Search NASA⌕ Search

SEARCH · Search NASA

Results for “Test and analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

SAS4A/SASSYS-1 VERIFICATION AND VALIDATION TEST SUITE

SAS4A/SASSYS-1 is a safety analysis software package already under copyright by Argonne National Laboratory. There is interest from third-party users of the software to gain access to our internal verification and validation test suite. Therefore we are seeking to establish copyright over the test suite, which includes input files and reference results for hundreds of test cases that demonstrate functionality of the software. Making the test suite available to licensed users allows them to utilize the broad range of tests for commercial grade dedication activities needed to qualify the SAS4A/SASSYS-1 software under their own Software Quality Assurance program for use in a regulatory environment (e.g. with the Nuclear Regulatory Commission).

FANNING, THOMAS↗

Application Deconfliction Characterization and Alternatives Analysis

This report provides an overview of the domain space and solution techniques that could be used to create a robust, flexible app deconfliction service. Three approaches are reviewed with summaries of the characteristics, elements, and results from preliminary demonstrations of solution techniques based on each approach: 1) rules and heuristics, 2) cooperation, and 3) optimization. The strengths and weaknesses of each solution technique were explored through a set of numerical demonstrations on modified IEEE 123 node and 9500 node test feeders. An alternatives analysis of individual deconfliction elements was performed with each solution technique element evaluated against criteria reflecting the dynamic app environment, need to balance app objectives, and scalability issues versus the number of applications, setpoints, and distributed control areas. It is anticipated that a combined solution for a GridAPPS-D Deconfliction Service can be formulated using a combination of elements from each solution technique. The combined solution would combine 1) device control budgets to reduce the size of the solution space by constraining system setpoints to those will not result in accelerated degradation of physical assets, 2) system operations rules to constrain the solution space by eliminating setpoints that result in violations of system limits or operational best practices, 3) contextual status signals shared with or among apps such that they could update their desired setpoints based on the evolving context, 4) a mediator that incentivizes apps to come to a cooperative solution, and 5) Setpoint-informed optimization as a fallback mechanism if a cooperative solution cannot be agreed upon by applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effect of Coaxial Electrode Geometry on the Electric Field Enhancement Factor for a High Voltage Vacuum Gap

We present an experimental analysis of the change in the electric field enhancement factor with varying gap size and penetration depth (P.D) of cathode into anode for a coaxial vacuum gap, diagnosed using Fowler–Nordheim analysis and optical imaging via scanning electron microscope (SEM) and time integrated Digital single lens reflex camera (DSLR). Data were collected on the Coaxial Gap Breakdown Machine (240 A, 25 kV, 150 ns, 0.1 Hz). Experiments using five different gap sizes at nine different P.Ds are compared over runs comprising 50 shots for each case. The results show a strong link between enhancement factor and gap size, with P.D and surface topology. For large gap sizes, 150, 330, and 700 μm, the average enhancement factor value increases with increasing P.D. For smaller gap sizes, 50 and 100 μm, the average enhancement factor decreases with P.D. SEM imaging before and after plasma formation for each gap size allows for quantifying surface finish, microprotrusion growth, average blast diameter, and an estimation of the surface area breakdowns occupy. Time integrated DSLR imaging analysis of the gap at each shot allows for a determination of the distribution of breakdowns about the circumference of the gap for each case tested. Here, the Fowler–Nordheim analysis allows for a quantitative analysis of the surface roughness of all gap sizes tested. Results show that for large gap sizes, the gap geometry and increasing area of breakdown is the main cause for increasing average enhancement factor. For small gap sizes, the dominant driving factor for small average enhancement factors—that subsequently decrease with P.D—is significant changes in surface topology due to an increased number of breakdowns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Towards testing the theory of gravity with DESI: summary statistics, model predictions and future simulation requirements

Shortly after its discovery, General Relativity (GR) was applied to predict the behavior of our Universe on the largest scales, and later became the foundation of modern cosmology. Its validity has been verified on a range of scales and environments from the Solar system to merging black holes. However, experimental confirmations of GR on cosmological scales have so far lacked the accuracy one would hope for — its applications on those scales being largely based on extrapolation and its validity there sometimes questioned in the shadow of the discovery of the unexpected cosmic acceleration. Future astronomical instruments surveying the distribution and evolution of galaxies over substantial portions of the observable Universe, such as the Dark Energy Spectroscopic Instrument (DESI), will be able to measure the fingerprints of gravity and their statistical power will allow strong constraints on alternatives to GR. In this paper, based on a set of N-body simulations and mock galaxy catalogs, we study the predictions of a number of traditional and novel summary statistics beyond linear redshift distortions in two well-studied modified gravity models — chameleon f(R) gravity and a braneworld model — and the potential of testing these deviations from GR using DESI. These summary statistics employ a wide array of statistical properties of the galaxy and the underlying dark matter field, including two-point and higher-order statistics, environmental dependence, redshift space distortions and weak lensing. We find that they hold promising power for testing GR to unprecedented precision. The major future challenge is to make realistic, simulation-based mock galaxy catalogs for both GR and alternative models to fully exploit the statistic power of the DESI survey (by matching the volumes and galaxy number densities of the mocks to those in the real survey) and to better understand the impact of key systematic effects. Using these, we identify future simulation and analysis needs for gravity tests using DESI.

79 ASTRONOMY AND ASTROPHYSICS↗

Recent Developments at the Raft River Geothermal Field

The Raft River geothermal field, located in Cassia County in southwestern Idaho, is the site of a Department of Energy Enhanced Geothermal System project. U.S. Geothermal, Inc. currently produces about 11 MWe from Precambrian metamorphic rocks. These lie beneath ~5,000 ft of Quaternary and Tertiary volcaniclastic and volcanic deposits. Maximum temperatures range from 271°F to 300°F. Well RRG-9 ST1, the well targeted for stimulation is located approximately 1 mile south of the main bore field. The open hole section of the well, from 5,551 to 5,900 ft MD, consists of Precambrian Elba Quartzite, the stimulation target, granite and minor diabase. Prior to setting the casing acoustic, gamma ray, and density logs were run. After completing the well, a step rate/step down test was conducted. The maximum injection rate achieved was 18 bpm at a wellhead pressure of 1,150 psig. A borehole televiewer run in the open hole section showed evidence of more than eighty fractures. The majority of these fractures trend from N20⁰W to N20°E and dip from 40° to 60°W. Permeable fractures were encountered in the Elba Quartzite at 5,640-5,660 ft MD. Analysis of the injection test indicates that the minimum in-situ principal stress in this zone is 3,050-3,200 psi, corresponding to a fracture gradient of 0.59-0.62 psi/ft. A discrete fracture network model was developed using measured and inferred fracture orientations, distributions and dimensions. A three-phase stimulation program is proposed for RRG-9 ST-1. During the first two stages, water at 140°F, and later 40°F, will be injected to pre-condition and thermally fracture the reservoir. Here, the third stage will consist of a high rate, large volume conventional hydraulic stimulation.

Bradford, Jacob↗

Status of New Models Hosted on the Virtual Test Bed (VTB) in 2024

The National Reactor Innovation Center (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. It is in development in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished by three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: 1. A documentation website detailing the models (https://mooseframework.inl.gov/virtual_test_bed). 2. A GitHub repository that hosts the corresponding files (https://github.com/idaholab/virtual_test_bed). Previous documentation on the models hosted in the VTB can be found in [1,2,3,4]. These references also include additional background information on the various NEAMS codes showcased in the VTB (which is omitted here for brevity). This paper primarily provides a status update of the most recent additions to the repository.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of Leach-Burn-Leach Round-Robin Test Results

Tristructural isotropic (TRISO) coated particle fuel is of interest to multiple member states associated with the Generation IV International Forum (GIF). Qualification and acceptance testing of TRISO fuel includes the determination of particle defect fractions and impurities in the as-fabricated TRISO fuel particle and/or composited fuel form, which are typically determined using burn-leach (BL) or leach-burn-leach (LBL) analysis methods. A round-robin test focusing on LBL analysis was undertaken by the GIF Very High Temperature Reactor System Fuel and Fuel Cycle Project Management Board. Participating in this LBL round-robin test were research staff from the Institute of Nuclear and New Energy Technology (INET) in the People’s Republic of China, the Korean Atomic Energy Research Institute (KAERI) in the Republic of Korea, and Oak Ridge National Laboratory (ORNL) in the United States of America. The motivation of this LBL benchmarking exercise was to explore consistency in results generated by LBL and to elucidate the potential influence of variations in the procedures used by the participating members on the accurate determination of the measured fuel properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Infrastructure improvements in the National Reactor Innovation Center Virtual Test Bed

The National Reactor Innovation Center’s (NRIC) mission is to support deployment of novel reactor concepts. This is achieved by providing physical and virtual spaces for building and testing various components, systems, and complete pilot plants. The Virtual Test Bed (VTB) represents the virtual counterpart to the physical test bed. The VTB is being developed in collaboration with the Department of Energy’s (DOE) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. The mission of the VTB is to accelerate the deployment and licensing of advanced reactors by leveraging state-of-the-art modeling and simulation (M&S) tools developed by the DOE NEAMS program. This is accomplished via three primary means: (1) openly hosting simulations that showcase analysis capabilities, (2) continuously testing the models hosted against code updates to avoid deprecation, and (3) filling key M&S gaps that are relevant for the physical NRIC test beds. The VTB repository consists of two sub-entities: • A documentation website detailing the models: https://mooseframework.inl.gov/virtual_test_bed • A GitHub repository that hosts the corresponding files: https://github.com/idaholab/virtual_test_bed. This paper presents the infrastructure added to the VTB in the last two fiscal years. Additional information about the VTB can be found in various publications [1, 2, 3, 4, 5, 6, 7, 8].

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Model bias in simulating major chemical components of PM 2.5 in China

High concentrations of PM 2.5 (particulate matter with an aerodynamic diameter less than 2.5 µm) in China have caused severe visibility degradation. Accurate simulations of PM 2.5 and its chemical components are essential for evaluating the effectiveness of pollution control strategies and the health and climate impacts of air pollution. In this study, we compared the GEOS-Chem model simulations with comprehensive datasets for organic aerosol (OA), sulfate, nitrate, and ammonium in China. Model results are evaluated spatially and temporally against observations. The new OA scheme with a simplified secondary organic aerosol (SOA) parameterization significantly improves the OA simulations in polluted urban areas, highlighting the important contributions of anthropogenic SOA from semivolatile and intermediate-volatility organic compounds. The model underestimates sulfate and overestimates nitrate for most of the sites throughout the year. More significant underestimation of sulfate occurs in winter, while the overestimation of nitrate is extremely large in summer. The model is unable to capture some of the main features in the diurnal pattern of the PM 2.5 chemical components, suggesting inaccuracies in the presented processes. Potential model adjustments that may lead to a better representation of the boundary layer height, the precursor emissions, hydroxyl radical concentrations, the heterogeneous formation of sulfate and nitrate, and the wet deposition of nitric acid and nitrate have been tested in the sensitivity analysis. The results show that uncertainties in chemistry perhaps dominate the model biases. The proper implementation of heterogeneous sulfate formation and the good estimates of the concentrations of sulfur dioxide, hydroxyl radical, and aerosol liquid water are essential for the improvement of the sulfate simulation. The update of the heterogeneous uptake coefficient of nitrogen dioxide significantly reduces the modeled concentrations of nitrate. However, the large overestimation of nitrate concentrations remains in summer for all tested cases. The possible bias in the chemical production and the wet deposition of nitrate cannot fully explain the model overestimation of nitrate, suggesting issues related to the atmospheric removal of nitric acid and nitrate. A better understanding of the atmospheric nitrogen budget, in particular, the role of the photolysis of particulate nitrate, is needed for future model developments. Moreover, the results suggest that the remaining underestimation of OA in the model is associated with the underrepresented production of SOA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis of Powered Air-Purifying Respirator (PAPR) Cartridge Performance Testing on Hanford Tanks SX-101 and SX-104 Volume 1

Washington River Protection Solutions (WRPS) conducted tests using two types of chemical cartridges for use in powered air-purifying respirators (PAPR) to determine the period of time that the cartridges would provide adequate performance for PAPRs used to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors exiting the headspaces of Hanford tanks SX-101 and SX-104. The Occupational Safety and Health Administration (OSHA) considers cartridge testing to be a valid approach for establishing cartridge change schedules. Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to assure measurement and/or control of the key variables OSHA identified as important to estimate the cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted from June 16-17, 2017, from headspace vapors from Hanford tank SX-101 and from June 23-24, 2017, from Hanford tank SX-104. Headspace vapors were fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose high-efficiency PAPR cartridges, MSA-TL (TL1) (MSA Safety Inc., Pittsburgh, Pennsylvania) and 3M FR-57 (TL2) (3M Company, Maplewood, Minnesota) were assessed on separate days. Sample media (i.e., sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. The key conclusions from the analysis are described below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Distributed Optical Fiber Sensor Systems: Application to Natural Gas Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of pipelines. Considering the low backscattering level of standard single-mode fiber as fiber under test, a Rayleigh enhanced optical fiber embedded within the tight-buffered cable is demonstrated in field testing. We analyzed the increased backscattering fiber cable's vibration performance to the conventional single-mode telecom fiber using a custom-built Φ-OTDR interrogator system. Thereafter, using a 4-inch steel pipeline with a flow rate of 5, 10, 15, and 20 ft/s and a fixed pressure level of 1000 psi, we field-tested the sensor system for monitoring natural gas pipeline acoustic vibrations. We also field tested Brillouin optical time domain analysis (BOTDA) system for pipeline hoop strain monitoring under various pressure conditions. The pilot-scale testing results presented in this study suggested that pipeline operators can accurately perform flow monitoring, leak detection, and pressure monitoring for pipeline integrity monitoring.

Lalam, Nageswara↗

Comparative analysis of various pretreatments to mitigate fouling and scaling in membrane distillation

Membrane distillation (MD) has shown strong promise for treating hypersaline produced water (PW) streams. Scaling and fouling on the membrane surface, however, have been identified as major challenges for commercialization and widespread application. The focus of this study was to first identify the nature of foulants and scalants on the membrane surface and then investigate the pretreatment strategies that mitigate the extent of fouling and scaling on the membrane surface. Vacuum MD (VMD) was selected for this study because of its higher flux at more moderate feed temperatures that eventually leads better assessment of fouling and scaling on the membrane surface. VMD flux tests were carried out with three different real PW samples at total dissolved solids concentrations in the range of 120-160 g/L. It was found that an efficient pretreatment prior to MD is required to mitigate the fouling potential of the organic matter, mostly suspended constituents, in PW samples. Suspended organics fouled and quickly wetted the MD membrane. Major conventional treatments, including filtration, oxidation, coagulation, air floatation, and aeration were investigated to pretreat the PW before VMD tests. A comprehensive comparative analysis is presented showing that the ultrafiltration and coagulation pretreatments displayed the best performance in mitigating the fouling and scaling, while oxidative pretreatment was found to be effective in reducing the iron concentration to less than 5 ppm. The surface of scaled membranes was carefully characterized to further evaluate the performance of each pretreatment. The components that had the highest tendency to precipitate on the membrane surface were identified as strontium sulfate, calcium carbonate, sodium chloride, iron oxide, and silica. In closing, these findings are supported by thermodynamic estimation of the saturation index.

42 ENGINEERING↗

Product Consistency Test Results for the LXC-Series Glasses

This report provides chemical analysis of a series of Product Consistency Test (PCT) leachates from simulated nuclear waste glasses. The resulting data will be used in the development of improved property/composition models. For some of the glass leachates, minor scatter among the triplicate values of some analytes was observed. For other leachates, there were more significant differences among the triplicate values. A review of the PCT data noted that there was little difference between the normalized values on the basis of targeted or measured glass composition. Several of the canister centerline cooled study glasses have NC i values that are greater than the Hanford Tank Waste Treatment and Immobilization Plant immobilized low-activity waste constraint of 4 g/L for B and Na. The results of these glasses will help ensure the ability of advanced glass performance models to appropriately predict acceptable compositions. For many of the study glasses, heat treatment had only a marginal impact on the NC i values. The samples of the Environmental Assessment (EA) reference glass included with each PCT set had generally consistent NC i values. The release rates for boron and sodium, and for sodium and silicon were highly correlated for the study glasses, while for the other analytes, less correlation was observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Evaluation of Machine Learning Techniques for Isotope Identification Contextualized by Training and Testing Spectral Similarity

Precise gamma-ray spectral analysis is crucial in high-stakes applications, such as nuclear security. Research efforts toward implementing machine learning (ML) approaches for accurate analysis are limited by the resemblance of the training data to the testing scenarios. The underlying spectral shape of synthetic data may not perfectly reflect measured configurations, and measurement campaigns may be limited by resource constraints. Consequently, ML algorithms for isotope identification must maintain accurate classification performance under domain shifts between the training and testing data. To this end, four different classifiers (Ridge, Random Forest, Extreme Gradient Boosting, and Multilayer Perceptron) were trained on the same dataset and evaluated on twelve other datasets with varying standoff distances, shielding, and background configurations. A tailored statistical approach was introduced to quantify the similarity between the training and testing configurations, which was then related to the predictive performance. Wilcoxon signed-rank tests revealed that the OVR-wrapped XGB significantly outperformed the other algorithms, with confidence levels of 99.0% or above for the 133Ba, 60Co, 137Cs, and 152Eu sources. The findings from this work are significant as they outline techniques to promote the development of robust ML-based approaches for isotope identification.

domain adaptation↗

ECAR-5367 Rev 0 Hydraulic Assessment of the Primary Coolant Test System Design

A MARVEL thermal-hydraulic analysis team has developed the computational fluid dynamicsmodel of the Primary Coolant Test (PCAT) system design based on the CAD drawing providedfrom INL PCAT design team. This ECAR addresses the hydraulic system characteristics(pressure loss and flow distribution) in the various sub-components of the PCAT design. Thisreport provides potential design optimization direction on the PCAT test. Most importantly, thisreport evaluates the feasibility of the natural circulation at the targeted heat balance between thecore and heat sink design.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗