Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

New measurements of the lifetimes of excited states of {sup 55}Mn below 2.7 MeV

The lifetimes of the excited states of {sup 55}Mn between 1.5 and 2.7 MeV were measured using nuclear resonance fluorescence. The absolute lifetimes of the excited levels were determined from simultaneous measurements of manganese and aluminum. In this approach, the precisely known aluminum state serves as a means to normalize the results. Our findings differ from the evaluated level lifetimes in the Evaluated Nuclear Structure Data File (ENSDF), but agree with earlier nuclear resonance fluorescence measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relativistic Positron Creation Using Ultraintense Short Pulse Lasers

We measure up to 2x10{sup 10} positrons per steradian ejected out the back of {approx}mm thick gold targets when illuminated with short ({approx}1 ps) ultraintense ({approx}1x10{sup 20} W/cm{sup 2}) laser pulses. Positrons are produced predominately by the Bethe-Heitler process and have an effective temperature of 2-4 MeV, with the distribution peaking at 4-7 MeV. The angular distribution of the positrons is anisotropic. Modeling based on the measurements indicate the positron density to be {approx}10{sup 16} positrons/cm{sup 3}, the highest ever created in the laboratory.

07 ISOTOPE AND RADIATION SOURCES↗

Proton Distribution Radii of 12-19 C Illuminate Features of Neutron Halos

We report proton radii of 12-19 C densities derived from first accurate charge changing cross section measurements at 900A MeV with a carbon target. A thick neutron surface evolves from ~0.5 fm in 15 C to ~1 fm in 19 C. Also, the halo radius in 19 C is found to be 6.4±0.7 fm as large as 11 Li. Ab initio calculations based on chiral nucleon-nucleon and three-nucleon forces reproduce the radii well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed dc self-sustained magnetron sputtering

The magnetron sputtering has become one of the commonly used techniques for industrial deposition of thin films and coatings due to its simplicity and reliability. At standard magnetron sputtering conditions (argon pressure of {approx}0.5 Pa) inert gas particles (necessary to sustain discharge) are often entrapped in the deposited films. Inert gas contamination can be eliminated during the self-sustained magnetron sputtering (SSS) process, where the presence of the inert gas is not a necessary requirement. Moreover the SSS process that is possible due to the high degree of ionization of the sputtered material also gives a unique condition during the transport of sputtered particles to the substrate. So far it has been shown that the self-sustained mode of magnetron operation can be obtained using dc powering (dc-SSS) only. The main disadvantage of the dc-SSS process is its instability related to random arc formation. In such case the discharge has to be temporarily extinguished to prevent damaging both the magnetron source and power supply. The authors postulate that pulsed powering could protect the SSS process against arcs, similarly to reactive pulsed magnetron deposition processes of insulating thin films. To put this concept into practice, (i) the high enough plasma density has to be achieved and (ii) the type of pulsed powering has to be chosen taking plasma dynamics into account. In this article results of pulsed dc self-sustained magnetron sputtering (pulsed dc-SSS) are presented. The planar magnetron equipped with a 50 mm diameter and 6 mm thick copper target was used during the experiments. The maximum target power was about 11 kW, which corresponded to the target power density of {approx}560 W/cm{sup 2}. The magnetron operation was investigated as a function of pulse frequency (20-100 kHz) and pulse duty factor (50%-90%). The discharge (argon) extinction pressure level was determined for these conditions. The plasma emission spectra (400-410 nm range) and deposition rates were observed for both dc and pulsed dc self-sustained sputtering processes. The pulse characteristics of the voltage and current of the magnetron source during pulsed dc-SSS operation are shown. The presented results illustrate that a stable pulsed dc-SSS process can be obtained at a pulsing frequency in the range of 60-90 kHz and duty factor of 80%-90%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Redirection and reshaping of intense extreme-ultraviolet radiation

The goal to control short-wavelength radiation for the investigation and manipulation of ultrafast dynamics in quantum systems coevolves with the growing availability of extreme-ultraviolet (XUV) and x-ray sources from high-harmonic generation and free-electron lasers. Here, we present an XUV spatio-spectral phase modulator based on an intense XUV laser beam propagating through an optically thick resonant target, introducing dispersion profile variations around the resonance both perpendicular to and along the laser propagation direction. The resulting dipole radiation gets spectrally reshaped and becomes more divergent as compared to the original beam in the far field. As an experimental demonstration, the intense-XUV–induced double-peak off-axis structure in the far-field spectrum obtained at the Free-Electron Laser in Hamburg (FLASH) shows indications of the underlying XUV-driven Rabi dynamics and resonant pulse propagation effects. The presented work highlights a ubiquitous phenomenon occurring when an intense laser beam passes through a resonant medium.

He, Yu [Max-Planck-Institut für Kernphysik, Heidel↗

∆ E /∆ E Measurements of Energetic Ions Using CVD Diamond Detectors

Experimental and computational results of a Δ E /Δ E diamond detection system are presented. The Δ E /Δ E detection system was evaluated using energetic proton and iron beams striking thick polyethylene targets at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). The measured data for diamond sensor A show good agreement with the Geant4 simulation. In addition, simulations have demonstrated the ability to identify hydrogen isotopes using a diamond detection system.

Alghamdi, Ahmed↗

Laser-driven high-resolution MeV x-ray tomography

The need for high-resolution MeV x-ray tomography to observe the three-dimensional structure of dense, large-sized objects is rapidly increasing for the non-destructive evaluation of critical additively manufactured parts, national security, and other applications. We report a demonstration of high-resolution MeV computed tomography of a dense, large object with a laser-driven x-ray source. A record detector-limited MeV radiograph resolution of < 200 µm as determined with the Bennett approximation of the point spread function was achieved by irradiating millimeter-thick tungsten targets with 300 TW femtosecond laser pulses at a 0.5 Hz repetition rate. A tungsten alloy step wedge spectrometer indicates that the peak of the x-ray emission is between 1 and 2 MeV, with an endpoint energy of 19 MeV. To illustrate the radiographic imaging capability of the system, a tomographic reconstruction of a nickel superalloy turbine blade ( maximum $ρr$ = 139 g/cm 2 ) with sub-millimeter resolution was performed using 2160 individual radiographs. The small x-ray source size opens the prospect of extremely high-resolution tomographs of large, dense objects. This laser-driven approach has major advantages for non-destructive evaluation.

47 OTHER INSTRUMENTATION↗

MuSR Beam Line Design Studies

When a substance is implanted with positive muons the precession of their magnetic moments can be used to sample the magnetic properties of the material. The information obtained is complementary to that from NMR, ESR, and neutron scattering. To date, only four user facilities exist in the world but none in the US. We explore the possibility of using the AGS complex at BNL for a μSR facility for the production of positive surface muons. With an incident proton intensity of 10 14 protons per second hitting a 200 mm long 0.5 mm thick graphite target, our preliminary design of the beam line could produce low momentum surface muons (24–30 MeV/c) with a flux of 0.9 MHz/cm 2 for experiments.

43 PARTICLE ACCELERATORS↗

Modeling Dynamic Fracture of Cryogenic Pellets

This work is part of an investigation with the long-range objective of predicting the size distribution function and velocity dispersion of shattered pellet fragments after a large cryogenic pellet impacts a solid surface at high velocity. The study is vitally important for the shattered pellet injection (SPI) technique, one of the leading technologies being implemented at ORNL for the mitigation of disruption damage on current tokamaks and ITER. The report contains three parts that are somewhat interwoven. In Part I we formulated a self-similar model for the expansion dynamics and velocity dispersion of the debris cloud following pellet impact against a thick (rigid) target plate. Also presented in Part I is an analytical fracture model that predicts the nominal or mean size of the fragments in the debris cloud and agrees well with known SPI data. The aim of Part II is to gain an understanding of the pellet fracturing process when a pellet is shattered inside a miter tube with a sharp bend. Because miter tubes have a thin stainless steel (SS) wall a permanent deformation (dishing) of the wall is produced at the site of the impact. A review of the literature indicates that most projectile impact on thin plates are those for which the target is deformed and the projectile is perfectly rigid. Such impacts result in “projectile embedding” where the projectile speed is reduced to zero during the interaction so that all the kinetic energy (KE) of the projectile goes into the energy stored in plastic deformation. Much of the literature deals with perforation of the target. The problem here is quite different; the softer pellet easily undergoes complete material failure causing only a small transfer of KE to stored energy of wall deformation. For the real miter tube, we derived a strain energy function for the wall deflection using a non-linear (plastic) stress-strain relation for 304 SS. Using a dishing profile identical to the linear Kirchkoff-Love profile (for lack of a rigorously derived profile) we derived the strain energy associated with the deflection and applied a virtual work principle to find a relationship between the impact (load) pressure to the measured wall deflection depth. The inferred impact pressure was in good agreement with the expected pressure for oblique cryogenic pellet impacts where the pellet shear stress causing cleavage fracture is well above the yield stress for pure shear. The section is concluded with additional discussion on how this wall deformation data lends further support to the analytical fracture model presented in Part I. In Part III we present three different size distribution models. A summary, with a few brief suggestions for a follow on study, is provided at the end of this report.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shielding Thickness Recommendations for an Activated Target Segment Vertical Stave

This analysis examines the shielding requirements needed to plan maintenance and handling operations of the target segment assembly vertical stave. It provides the analyses and results that fulfill the requirements of Task Order TO-150. The vertical stave is a stainless-steel welded assembly that carries cooling water to and from the target block. In this report, we characterize the dose rates and shielding requirements for the vertical stave only, i.e., separated from the target block. Shielding and dose rates for the target block only have been calculated in response to TO-008.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ultra-rapid, physics-based development pathway for reactor-relevant RF antenna materials

This paper presents a rapid, atomistically-informed, experimental development pathway for fusion reactor-relevant radio frequency (RF) antenna materials in the Cu-Cr-(Nb,Al,Zr) composition system, with the goal of improving upon GRCop-84. RF antennas in a tokamak fusion reactor will face a unique set of challenges as both structural and functional materials. The desired material must simultaneously achieve and maintain high electrical conductivity, high strength, high thermal conductivity, resist high temperatures, possess low nuclear activation, and incur low damage due to neutron bombardment. The GRCop-84 alloy serves as a starting point for iterative improvement, with the desire to reduce or eliminate Nb from the material to minimize nuclear activation. The rapid development pathway makes use of a multi-target combinatorial thick film sputtering process to produce full ternary phase diagrams on a Si wafer substrate. Transient grating spectroscopy (TGS), a laser-ultrasonic method, will determine spatially-varying thermo-elastic properties, while four terminal electrical conductivity measurements will map out the best per- forming regions of the sample for in-depth study at larger length scales. High energy proton and self-ion irradiation emulates the effects of neutron damage on the thermal/electric properties. With rapid turnaround time (∼days) in terms of mapping radiation damage-induced material property changes in the full ternary system, these techniques allow rapid iteration towards an optimal material, testing hundreds of nearby compositions in the time it took to test one. Focused testing of larger, single composition samples (produced in an arc furnace or by laser sintering) provides data on structural and high power RF properties, and validates our thick-film based workflow.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The formation of excited atoms during charge exchange between hydrogen ions and alkali atoms

The charge exchange cross sections for protons and various alkali atoms are calculated using the classical approximation of Gryzinski. It is assumed that the hydrogen atoms resulting from charge exchange exist in all possible excited states. Charge transfer collisions between protons and potassium as well as protons and sodium atoms are studied. The energy range investigated is between 4 and 30 keV. The theoretical calculations of the capture cross section and the cross section for the creation of metastable 2S hydrogen are compared to experimental values. Good quantitative agreement is found for the capture cross section but only qualitative agreement for the metastable cross section. Analysis of the Lyman alpha window in molecular oxygen suggests that measured values of the metastable cross section may be in error. Thick alkali target data are also presented. This allows the determination of the total electron loss cross section. Finally, some work was done with H2(+).

Nieman, R. A.↗

A two-parameter scintillation spectrometer system for measurement of secondary proton, deuteron, and triton distributions from materials under 558-MeV-proton irradiation

A two-parameter scintillation spectrometer system developed and used to obtain proton, deuteron, and triton double differential cross sections from materials under 558-MeV-proton irradiation is described. The system measures both the time of flight of secondary particles over a 488-cm flight path and the energy deposited in a scintillator, 12.7 cm in diameter and 30.48 cm long. The time resolution of the system is 0.39 nsec. The calculated energy resolution based on this time resolution varies with energy from 1.6 precent to 7.75 percent for 50- and 558-MeV protons. Various systematic and statistical errors are evaluated, and the double differential cross sections for secondary proton and deutron production at 20 deg from a 2.35 g/sq cm thick beryllium target are shown as an example of the results obtainable with this system. The uncertainly in the cross sections for secondary protons varies with particle energy from approximately + or - 9 percent at 50 MeV to approximately + or - 11 percent at 558 MeV.

Beck, S. M.↗

A preliminary area survey of neutron radiation levels associated with the NASA variable energy cyclotron horizontal neutron delivery system

The 25 MeV deuteron beam from the NASA variable energy cyclotron incident on a thick beryllium target will deliver a tissue neutron dose rate of 2.14 rad micron A-min at a source to skin distance of 125 cm. A neutron survey of the existing hallways with various shielding configurations made during operating of the horizontal neutron delivery system indicates that minimal amounts of additional neutron shielding material are required to provide a low level radiation environment within a self-contained neutron therapy control station. Measurements also indicate that the primary neutron distribution delivered by a planned vertical delivery system will be minimally perturbed by neutrons backscattered from the floor.

Roberts, W. K.↗