At least 595 records · Page 33

High-accuracy global time and frequency transfer with a space-borne hydrogen maser clock

A proposed system for high-accuracy global time and frequency transfer using a hydrogen maser clock in a space vehicle is discussed. Direct frequency transfer with a accuracy of 10 to the minus 14th power and time transfer with an estimated accuracy of 1 nsec are provided by a 3-link microwave system. A short pulse laser system is included for subnanosecond time transfer and system calibration. The results of studies including operational aspects, error sources, data flow, system configuration, and implementation requirements for an initial demonstration experiment using the Space Shuttle are discussed.

Decher, R.↗

Calibrated intercepts for solar radiometers used in remote sensor calibration

Calibrated solar radiometer intercepts allow spectral optical depths to be determined for days with intermittently clear skies. This is of particular importance on satellite sensor calibration days that are cloudy except at the time of image acquisition. This paper describes the calibration of four solar radiometers using the Langley-Bouguer technique for data collected on days with a clear, stable atmosphere. Intercepts are determined with an uncertainty of less than six percent, corresponding to a maximum uncertainty of 0.06 in optical depth. The spread of voltage intercepts calculated in this process is carried through three methods of radiometric calibration of satellite sensors to yield an uncertainty in radiance at the top of the atmosphere of less than one percent associated with the uncertainty in solar radiometer intercepts for a range of ground reflectances.

Gellman, David I.↗

Development of In-Fiber Reflective Bragg Gratings as Shear Stress Monitors in Aerodynamic Facilities

Bragg gratings centered at nominal wavelengths of 1290 nm and 1300 run were inscribed in a 9/125 microns germano-silicate optical fiber, using continuous wave frequency doubled Ar+ laser radiation at 244 nm. Such gratings have been used extensively as temperature and strain monitors in smart structures. They have, however, never been used for measuring aerodynamic shear stresses. As a test of their sensitivity as shear stress monitors, a Bragg fiber attached to a metal plate was subjected to laminar flows in a glass pipe. An easily measurable large flow-induced wavelength shift (Delta Lambda(sub B)) was observed in the Bragg reflected wavelength. Thereafter, the grating was calibrated by making one time, simultaneous measurements of Delta Lambda(sub B) and the coefficient of skin friction (C(sub f)) with a skin friction balance, as a function of flow rates in a subsonic wind tunnel. Onset of fan-induced transition in the tunnel flow provided a unique flow rate for correlating Delta Lambda(sub B) and (C(sub f) values needed for computing effective modulus of rigidity (N(sub eff)) of the fiber attached to the metal plate. This value Of N(sub eff) is expected to remain constant throughout the elastic stress range expected during the Bragg grating aerodynamic tests. It has been used for calculating the value of Cf at various tunnel speeds, on the basis of measured values of Bragg wavelength shifts at those speeds.

Parmar, Devendra S.↗

Comments on SEE: Comparative Advantages and and Experimental Consequences

The Satellite Energy Exchange experiment measures the periodic, near-miss encounters between a sheppard satellite and a small test body (satellite) in approximately the same orbit about a primary. Several important experimental requirements have been chosen to enhance capabilities: (a) The satellite be flown in a sun-synchronous orbit at an altitude of about 1350 Km, (b) Passive temperature system stabilized by spacecraft axial rotation with sunshade baffles at the end of the spacecraft, (c) Test bodies with different material composition be available for experiments, (d) The containment spacecraft fly about the sheppard mass in a zero-g environment whereas the test bodies, experience average zero-g environment over an orbital period, (e) Primary attitude and station-keeping uses magnetic field alignment plus micro-Newton thrusters such as Field Emission Electric Propulsion, and (f) Very low power (nW) laser tracking systems minimize impulse delivered to test bodies. With the above conditions, SEE has the capabilities: (1) Long duration (several years life-time) flight experiment (2) Long-term, active (with historical time record), self-calibration of satellite mass distribution (capsule geodesy) over lifetime of the spacecraft. (3) Novel passive thermal stabilization systems designed to attain cryogenic temperatures around 78K. (4) Novel spacecraft stabilization systems. (5) Ability to measure G to 1 part in 10(exp 6-7) depending on ultimate duration of experiment. (6) Ability to place limits on both temporal and spacial variations on G. (7) Ability to set experimental limits on the Post Newtonian parameters (PPN) alpha(2) and zeta(2). (8) Ability to measure (or place limits on) the non Einsteinian eccentricity of the Earth-Sun system (and the parameter alpha(1)) for long duration flight. (9) Ability to measure Delta((dot)-G)/G to 1 part in 10(exp 12-13). The MiniSTEP, competes in a limited way with Project SEE. It is designed to improve the measurement of the equivalence principle by seven orders of magnitude using active, low temperature (1.8 K) cooling for SQUID based, differential superconducting circuits. The experiment consists of a small cylinder concentrically located within a larger cylinder at its null gravitational point. The satellite is operated in zero-g mode using four differential accelerometers consisting to two test bodies of different material composition. The SQUIDS are needed to measure test body motion to precisions of 10(exp -18) over a four orbit period. The entire satellite moves in a very precise zero-g mode since the accelerometers are rigidly attached to the satellite. This limits the experiment to an approximately six month due to limitations on helium storage used in cryogenic cooling and thrust control to maintain the zero-g operation.

Smalley, Larry L.↗

Submillimeter Wave Astronomy Satellite (SWAS) Launch and Early Orbit Support Experiences

The Submillimeter Wave Astronomy Satellite (SWAS) was successfully launched on December 6, 1998 at 00:58 UTC. The two year mission is the fourth in the series of Small Explorer (SMEX) missions. SWAS is dedicated to the study of star formation and interstellar chemistry. SWAS was injected into a 635 km by 650 km orbit with an inclination of nearly 70 deg by an Orbital Sciences Corporation Pegasus XL launch vehicle. The Flight Dynamics attitude and navigation teams supported all phases of the early mission. This support included orbit determination, attitude determination, real-time monitoring, and sensor calibration. This paper reports the main results and lessons learned concerning navigation, support software, star tracker performance, magnetometer and gyroscope calibrations, and anomaly resolution. This includes information on spacecraft tip-off rates, first-day navigation problems, target acquisition anomalies, star tracker anomalies, and significant sensor improvements due to calibration efforts.

Kirschner, S.↗

Submillimeter Wave Astronomy Satellite (SWAS) Launch and Early Orbit Support Experiences

The Submillimeter Wave Astronomy Satellite (SWAS) was successfully launched on December 6, 1998 at 00:58 UTC. The two year mission is the fourth in the series of Small Explorer (SMEX) missions. SWAS is dedicated to the study of star formation and interstellar chemistry. SWAS was injected into a 635 km by 650 km orbit with an inclination of nearly 70 deg by an Orbital Sciences Corporation Pegasus XL launch vehicle. The Flight Dynamics attitude and navigation teams supported all phases of the early mission. This support included orbit determination, attitude determination, real-time monitoring, and sensor calibration. This paper reports the main results and lessons learned concerning navigation, support software, star tracker performance, magnetometer and gyroscope calibrations, and anomaly resolution. This includes information on spacecraft tip-off rates, first-day navigation problems, target acquisition anomalies, star tracker anomalies, and significant sensor improvements due to calibration efforts.

Kirschner, S.↗

Using the World Primary Standard Dobson Spectrometer to Monitor the Stability of a Multi-Instrument Satellite Ozone Dataset

NASA is creating a long term satellite ozone time series by combining data from multiple instruments: Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) (1978 - 1993), Meteor 3 TOMS (1991 - 1994), Earth Probe TOMS (1996 - present), Nimbus 7 SB-JV (1978 - 1990), NOAA-9 Solar Backscatter UV Spectrometer (SBUV/2) (1984 - 1997), NOAA-11 SBUV/2 (1989 - 1994), and NOAA-14 SBUV/2 (1995 - present). The stability of individual data sets and possible instrument-to-instrument differences are best checked by comparison with ground-based measurements. We have examined the time dependence of the calibrations of these instruments by comparing satellite derived ozone with that measured by the world primary standard Dobson spectrometer No. 83. This instrument has been maintained since 1962 as a standard for total ozone to an uncertainty of plus or minus 0.5%. Measurements of AD pair ozone made with instrument No. 83 at Mauna Loa observatory most summers since 1979 were compared with coincident TOMS and SBUV(/2) ozone measurements. The comparison shows that the various instruments were stable relative to instrument No. 83 to within about plus or minus 1%, but that there are instrument-to-instrument biases of as much as 3%. Earth Probe TOMS, for example, is 1% to 2% high relative to Nimbus 7 TOMS when the world standard instrument is used as a transfer standard. Similar results are seen when comparisons are made with an ensemble of 41 Dobson stations throughout the world, demonstrating that the ensemble as a whole is stable despite the fact that many instruments within the ensemble have clear calibration changes.

McPeters, R.D.↗

Dynamics of the Molten Contact Line

The purpose of this program is to develop a basic understanding of how a molten material front spreads over a solid that is below its melting point, arrests, and freezes. Our hope is that the work will contribute toward a scientific knowledge base for certain new applications involving molten droplet deposition, including the "printing" of arbitrary three-dimensional objects by precise deposition of individual molten microdrops that solidify after impact. Little information is available at this time on the capillarity-driven motion and arrest of molten contact line regions. Schiaffino and Sonin investigated the arrest of the contact line of a molten microcrystalline wax spreading over a subcooled solid "target" of the same material. They found that contact line arrest takes place at an apparent liquid contact angle that depends primarily on the Stefan number S=c(T(sub f) -T(sub t)/L based on the temperature difference between the fusion point and the target temperature, and proposed that contact line arrest occurs when the liquid's dynamic contact angle approaches the angle of attack of the solidification front just behind the contact line. They also showed, however, that the conventional continuum equations and boundary conditions have no meaningful solution for this angle. The solidification front angle is determined by the heat flux just behind the contact line, and the heat flux is singular at that point. By comparing experiments with numerical computations, Schiaffino and Sonin estimated that the conventional solidification model must break down within a distance of order 0.1 - 1 microns of the contact line. The physical mechanism for this breakdown is as yet undetermined, and no first-principles theory exists for the contact angle at arrest. Schiaffino and Sonin also presented a framework for understanding how to moderate Weber number molten droplet deposition in terms of similarity laws and experimentation. The study is based on experiments with three molten materials- molten wax on solid wax, water on ice, and mercury on frozen mercury- which between them span a considerable range of the deposition/solidification similarity parameters. Correlations are obtained for the spreading velocity, spreading time scales, the spreading factor (i.e. ratio of deposited drop's final footprint radius and the drop's initial radius), post-spreading liquid oscillation amplitudes and time scales, and bulk solidification time scales. Duthaler carried out an experimental and theoretical investigation of the relationship between the liquid's apparent contact angle and the Capillary number Ca=mu U/sigma based on contact line speed, for molten materials spreading over subcooled solids. This relationship is required for modeling of melt spreading. We have adapted Voinov's methodology to the molten contact line and formulated a theoretical model for the Ca vs. contact angle relationship, based Schiaffino and Sonin#s (1997a,b) wedge-like solidification front model. With the solidification front angle taken from Schiaffino and Sonin, the model is in good agreement with the experimental results for Ca vs. contact angle. Duthaler also extended the experimental investigation of droplet deposition and contact line freezing to more materials, including solder on glass, solder on solder, water on ice, and molten microcrystalline wax on wax. The latter also included tests on inclined targets. Deposition tests have also been done with molten octacosane (C28H58) on various targets. An important objective of our program has been the development of micron-scale sensors for measuring the transient temperature at a point on the substrate surface as a molten contact line moves over it. The expectation is that this temperature history will yield a better understanding of the thermal process in the contact line region. The sensors are of the thermistor type, either 2.5 microns or 1.5 microns square, microfabricated with silicon-based technology on either pure silicon or amorphous silicon dioxide chips. Each chip has 32 sensors distributed on its surface in arrays. The time response is better than 10 ms. At the time of writing, sensor calibration is in progress. Results on thermal transients during contact line passage will be discussed at the conference. While we expect that the data will provide information on the near-contact-line heat transfer process, we also foresee possible problems. First, the spatial resolution of the sensors may be insufficient to resolve the near-contact-line region. Second, the sensors protrude about 0.5 microns above the substrate surface, and may affect the contact line motion. Third, a sensor's temperature history depends on both the heat flux distribution into it from the fusion front and the thermal properties of the substrate below it and the solidified melt between it and the fusion front. The heat flux distribution in the contact line region must therefore be unfolded from computations of the overall system's transient thermal response.

Sonin, Ain A.↗

Progress on the Cluster Mission

Prof M. G. Kivelson and Dr. K. K. Khurana (UCLA (University of California, Los Angeles)) are co-investigators on the Cluster Magnetometer Consortium (CMC) that provided the fluxgate magnetometers and associated mission support for the Cluster Mission. The CMC designated UCLA as the site with primary responsibility for the inter-calibration of data from the four spacecraft and the production of fully corrected data critical to achieving the mission objectives. UCLA will also participate in the analysis and interpretation of the data. The UCLA group here reports its excellent progress in developing fully intra-calibrated data for large portions of the mission and an excellent start in developing inter-calibrated data for selected time intervals, especially extended intervals in August, 2001 on which a workshop held at ESTEC in March, 2002 focused. In addition, some scientific investigations were initiated and results were reported at meetings.

Kivelson, Margaret↗

Simulating Nonlinear Deformations of Solar Sail Membranes Using Explicit Time Integration

In this study, the explicit time integration method is employed to predict deformation of highly flexible solar sail structural components. The nonlinear static analysis of a highly flexible ribbon structure is presented to demonstrate the need for having the explicit time integration method in the analysis toolbox for solar sail. Static analyses of the ribbon structure produce ambiquous results whereas the explicit time integration method determines the correct results. Extensive benchmarking examples are also presented to build confidence in the use of the explicit method. Previously determined nonlinear wrinkling deformations of solar sail membranes are found by the explicit method. As the explicit method is known to often require more computational time than nonlinear static methods, a study on mass scaling was also conducted. The computational times are reported for the nonlinear static and explicit time integration solutions to calibrate the advantage of using mass scaling for these problems.

Wang, John T.↗

Innovative Technology Transfer Partnerships

The National Aeronautics and Space Administration (NASA) seeks to license its Advanced Tire and Strut Pressure Monitor (TSPM) technology. The TSPM is a handheld system to accurately measure tire and strut pressure and temperature over a wide temperature range (20 to 120 OF), as well as improve personnel safety. Sensor accuracy, electronics design, and a simple user interface allow operators quick, easy access to required measurements. The handheld electronics, powered by 12-VAC or by 9-VDC batteries, provide the user with an easy-to-read visual display of pressure/temperature or the streaming of pressure/temperature data via an RS-232 interface. When connected to a laptop computer, this new measurement system can provide users with automated data recording and trending, eliminating the chance for data hand-recording errors. In addition, calibration software allows for calibration data to be automatically utilized for the generation of new data conversion equations, simplifying the calibration processes that are so critical to reliable measurements. The design places a high-accuracy pressure sensor (also used as a temperature sensor) as close to the tire or strut measurement location as possible, allowing the user to make accurate measurements rapidly, minimizing the amount of high-pressure volumes, and allowing reasonable distance between the tire or strut and the operator. The pressure sensor attaches directly to the pressure supply/relief valve on the tire and/or strut, with necessary electronics contained in the handheld enclosure. A software algorithm ensures high accuracy of the device over the wide temperature range. Using the pressure sensor as a temperature sensor permits measurement of the actual temperature of the pressurized gas. This device can be adapted to create a portable calibration standard that does not require thermal conditioning. This allows accurate pressure measurements without disturbing the gas temperature. In-place calibration can save considerable time and money and is suitable in many process applications throughout industry.

Kohler, Jeff↗

NASA Tech Briefs, February 2012

This issue contains the following briefs: (1) Optical Comb from a Whispering Gallery Mode Resonator for Spectroscopy and Astronomy Instruments Calibration (2) Real-Time Flight Envelope Monitoring System (3) Nemesis Autonomous Test System (4) Mirror Metrology Using Nano-Probe Supports (5) Automated Lab-on-a-Chip Electrophoresis System (6) Techniques for Down-Sampling a Measured Surface Height Map for Model Validation (7) Multi-Component, Multi-Point Interferometric Rayleigh/Mie Doppler Velocimeter (8) Frequency to Voltage Converter Analog Front-End Prototype (9) Dust-Tolerant Intelligent Electrical Connection System (10) Gigabit Ethernet Asynchronous Clock Compensation FIFO (11) High-Speed, Multi-Channel Serial ADC LVDS Interface for Xilinx Virtex-5 FPGA (12) Glovebox for GeoLab Subsystem in HDU1-PEM (13) Modified Process Reduces Porosity when Soldering in Reduced Gravity Environments (14) Use of Functionalized Carbon Nanotubes for Covalent Attachment of Nanotubes to Silicon (15) Flexible Plug Repair for Shuttle Wing Leading Edge (16) Three Dimensionally Interlinked, Dense, Solid Form of Single-Walled CNT Ropes (17) Axel Robotic Platform for Crater and Extreme Terrain Exploration (18) Site Tamper and Material Plow Tool - STAMP (19) Magnetic Interface for Segmented Mirror Assembly (20) Transpiration-Cooled Spacecraft-Insulation-Repair Fasteners (21) Fluorescence-Based Sensor for Monitoring Activation of Lunar Dust (22) Aperture Ion Source (23) Virtual Ultrasound Guidance for Inexperienced Operators (24) Model-Based Fault Diagnosis: Performing Root Cause and Impact Analyses in Real Time (25) Interactive Schematic Integration Within the Propellant System Modeling Environment (26) Magnetic and Electric Field Polarizations of Oblique Magnetospheric Chorus Waves (27) Variable Sampling Mapping.

Source record↗

Temporal Gain Correction for X-Ray Calorimeter Spectrometers

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-HSXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

X-ray detector X-ray spectrometer X-ray calorimete↗

Analysis of the Electronic Crosstalk Effect in Terra MODIS Long-Wave Infrared Photovoltaic Bands Using Lunar Images

The Moderate Resolution Imaging Spectroradiometer (MODIS) is one of the key sensors among the suite of remote sensing instruments on board the Earth Observing System Terra and Aqua spacecrafts. For each MODIS spectral band, the sensor degradation has been measured using a set of on-board calibrators. MODIS also uses lunar observations from nearly monthly spacecraft maneuvers, which bring the Moon into view through the space-view port, helping to characterize the scan mirror degradation at a different angles of incidence. Throughout the Terra mission, contamination of the long-wave infrared photovoltaic band (LWIR PV, bands 27-30) signals has been observed in the form of electronic crosstalk, where signal from each of the detectors among the LWIR PV bands can leak to the other detectors, producing a false signal contribution. This contamination has had a noticeable effect on the MODIS science products since 2010 for band 27, and since 2012 for bands 28 and 29. Images of the Moon have been used effectively for determining the contaminating bands, and have also been used to derive correction coefficients for the crosstalk contamination. In this paper, we introduce an updated technique for characterizing the crosstalk contamination among the LWIR PV bands using data from lunar calibration events. This approach takes into account both the in-band and out-of-band contribution to the signal contamination for each detector in bands 27-30, which is not considered in previous works. The crosstalk coefficients can be derived for each lunar calibration event, providing the time dependence of the crosstalk contamination. Application of these coefficients to Earth-view image data results in a significant reduction in image contamination and a correction of the scene radiance for bands 27- 30. Also, this correction shows a significant improvement to certain threshold tests in the MODIS Level-2 Cloud Mask. In this paper, we will detail the methodology used to identify and correct the crosstalk contamination for the LWIR PV bands in Terra MODIS. The derived time-dependent crosstalk coefficients will also be discussed. Finally, the impact of the correction on the downstream data products will be analyzed.

Wilson, Truman↗

Mapping of Spacecraft Atmosphere Monitor Signal to Major Constituent Abundances

The Spacecraft Atmosphere Monitor (S.A.M.) follows the JPL’s commitment to introduce and develop next-generation instrumentation concepts for sensing the air quality on manned space flights via continuous sampling, measuring, and reporting in 2s intervals on all gaseous pollutants. The S.A.M. will have two modes of operation: the Major Constituent Analysis (MCA) mode and the Trace Gas Analysis (TGA) mode. The MCA mode will report on molecular analytes such as CH4, H2O, N2, O2, Ar, and CO2 while the TGA mode will acquire minute amounts of volatile organic compounds. Both modes assess the composition of the ambient air with twenty full mass spectra per second giving rise to a substantial amount of data to be processed by a set of small footprint software stacks hosted by an on-board computer. Mass spectra will be accumulated as the number of counts recorded in a given mass-to-charge channel and converted into the absolute abundances of detected species using an efficient algorithm. The decomposition algorithm contains four units: peak identification, mass calibration, background and dead time correction, and an abundance analysis unit. The abundance analysis module identifies target species through their characteristic fragmentation patterns in the presence of molecular isobars, such as CO and N2. For example, in order to identify N2 analyte, the code will simultaneously monitor abundance ratios of the 14, 28 and 29 Th signals and will adapt to any instability caused by a decrease in ambient pressure or changes in humidity. This requirement becomes critical for instruments designed to monitor the near real-time quality of cabin air and promptly provide accurate feedbacks.

Nikolic, D.↗

A Multidisciplinary Modeling Approach of Plant Gas Exchange in Reduced Gravity Environments

In-situ food production is a necessary step for human exploration of the solar system and requires a deep understanding of plant growth in reduced gravity environments. In particular, the lack of buoyancy-driven convection changes the gas exchange at the leaf surface, which decreases photosynthesis and transpiration rates, and ultimately biomass production. To understand the intricate relations between physical, chemical, and biochemical processes, the following methodology combines the development of a mechanistic model of plant growth in reduced gravity environments, computational fluid dynamics (CFD) simulations, and experiments in different time frames.The model presented here is a coupled mass and energy balance using the single round leaf assumption, including gravity as an entry parameter, and the leaf surface temperature as an output variable. Measures of the leaf surface temperature using infra-red cameras allow for a computation of the transpiration rate. This approach was followed to design a parabolic flight experiment, which performed 7 flights, and enabled data collection for model validation in different gravity and ventilation settings on a short time frame. Current measures of carbon assimilation and transpiration rate at the leaf and canopy level using an infra-red gas analyzer (Li-6800) in 1g lab conditions on several species will enable a validation on longer time frames and further calibration of the model. CFD studies both on the parabolic flight and on the lab experimental set-up allow the precise assessment of ventilation above the canopy and plants' leaves.Ultimately, this work will provide recommendations for the design of future plant growth hardware, especially on the lowest adequate ventilation for optimal plant growth in reduced gravity environments, as well as assessing biomass and oxygen production rates on planetary surfaces and space stations. This work was funded by CNES, CNRS, Clermont Auvergne Metropole, and NASA Space Biology through NASA postdoctoral program / USRA.

Poulet, Lucie↗

Utilizing Libya-4 to Intercalibrate Overlapping Sensors in the Same Sun-Synchronous Orbit

The NASA CERES observed SW and LW broadband fluxes are utilized by the climate community for monitoring the Earth’s energy imbalance and for climate model validation. The SNPP and NOAA20 CERES instruments and associated VIIRS imagers were launched into the same 1:30 PM mean local time sun-sun-synchronous orbits as well as the future NOAA22 Libera broadband instrument and VIIRS imager. The overlapping sensor records need to be intercalibrated to enable consistent broadband fluxes and imager cloud retrievals. The overlapping satellites are typically placed a half an orbit apart, thus preventing any simultaneous nadir overpass (SNO) events required for time-matched inter-calibration strategies. A Pseudo Invariant Calibration Site (PICS), such as Libya-4, can provide overlapping sensor radiometric scaling factors without the use of SNOs. The clear-sky Libya-4 observed radiances were characterized both spectrally and angularly and corrected for atmospheric effects. The Libya-4 natural variability was found to be consistent across the CERES and VIIRS records. This fact reveals that the sensor onboard calibration anomalies are smaller than the Libya-4 natural variability. By mitigating the Libya-4 natural variability will reduce the radiometric scaling factor uncertainty needed to provide both broadband flux and cloud retrieval continuity across the overlapping sensor records.

D R Doelling↗