Search NASA⌕ Search

SEARCH · Search NASA

Results for “Target tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

TU-AB-202-07: A Novel Method for Registration of Mid-Treatment PET/CT Images Under Conditions of Tumor Regression for Patients with Locally Advanced Lung Cancers

Purpose: In PET-guided adaptive radiotherapy (RT), changes in the metabolic activity at individual voxels cannot be derived until the duringtreatment CT images are appropriately registered to pre-treatment CT images. However, deformable image registration (DIR) usually does not preserve tumor volume. This may induce errors when comparing to the target. The aim of this study was to develop a DIR-integrated mechanical modeling technique to track radiation-induced metabolic changes on PET images. Methods: Three patients with non-small cell lung cancer (NSCLC) were treated with adaptive radiotherapy under RTOG 1106. Two PET/CT image sets were acquired 2 weeks before RT and 18 fractions after the start of treatment. DIR was performed to register the during-RT CT to the pre-RT CT using a B-spline algorithm and the resultant displacements in the region of tumor were remodeled using a hybrid finite element method (FEM). Gross tumor volume (GTV) was delineated on the during-RT PET/CT image sets and deformed using the 3D deformation vector fields generated by the CT-based registrations. Metabolic tumor volume (MTV) was calculated using the pre- and during–RT image set. The quality of the PET mapping was evaluated based on the constancy of the mapped MTV and landmark comparison. Results: The B-spline-based registrations changed MTVs by 7.3%, 4.6% and −5.9% for the 3 patients and the correspondent changes for the hybrid FEM method −2.9%, 1% and 6.3%, respectively. Landmark comparisons were used to evaluate the Rigid, B-Spline, and hybrid FEM registrations with the mean errors of 10.1 ± 1.6 mm, 4.4 ± 0.4 mm, and 3.6 ± 0.4 mm for three patients. The hybrid FEM method outperforms the B-Spline-only registration for patients with tumor regression Conclusion: The hybrid FEM modeling technique improves the B-Spline registrations in tumor regions. This technique may help compare metabolic activities between two PET/CT images with regressing tumors. The author gratefully acknowledges the financial support from the National Institutes of Health Grant.

60 APPLIED LIFE SCIENCES↗

Understanding the Evolution of Customer Motivations and Adoption Barriers in Residential Solar Markets: Survey Data

This research focused on accelerating solar photovoltaic (PV) diffusion by collecting new market data and developing predictive modeling frameworks to test and refine understandings of household level motivations for adopting solar. Three different household-level surveys were fielded: one for households who had installed PV on their current home or had signed a contract to do so (the Adopter survey), one for households that had seriously considered PV but had not installed it (the Considerer survey), and one for the general population who did not have PV on their current home (the general population survey or GPS). Survey respondents were from four U.S. states: New Jersey, New York, Arizona, and California. Details of recruiting and sampling are documented below. Research projects on residential PV adoption often collect data only from PV adopters or from the general population. One of the innovations of this project was the three-pronged household survey data collection. By collecting similar data from three fairly different "statuses" with respect to adoption, the surveys provide a basis for understanding how those who do not have rooftop PV differ from those who have, for how and why people do (or don't) transition from not having to having rooftop PV on their home, and for understanding the characteristics and viewpoints of households who have scarcely, or not at all, entered the "PV consideration" track. All three surveys covered single-family owner-occupied households in each of the four target states used in the project -- Arizona, California, New Jersey, and New York - allowing a comparative approach to understanding how the factors that affect PV adoption vary by geography and policy conditions. The General Population and Considerer surveys provide a basis for understanding opinions about and interest in solar, and how these relate to household demographics and other conditions. Paired with the Adopter survey, they also provide data for understanding how those who do not have rooftop PV differ from those who have, and for how and why people do (or don't) transition from not having to having rooftop PV on their home. The Adopter survey questions were designed to capture a broad range of information on what motivates and impedes households to install rooftop PV, as well as the details and timing of the decision and installation. Survey instrument development drew from existing PV adoption survey instruments, PV adoption literature, and research team experience, as well as from past work on household interest in energy efficiency, environmental attitudes, purchasing tendencies, and related knowledge. Early interviews and discussions with installers and others in the PV industry were also taken into consideration.

14 SOLAR ENERGY↗

Projected Growth in Small-Scale, Fossil-Fueled Distributed Generation: Potential Implications for the U.S. Greenhouse Gas Inventory

The generation capacity of small-scale (less than one megawatt) fossil-fueled electricity in the United States is anticipated to grow by threefold to twenty-fold from 2015 to 2040. However, in adherence with internationally agreed upon carbon accounting methods, the Environmental Protection Agency's (EPA's) U.S. Greenhouse Inventory (GHGI) does not currently attribute greenhouse gases (GHGs) from these small-scale distributed generation sources to the electric power sector and instead accounts for these emissions in the sector that uses the distributed generation (e.g., the commercial sector). In addition, no other federal electric-sector GHG emission data product produced by the EPA or the U.S. Energy Information Administration (EIA) can attribute these emissions to electricity. We reviewed the technical documentation for eight federal electric-sector GHG emission data products, interviewed the data product owners, collected their GHG emission estimates, and analyzed projections for growth in fossil-fueled distributed generation. We show that, by 2040, these small-scale generators could account for at least about 1%- 5% of total CO2 emissions from the U.S. electric power sector. If these emissions fall outside the electric power sector, the United States may not be able to completely and accurately track changes in electricity-related CO2 emissions, which could impact how the country sets GHG reduction targets and allocates mitigation resources. Because small-scale, fossil-fueled distributed generation is expected to grow in other countries as well, the results of this work also have implications for global carbon accounting.

54 ENVIRONMENTAL SCIENCES↗

Stability of Cool Cores during Galaxy Cluster Growth: A Joint Chandra/SPT Analysis of 67 Galaxy Clusters along a Common Evolutionary Track Spanning 9 Gyr

We present the results of a joint analysis of Chandra X-ray and South Pole Telescope (SPT) Sunyaev–Zel’dovich (SZ) observations targeting the first sample of galaxy clusters at 0.3 < z < 1.3, selected to be the progenitors of well-studied nearby clusters based on their expected accretion rate. We develop a new procedure in order to tackle the analysis challenge that is estimating the intracluster medium (ICM) properties of low-mass and high-redshift clusters with ~150 X-ray counts. One of the dominant sources of uncertainty on the ICM density profile estimated with a standard X-ray analysis with such shallow X-ray data is due to the systematic uncertainty associated with the ICM temperature obtained through the analysis of the background-dominated X-ray spectrum. We show that we can decrease the uncertainty on the density profile by a factor varying between 2 and 8 with a joint deprojection of the X-ray surface brightness profile measured by Chandra and the SZ-integrated Compton parameter available in the SPT cluster catalog. We apply this technique to the whole sample of 67 clusters in order to track the evolution of the ICM core density during cluster growth. We confirm that the evolution of the gas density profile is well modeled by the combination of a fixed core and a self-similarly evolving non-cool-core profile. We show that the fraction of cool cores in this sample is remarkably stable with redshift although clusters have gained a factor of ~4 in total mass over the past ~9 Gyr.

79 ASTRONOMY AND ASTROPHYSICS↗

3D model generation using an airborne swarm

Using an artificial kinematic field to provide co-ordination between multiple inspection UAVs, the authors herein demonstrate full 3D modelling capability based on a photogrammetric system. The operation of the system is demonstrated by generating a full 3D surface model of an intermediate level nuclear waste storage drum. Such drums require periodic inspection to ensure that drum distortion or corrosion is carefully monitored. Performing this inspection with multiple airborne platforms enables rapid inspection of structures that are inaccessible to on-surface remote vehicles and are in human-hazardous environments. A three-dimensional surface-meshed model of the target can then be constructed in post-processing through photogrammetry analysis of the visual inspection data. The inspection environment uses a tracking system to precisely monitor the position of each aerial vehicle within the enclosure. The vehicles used are commercially available Parrot AR. Drone quadcopters, controlled through a computer interface connected over an IEEE 802.11n (WiFi) network, implementing a distributed controller for each vehicle. This enables the autonomous and distributed elements of the control scheme to be retained, while alleviating the vehicles of the control algorithm’s computational load. The control scheme relies on a kinematic field defined with the target at its centre. This field defines the trajectory for all the drones in the volume relative to the central target, enabling the drones to circle the target at a set radius while avoiding drone collisions. This function enables complete coverage along the height of the object, which is assured by transitioning to another inspection band only after completing circumferential coverage. Using a swarm of vehicles, the time until complete coverage can be significantly reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Priming antibody responses to the fusion peptide in rhesus macaques

Immunodominance of antibodies targeting non-neutralizing epitopes and the high level of somatic hypermutation within germinal centers (GCs) required for most HIV broadly neutralizing antibodies (bnAbs) are major impediments to the development of an effective HIV vaccine. Rational protein vaccine design and non-conventional immunization strategies are potential avenues to overcome these hurdles. Here, we report using implantable osmotic pumps to continuously deliver a series of epitope-targeted immunogens to rhesus macaques over the course of six months to prime and elicit antibody responses against the conserved fusion peptide (FP). GC responses and antibody specificities were tracked longitudinally using lymph node fine-needle aspirates and electron microscopy polyclonal epitope mapping (EMPEM), respectively, to show antibody responses to the FP/N611 glycan hole region were primed, although exhibited limited neutralization breadth. Application of cryoEMPEM delineated key residues for on-target and off-target responses that can drive the next round of structure-based vaccine design.

60 APPLIED LIFE SCIENCES↗

Microtron MT 25 as a source of neutrons

The objective was to describe Microtron MT25 as a source of neutrons generated by bremsstrahlung induced photonuclear reactions in U and Pb targets. Bremsstrahlung photons were produced by electrons accelerated at energy 21.6 MeV. Spectral fluence of the generated neutrons was calculated with MCNPX code and then experimentally determined at two positions by means of a Bonner spheres spectrometer in which the detector of thermal neutrons was replaced by activation Mn tablets or track detectors CR-39 with a {sup 10}B radiator. The measured neutron spectral fluence and the calculated anisotropy served for the estimation of neutron yield from the targets and for the determination of ambient dose equivalent rate at the place of measurement. Microtron MT25 is intended as one of the sources for testing neutron sensitive devices which will be sent into the space.

43 PARTICLE ACCELERATORS↗

The NIFFTE Project

The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) is a double-sided Time Projection Chamber (TPC) with micromegas readout designed to measure the energy-dependent neutron-induced fission cross sections of the major and minor actinides with unprecedented accuracy. The NIFFTE project addresses the challenge of minimizing major sources of systematic uncertainties from previous fission chamber measurements such as: target and beam non-uniformities, misidentification of alpha and light charged particles as fission fragments, and uncertainties inherent to the reference standards used. In-beam tests of the NIFFTE TPC at the Los Alamos Neutron Science Center (LANSCE) started in 2010 and have continued in 2011, 2012 and 2013. An overview of the NIFFTE TPC status and performance at LANSCE will be presented.

gaseous detectors↗

TH-CD-207A-04: Optimized Respiratory Gating for Abnormal Breathers in Pancreatic SBRT

Purpose: Pancreatic SBRT is uniquely challenging due to both the erratic/unstable motion of the pancreas and the close proximity of the radiosensitive small bowel. Respiratory gating can mitigate this effect, but the irregularity of motion severely affects traditional phase-based gating. The purpose of this study was to analyze real-time motion data of pancreatic tumors to optimize the efficacy and accuracy of respiratory gating, with the overall goal of enabling dose escalated pancreatic SBRT. Methods: Fifteen pancreatic SBRT patients received 30–33 Gy in 5 fractions on a Varian TrueBeam STx unit. Abdominal compression was used to reduce the amplitude of tumor motion, and daily cone-beam computed tomography (CBCT) scans were acquired prior to each treatment for target localization purposes. For this study, breathing data (phase and amplitude) were collected during each CBCT scan using Varian’s Real-Time Position Management system. An in-house template matching technique was used to track the superior-inferior motion of implanted fiducial markers in CBCT projection images. Using tumor motion and breathing data, phase-based or amplitude-based respiratory gating was simulated for all 75 fractions, targeting either end-exhalation or end-inhalation phases of breathing. Results: For the average patient, gating at end-exhalation offered the best reductions in effective motion for equal duty cycles. However, optimal central phase angle varied widely (range: 0–92%, mean±SD: 49±12%), and phase-based gating windows typically associated with end-exhalation (i.e., “30–70%”) were rarely ideal. Amplitude-based gating significantly outperformed phase-based gating, with average effective ranges for amplitude-based gating 25% lower than phase-based gating ranges (as much as 73% lower). Amplitude-based gating was consistently better suited to accommodate abnormal breathing patterns. For both phase-based and amplitude-based gating, end-exhalation provided significantly better results than end-inhalation. Conclusion: Amplitude-based gating reliably outperformed phase-based gating, and end-exhalation was more suitable than end-inhalation. These results will be used to guide future dose-escalation trials. Research funding provided by Varian Medical Systems to Miften and Jones.

60 APPLIED LIFE SCIENCES↗

In situ monitoring of the stopped muon flux at Mu2e

The specific object of Mu2e search is the neutrino-less coherent $\mu^-\rightarrow e^-$ conversion in the field of an aluminum nucleus and the signal is a monoenergetic electron of energy $ \approx 104.97$ MeV. This process is forbidden in the Standard Model but allowed in many of its extensions: with minimal changes to include neutrino masses and oscillation, the Branching Ratio of this process, or the similarly interesting $\mu\rightarrow e \gamma$ decay, is expected to be of the order of $\mathcal{O}(10^{-54})$. Values like these are below any currently achievable experimental sensitivity, and the observation of a signal would be unambiguous evidence of New Physics. The upper limit on the muon conversion was set by SINDRUM II at $7\times10^{-13}$ (90\% C.L.) and the goal of the Mu2e collaboration is an improvement of 4 order of magnitudes.\\ The Mu2e experiment can be conceptually divided into three stages: interaction of the primary proton pulse with the tungsten target a nd production of $\pi$ and $\mu$; collection and transport of the produced particles down to the aluminum stopping target; interaction with the stopping target and measurement of the output particles. The measurement of the stopped muon flux is of cardinal importance for the normalization of the Mu2e results. The baseline design includes two detectors developed to measure this flux, counting $\gamma$ emitted by the muonic atoms: HPGe and LaBr$_3$(Ce). The studies performed by the Mu2e Collaboration show that these two systems can be reliably used to determine the overall normalization.\\ The number of stopped muons is proportional to the number of protons on target, which itself depends on the extraction system for the proton beam. The Mu2e beam delivery system will use a resonant extraction to create the proton pulses and this method is characterized by intensity fluctuations on the time scale of milliseconds. These fluctuations, aside from the proportional fluctuation of t he number of muons, have a non-trivial impact on the overall! performance of the apparatus. For example, higher intensity proton bunches translate into higher veto rates by the Cosmic Rays Veto system, which is triggered by secondary particles generated by the proton interaction. Another example is the effect of the instantaneous luminosity on the reconstruction efficiency: higher intensity translates into higher detector occupancy, which in turn reduces the reconstruction efficiency.\\ The two cited detectors encounter limitations when trying to monitor the flux at the millisecond timescales: HPGe is by construction a slow detector while the rate of emission of the $\gamma (1809\textrm{ keV})$ the LaBr$_3$(Ce) will measure is too low. As of today, no system allows to monitor these fluctuations and the goal of this Thesis is to try filling this gap. The method we developed to monitor the fluctuations of the stopped muon flux, and by extension, the fluctuation in the proton pulses intensity is based on counting the number of muons capt ured in the stopping target by counting the number of protons produced in the process of the nuclear muon capture. This is one of the possible processes a stopped muon can undergo and it can lead to the ejection of charged particles.\\ The reconstruction algorithms were developed by the Mu2e collaboration with the explicit (and sometimes implicit) aim to reconstruct tracks of electrons in an energy range of a conversion electron. The protons we are interested in behave quite differently from these electrons and the cardinal task of this study has been to tailor the reconstruction routines to these particles. This has been done by analyzing simulated events consisting of a single proton to optimize the procedure and understand the features of these tracks. A major difference with respect to the electrons is the non-relativistic nature of $100\div300$ MeV$/c$ protons: accounting for the low velocity is both a challenge and a unique signature of the tracks.\\ The use of a pulse d beam and the need to allow produced $\pi$ to decay and $\m! u$ to int! eract in the stopping target forces the definition of a Mu2e \textit{event}: an event is comprised by everything which happens in a $1.7\ \mu$s window between the incidence two consecutive proton pulses. This means that the reconstruction will be performed in an environment crowded by many different particles. The next step of this study has been to estimate the performance of the method in a fully-fledged Mu2e simulated event and to study what kind of selections would improve it.\\ Our results are satisfactory since the number of reconstructed protons is significant (few per event), and show that a monitor on the timescale of milliseconds is indeed possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing a commercial building energy data framework for India

Buildings account for over 40% of the world’s energy consumption and are therefore a key contributor to a country’s energy as well as carbon budget. Understanding how buildings use energy is critical to understanding how related policies may impact energy use. Data enables decision making, and good quality data arms consumers with the tools to compare their energy performance to their peers, allowing them to differentiate their buildings in the real estate market on the basis of their energy footprint. Good quality data are also essential for policy makers to prioritize their energy saving strategies and track implementation. The United States’ Commercial Building Energy Consumption Survey (CBECS) is an example of a successful data framework that is highly useful for governmental and nongovernmental initiatives related to benchmarking energy forecasting, rating systems and metrics, and more. The Bureau of Energy Efficiency (BEE) in India developed the Energy Conservation Building Code (ECBC) and launched the Star Labeling program for a few energy-intensive building segments as a significant first step. However, a data driven policy framework for systematically targeting energy efficiency in both new construction and existing buildings has largely been missing. There is no quantifiable mechanism currently in place to track the impact of code adoption through regular reporting/survey of energy consumption in the commercial building stock. In this paper we present findings from our study that explored use cases and approaches for establishing a commercial buildings data framework for India.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Filling the gap: hunting for vector bosons at the MUonE experiment with displaced decay signature

The upcoming MUonE experiment aims to precisely measure the running of the fine structure constant via elastic muon-electron scattering, to shed light on the current tension in the muon’s anomalous magnetic moment. In addition to its primary function as a precision experiment, MUonE also offers a unique testing ground to probe long-lived vector bosons. Such vector bosons can be produced via μe → μeV or μN → μNV scattering and decay into an electron/positron pair a few centimeters away from the interaction point. With its high-resolution tracking system and unique geometric design, MUonE is well-suited to reconstruct displaced vertices close to the target, allowing it to probe parameter space previously unattainable at colliders and longer-baseline beam dump experiments. We present a comprehensive study of the discovery potential of BSM vector boson mediators at the MUonE experiment. We show that MUonE can fill the long-standing gap in the parameter space of vector boson mediators with masses up to around 100 MeV.

Models for Dark Matter↗

Absolute Hugoniot measurements in low-density plastic foams on the NIKE shock compression platform

The propagation of Mbar-range shock waves in low-density foam materials is of interest to target design in all approaches to inertial confinement fusion, high energy density physics, and laboratory astrophysics. We report absolute Hugoniot measurements for CH 1.72 N 0.086 O 0.37 plastic foams with 73 and 94 mg/cm 3 densities in the 32–107 km/s shock velocity range. The experiments were performed on the shock compression platform developed on the NIKE KrF laser facility at the U.S. Naval Research Laboratory. NIKE's 4 or 8-ns long flat-top laser pulses drive steady shock waves into foam targets at the ablative pressures of 1–7 Mbar. The propagation of the ablation and shock fronts is tracked continuously in time using streaked side-on monochromatic x-ray imaging radiography. The straight x−t trajectories of the shock and ablation fronts in the recorded streak images confirmed their steadiness. The SESAME tabulated equation of state predictions generally agrees with our Hugoniot data within a 95% confidence band. The experimental uncertainty of the evaluated shock density compression ratios remains large, indicating the need for more experiments and improved theoretical understanding of the strong shock propagation mechanisms in dry foams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mapping the cosmic gamma-ray horizon: the 1CGH catalogue of Fermi -LAT detections above 10 GeV

ABSTRACT We present the First Cosmic Gamma-ray Horizon (1CGH) catalogue, featuring $\gamma$-ray detections above 10 GeV based on 16 yr of observations with the Fermi Large Area Telescope (Fermi-LAT) satellite. After carefully selecting a sample of blazars and blazar candidates from catalogues in the literature, we performed a binned likelihood analysis and identified 2791 $\gamma$-ray emitters above 10 GeV, at >3$\sigma$ level, including 62 that are new $\gamma$-ray detections. For each source, we estimated the mean energy of the highest energy bin and analysed them in the context of the cosmic gamma-ray horizon. By adopting a reference model for the extragalactic background light (EBL), we identified a subsample of 525 sources where moderate to severe $\gamma$-ray absorption could be detected across the redshift range of 0–3. This work provides the most up-to-date compilation of detections above 10 GeV, along with their redshift information. We condense extensive results from the literature, including reports on observational campaigns dedicated to blazars and $\gamma$-ray sources, thereby delivering an unprecedented review of the redshift information for sources detected above 10 GeV. Additionally, we highlight key 1CGH sources where redshift information remains incomplete, offering guidance for future optical observation campaigns. The 1CGH catalogue aims to track the most significant sources for studying the $\gamma$-ray transparency of the Universe. Furthermore, it provides a targeted subsample where the EBL optical depth, $\tau _{(E,z)}$, can be robustly measured using Fermi-LAT data.

Arsioli, Bruno (ORCID:0000000181666602)↗

Biological Consequences and Health Risks Of Low-Level Exposure to Ionizing Radiation: Commentary on the Workshop

This paper provides an integration and discussion of the information presented at the workshop held from May 2 to 5, 2010, in Richland, WA, adjacent to the Pacific Northwest National Laboratory (PNNL). Consequently, this is commentary and not necessarily a consensus document. This workshop was in honor of Dr. Victor P. Bond in celebration of his numerous contributions to the radiation sciences. Internationally recognized experts in biophysics, experimental radiation biology, epidemiology, and risk assessment were invited to discuss all issues of low-dose risk. This included the physics of track structure and its consequences to dosimetry, primary and secondary responses at the molecular, cellular, and tissue biology levels, epidemiology, definitions of risk, and the practical and regulatory applications of these issues including their biomedical and social consequences. Of major concern was the present state of knowledge about cancer risk and other risks in humans following intentional or accidental exposures to low doses and low dose-rates of ionizing radiation (below about 100 mSv accumulated dose). This includes low dose exposures which occur during radiation therapy in tissues located outside of the irradiated volume. The interdisciplinary approach of this workshop featured discussions rather than formal presentations in ten separate consecutive sessions. Each session was led by chairpersons, listed in the opening of the workshop, which introduced topics, facts and posed relevant questions. The content of each session is given by a brief summary followed by the abstracts from the primary discussants in the session as has been presented in the previous section. This manuscript provides additional review and discussion of the sessions and tracks the topics and issues discussed as follows: • Energy deposition through particle tracks in tissues. • Energy deposition and primary effects in tissues. • Consequences of experimental advances in radiobiology • Non-targeted radiation effects. • System biological considerations. • Propagation of perturbations in the system. • Immediately operating protections. • Delayed stress response protections • Low-dose induced adaptive protections. • Integrated defenses against cancer. • Endogenous versus radiogenic cancer. • The epidemiological dilemma. • Dose-risk functions for different exposure modalities. • Implications for research. • Implications for regulation and protection. A brief summary of the discussions and results on each of these topics and issues is presented in this paper. Additional details of these discussions are provided in the workshop session summaries grouped into topics and followed by applicable abstracts/synopses submitted by the workshop participants.

Feinendegen, Ludwig E.↗

Superconvergence of Online Optimization for Model Predictive Control

We develop a one-Newton-step-per-horizon, online, lag-L, model predictive control (MPC) algorithm for solving discrete-time, equality-constrained, nonlinear dynamic programs. Based on recent sensitivity analysis results for the target problems class, we prove that the approach exhibits a behavior that we call superconvergence; that is, the tracking error with respect to the full horizon solution is not only stable for successive horizon shifts, but also decreases with increasing shift order to a minimum value that decays exponentially in the length of the receding horizon. The key analytical step is the decomposition of the one-step error recursion of our algorithm into algorithmic error and perturbation error. We show that the perturbation error decays exponentially with the lag between two consecutive receding horizons, while the algorithmic error, determined by Newton’s method, achieves quadratic convergence instead. Overall this approach induces our local exponential convergence result in terms of the receding horizon length for suitable values of L. In conclusion, numerical experiments validate our theoretical findings.

97 MATHEMATICS AND COMPUTING↗

A Planetary Defense System For Responsive Space Missions

As King et al succinctly write, “Collision between the Earth and small objects in the solar system are known to occur regularly, and can result in extinction-level events at their most energetic or more commonly widespread loss of life or economic destruction even for relatively low-energy impacts.” Currently, the JPL Sentry System and the NASA NEO Surveyor mission track, identify, and monitor potential asteroid threats. The JPL Sentry System4 is an automated collision monitoring system which scans the current asteroid catalog for potential impact trajectories with Earth. A 2017 study led by P. Tricarico titled “The near-Earth asteroid population from two decades of observations” analyzes the combined observations of nine leading asteroid surveys. The NASA NEO Surveyor mission seeks to identify 90% of near-Earth objects (NEO) with diameters greater than 140 meters (460 feet) within 10 years. The NEO Surveyor combines data from two infrared imaging detectors to measure NEO size, composition, shape, rotational state, and orbits. Recently, the NASA Double Asteroid Redirection Test (DART) mission successfully altered the orbit of asteroid moon Dimorphos in 2022. This demonstrated that orbit alteration is possible. Thus, collisions between the Earth and asteroids are both likely and demonstrate potential for great harm. There is ongoing work to identify, catalog, and track potential threats. However, when a threat is identified there is not yet a system in place to target the threatening asteroid and defend the planet from potentially existential threats. Building on the DART Mission, we explore a planetary defense system to mitigate asteroid threats.

42 ENGINEERING↗