Search NASASearch

SEARCH · Search NASA

Results for “Thermal Design for Spacecraft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

2,970 records · Page 33

Elastic Modulus Measurement at High Temperatures for Miniature Ceramic Samples Using Laser Micro-Machining and Thermal Mechanical Analyzer

In this paper, we demonstrate a method of measuring the flexural elastic modulus of ceramics at an intermediate (~millimeter) scale at high temperatures. We used a picosecond laser to precisely cut microbeams from the location of interest in a bulk ceramic. They had a cross-section of approximately 100 μm × 300 μm and a length of ~1 cm. They were then tested in a thermal mechanical analyzer at room temperature, 500 °C, 800 °C, and 1100 °C using the four-point flexural testing method. We compared the elastic moduli of high-purity Al2O3 and AlN measured by our method with the reported values in the literature and found that the difference was less than 5% for both materials. This paper provides a new and accurate method of characterizing the high-temperature elastic modulus of miniature samples extracted from representative/selected areas of bulk materials.

Chemistry

Low thermal budget dopant activation in shallow junctions of implanted Si via Tunable plasma enhanced annealing

Low thermal budget (LTB) annealing has become increasingly critical for shallow junctions as semiconductor devices are scaled down. Plasma Enhanced Annealing (PEA) has emerged as a promising LTB annealing process, however its mechanisms remain unclear. In this study, arsenic and boron implanted silicon wafers were subjected to helium or argon ion bombardment generated by annealing plasmas under controlled ion energies and doses in a home-built annealing reactor. The structural and electrical changes were characterized by four-point probe measurements, secondary ion mass spectrometry, Raman spectroscopy and spectroscopic ellipsometry. A pronounced reduction in sheet resistance, accompanied by a decrease in the damage layer thickness demonstrates the surface selective annealing capability of PEA process. Comparative studies using He and Ar plasmas and related ion bombardment reveal a dependence of activation efficacy on both ion species and the dopant implantation profile. Furthermore, a multi-step annealing mechanism is proposed, consisting of an initial (low dose) structural recovery stage followed by the generation of “extended” defects and concluded at large doses by an enhanced dopant activation. The proposed annealing kinetics are thought to be controlled by ion flux, dose and energy. Finally, these results highlight PEA as an effective, surface-selective, LTB approach for shallow-dopant activation and near surface annealing, and provide mechanistic insights into PEA processes.

dopant activation

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Stabilizer Scars

Quantum many-body scars are eigenstates in nonintegrable isolated quantum systems that defy typical thermalization paradigms, violating the eigenstate thermalization hypothesis and quantum ergodicity. Here, we identify exact analytic scar solutions in a 2+1 dimensional lattice gauge theory in a quasi-1D limit as zero-magic resource stabilizer states. Our results also highlight the importance of magic resources for gauge theory thermalization, revealing a connection between computational complexity and quantum ergodicity.

eigenstate thermalization

Aerosol-deep convection interaction based on joint cell-thermal tracking in Large Eddy Simulations during the TRACER campaign

In cumulus clouds, aerosol concentrations control cloud droplet concentrations, modifying cloud radiative properties, precipitation processes, and cloud electrification. However, mechanisms of aerosol-deep convection interactions are not well understood due to complex cloud dynamics and microphysics. We investigate the interaction of aerosols with isolated deep convection using Large Eddy Simulations of two cases during the TRacking Aerosol Convection interactions ExpeRiment (TRACER) near Houston, Texas, using a joint cell-thermal tracking algorithm. Cumulus thermals are droplet generators, since supersaturation and droplet nucleation coincide with thermal centers, where the strongest updrafts occur. Primary ice crystal formation does not take place inside thermals, but at layers where previous thermals detrained moisture. As subsequent thermals containing supercooled droplets penetrate these layers, hail and graupel form at or near these thermals. Higher aerosol concentrations result in higher droplet concentrations that suppress drizzle, delay warm rain processes, and transport more moisture aloft. This increases snow and ice amount, as well as graupel and hail, leading to more lightning. Polluted thermals initiate at slightly higher altitudes, and are slightly larger and faster, suggesting a weak invigoration. We also find more thermals per cell, but fewer isolated cells, since convection is more aggregated and intense, especially near the end of the 24 h simulation. Non-linear mesoscale feedback likely triggered by temperature and moisture responses to aerosol-thermal interactions causes the aggregation. Time-lagged aerosol-reinitialization experiments show that the mesoscale response is the predominant forcing for the invigoration. These changes happen within one day, on a smaller scale than previously suggested.

54 ENVIRONMENTAL SCIENCES

Unravelling ultralow thermal conductivity in perovskite Cs2AgBiBr6: dominant wave-like phonon tunnelling and strong anharmonicity

Abstract Understanding the lattice dynamics and heat transport physics in the lead-free halide double perovskites remains an outstanding challenge due to their lattice dynamical instability and strong anharmonicity. In this work, we investigate the microscopic mechanisms of anharmonic lattice dynamics and thermal transport in lead-free halide double perovskite Cs 2 AgBiBr 6 from first principles. We combine self-consistent phonon calculations with bubble diagram correction and a unified theory of lattice thermal transport that considers both the particle-like phonon propagation and wave-like tunnelling of phonons. An ultra-low thermal conductivity at room temperature (~0.21 Wm −1 K −1 ) is predicted with weak temperature dependence( ~ T −0.34 ), in sharp contrast to the conventional ~T −1 dependence. Particularly, the vibrational properties of Cs 2 AgBiBr 6 are featured by strong anharmonicity and wave-like tunnelling of phonons. Anharmonic phonon renormalization from both the cubic and quartic anharmonicities are found essential in precisely predicting the phase transition temperature in Cs 2 AgBiBr 6 while the negative phonon energy shifts induced by cubic anharmonicity has a significant influence on particle-like phonon propagation. Further, the contribution of the wave-like tunnelling to the total thermal conductivity surpasses that of the particle-like propagation above around 310 K, indicating the breakdown of the phonon gas picture conventionally used in the Peierls-Boltzmann Transport Equation. Importantly, further including four-phonon scatterings is required in achieving the dominance of wave-like tunnelling, as compared to the dominant particle-like propagation channel when considering only three-phonon scatterings. Our work highlights the importance of lattice anharmonicity and wave-like tunnelling of phonons in the thermal transport in lead-free halide double perovskites.

Chemistry

Coexistence of Synchronization and Stochasticity in Thermally Coupled Mott Oscillators

Synchronization is conventionally regarded as a mechanism for suppressing variability and enforcing order in coupled systems, from pendula and lasers to neurons and electronic oscillators. Here, we show that synchronization can also embed stochasticity at finer scales. We observe this phenomenon in thermally coupled VO 2 neuristors, where robust in-phase synchronization at the microsecond scale coexists with spike onset fluctuations at the nanosecond scale, with no fixed leader. The coexistence of order and disorder originates from stochastic domain-level physics of the insulator–metal and metal–insulator transitions, where local variations in transition temperature drive cycle-to-cycle randomness in nucleation, percolation, and relaxation. A stochastic domain model reproduces this effect by generating synchronized spike trains with random lead–lag jitter, and experimental interspike interval statistics confirm the persistence of fine-scale variability despite macroscopic phase locking. These findings establish that synchronization and stochasticity can coexist within the same physical platform, revealing hidden disorder within collective order. Furthermore, this insight reframes synchronization as not purely deterministic, but as a universal context where microscopic variability can persist, with implications for electronics, cryptography, and the fundamental physics of order–disorder coexistence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Enabling Mission Flexibility to Battery Driven Deep Space Endeavors With Generalized Battery-Health-Monitoring Using Physics-Based and Data-Driven Reduced-Order Models

The needs and requirements for an electrochemical energy storage for deep space exploration is well explored. It is often understood that different mission sites and environmental conditions require different battery chemistries or technologies. Additionally, various engineering solutions are deployed to overcome specific chemical challenges. One often overlooked need is the “health” monitoring of an electrochemical storage system. The term generalized health monitoring, as envisioned in this work, refers to the monitoring of various aspects such as electrode health, electrolyte health, reaction pathway health, cooling system health, sensor health, and BMS health [1]. Generalized health monitoring allows mission leads, engineers, and scientists to incorporate flexibility in mission designs, make on-the-fly mission changes, and extend the duration of science missions. Moreover, it enables automation and data-driven decision-making without compromising safety and performance. Recently, our group developed a hierarchy of thermal reduced-order models (TROM) by combining a physics-based modeling approach and data-driven model reduction techniques applied to flight data [2]. The resulting TROMs were found to be not only accurate but also identifiable from the flight data. Consequently, the coefficient of variance of the model parameters is small over the course of hundreds of flights, allowing for monitoring the parameter evolution trajectories as the battery ages and degrades. These parameters constitute the metrics of the generalized health of a battery. Monitoring their evolution allows such models to be used for anomaly detection and prognostics, improving early detection of abnormal behavior and thus enabling timely maintenance, longer battery life, and enhanced battery safety. For this presentation, the practicality of the thermal model will be validated on a pack of 14cells under various topology configurations such as 1S14P, 2P7S, 7S2P, and 1P14S. It is well known that manufacturing and non-uniform aging lead to variability in the performance of a cell, which is exacerbated by cell balancing during active load. Additionally, in extreme scenarios, the paramount objective is to complete the mission, regardless of the stresses on the battery. Topology-induced balancing issues further stress the battery. The goal of this study is to determine if the noise (identifiability) in the reduced-order thermal model parameters is sensitive to topology, cell spacing, cooling strategy, and manufacturing or age variability. The variability in cells is considered by assuming a multimodal distribution for microscopic parameters of a cell (such as porosity, tortuosity, reaction kinetics, volumetric thermal conductivity, and volumetric heat capacity). The compounded effect of manufacturing variability, topological selection, cooling strategies, and cell balancing ages each cell in a battery differently. The study aims to clarify whether the challenge in extracting maximum information depends on the minimum number of sensors or models used for data extraction.

Automation

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.

3D Woven Mid-Density Carbon Phenolic (3MDCP) Full-Scale Heatshield Development for Mars Sample Return (MSR) Earth Entry System (EES)

The Mars Sample Return (MSR) mission will be returning samples of Martian soil to Earth. The samples will be returned in the Earth Entry System (EES). The EES capsule is protected by a new thermal protection system; the 3-Dimensionally Woven, Mid-Density, Carbon Phenolic (3MDCP) material which is derived from the Heatshield for Extreme Entry Environment Technology (HEEET). The baseline 3MDCP design is a single piece thermal protection system that avoids the manufacturing and certification challenges associated with a tiled configuration. A 3MDCP heatshield begins as a flat woven preform that is formed to the final heatshield shape and then infused with phenolic resin. A NASA Ames lead team, in collaboration with Spirit Textiles (formerly TEAM Inc.), Fiber Materials Inc. (FMI, a Spirit AeroSystems Company), and Kratos SRE, has been developing and demonstrating the processes to fabricate the 3MDCP heatshield and characterize the resulting properties. The process of forming the flat woven preform into the final heatshield shape, a sphere-cone geometry with a 52.5° cone angle, involves local but substantial movement of the yarns in the weave. This results in continuous fibers across the single piece heatshield, albeit with property variations between different regions of the heatshield. This presentation will provide a high-level status of 3MDCP development for the MSR EES heatshield. This will include an overview of the manufacturing processes with an emphasis on the impact of forming on fiber orientation, material properties, and performance. Results comparing preliminary formed and flat materials will be shown. Additionally, the presentation will layout the broader plan for property testing and tie-in to aerothermal performance.

Peter Edward Marshall

Synthesis and application of thermally responsive nanofiber coatings for overtemperature monitoring

This study presents a one-pot synthesis route to organometallic nanofibers based on copper thiolate, exhibiting distinctive chemical and physical characteristics. Electron microscopy analysis of morphology and composition revealed 2-10 μm-long, 50-90 nm-diameter hollow and non-hollow fibers composed of copper, sulfur, oxygen, hydrocarbon, and chlorine. Thermogravimetric analysis showed a pronounced mass loss within 120°C-135°C. To elucidate the thermal responsive pathways, the nanofibers were characterized before and after heating. X-ray photoelectron spectroscopy indicates that an initially mixed Cu(I)/Cu(II) oxidation states transition to predominantly Cu(I) upon heating. A layer of nanofiber was coated on battery pouch foil and evaluated as a candidate thermally sensitive coating. At elevated temperature (100-130°C), nanofiber coating released volatile organic compounds, sulfide and sulfur dioxide as detected using multiple gas sensors. This thermally responsive gas release/sensing approach provides a potential large-area temperature monitoring strategy, which is particularly relevant where direct temperature measurements of individual batteries is impractical. The results established proof of concept for nanofiber-coated battery pouch foil as overtemperature warning platform that can provide alerts when surface temperatures exceed a critical threshold. More broadly, the ability to form interconnected fiber networks positions copper thiolate nanofiber coatings as promising materials for advanced applications.

Ihala Gamaralalage, Chanaka [ORNL] (ORCID:00000002

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Riddles About the Origin and Thermal History of the Moon

Analyses of lunar rocks have confirmed that the interior of the Moon has been subjected to magmatic differentiation, as has been determined by calculation of the thermal history of the Moon. However, it appears that differentiation occurred so early that it could not have been related to heating by long-lived radioactive elements, but rather indicates a high initial temperature of the Moon. The reasons for the high initial temperature remain unknown. The presence of a central, partially melted area revealed by seismic observations forces us to reject convective models of the Moon, while the dimensions of this area, together with the measured heat fluxes from the interior, serve as "boundary conditions" for any new calculations of the thermal history for a two-layered differentiated model of the Moon operative over the past 3.5 billion years. If we start with the early differentiation of the Moon and the high content of long-lived radioactive elements in it, explanation of its current thermal properties represents no difficulty. But these prerequisites themselves remain unexplained. Due to the continuing controversy concerning the true nature of the process of magmatic differentiation of the Moon, estimation of the composition of the entire Moon on the basis of analyses of surface rock remains unreliable, and use of these estimates to clarify the origin of the Moon is premature. Existing hypotheses concerning the origin of the Moon encounter dynamic difficulties, as well as difficulties with explanation of the high initial temperature, to say nothing of the difficulty involved in explaining the proposed differences in the composition of the Earth and Moon.

B Yu Levin

Thermally induced mimicry of quantum cluster excitations and implications for the magnetic transition in FePSe 3

In two dimensional magnets, the interplay of thermal fluctuations and spin anisotropy control the existence of long-range magnetic order. In the van der Waals antiferromagnets FePX 3 , orbital degeneracy in the 𝑡 2⁢𝑔 levels of the Fe 2+ ions in octahedral coordination yields strong uniaxial anisotropy, which stabilizes magnetic order up to 𝑇 ≈ 100 K. Recent inelastic neutron scattering measurements around the magnetic ordering transition have shown the existence of a broad spectrum of magnetic fluctuations with nontrivial momentum dependence, which has been interpreted as evidence for localized entangled cluster excitations. In this paper, we offer an alternative interpretation using classical nonlinear spin dynamics simulations. We present stochastic Landau Lifshitz dynamics simulations that reproduce the neutron scattering measurements of Chen et al. [npj Quantum Mater. 9, 40 (2024)] on FePSe 3 . These calculations faithfully explain the dynamical structure factor's momentum and energy dependence and point to a classical origin for the excitations observed in neutron spectroscopy and that the order-disorder transition can be understood in terms of thermal fluctuations overcoming the anisotropy energy.

Landau-Lifschitz-Gilbert equation

Decoupling thermal and irradiation effects on grain boundary segregation

Radiation-induced segregation (RIS) is most often measured by peak solute concentration at a boundary. However, this may give an incomplete picture of segregation quantity and phenomena. Radiation-induced and thermal segregation at grain boundaries was investigated in Fe-9.6 at.% Cr after 9 MeV Fe 3+ ion irradiation at 400 °C. The experimental results were compared to kinetic Monte Carlo (KMC) simulations. The study revealed that Cr enrichment (peak segregation) at the grain boundaries was comparable in both the irradiated and non-irradiated conditions, although irradiation resulted in broader segregation profiles in both experiments and simulations, indicating an overall increase in grain boundary segregation due to irradiation. This broadening is attributed to back diffusion into the grain interior. While it is an established phenomenon, this study offers a quantitative evaluation using experimental data and KMC modeling. Further, these results emphasize the importance of analyzing the entire segregation profile and decoupling the thermal and irradiation contributions to solute segregation.

Grain boundary segregation

Development of Hydrogen Burner for FT4000® Aeroderivative Engine - Final Report

This report details an effort to develop a retrofittable fuel/air injector for the FT4000® aeroderivative gas turbine that enables use of hydrogen as a carbon-free fuel for efficient power generation. The FT4000 engine’s low-NOx combustor was developed by Pratt & Whitney and RTX Technology Research Center with core technology from the Pratt & Whitney PW4000 turbofan aircraft engine. The current FT4000 production engine operates on either natural gas or No. 2 fuel oil with water injection to achieve high thermal efficiency and low emissions. This engine is fielded by Mitsubishi Power Aero and delivers 70 MW of power with a simple-cycle efficiency of over 41% when operating with wet compression. The work reported here advances the technology readiness level of the FT4000 combustor for operation with hydrogen, starting with an experimental assessment of the current production hardware with increasing hydrogen content mixed with natural gas and ending with improved nozzle concepts for fully robust operation with 100% hydrogen. High-pressure single-sector combustor rig tests have been completed, demonstrating the ability for the dual fuel nozzle to operate an FT4000 combustor on 100% hydrogen with low nitrogen oxide (NOx) emissions. Metal temperature measurements and video images of the flame structure from zero to 100% hydrogen highlight opportunities to improve the fuel nozzle robustness for high hydrogen conditions. The design of new fuel/air mixer concepts to improve durability and operability with high hydrogen levels was also completed. A total of eleven new concepts were developed and analyzed, ranging from modifications to the bill-of-materials nozzle to fully clean sheet designs. The concepts were evaluated with non-reacting and reacting flow evaluations to assess the performance of the new hardware designs. Non-reacting tests included Phase Doppler Particle Analysis (PDPA) for droplet size and velocity, mechanical patternation for liquid water flux, and planar laser induced fluorescence (PLIF) with acetone-seeding for gaseous fuel/air mixing characterization. Five scaled candidate fuel nozzle designs, in addition to a scaled bill-of-materials nozzle, were then successfully evaluated in an atmospheric pressure burner rig. The nozzles were evaluated for performance with natural gas, hydrogen/natural gas blends, and pure hydrogen. For 100% hydrogen, the nozzles were evaluated with and without water injection. Optical and infrared imaging of the flame and fuel nozzle was captured. NOx emissions were sampled from fixed emissions probes. The results show measurable differences between the various designs, and the data was used to down-select the two most promising designs to advance to future full pressure rig testing. Results from this study have cleared the current production FT4000 engines with dual fuel nozzles to operate at baseload power on blends of hydrogen mixed with natural gas and water. Two promising nozzle designs have been developed to enable fully robust operation with up to 100% hydrogen. These nozzles require validation at full baseload operating conditions before they can be introduced to the field.

03 NATURAL GAS

NASA's RPS Program Status Update and Future Outlook

Radioisotope Power Systems (RPS) have been safely providing the United States with the power to explore space for almost 65 years. NASA established the RPS Program in 2010 to support specialized science missions and potential future opportunities more effectively and efficiently. The RPS Program ensures the availability of RPS for the exploration of the solar system in environments where conventional solar or chemical power generation is impractical or impossible. NASA missions have utilized space nuclear power to explore planets, moons, and interstellar space, enabling missions to some of the deepest, darkest, and dustiest regions in the solar system and beyond. This scientific exploration has deepened our understanding of the solar system and our role within. The RPS Program, in partnership with the Department of Energy (DOE) Office of Nuclear Energy continues to operate as an interagency partnership to provide robust radioisotope power system solutions to spacecraft that conduct missions to extreme environments for science and exploration. This Program invests in systems and technologies to ensure that NASA maintains this capability well into the future and it manages processes that ensure the safe use and launch of these systems. This paper provides a synopsis of current activities of the RPS Program, and it introduces a focus on the commercialization of RPS to enable a variety of future mission applications.

radioisotope power systems

Tidal Tomography Reveals a Thermal Anomaly Beneath Mars’s Crustal Dichotomy

Mars undergoes seasonal tidal forcing as a result of its eccentric orbit and the tilt of its rotation axis relative to the Sun1. Response to this forcing produces temporal variations in the Martian gravity field and is sensitive to the internal structure of the planet2,3,4. Using tracking data from the Mars Global Surveyor (MGS), Mars Odyssey (ODY) and Mars Reconnaissance Orbiter (MRO) spacecraft5,6,7, we demonstrate that degree-3 components of the time-variable gravity field of Mars differ by up to 300% from predictions for a spherically symmetric planet8,9,10. These deviations can be explained if the effective shear modulus of the mantle varies by >20% over a roughly north–south pattern that closely aligns with the surface expression of the Martian crustal dichotomy11. On the basis of this correlation, we infer preservation of a 200–400 °C thermal anomaly in the present-day mantle below the southern highlands of Mars. This temperature variation could reflect regional mantle convection12,13 or insulation by the thick southern highlands crust of Mars that has persisted over several billion years14,15.

Mars