Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tensile Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Influence of Boron on Austenite to Ferrite Transformation Behavior of Low Carbon Steel Under Continuous Cooling

In the current work, the influence of boron on austenite to ferrite transformation behavior under continuous cooling condition and its associated features, e.g., final microstructure, mechanical properties, etc., in low carbon steel has been studied. The steels (C 0.04 wt.%, B 10-100 ppm) prepared in an open air laboratory furnace showed identical microstructures having ferrite grains of 20-25 µm. However, tensile test data indicate variation of yield strength and ultimate tensile strength with boron content. The yield point elongation and strain aging index both were found to decrease with increase in boron content or boron-to-nitrogen ratio. As the boron nitride precipitates stimulate the nucleation of ferrite phase, the dilation curves show an increase in austenite to ferrite transformation start temperature with boron content. The resulting microstructure and hardness value also corroborate the finding. Transmission electron microscopy findings revealed the presence of ultra-fine boron nitride (BN) precipitates in both grain boundary and grain body of the steel having boron concentration of 30 ppm and beyond. The presence of these precipitates also increased with boron content. Based on austenite decomposition behavior, related microstructure and hardness values it is conjectured that these BN precipitates may act as nucleating agent for polygonal ferrite during austenite decomposition, thereby softening the steel during fast cooling.

36 MATERIALS SCIENCE↗

Design and Evaluation of an Experimental Technique for Mechanical and Fatigue Testing of Sub-Sized Samples

Some recently developed processing techniques allow fabrication of small specimens. The fatigue behavior of these small samples cannot be characterised according to the existing standards due to size limitations. The main objective of the present work is to develop an original technique for both mechanical and fatigue testing of sub-sized specimens produced by a high pressure torsion (HPT) method. The fatigue behavior of the sub-sized Ti-6Al-4 V samples, made from HPT-processed disks, is compared with that of the standard samples prepared according to the ASTM standards. Finite element method (FEM) analysis of the stress distribution under applied static load, for both sub-sized specimens and grips designed for their testing, is performed. Good agreement between the outcomes of tensile testing of the standard ASTM samples and sub-sized samples is observed. Fatigue data, represented by Wöhler curves for both types of samples, showed significant divergence of high cycle fatigue properties caused by incompliance of specimen geometries and surface/defect size ratio. The obtained results can be used to scale up the fatigue behavior from sub-sized specimens to the standard ones, as well as to predict the fatigue behavior of the bulk nanostructured metals and alloys produced by HPT.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of twin boundaries in an Fe–17.5Mn–0.56C twinning induced plasticity steel

A twinning-induced plasticity steel of composition Fe–17.5 wt.% Mn–0.56 wt.% C–1.39 wt.% Al–0.24 wt.% Si was analyzed for the purpose of characterizing the relationship between tensile strain and deformation twinning. Tensile samples achieved a maximum of 0.46 true strain at failure, and a maximum ultimate tensile strength of 1599 MPa. Electron backscatter diffraction (EBSD) analysis showed that the grain orientation rotated heavily to < 111 > parallel to the tensile axis above 0.3 true strain. Sigma 3 misorientations, as identified by EBSD orientation measurements, and using the image quality maps were used to quantify the number of twins present in the scanned areas of the samples. The image quality method yielded a distinct positive correlation between the twin area density and deformation, but the orientation measurements were unreliable in quantifying twin density in these structures. Quantitative analysis of the twin fraction is limited from orientation information because of the poor spatial resolution of EBSD in relation to the twin thickness. The EBSD orientation maps created for a thin foil sample showed some improvement in the resolution of the twins, but not enough to be significant. Measurements of the twins in the transmission electron microscopy micrographs yielded an average thickness of 23 nm, which is near the resolution capabilities of EBSD on this material for the instrumentation used. Electron channeling contrast imaging performed on one bulk tensile specimen of 0.34 true strain, using a method of controlled diffraction, yielded several images of twinning, dislocation structures and strain fields. A twin thickness of 66 nm was measured by the same method used for the transmission electron microscopy measurement. It is apparent that the results obtain by electron channeling contrast imaging were better than those by EBSD but did not capture all information on the twin boundaries such as was observed by transmission electron microscopy. - Highlights: • Performed tensile tests to assess mechanical performance of TWIP alloy • Analyzed tensile specimens using EBSD, TEM, and ECCI • EBSD showed that most twinning occurred at or near the < 111 >//TA orientation. • EBSD, TEM and ECCI were used to measure average twin density. • Compared spatial resolution of EBSD, ECCI and TEM for the instrumentation used.

36 MATERIALS SCIENCE↗

Strengthening mechanisms for microstructures containing unimodal and bimodal γ' precipitates in ATI 718Plus

Here, the influence of γ' precipitate size distribution on the deformation mechanisms under tensile loading in ATI 718Plus was studied. A set of aging treatments within the temperature range of 720 °C–900 °C was performed on solution-treated samples to obtain various γ' precipitate size distributions. Unimodal and bimodal γ' precipitate size distributions were achieved through single-step and two-step aging sequences, respectively, and such microstructures were tensile tested to failure to assess their yield strength, ultimate tensile strength, and elongation-to-failure. Some of the tensile samples were interrupted after achieving 3–4 % plastic strain, and the deformed microstructures were examined using transmission electron microscopy to investigate the γ' precipitate-dislocation interactions. For the unimodal γ' precipitate size distribution samples with the smaller γ' precipitates (radius ~ 7 nm), dislocations sheared through the precipitates. Both dislocation loops and paired dislocations were observed for the microstructures containing larger γ' precipitates (radius ~ 24 nm). The microstructure containing a bimodal γ' precipitate size distribution, which included average γ' precipitate radii of ~6 nm and ~28 nm, exhibited shearing as the dominant deformation mechanism, and this microstructure exhibited the highest strength values. The experimental observations were rationalized based on the theoretically-calculated critical resolved shear stress values for shearing and looping and a modified model for predicting the yield strength for bimodal microstructures was introduced.

36 MATERIALS SCIENCE↗

SNL/SRNL Joint Project on degradation of mechanical properties in structural metals and welds for GTS reservoirs

The objective of this project is to measure the hydrogen-affected fracture properties of structural welded metals exposed to hydrogen isotopes. The main goal of FY16 was to evaluate low-temperature effects on fracture properties of stainless steel welds pre-charged with hydrogen. Forged stainless steels consisting of 316L, 304L, and 21-6-9 welded with 308L filler metal were pre-charged and tested at 223 K at select displacement rates to evaluate fracture behavior over the lower STS temperature range. Reductions in fracture thresholds were observed for all stainless steel welds when samples were precharged with hydrogen; however, temperature effects were not observed in the 304L and 21-6-9 welds. Only 316L exhibited enhanced degradation at 223 K. In addition to fracture testing, tensile specimens were extracted from the weld region and tested at 296 K and 223 K in the hydrogen pre-charged condition. A slight increase in yield strength was measured in the pre-charged condition at 296K and 223 K for the three different welds. A reduction in total elongation of 3-11% was observed at 296 K, whereas reductions in total elongation from 50-64% were observed at 223 K. Microhardness and ferrite numbers were measured in the weld regions to try to elucidate the factors affecting fracture. Lastly, in collaboration with Savannah River National Laboratory (SRNL), weld and heat-affected zone bend specimens extracted from forged 304L and 21-6-9 stainless steel were supplied to SRNL and are in the final stages of sample preparation for subsequent tritium exposure, aging, and fracture testing. The collection of testing completed and planned between Sandia and SRNL contributes to the development of a comprehensive database of properties for materials as a function of hydrogen-isotope concentrations.

36 MATERIALS SCIENCE↗

Welded and Hydrogen Charged Zircaloy-4 and Welded Stainless Steel 347 Property Data and Microstructures for the Target Solution Vessel and Support Lines of SHINE

SHINE Medical Technologies is developing a facility that will produce molybdenum-99 for medical isotope procedures. As part of this facility, a metal tank, called the target solution vessel (TSV), will hold a uranyl sulfite solution. The TSV must withstand neutron irradiation near room temperature and potential corrosion from the aqueous solution. The large cylindrical TSV will be fabricated by welding and will have numerous pipes and connections also attached via welding. The vessel and those pipes will have varying thicknesses so both gas tungsten arc welding (GTAW) and flux-cored arc welding (FCAW) will be necessary to fabricate different sections. The original material under consideration for the TSV was Zircaloy-4 (Zry-4), but it is known to form a hydride which can degrade its mechanical properties. Thus, some investigation here is focused on the effects of hydrogen uptake in the Zry-4. Additionally, the alternative material being considered is AISI 347, a stainless steel. Both materials have little existing data for their neutron irradiation behavior below 100°C, and both have open questions on the weld behavior under neutron irradiation. Testing has focused on characterizing their weld properties with tensile tests and performing neutron irradiation of samples in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL).

07 ISOTOPE AND RADIATION SOURCES↗

Destructive Examination of Shipping Package 9975-02731

Destructive and non-destructive examinations were performed on the components of the package 9975-02731 as part of a comprehensive Savannah River Site surveillance program for plutonium materials stored in the K-Area Complex (KAC). The package stored nuclear materials in KAC for 13.8 years. Inspection of the package during opening in KAC noted one non-conforming condition: a large discolored area on the upper fiberboard subassembly. The package was subsequently transferred to Savannah River National Laboratory for more detailed examination. In addition to the observation noted in KAC, the following conditions were observed: (1) Axial gap of 1.021 inch slightly exceeded the 1 inch maximum criterion, and (2) Lead shield height exceeded drawing tolerance of 24.7 inch by 0.019 inch. Visual examination of the upper fiberboard assembly and analysis of the discolored fiberboard indicate the discoloration was due to wood glue residue. The physical, thermal, and mechanical properties of the fiberboard met the acceptance criteria and/or were within the range of previously tested fiberboard and baseline samples. The visual, microscopic and tensile testing results were consistent with previous O-ring and baseline Viton results. The lead shield surface was covered with corrosion product as observed on other shields but there was no evidence of excessive blistering, flaking, or spalling. Besides minor and expected corrosion, no evidence of a degraded condition was found in this package. Examination of the 9975-02731 corroborates existing evidence that the 9975 package is robust and the components can perform their expected functions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Peel resistance of adhesive bonds accurately measured

Strength of adhesive bond between layers of laminated material is tested by peel force to the facing with a tensile testing machine. Testing jig has stainless steel rollers which constrain material to move horizontally while maintaining free end of facing at constant 90 deg angle.

Source record↗

Loading rate effect on interlaminar fracture toughness of a thermoplastic composite

A study was undertaken to investigate the loading rate effect on delamination fracture initiation toughness of a thermoplastic composite. For this purpose, double cantilever beam specimens of graphite/PEEK were tested in a displacement controlled mode using an Instron tensile test machine. Specimens were loaded at various crosshead speeds ranging from 0.05 cm/min to 100 cm/min. The interlaminar fracture toughness was found to decrease with increasing loading rate, and this decrease was more than one hundred percent over the five decades of loading rate employed.

Mall, S.↗

Hydrostatic Stress Effect on the Yield Behavior of Inconel 100

Classical metal plasticity theory assumes that hydrostatic stress has negligible effect on the yield and postyield behavior of metals. Recent reexaminations of classical theory have revealed a significant effect of hydrostatic stress on the yield behavior of various geometries. Fatigue tests and nonlinear finite element analyses (FEA) of Inconel 100 (IN100) equal-arm bend specimens and new monotonic tests and nonlinear finite element analyses of IN100 smooth tension, smooth compression, and double-edge notch tension (DENT) test specimens have revealed the effect of internal hydrostatic tensile stresses on yielding. Nonlinear FEA using the von Mises (yielding is independent of hydrostatic stress) and the Drucker-Prager (yielding is linearly dependent on hydrostatic stress) yield functions were performed. A new FEA constitutive model was developed that incorporates a pressure-dependent yield function with combined multilinear kinematic and multilinear isotropic hardening using the ABAQUS user subroutine (UMAT) utility. In all monotonic tensile test cases, the von Mises constitutive model, overestimated the load for a given displacement or strain. Considering the failure displacements or strains for the DENT specimen, the Drucker-Prager FEM s predicted loads that were approximately 3% lower than the von Mises values. For the failure loads, the Drucker Prager FEM s predicted strains that were up to 35% greater than the von Mises values. Both the Drucker-Prager model and the von Mises model performed equally-well in simulating the equal-arm bend fatigue test.

Allen, Phillip A.↗

Synchrotron Tomography of SiC/SiC Minicomposites to Observe and Quantify Damage Evolution

Composite performance is dictated by its microstructure – property relationships. For example, the characteristic response of ceramic matrix composites (CMCs) depends on the distribution of its constituents (i.e. fibers, matrix, fiber coatings, matrix cracks, and voids). Micro x-ray computed tomography (micro-CT) provides an opportunity to characterize the distribution of these constituents and to quantify the CMC microstructure in three-dimensions. To this end, In-situ micro-CT was performed at the Advanced Light Source (ALS) in combination with uniaxial tensile testing on SiC/SiC minicomposites. This work will describe the tensile load-dependent damage evolution within the microstructure of the SiC/SiC CMC specimens. The results from the micro-CT datasets can be used to develop micromechanical models that effectively capture damage initiation and progression in CMCs. In addition, details regarding the segmentation tools and techniques employed to understand and quantify these large tomography datasets will be presented.

Ashley Hilmas↗

A preliminary investigation of acousto-ultrasonic NDE of metal matrix composite test specimens

Acousto-ultrasonic (AU) measurements were performed on a series of tensile specimens composed of 8 laminated layers of continuous, SiC fiber reinforced Ti-15-3 matrix. The following subject areas are covered: AU signal analysis; tensile behavior; AU and interrupted tensile tests; AU and thermally cycled specimens; AU and stiffness; and AU and specimen geometry.

Kautz, Harold E.↗

Deformation behavior of HCP titanium alloy: Experiment and Crystal plasticity modeling

The deformation behavior of commercially pure titanium is studied using experiments and a crystal plasticity model. Compression tests along the rolling, transverse, and normal-directions, and tensile tests along the rolling and transverse directions are performed at room temperature to study the activation of slip and twinning in the hexagonal closed packed titanium. A detailed EBSD based statistical analysis of the microstructure is performed to develop statistics of both {10-12} tensile and {11-22} compression twins. A simple Monte Carlo (MC) twin variant selection criterion is proposed within the framework of the visco-plastic self-consistent (VPSC) model with a dislocation density (DD) based law used to describe dislocation hardening. In the model, plasticity is accommodated by prismatic, basal and pyramidal slip modes, and {10-12} tensile and {11-22} compression twinning modes. Thus, the VPSC-MC model successfully captures the experimentally observed activation of low Schmid factor twin variants for both tensile and compression twins modes. The model also predicts macroscopic stress-strain response, texture evolution and twin volume fraction that are in agreement with experimental observations.

36 MATERIALS SCIENCE↗

Tensile fracture characteristics of nanostructured ferritic alloy 14YWT

High temperature tensile fracture behavior has been characterized for the ferritic alloy 14YWT (SM10 heat) with the composition of Fe-14Cr-3W-0.4Ti (in wt.%) and strengthened by dispersion of nanometer-sized oxygen, titanium, and yttrium rich clusters. Tensile tests were performed at various temperatures ranging from room temperature to 1000 C in a vacuum condition using a nominal strain rate of 10-3s-1. Comparing with the existing oxide dispersion strengthened (ODS) steels such as Eurofer 97 and PM2000, the nanostructured alloy showed much higher yield and tensile strength over the test temperature range, but with lower elongation. Microstructural characterization for fractured tensile specimens was focused on the details of fracture morphology and mechanism to provide a feedback for process improvement. Below 600 C, the fracture surfaces exhibited a quasi-ductile behavior presented by a mixture of dimples and cleavage facets. At or above 600 C, however, the fracture surfaces were fully covered with dimples. The spherical particles that seemed to be oxide or carbide particles were found inside of dimples. It was notable that numerous microcracks were observed on the side surface of broken specimens. Formation of these microcracks is believed to be the main origin of the poor ductility of 14YWT alloy. It is suggested that any grain boundary strengthening measure is essential to improve the fracture property of the alloy.

36 MATERIALS SCIENCE↗

Ultra-pure nickel for structural components of low-radioactivity instruments

The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

47 OTHER INSTRUMENTATION↗

Investigation of Mechanical Properties of Parts Fabricated with Gas- and Water-Atomized 304L Stainless Steel Powder in the Laser Powder Bed Fusion Process

In this report the use of gas-atomized powder as the feedstock material for the Laser Powder Bed Fusion (L-PBF) process is common in the Additive Manufacturing (AM) community. Although gas-atomization produces powder with high sphericity, its relatively expensive production cost is a downside for application in AM processes. Water atomization of powder may overcome this limitation due to its low cost relative to the gas-atomization process. In this work, gas- and water-atomized 304L stainless steel powders were morphologically characterized through Scanning Electron Microscopy (SEM). The water-atomized powder had a wider particle size distribution and exhibited less sphericity. Measuring powder flowability using the Revolution Powder Analyzer (RPA) indicated that the water-atomized powder had less flowablility than the gas-atomized powder. Through examining the mechanical properties of L-PBF fabricated parts using tensile tests, the gas-atomized powder had significantly higher yield tensile strength and elongation than the water-atomized powder, however, their ultimate tensile strengths were not significantly different.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Origin, parameters, and underlying deformation mechanisms of propagating deformation bands in irradiated 316L stainless steel

Lüders-type propagating deformation bands were observed in specimens of irradiated 316L stainless steel samples removed from Spallation Neutron Source target vessels after service. Mechanical testing with digital image correlation (DIC) and in-situ tensile testing with scanning electron microscopy electron backscatter diffraction showed that the observed Lüders-type behavior was not related to the known transformation-induced plasticity or twinning-induced plasticity behavior. Instead, the phenomenon occurs at small local strain values before a significant amount of martensite or deformation twins appear in the microstructure. Microstructural analysis and in-situ mechanical test results suggest Lüders-type band formation and propagation were related to the appearance and evolution of defect-free channels—analogous to slip bands. A modified Swift equation with a Ludwigson-like component was offered to rationalize the phenomenon and model the strain-softening processes at small strain values. Finally, the results indicate complex microstructural processes and deformation mechanisms were active at small strain values and underline the benefits of advanced mechanical test approaches such as DIC.

36 MATERIALS SCIENCE↗