samples. Ultra-small angle x-ray scattering showed the radius of gyration (R-g) of casein micelle was similar to 38 nm at 25°C and 50°C treated samples but increased to similar to 44 nm 85°C treated samples with reduced compactness. A new sphere-like structure with R-g of 18 nm was generated in 85°C treated samples. These findings suggested modulating temperature during thermal-mechanical treatment is essential to alter protein structures and morphology for desirable rheological properties.

59 BASIC BIOLOGICAL SCIENCES↗

The large scale polarization explorer (LSPE) for CMB measurements: performance forecast

The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the divergence-free component of the polarization field, the B-mode component, reveals the presence of gravitational waves in the early Universe. The detection of such component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. The measurement of the polarization of the Cosmic Microwave Background (CMB) radiation is one of the current frontiers in cosmology. In particular, the detection of the primordial divergence-free component of the polarization field, the B-mode, could reveal the presence of gravitational waves in the early Universe. The detection of such a component is at the moment the most promising technique to probe the inflationary theory describing the very early evolution of the Universe. We present the updated performance forecast of the Large Scale Polarization Explorer (LSPE), a program dedicated to the measurement of the CMB polarization. LSPE is composed of two instruments: LSPE-Strip, a radiometer-based telescope on the ground in Tenerife-Teide observatory, and LSPE-SWIPE (Short-Wavelength Instrument for the Polarization Explorer) a bolometer-based instrument designed to fly on a winter arctic stratospheric long-duration balloon. The program is among the few dedicated to observation of the Northern Hemisphere, while most of the international effort is focused into ground-based observation in the Southern Hemisphere. Measurements are currently scheduled in Winter 2022/23 for LSPE-SWIPE, with a flight duration up to 15 days, and in Summer 2022 with two years observations for LSPE-Strip. In this work, we describe the main features of the two instruments, identifying the most critical aspects of the design, in terms of impact on the performance forecast. We estimate the expected sensitivity of each instrument and propagate their combined observing power to the sensitivity to cosmological parameters, including the effect of scanning strategy, component separation, residual foregrounds and partial sky coverage. We also set requirements on the control of the most critical systematic effects and describe techniques to mitigate their impact. LSPE will reach a sensitivity in tensor-to-scalar ratio of σr < 0.01, set an upper limit r < 0.015 at 95% confidence level, and improve constraints on other cosmological parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Vertically Aligned Single-Crystalline CoFe 2 O 4 Nanobrush Architectures with High Magnetization and Tailored Magnetic Anisotropy

Micrometer-tall vertically aligned single-crystalline CoFe 2 O 4 nanobrush architectures with extraordinarily large aspect ratio have been achieved by the precise control of a kinetic and thermodynamic non-equilibrium pulsed laser epitaxy process. Direct observations by scanning transmission electron microscopy reveal that the nanobrush crystal is mostly defect-free by nature, and epitaxially connected to the substrate through a continuous 2D interface layer. In contrast, periodic dislocations and lattice defects such as anti-phase boundaries and twin boundaries are frequently observed in the 2D interface layer, suggesting that interface misfit strain relaxation under a non-equilibrium growth condition plays a critical role in the self-assembly of such artificial architectures. Further, magnetic property measurements have found that the nanobrushes exhibit a saturation magnetization value of 6.16 μB/f.u., which is much higher than the bulk value. The discovery not only enables insights into an effective route for fabricating unconventional high-quality nanostructures, but also demonstrates a novel magnetic architecture with potential applications in nanomagnetic devices.

36 MATERIALS SCIENCE↗

The application of color display techniques for the analysis of Nimbus infrared radiation data

A color enhancement system designed for the Applications Technology Satellite (ATS) spin scan experiment has been adapted for the analysis of Nimbus infrared radiation measurements. For a given scene recorded on magnetic tape by the Nimbus scanning radiometers, a virtually unlimited number of color images can be produced at the ATS Operations Control Center from a color selector paper tape input. Linear image interpolation has produced radiation analyses in which each brightness-color interval has a smooth boundary without any mosaic effects. An annotated latitude-longitude gridding program makes it possible to precisely locate geophysical parameters, which permits accurate interpretation of pertinent meteorological, geological, hydrological, and oceanographic features.

Allison, L. J.↗

Factors affecting laser-trim stability of thick film resistors

Various factors affecting precision of trim and resistor stability were considered. The influence of machine operating parameters on resistor performance was examined and quantified through statistically designed experiments for a Q switched YAG laser system. Laser kerf quality was studied by scanning electron microscopy and related to kerf isolation resistance measurements. A relatively simple production oriented, quality control test is proposed for rapid determination of kerf electrical stability. In addition, the effect of cut design and extent of trim on precision and stability were discussed.

Cote, R. E.↗

Planned observations of the diffuse sky radiation during shuttle mission STS-4

The planned space shuttle mission STS-4 will use the Skylab flight spare ten-color (near UV to near IR) photopolarimeter with boresighted 16 mm camera. This 164-hour mission will observe the zodiacal light to within approximately 20 deg of the sun (in and out of the ecliptic). The mission consists of several distinct phases: (1) tail-to-sun (TTS), belly to earth for 18 hours; (2) nose-to-sun, solar inertial for 79 hours; (3) bay-to-sun for 26 hours; and (4) passive thermal control for 37 hours. During the TTS phase, where most observations are scheduled, the instrument will scan back and forth in elevation at 4 deg/sec while the orbiter moves across the sky at its 4 deg/min orbital rate. The combined orbiter/instrument motion will result in a saw-tooth pattern of observations projected on the sky (between the 14 deg and 120 deg elevation limits) and will enable extensive measurements of the brightness, polarization and color of the background starlight to be made.

Weinberg, J. L.↗

Effect of Ionizing Radiation on the Mechanical and Structural Properties of Graphite Fiber Reinforced Composites

Graphite/epoxy (T300/5208) and graphite/polyimide composites (C6000/PMR 15) were exposed to various levels of 0.5 MeV electron radiation with the maximum dose being 10,000 Mrad. A three point bending test was used to evaluate the ultimate stress and modulus of the composites. In all composites except transverse samples of C6000/PMR 15 ultimate stress values remained approximately constant or increased slightly. The modulus values remained approximately constant for all composite types regardless of the radiation level. Interfacial aspects of composites were studied. Interlaminar shear tests were performed on T300/5208 and C6000/PMR 15 composites irradiated to 10,000 Mrad. There was an initial increase in interlaminar shear strength (up to 1,000 Mrad) followed by a sharp decrease with further radiation exposure. Using scanning electron microscopy no visual differences in the mode of fracture could be detected between ruptured control samples and those exposed to various levels of radiation. Electron spectroscopy for chemical analysis (ESCA) revealed little change in the surface elements present in control and highly irradiated T300/5208 composite samples.

Wolf, Kay Woodroof↗

NTF model pressure measurements

Pressure measurements on the National Transonic Facility models will be made using electronically scanned pressure instrumentation. The system consists of pressure modules, a pressure calibration standard, and a system controller. The pressure modules, which must be operated above -18 C, will be housed in model-integrated designed thermally controlled containers. The Pathfinder 1 192-channel pressure package is described. Recent and planned developments to reduce the pressure module's volume per channel ratio are discussed, including the 48-channel module and a proposed 32-channel module that would be 2.54 by 2.54 by 8.13 cm. Pressure transducers capable of operating at cryogenic temperatures for dynamic and static pressure measurements are discussed.

Kern, F. A.↗

Construction of a 2- by 2-foot transonic adaptive-wall test section at the NASA Ames Research Center

The development of a new production-size, two-dimensional, adaptive-wall test section with ventilated walls at the NASA Ames Research Center is described. The new facility incorporates rapid closed-loop operation, computer/sensor integration, and on-line interference assessment and wall corrections. Air flow through the test section is controlled by a series of plenum compartments and three-way slide vales. A fast-scan laser velocimeter was built to measure velocity boundary conditions for the interference assessment scheme. A 15.2-cm- (6.0-in.-) chord NACA 0012 airfoil model will be used in the first experiments during calibration of the facility.

Morgan, Daniel G.↗

Development of an electronically-scanned pressure module for operation at cryogenic temperatures

Pressure and temperature characteristics were measured for a number of multichannel electronically scanned pressure sensors. The tests were made on commercially available units designed to operate in a controlled temperature environment. Measurements of zero shift, sensitivity, and nonlinearity for each transducer were taken over a temperature range from 100 K to 340 K using a computer controlled data acquisition system. The units tested failed to meet accuracy specifications over the complete temperature range, which was expected. However, the sensors showed acceptable and predictable behavior over the temperature range from approximately -40 C (233 K) to 70 C (343 K). It was determined that a combination of local heating and accurate temperature monitoring can result in a device that can be compensated for temperature as well as its other physical properties. The design of a prototype for operation in a cryogenic environment is proposed, and a method for compensation is developed.

Johnson, Preston B.↗