Synthesis of Submillimeter Radiation for Spectroscopy

The frequency-multiplier submillimeter spectrometer (FMSS) is a laboratory apparatus for far-infrared molecular spectroscopy, embodying several advances over prior such apparatuses. The most innovative part of the FMSS is a source of monochromatic submillimeter- wavelength radiation that can be tuned over a wide frequency range, as needed for trace gas analyses and molecular- structure studies for which such apparatuses are typically used. The radiation source features a modular design and is built mostly from commercially available components. It includes a computer-controlled radio-frequency synthesizer, amplifiers, and frequency multipliers of a type heretofore used in local oscillators for heterodyne far-infrared receivers. In conjunction with the rest of the apparatus, this source makes it possible to perform measurements over large portions of the submillimeter-wavelength spectrum with resolution, accuracy, and sensitivity greater than those achievable in Fourier-transform infrared spectroscopy. In comparison with prior laboratory submillimeter- wavelength radiation sources, this source is much lighter in weight, less cumbersome, less power-hungry, and capable of sustained operation with less intervention by laboratory personnel. Also, unlike some prior submillimeter-wavelength sources, this source does not require a high-voltage power source. As shown in more detail in the figure, the radiation source includes a sweep frequency synthesizer connected to an external waveform generator, the output of which is used as a reference signal. The synthesizer is computer-controlled through a standard general-purpose interface bus (GPIB) and is operated in phase-locked continuous- wave mode for all measurements. The synthesizer output ranges in frequency from 11 to 18 GHz. For suppression of frequency spurs and harmonics, the output of the frequency synthesizer is fed through a tunable yttrium iron garnet (YIG) filter, which is swept in frequency simultaneously with the frequency synthesizer.

Maiwald, Frank↗

Design study of a 0.4 THz 100 kW pulsed gyrotron

We present a status of development of a 0.4 THz, 100 kW pulsed gyrotron at UNIST 0.4 THz, 100 kW gyrotron is currently under design for a remote radioactive material detection. A magnetic injection gun (MIG) is used for the electron gun with a beam voltage of 70 kV and beam current of 10 A with a pulse duration of 10 usec. A second harmonic cavity for the gyrotron interaction is considered for the high power THz gyrotron. Numerical optimization of the electron gun design and the cavity is performed in the study. In this paper, we briefly report the design study of the gyrotron. (author)

43 PARTICLE ACCELERATORS↗

Design, construction, system integration, and test results of the 1 MW CW RF system for the e-gun cavity in the energy recovery LINAC at Brookhaven National Laboratory

Brookhaven's ERL (Energy Recovery LINAC) requires a 1 MW CW RF system for the superconducting electron gun cavity. The system consists primarily of a klystron tube, transmitter, and High-Voltage Power Supply (HVPS). The 703.75 MHz klystron made by CPl, Inc. provides RF power of 1MW CW with efficiency of 65%. It has a single output window, diode-type electron gun, and collector capable of dissipating the entire beam power. It was fully factory tested including 24-hour heat run at 1.1 MW CWo The solid state HVPS designed by Continental Electronics provides up to 100 kV at low ripple and 2.1 MW CW with over 95% efficiency. With minimal stored energy and a fast shut-down mode no crowbar circuit is needed. Continental 's transmitter includes PLC based user interface and monitoring, RF pre-amplifier, magnet and Vac-Ion pump supplies, cooling water instrumentation, and integral safety interlock system. BNL installed the klystron, HVPS, and transmitter along with other items, such as circulator, water load, and waveguide components. The collaboration of BNL, CPI, and Continental in the design, installation, and testing was essential to the successful operation of the 1MW system.

43 PARTICLE ACCELERATORS↗

Kondo effect and its destruction in heterobilayer transition metal dichalcogenides

Moiré structures, along with line-graph-based d -electron systems, represent a setting to realize flat bands. One form of the associated strong correlation physics is the Kondo effect. Here, we address the recently observed Kondo-driven heavy fermion state and its destruction in AB-stacked hetero-bilayer transition metal dichalcogenides, which can be controlled by the gate voltages. By studying an effective interacting Hamiltonian using the slave spin approach, we obtained a phase diagram with the total filling factor and the displacement field strength as the tunable parameters. In an extended range of the tunable displacement field, our numerical results show that the relative filling of the d orbital, which is associated with the highest moiré band from the MoTe 2 layer, is enforced to be ν d ≈ 1 by the interaction. This agrees with the experimental observation. We also argue that the observed high coherence temperature scale could be explained by the non-negligible bandwidth of the d orbital. Our results set the stage to address the amplified quantum fluctuations that the Kondo effect may produce in these structures and new regimes that the systems open up for Kondo-destruction quantum criticality. Published by the American Physical Society 2024

Xie, Fang (ORCID:000000021327767X)↗

Optimization of operation of a three-electrode gyrotron with the use of a flow-type calorimeter

Results are presented for measurements of microwave power of the Borets-75/0.8 gyrotron with recovery of residual electron energy, which were performed by a flow-type calorimeter. This gyrotron is a part of the ECR plasma heating complex put into operation in 2010 at the L-2M stellarator. The new calorimeter is capable of measuring microwave power up to 0.5 MW. Monitoring of the microwave power makes it possible to control the parameters of the gyrotron power supply unit (its voltage and current) and the magnetic field of the cryomagnet in order to optimize the gyrotron operation and arrive at maximum efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-channel capacitive probe for electrostatic fluctuation measurement in the Madison Symmetric Torus reversed field pinch

A 40-channel capacitive probe has been developed to measure the electrostatic fluctuations associated with the tearing modes deep into Madison Symmetric Torus (MST) reversed field pinch plasma. The capacitive probe measures the ac component of the plasma potential via the voltage induced on stainless steel electrodes capacitively coupled with the plasma through a thin annular layer of boron nitride (BN) dielectric (also serves as the particle shield). When bombarded by the plasma electrons, BN provides a sufficiently large secondary electron emission for the induced voltage to be very close to the plasma potential. The probe consists of four stalks each with ten cylindrical capacitors that are radially separated by 1.5 cm. The four stalks are arranged on a 1.3 cm square grid so that at each radial position, there are four electrodes forming a square grid. Every two adjacent radial sets of four electrodes form a cube. The fluctuating electric field can be calculated by the gradient of the plasma potential fluctuations at the eight corners of the cube. The probe can be inserted up to 15 cm (r/a = 0.7) into the plasma. Furthermore, the capacitive probe has a frequency bandwidth from 13 Hz to 100 kHz, amplifier-circuit limit, sufficient for studying the tearing modes (5-30 kHz) in the MST reversed-field pinch.

47 OTHER INSTRUMENTATION↗

Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors

Active matrix, flat-panel imagers (AMFPIs) employing a 2D matrix of a-Si addressing TFTs have become ubiquitous in many x-ray imaging applications due to their numerous advantages. However, under conditions of low exposures and/or high spatial resolution, their signal-to-noise performance is constrained by the modest system gain relative to the electronic additive noise. In this article, a strategy for overcoming this limitation through the incorporation of in-pixel amplification circuits, referred to as active pixel (AP) architectures, using polycrystalline-silicon (poly-Si) TFTs is reported. Compared to a-Si, poly-Si offers substantially higher mobilities, enabling higher TFT currents and the possibility of sophisticated AP designs based on both n- and p-channel TFTs. Three prototype indirect detection arrays employing poly-Si TFTs and a continuous a-Si photodiode structure were characterized. The prototypes consist of an array (PSI-1) that employs a pixel architecture with a single TFT, as well as two arrays (PSI-2 and PSI-3) that employ AP architectures based on three and five TFTs, respectively. While PSI-1 serves as a reference with a design similar to that of conventional AMFPI arrays, PSI-2 and PSI-3 incorporate additional in-pixel amplification circuitry. Compared to PSI-1, results of x-ray sensitivity demonstrate signal gains of {approx}10.7 and 20.9 for PSI-2 and PSI-3, respectively. These values are in reasonable agreement with design expectations, demonstrating that poly-Si AP circuits can be tailored to provide a desired level of signal gain. PSI-2 exhibits the same high levels of charge trapping as those observed for PSI-1 and other conventional arrays employing a continuous photodiode structure. For PSI-3, charge trapping was found to be significantly lower and largely independent of the bias voltage applied across the photodiode. MTF results indicate that the use of a continuous photodiode structure in PSI-1, PSI-2, and PSI-3 results in optical fill factors that are close to unity. In addition, the greater complexity of PSI-2 and PSI-3 pixel circuits, compared to that of PSI-1, has no observable effect on spatial resolution. Both PSI-2 and PSI-3 exhibit high levels of additive noise, resulting in no net improvement in the signal-to-noise performance of these early prototypes compared to conventional AMFPIs. However, faster readout rates, coupled with implementation of multiple sampling protocols allowed by the nondestructive nature of pixel readout, resulted in a significantly lower noise level of {approx}560 e (rms) for PSI-3.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muons Inc Master CRADA with Annex A for Magnetron Development

Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time.

43 PARTICLE ACCELERATORS↗

Single-Chip T/R Module for 1.2 GHz

A single-chip CMOS-based (complementary-metal-oxide-semiconductorbased) transmit/receive (T/R) module is being developed for L-band radar systems. Previous T/R module implementations required multiple chips employing different technologies (GaAs, Si, and others) combined with off-chip transmission lines and discrete components including circulators. The new design eliminates the bulky circulator, significantly reducing the size and mass of the T/R module. Compared to multi-chip designs, the single-chip CMOS can be implemented with lower cost. These innovations enable cost-effective realization of advanced phased array and synthetic aperture radar systems that require integration of thousands of T/R modules. The circulator is a ferromagnetic device that directs the flow of the RF (radio frequency) power during transmission and reception. During transmission, the circulator delivers the transmitted power from the amplifier to the antenna, while preventing it from damaging the sensitive receiver circuitry. During reception, the circulator directs the energy from the antenna to the low-noise amplifier (LNA) while isolating the output of the power amplifier (PA). In principle, a circulator could be replaced by series transistors acting as electronic switches. However, in practice, the integration of conventional series transistors into a T/R chip introduces significant losses and noise. The prototype single-chip T/R module contains integrated transistor switches, but not connected in series; instead, they are connected in a shunt configuration with resonant circuits (see figure). The shunt/resonant circuit topology not only reduces the losses associated with conventional semiconductor switches but also provides beneficial transformation of impedances for the PA and the LNA. It provides full singlepole/ double-throw switching for the antenna, isolating the LNA from the transmitted signal and isolating the PA from the received signal. During reception, the voltage on control line RX/TX (raised bar) is high, causing the field-effect transistor (FET) switch S1 to be closed, forming a parallel resonant tank circuit L1||C1. This circuit presents high impedance to the left of the antenna, so that the received signal is coupled to the LNA. At the same time, FET switches S2 and S3 are open, so that C2 is removed from the circuit (except for a small parasitic capacitance). The combination of L2 and C3 forms a matching network that transforms the antenna impedance of 50 ohms to a higher value from the perspective of the LNA input terminal. This transformation of impedance improves LNA noise figure by increasing the received voltage delivered to the input transistor. This allows lower transconductance and therefore a smaller transistor, which makes it possible to design the CMOS LNA for low power consumption. During transmission, the voltage on control line RX/TX (raised bar) is low, causing switch S1 to be open. In this configuration, the combination of L1 and C1 transforms the antenna impedance to a lower value from the perspective of the PA. This low impedance is helpful in producing a relatively high output power compatible with the low CMOS operating potential. At the same time, switches S2 and S3 are closed, forming the parallel resonant tank circuit L2||C2. This circuit presents high impedance to the right of the antenna, directing the PA output signal to the antenna and away from the LNA. During this time, S3 presents a short circuit across the LNA input terminals to guarantee that the voltage seen by the LNA is small enough to prevent damage.

Moussessian, Alina↗

Detecting Conductive Liquid Leaking from Nonconductive Pipe

A method that can be implemented with relatively simple electronic circuitry provides a capability for detecting leakage of an electrically conductive liquid from an electrically nonconductive underground pipe. Alternatively or in addition, the method can be applied to locate the pipe, whether or not there is a leak. Although the method is subject to limitations (some of which are described below), it is still attractive as an additional option for detecting leaks and locating pipes without need for extensive digging. The method is based on capacitive coupling of an alternating electrical signal from the liquid to a portable electronic unit that resembles a metal detector. A signal voltage is applied to the liquid at some convenient point along the pipe: for example, the signal could be coupled into the liquid via an aboveground metal pipe fitting, the interior surface of which is in contact with the liquid. The signal is conducted through the liquid in the pipe; in the case of diffusive leak of liquid into the surrounding ground, the signal is conducted through the leak, into the portion of the adjacent ground that has become soaked with the liquid. (A drip leak cannot be detected by this method because there is no conductive path between the liquid inside and the liquid outside the pipe.) The portable unit includes an electrically conductive plate connected to the input terminal of an amplifier. When the plate is brought near the pipe or the leaked liquid, a small portion of the signal power is coupled capacitively from the liquid to the plate. The user scans the plate near the ground surface to find the locus of maximum signal strength. The leak can be identified as a relatively wide area, contiguous with the location of the pipe, over which the signal is detectable.

Youngquist, Robert C.↗

Captain Electronics Technical Report

This report details the current layout of the electronics for the mini-CAPTAIN detector system, as well as the lessons learned during commissioning. We will present some electronics suggestions for future LArTPC systems. Mini-CAPTAIN is one of three detectors used in the Cryogenic Apparatus for Precision Tests of Argon Interactions with Neutrino (CAPTAIN) project at Los Alamos National Lab (LANL). The detector uses many of the same electronic components as current and developing LArTPC experiments. This includes the motherboards, service cards, amplifiers and ADC made by Brookhaven National Laboratory (BNL) and the front-end modules (FEM) made by Nevis Labs. The cold electronics performed well in both vacuum and cryogenic environments after months of exposure. Mini-CAPTAIN was tested with two liquid nitrogen and three liquid argon run cycles. The final testing was performed at the Weapons Neutron Research (WNR) facility at LANSCE. Mini-CAPTAIN was able to maintain a clean electrical signal through most of the test cycles. Most noise reduction was achieved with power source filtering and careful attention to the ground configuration. Direct oscilloscope probing on the front-end output provided the fastest analysis and correction of noise sources. Ground path assumptions and integrity were verified with frequent impedance checks. A high voltage break down event damaged some of the channels on the motherboards and a number of the wire decoupling capacitors. This temporarily introduced significant noise on the wire planes due to current leakage. The detector was taken apart and reassembled three times, with successful noise reduction after each activity. The current raw signal-to-noise ratio is 9 to 1.

42 ENGINEERING↗

Power flow control using distributed saturable reactors

A magnetic amplifier includes a saturable core having a plurality of legs. Control windings wound around separate legs are spaced apart from each other and connected in series in an anti-symmetric relation. The control windings are configured in such a way that a biasing magnetic flux arising from a control current flowing through one of the plurality of control windings is substantially equal to the biasing magnetic flux flowing into a second of the plurality of control windings. The flow of the control current through each of the plurality of control windings changes the reactance of the saturable core reactor by driving those portions of the saturable core that convey the biasing magnetic flux in the saturable core into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the saturable core.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scintillation counter and wire chamber front end modules for high energy physics experiments

This document describes two front-end modules developed for the proposed MIPP upgrade (P-960) experiment at Fermilab. The scintillation counter module was developed for the Plastic Ball detector time and charge measurements. The module has eight LEMO 00 input connectors terminated with 50 ohms and accepts negative photomultiplier signals in the range 0.25...1000 pC with the maximum input voltage of 4.0 V. Each input has a passive splitter with integration and differentiation times of {approx}20 ns. The integrated portion of the signal is digitized at 26.55 MHz by Analog Devices AD9229 12-bit pipelined 4-channel ADC. The differentiated signal is discriminated for time measurement and sent to one of the four TMC304 inputs. The 4-channel TMC304 chip allows high precision time measurement of rising and falling edges with {approx}100 ps resolution and has internal digital pipeline. The ADC data is also pipelined which allows deadtime-less operation with trigger decision times of {approx}4 {micro}s. The wire chamber module was developed for MIPP EMCal detector charge measurements. The 32-channel digitizer accepts differential analog signals from four 8-channel integrating wire amplifiers. The connection between wire amplifier and digitizer is provided via 26-wire twist-n-flat cable. The wire amplifier integrates input wire current and has sensitivity of 275 mV/pC and the noise level of {approx}0.013 pC. The digitizer uses the same 12-bit AD9229 ADC chip as the scintillator counter module. The wire amplifier has a built-in test pulser with a mask register to provide testing of the individual channels. Both modules are implemented as a 6Ux220 mm VME size board with 48-pin power connector. A custom europack (VME) 21-slot crate is developed for housing these front-end modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Harmonic filter for magnetic amplifier

A magnetic amplifier includes a permeable core having multiple legs. Control windings wound around separate legs are spaced apart and connected in series in an anti-symmetric relation. Harmonic filters are positioned adjacent to the control windings to attenuate even-ordered harmonics generated by alternating load current passing through a portion of the legs. The control windings bias magnetic flux arising from control current flowing through one of the control windings which is substantially equal to the biasing magnetic flux flowing into a second control winding. The flow of the control current through each of the control windings changes the reactance of the permeable core reactor by driving those portions of the permeable core that convey the biasing magnetic flux into saturation. The phasing of the control winding limits a voltage induced in the plurality of control windings caused by a magnetic flux passing around a portion of the permeable core.

42 ENGINEERING↗

NSTX-U In-Vessel Control Coils’ Design Concept

In this paper, a successful conceptual design was completed to develop in-vessel control coils [non-axisymmetric control coils (NCCs)]. The NCCs are a series of saddle coils that are intended to satisfy a number of physics criteria including magnetic breaking, error field control, fast resistive wall mode (RWM) control, and edge-localized-mode stabilization. Customized mineral-insulated cable (MIC) was selected for the conductor material. The MIC was made from oxygen-free copper conductor, high purity magnesium oxide powder insulation, and 304 stainless steel sleeve cover. Sample MIC was purchased from an outside supplier, and various tests were conducted for design and performance verification including high-voltage testing, which necessitated the development of special test terminations. A concept design was also developed for terminating the MIC ends using the nonconductive and vacuum-sealed technique. Two alternative designs were proposed for joints inside the vacuum vessel (VV). The NCCs are designed to be mounted in front of the primary passive plates and underneath the plasma-facing component (PFC) tiles. The passive plates will be modified to accommodate the coils. A new PFC tile design concept was developed using high-Z materials. New designs for the penetrations through the VV wall were developed. One port per coil was planned. Finally, a new power patch panel will be required to provide the ability for various combinations of connections between the NCC, the existing RWM coils, and the existing switching power amplifier power suppliers.

42 ENGINEERING↗

NASA Tech Briefs, February 2003

opics covered include: Integrated Electrode Arrays for Neuro-Prosthetic Implants; Eroding Potentiometers; Common/Dependent-Pressure-Vessel Nickel-Hydrogen Batteries; 120-GHz HEMT Oscillator With Surface-Wave-Assisted Antenna; 80-GHz MMIC HEMT Voltage-Controlled Oscillator; High-Energy-Density Capacitors; Microscale Thermal-Transpiration Gas Pump; Instrument for Measuring Temperature of Water; Improved Measurement of Coherence in Presence of Instrument Noise; Compact Instruments Measure Helium-Leak Rates; Irreversible Entropy Production in Two-Phase Mixing Layers; Subsonic and Supersonic Effects in Bose-Einstein Condensate; Nanolaminate Mirrors With "Piston" Figure-Control Actuators; Mixed Conducting Electrodes for Better AMTEC Cells; Process for Encapsulating Protein Crystals; Lightweight, Self-Deployable Wheels; Grease-Resistant O Rings for Joints in Solid Rocket Motors; LabVIEW Serial Driver Software for an Electronic Load; Software Computes Tape-Casting Parameters; Software for Tracking Costs of Mars Projects; Software for Replicating Data Between X.500 and LDAP Directories; The Technical Work Plan Tracking Tool; Improved Multiple-DOF SAW Piezoelectric Motors; Propulsion Flight-Test Fixture; Mechanical Amplifier for a Piezoelectric Transducer; Swell Sleeves for Testing Explosive Devices; Linear Back-Drive Differentials; Miniature Inchworm Actuators Fabricated by Use of LIGA; Using ERF Devices to Control Deployments of Space Structures; High-Temperature Switched-Reluctance Electric Motor; System for Centering a Turbofan in a Nacelle During Tests; Fabricating Composite-Material Structures Containing SMA Ribbons; Optimal Feedback Control of Thermal Networks; Artifacts for Calibration of Submicron Width Measurements; Navigating a Mobile Robot Across Terrain Using Fuzzy Logic; Designing Facilities for Collaborative Operations; and Quantitating Iron in Serum Ferritin by Use of ICP-MS.

Source record↗

Space-Qualified Traveling-Wave Tube

The L-3 Communications Electron Technologies, Inc. Model 999HA traveling-wave tube (TWT), was developed for use as a high-power microwave amplifier for high-rate transmission of data and video signals from deep space to Earth (see figure). The 999HA is a successor to the 999H a non-space qualified TWT described in High-Power, High-Efficiency Ka-Band Traveling-Wave Tube (LEW-17900-1), NASA Tech Briefs, Vol. 31, No. 2 (February 2007), page 32. Operating in the 31.8-to-32.3 GHz frequency band, the 999HA has been shown to generate 252 W of continuous- wave output power at 62 percent overall power efficiency a 75-percent increase in output power over the 999H. The mass of the 999HA is 35 percent less than that of the 999H. Moreover, taking account of the elimination of a Faraday cage that is necessary for operation of the 999H but is obviated by a redesign of high-voltage feed-throughs for the 999HA, the overall reduction in mass becomes 57 percent with an 82 percent reduction in volume. Through a series of rigorous tests, the 999HA has been qualified for operation aboard spacecraft with a lifetime exceeding seven years. Offspring of the 999HA will fly on the Kepler and Lunar Reconnaissance Orbiter missions.

Wilson, Jeffrey D.↗

Flux-coherent series SQUID array magnetometers operating above 77 K with superior white flux noise than single-SQUIDs at 4.2 K

A very promising direction to improve the sensitivity of magnetometers based on superconducting quantum interference devices (SQUIDs) is to build a series-array of N non-interacting SQUIDs operating flux-coherently, because in this case their voltage modulation depth, ΔV, linearly scales with N whereas the white flux noise S{sub Φ}{sup 1/2} decreases as 1/N{sup 1/2}. Here, we report the realization of both these improvements in an advanced layout of very large SQUID arrays made of YBa{sub 2}Cu{sub 3}O{sub 7}. Specially designed with large area narrow flux focusers for increased field sensitivity and improved flux-coherency, our arrays have extremely low values for S{sub Φ}{sup 1/2} between (0.25 and 0.44) μΦ{sub 0}/Hz{sup 1/2} for temperatures in the range (77–83) K. In this respect, they outperform niobium/aluminium trilayer technology-based single-SQUIDs operating at 4.2 K. Moreover, with values for ΔV and transimpedance in the range of (10–17) mV and (0.3–2.5) kΩ, respectively, a direct connection to a low-noise room temperature amplifier is allowed, while matching for such readout is simplified and the available bandwidth is greatly increased. These landmark performances suggest such series SQUID arrays are ideal candidates to replace single-SQUIDs operating at 4.2 K in many applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗