Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Solar Energy Technologies Program Newsletter - September 2009

This quarterly newsletter is intended for participants and stakeholders in the DOE Solar Program. The content includes features on technology development, market transformation, and policy analysis for solar. Highlights include solar industry updates, DOE funding opportunity announcements and awards, and national laboratory technology developments.

solar, pv, csp, systems integration, market transf↗

Silicon solar cell process development, fabrication, and analysis

Work has progressed in fabrication and characterization of solar cells from ubiquitous crystallization process (UCP) wafers and LASS ribbons. Gettering tests applied to UCP wafers made little change on their performance compared with corresponding baseline data. Advanced processes such as shallow junction (SJ), back surface field (BSF), and multilayer antireflection (MLAR) were also applied. While BSF by Al paste had shunting problems, cells with SJ and BSF by evaporated Al, and MLAR did achieve 14.1% AMI on UCP silicon. The study of LASS material was very preliminary. Only a few cells with SJ, BSR, (no BSF) and MLAR were completed due to mechanical yield problems after lapping the material. Average efficiency was 10.7% AMI with 13.4% AMI for CZ controls. Relatively high minority carrier diffusion lengths were obtained. The lower than expected Jsc could be partially explained by low active area due to irregular sizes.

Yoo, H. I.↗

Space Station Freedom solar dynamic modules structural modelling and analysis

In support of the Space Station Freedom (SSF) Solar Dynamic Power Module effort, structural design studies were performed to investigate issues related to the design of the power module, its pointing capabilities, and the integration of the module into the SSF infrastructure. Of particular concern from a structural viewpoint are the dynamics of the power module, the impact of the power module on the Space Station dynamics and controls, and the required control effort for obtaining the specified Solar Dynamic Power Module pointing accuracy. Structural analyses were performed to determine the structural dynamics attributes of both the existing and the proposed structural dynamics module designs. The objectives of these analyses were to generate validated Solar Dynamic Power Module NASTRAN finite element models, combine Space Station and power module models into integrated system models, perform finite element modal analyses to assess the effect of the relocations of the power module center of mass, and provide modal data to controls designers for control systems design.

Lawrence, Charles↗

End-Use Savings Shapes Measure Documentation: Window Film

This documentation focuses on a single end-use savings shape measure - window film. The window film studied in this analysis, called solar control film, is a passive retrofit solution for windows that does not involve window replacement. This type of film is composed of transparent, tinted, or metalized laminated polyester layers and can be attached to an existing window surface (either on the exterior or interior side of the window). The properties of the window film are designed to shift the thermal and optical performances of the overall glazing system in order to serve various needs the customer would have (e.g., heat, glare). While the practical goal of purchasing and installing a window film varies widely in the real market, this study only focuses on the goal of energy savings, and highlighting the corresponding emissions. Other important aspects that customers typically consider include visual comfort, privacy, aesthetics, ultraviolet protection, etc. Thus, in practice, customers often choose a window film product not only to save energy (or cost) but also to mitigate issues around glare, excessive light, daytime privacy, or inconsistent appearance of the building. Window film products that were modeled in this analysis significantly reduced the solar heat gain coefficient of the overall glazing system, resulting in better energy savings for buildings in hot climate regions. However, significantly reducing the solar heat gain coefficient that can block unfavorable heat during the summer can actually harm blocking favorable heat during the winter. By applying window films on a stock of buildings covering various load and weather conditions, this analysis highlights when (e.g., time of day) and where (e.g., geospacial location) we can save energy with window films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient analysis and energy optimization of solar heating and cooling systems in various configurations

In this paper, a transient simulation model of solar-assisted heating and cooling systems (SHC) is presented. A detailed case study is also discussed, in which three different configurations are considered. In all cases, the SHC system is based on the coupling of evacuated solar collectors with a single-stage LiBr-H{sub 2}O absorption chiller, and a gas-fired boiler is also included for auxiliary heating, only during the winter season. In the first configuration, the cooling capacity of the absorption chiller and the solar collector area are designed on the basis of the maximum cooling load, and an electric chiller is used as the auxiliary cooling system. The second layout is similar to the first one, but, in this case, the absorption chiller and the solar collector area are sized in order to balance only a fraction of the maximum cooling load. Finally, in the third configuration, there is no electric chiller, and the auxiliary gas-fired boiler is also used in summer to feed the absorption chiller, in case of scarce solar irradiation. The simulation model was developed using the TRNSYS software, and included the analysis of the dynamic behaviour of the building in which the SHC systems were supposed to be installed. The building was simulated using a single-lumped capacitance model. An economic model was also developed, in order to assess the operating and capital costs of the systems under analysis. Furthermore, a mixed heuristic-deterministic optimization algorithm was implemented, in order to determine the set of the synthesis/design variables that maximize the energy efficiency of each configuration under analysis. The results of the case study were analyzed on monthly and weekly basis, paying special attention to the energy and monetary flows of the standard and optimized configurations. The results are encouraging as for the potential of energy saving. On the contrary, the SHC systems appear still far from the economic profitability: however, this is notoriously true for the great majority of renewable energy systems. (author)

14 SOLAR ENERGY↗

Multi-wavelength analysis from tomography study on solar chromosphere

The Sun as the most important star for scientific laboratory in astrophysics as well as encompassing all living aspect on Earth, still holds scientific mystery. As the established model that the Sun’s energy fueled by the nuclear reaction, along with transport process to the typical Solar surface on around 6000-K temperature, many aspects still left as an open questions, such as how the chromosphere responded to the photospheric dynamics. In this preliminary work, we try to analyze the Solar chromosphere respond to the Photospheric dynamics using tomography study implementing multi-wavelength analysis observation obtained from Dutch Open Telescope. Using the Hydrogen-alpha Doppler signal as the primary diagnostic tool, we try to investigate the inter-relation between the magnetic and gas pressure dynamics that occur in the chromosphere.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Field support for solar tracker

The objectives, preparation and analysis prior to test, test results, and closed loop analysis of the solar telescope gimbal and tracker system are discussed.

Source record↗

Solar wind latitude variations and multiple scattering from Galileo interplanetary Lyman-alpha observations

The Galileo Ultraviolet Spectrometer Experiment (UVS) obtained a map of the celestial sphere from interplanetary Lyman-alpha (IPLA) on 13, 14 December 1990 during the Earth1 encounter. The Galileo spacecraft was near the downwind interstellar axis during the encounter and the map view directions filled the downwind hemisphere. The ratio between the observation and a single scattering model is attributed to a direct measurement of the multiple scattering correction required to model IPLA in the inner solar system. Analysis of this data set, referred to as an antisun map, shows that the solar wind charge exchange rate with interplanetary gas is 25 percent less over the solar poles than in the ecliptic at solar maximum. A model of the interstellar wind based on the antisun map observation exhibits a number density of atomic hydrogen far from the solar system, inside the heliosphere, of 0.16 +/- 0.05/cu cm.

Ajello, Joseph M.↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar PV, and natural gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in US power markets. This is especially true for geothermal resources with low to medium temperatures, which results in relatively low thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods.

14 SOLAR ENERGY↗

Solar maximum mission panel jettison analysis remote manipulator system

A study is presented of the development of the Remote Manipulator System (RMS) configurations for jettison of the solar panels on the Solar Maximum Mission/Multimission Satellite. A valid RMS maneuver between jettison configurations was developed. Arm and longeron loads and effector excursions due to the solar panel jettison were determined to see if they were within acceptable limits. These loads and end effector excursions were analyzed under two RMS modes, servos active in position hold submode, and in the brakes on mode.

Bauer, R. B.↗