Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

SULFATE SOLUBILITY LIMIT VERIFICATION FOR DWPF SLUDGE BATCH 7B

The objective of this study was to determine a sulfate solubility limit in glass for Sludge Batch 7b (SB7b). The SB7b composition projection provided by Savannah River Remediation (SRR) on May 25, 2011 was used as the basis for formulating glass compositions to determine the sulfate limit. Additions of Na{sub 2}O to the projected sludge composition were made by the Savannah River National Laboratory (SRNL) due to uncertainty in the final concentration of Na{sub 2}O for SB7b, which is dependent on washing effectiveness and the potential need to add NaOH to ensure an acceptable projected operating window. Additions of 4, 6, and 8 wt % Na{sub 2}O were made to the nominal May 25, 2011 composition projection. An updated SB7b composition projection was received from SRR on August 4, 2011. Due to compositional similarities, no additional experimental work using the August 4, 2011 compositions was considered to be necessary for this study. Both Frit 418 and Frit 702 were included in this study. The targeted sulfate (SO{sub 4}{sup 2-}) concentrations of the study glasses were selected within the range of 0.6 to 0.9 wt % in glass. A total of 52 glass compositions were selected based on the compositional variables of Na{sub 2}O addition, Actinide Removal Process (ARP) stream addition, waste loading, frit composition, and sulfate concentration. The glasses were batched, melted, and characterized following SRNL procedures. Visual observations were recorded for each glass after it cooled and used as in indicator of sulfur retention. Representative samples of each of the glasses fabricated were subjected to chemical analysis to determine whether the targeted compositions were met, as well as to determine the quantity of sulfate that was retained after melting. In general, the measured composition data showed that there were only minor issues in meeting the targeted compositions for the study glasses, and the measured sulfate concentrations for each study glass were within 10% of the targeted values. The results for the SB7b glasses fabricated with Frit 418 showed an apparent trend of increasing sulfate retention with increasing Na{sub 2}O additions to the 5/25/11 sludge projection. This trend appears contradictory to other recent studies of sulfate retention in Defense Waste Processing Facility (DWPF) type glasses. Additional apparent contradictions to this trend were found in the data collected in the present study. Overall, the results for the SB7b sulfate study glasses with Frit 418 and the 5/25/11 projection with Na{sub 2}O additions showed that subtle changes in this complex glass composition impacted the degree of sulfate retention. These results do however provide confidence that a 0.6 wt % sulfate limit in glass is warranted for Frit 418 with the SB7b compositions evaluated in this study. The results for the SB7b glasses fabricated with Frit 702 are consistent with those of the previous SB7a study in that Frit 702 allowed for higher sulfate retention as compared to Frit 418 for the same sludge compositions. It is recommended that the DWPF implement a sulfate concentration limit of 0.6 wt % in glass for SB7b processing with Frit 418. If a higher than projected sulfate concentration is measured when SB7b processing begins (i.e., if a sulfate concentration higher than 0.6 wt % becomes necessary to achieve targeted waste loadings), DWPF should consider a transition to Frit 702. The sulfate limit could likely be raised to 0.8 wt % by transitioning to this frit. However, if DWPF considers transitioning from Frit 418 to Frit 702, additional glasses should be fabricated to confirm this higher limit due to the issues with incorrect B{sub 2}O{sub 3} concentrations for some of the glasses made with Frit 702 in this study. There are several factors other than sulfate retention that must also be carefully considered prior to changing frit compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Applications systems verification and transfer project. Volume 6: Operational applications of satellite snow-cover observations NOAA/NESS support study

Geostationary and polar orbiting satellite data from the National Oceanic and Atmospheric Administration were used to operationally provide field hydrologists with basin snowcover percentages for inclusion in runoff models. Data reduction is accomplished thru the use of optical rectification devices and electronic color density slicers. Over two thousand satellite-derived snow maps covering 30 different basins in the western United States were provided to users. Plans for improving snowmapping techniques on computer interactive systems and by all-digital analysis are presented. A description of the newest generation of NOAA polar orbiters, TIROS-N, and its potential for snowmapping is reviewed. Snowcover percentages for all basins determined between November 1974 and July 1978 are presented in tabular format.

Schneider, S. R.↗

Comparison of ORSAT and SCARAB Reentry Analysis Tools for a Generic Satellite Test Case

Reentry analysis is essential to understanding the consequences of the full life cycle of a spacecraft. Since reentry is a key factor in spacecraft development, NASA and ESA have separately developed tools to assess the survivability of objects during reentry. Criteria such as debris casualty area and impact energy are particularly important to understanding the risks posed to people on Earth. Therefore, NASA and ESA have undertaken a series of comparison studies of their respective reentry codes for verification and improvements in accuracy. The NASA Object Reentry Survival Analysis Tool (ORSAT) and the ESA Spacecraft Atmospheric Reentry and Aerothermal Breakup (SCARAB) reentry analysis tools serve as standard codes for reentry survivability assessment of satellites. These programs predict whether an object will demise during reentry and calculate the debris casualty area of objects determined to survive, establishing the reentry risk posed to the Earth's population by surviving debris. A series of test cases have been studied for comparison and the most recent uses "Testsat," a conceptual satellite composed of generic parts, defined to use numerous simple shapes and various materials for a better comparison of the predictions of these two codes. This study is an improvement on the others in this series because of increased consistency in modeling techniques and variables. The overall comparison demonstrated that the two codes arrive at similar results. Either most objects modeled resulted in close agreement between the two codes, or if the difference was significant, the variance could be explained as a case of semantics in the model definitions. This paper presents the main results of ORSAT and SCARAB for the Testsat case and discusses the sources of any discovered differences. Discussion of the results of previous comparisons is made for a summary of differences between the codes and lessons learned from this series of tests.

Kelley, Robert L.↗

Study of the dijet invariant mass in W + jets events by the D0 Collaboration

The recent claim by the CDF Collaboration of a possible anomalous dijet resonance in their data required experimental verification from other hadron collider experiments. We present a study of the dijet invariant mass spectrum in events with two jets produced in association with a W -> \ellnu boson at the D\O experiment. We investigate the dijet mass range between 110 GeV/c2 and 170 GeV/c2 and find no evidence for any resonant dijet production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Influence of backup bearings and support structure dynamics on the behavior of rotors with active supports

Substantial progress has been made toward the goals of this research effort in the past six months. A simplified rotor model with a flexible shaft and backup bearings has been developed. The model is based upon the work of Ishii and Kirk. Parameter studies of the behavior of this model are currently being conducted. A simple rotor model which includes a flexible disk and bearings with clearance has been developed and the dynamics of the model investigated. The study consists of simulation work coupled with experimental verification. The work is documented in the attached paper. A rotor model based upon the T-501 engine has been developed which includes backup bearing effects. The dynamics of this model are currently being studied with the objective of verifying the conclusions obtained from the simpler models. Parallel simulation runs are being conducted using an ANSYS based finite element model of the T-501.

Flowers, George T.↗

Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance

The two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT). The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp). The detector calibration factor was determined using 300 kVp X-ray beams so that we can use the same calibration factor for dosimetric verification of high-dose-rate (HDR) brachytherapy. The phantom used for this measurement consists of multiple catheters, the IBA MatriXX detector, and water-equivalent slab of RW3 to provide full scattering conditions. The treatment planning system (TPS) (Oncentra brachy version 3.3, Nucletron BV, Veenendaal, the Netherlands) dose distribution was calculated on the computed tomography (CT) scan of this phantom. The measured and TPS calculated distributions were compared in IBA Dosimetry OmniPro-I'mRT software. The quality of agreement was quantified by the gamma ({gamma}) index (with 3% delta dose and distance criterion of 2 mm) for 9 sets of plans. Using a dedicated phantom capable of receiving 5 brachytherapy intralumenal catheters a QA procedure was developed for end-to-end dosimetric evaluation for routine QA checks. The 2D ion chamber array dose dependence was found to be linear for 100-300 kVp and the detector response (k{sub user}) showed strong energy dependence for 100-300 kVp energy range. For the Ir-192 brachytherapy HDR source, dosimetric evaluation k{sub user} factor determined by photon beam of energy of 300 kVp was used. The maximum mean difference between ion chamber array measured and TPS calculated was 3.7%. Comparisons of dose distribution for different test plans have shown agreement with >94.5% for {gamma} {<=}1. Dosimetric QA can be performed with the 2D ion chamber array to confirm primary source strength calibration is properly updated in both the TPS and treatment delivery console computers. The MatriXX Evolution ionization chamber array has been found to be reliable for measurement of both absolute dose and relative dose distributions for the Ir-192 brachytherapy HDR source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Advanced Risk Reduction Tool (ARRT) Special Case Study Report: Science and Engineering Technical Assessments (SETA) Program

This special case study report presents the Science and Engineering Technical Assessments (SETA) team's findings for exploring the correlation between the underlying models of Advanced Risk Reduction Tool (ARRT) relative to how it identifies, estimates, and integrates Independent Verification & Validation (IV&V) activities. The special case study was conducted under the provisions of SETA Contract Task Order (CTO) 15 and the approved technical approach documented in the CTO-15 Modification #1 Task Project Plan.

Kirsch, Paul J.↗

Automated evaluation of setup errors in carbon ion therapy using PET: Feasibility study

Purpose: To investigate the possibility of detecting patient mispositioning in carbon-ion therapy with particle therapy positron emission tomography (PET) in an automated image registration based manner. Methods: Tumors in the head and neck (H and N), pelvic, lung, and brain region were investigated. Biologically optimized carbon ion treatment plans were created with TRiP98. From these treatment plans, the reference β{sup +}-activity distributions were calculated using a Monte Carlo simulation. Setup errors were simulated by shifting or rotating the computed tomography (CT). The expected β{sup +} activity was calculated for each plan with shifts. Finally, the reference particle therapy PET images were compared to the “shifted” β{sup +}-activity distribution simulations using the Pearson's correlation coefficient (PCC). To account for different PET monitoring options the inbeam PET was compared to three different inroom scenarios. Additionally, the dosimetric effects of the CT misalignments were investigated. Results: The automated PCC detection of patient mispositioning was possible in the investigated indications for cranio-caudal shifts of 4 mm and more, except for prostate tumors. In the rather homogeneous pelvic region, the generated β{sup +}-activity distribution of the reference and compared PET image were too much alike. Thus, setup errors in this region could not be detected. Regarding lung lesions the detection strongly depended on the exact tumor location: in the center of the lung tumor misalignments could be detected down to 2 mm shifts while resolving shifts of tumors close to the thoracic wall was more challenging. Rotational shifts in the H and N and lung region of +6° and more could be detected using inroom PET and partly using inbeam PET. Comparing inroom PET to inbeam PET no obvious trend was found. However, among the inroom scenarios a longer measurement time was found to be advantageous. Conclusions: This study scopes the use of various particle therapy PET verification techniques in four indications. The automated detection of patients' setup errors was investigated in a broad accumulation of data sets. The evaluation of introduced setup errors is performed automatically, which is of utmost importance to introduce highly required particle therapy monitoring devices into the clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-563: Multi-Fraction Stereotactic Radiosurgery with Extend System of Gamma Knife: Treatment Verification Using Indigenously Designed Patient Simulating Multipurpose Phantom

Purpose: Aim of the study is to evaluate mechanical and radiological accuracy of multi-fraction regimen and validate Gamma knife based fractionation using newly developed patient simulating multipurpose phantom. Methods: A patient simulating phantom was designed to verify fractionated treatments with extend system (ES) of Gamma Knife however it could be used to validate other radiotherapy procedures as well. The phantom has options to insert various density material plugs and mini CT/MR distortion phantoms to analyze the quality of stereotactic imaging. An additional thorax part designed to predict surface doses at various organ sites. The phantom was positioned using vacuum head cushion and patient control unit for imaging and treatment. The repositioning check tool (RCT) was used to predict phantom positioning under ES assembly. The phantom with special inserts for film in axial, coronal and sagittal plane were scanned with X-Ray CT and the acquired images were transferred to treatment planning system (LGP 10.1). The focal precession test was performed with 4mm collimator and an experimental plan of four 16mm collimator shots was prepared for treatment verification of multi-fraction regimen. The prescription dose of 5Gy per fraction was delivered in four fractions. Each fraction was analyzed using EBT3 films scanned with EPSON 10000XL Scanner. Results: The measurement of 38 RCT points showed an overall positional accuracy of 0.28mm. The mean deviation of 0.28% and 0.31 % were calculated as CT and MR image distortion respectively. The radiological focus accuracy test showed its deviation from mechanical center point of 0.22mm. The profile measurement showed close agreement between TPS planned and film measured dose. At tolerance criteria of 1%/1mm gamma index analysis showed a pass rate of > 95%. Conclusion: Our results show that the newly developed multipurpose patient simulating phantom is highly suitable for the verification of fractionated stereotactic radiosurgery using ES of Gamma knife. The study is a part of intramural research project of Research Section, All India Institute of Medical Sciences New Delhi India (A 247)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model-Based Verification and Validation of the SMAP Uplink Processes

This case study stands as an example of how a project can validate a system-level design earlier in the project life cycle than traditional V&V processes by using simulation on a system model. Specifically, this paper describes how simulation was added to a system model of the Soil Moisture Active-Passive (SMAP) mission's uplink process.Also discussed are the advantages and disadvantages of the methods employed and the lessons learned; which are intended to benefit future model-based and simulation-based V&V development efforts.

verification and validation (V&V)↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

Computational solution verification and validation applied to a thermal model of a ruggedized instrumentation package

This study details a methodology for quantification of errors and uncertainties of a finite element heat transfer model applied to a Ruggedized Instrumentation Package (RIP). The proposed verification and validation (V&V) process includes solution verification to examine errors associated with the code's solution techniques, and model validation to assess the model's predictive capability for quantities of interest. The model was subjected to mesh resolution and numerical parameters sensitivity studies to determine reasonable parameter values and to understand how they change the overall model response and performance criteria. To facilitate quantification of the uncertainty associated with the mesh, automatic meshing and mesh refining/coarsening algorithms were created and implemented on the complex geometry of the RIP. Automated software to vary model inputs was also developed to determine the solution’s sensitivity to numerical and physical parameters. The model was compared with an experiment to demonstrate its accuracy and determine the importance of both modelled and unmodelled physics in quantifying the results' uncertainty. An emphasis is placed on automating the V&V process to enable uncertainty quantification within tight development schedules.

97 MATHEMATICS AND COMPUTING↗

Validating Performance Models for Hybrid Power Plant Control Assessment

The need for simple, but accurate performance models of wind turbine generators (WTGs), photovoltaic (PV) plants, and battery energy storage systems (BESS) for various hybrid power plant (HPP) studies motivates the present work. Particularly, the development and verification stage of HPP controls requires reduced-order models to minimize the complexity and computation effort of simulation platforms. In this paper, such models are proposed, and the most essential parts of the models are validated through field measurements. The models target power system integration studies involving active and reactive power, as well as frequency and voltage regulation where detailed models, as proposed in the standards, can be cumbersome. Field measurements of two Vestas WTGs, one 1-MW PV plant, and one 1-MW/1-MWh BESS are used for model validation. The results show that the WTG and PV performance models correctly estimate the power generation variability according to fluctuations in wind speed and solar irradiance. The BESS performance model provides satisfactory results related to grid-forming control performance and estimation of state-of-charge. The presented validation work enables using the proposed performance models for power system studies and HPP control design in all model-based design stages, that is, preliminary analysis, design, verification, and validation with a high level of confidence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast and Accurate Core Analysis by the Full-Immersion Pressure-Pulse Decay: Part 1—Theory

Summary Core-scale measurements are considered the ground truth that oil and gas or electric utility companies use to predict the migration of fluids such as oil, natural gas, carbon dioxide, or brine deep underground during their extraction or injection operations. To provide a greater understanding of petrophysical properties of low-permeability geologic formations such as shales and tight gas sandstones, this study introduces a novel core-analysis procedure. The technique follows conventional pressure-pulse-decay permeametry, where the pressure in an inlet chamber adjacent to a cylindrical core plug undergoes a rapid pressurization, the system is shut in, and the pressure reaches a new equilibrium. However, unlike a standard unidirectional pressure-pulse decay, the full-immersion pressure-pulse decay (Hannon 2019) applies a pressure disturbance to the entire outer surface area of the sample. This article covers the numerical simulator designed to model flow through an anisotropic porous sample in this scenario. The model assumes distinct but uniform permeabilities along the radial and axial directions of the cylindrical plug sample. When extracting a plug vertically (or perpendicular to bedding), the permeability along the radial direction associates with the horizontal permeability (i.e., parallel to bedding), whereas in the axial direction, flow occurs perpendicular to bedding (a vertical permeability). Investigations of these model outputs demonstrate an approximately 20-fold decrease in time to complete a full-immersion experiment compared with conventional pressure-pulse decay. Furthermore, the pressure-decay curves resulting from the full-immersion method have slightly different shapes than those resulting from other unidimensional transient methods. These differences begin to demonstrate that, under achievable experimental conditions, the analysis of pressure data from one full-immersion test could enable the simultaneous estimation of the apparent permeabilities parallel and perpendicular to bedding of a cylindrical sample in addition to its porosity. A follow-up article finalizes the proof of this capability with a parameter-estimation procedure and presents experimental verification through a proof-of-concept study. Described in greater detail in that article, the parameter estimator requires multiple forward simulations to analyze the data, which behooves minimizing the compute time for each simulation. By using an alternating direction implicit time-marching scheme and a structured but variably spaced grid, the numerical simulator built for this purpose provides a forward model output with suitable accuracy in approximately 0.5 seconds.

Energy & Fuels↗

SU-E-T-140: Dynamic Wave Arc Trajectory Verification Using KV X-Ray Fluoroscopy

Purpose: Purpose: This study investigates the geometric accuracy of simultaneous Gantry/Ring rotation during Dynamic Wave Arc (DWA) delivery. Methods: The Vero SBRT system consists of a 6MV LINAC mounted on an O-ring gantry that can rotate around the vertical axis (±60°), similar to couch rotation on C-arm gantries. To provide CBCT and fluoroscopy imaging functionalities, two orthogonal kV imaging units are attached to the O-ring at −45°/+45° from the beam axis.Dynamic Wave Arc maximizes Vero's motion capabilities by employing synchronized gantry and ring motion on a complex non-coplanar trajectory in combination with aperture based optimized MLC segments.Four wave arc trajectories (T1-4) were delivered using a cubic phantom with a configuration of five lead beads. O-ring gantry position information was retrieved through continuous dual-source kV X-ray image acquisition during DWA. An in-house algorithm read in the image set, extracted the projected marker positions and determined the angulation through reconstruction of the beam source position. The geometric error was quantified as the distance between the independently detected positions from kV-images and reference trajectory derived from the treatment plan in the Ring-Gantry space. Results: The average displacement between the 3D gantry/ring positions reconstructed from the fluoroscopy images and the reference trajectory was 0.346 mm (SD 0,171) for T1. A mean offset of 0.348 mm (SD 0,182) and 0.357 mm (SD 0.194) was observed for trajectory T2(2segmens) and T3(4segments), respectively. The saw shape T4 presented a mean geometric error of 0.363 (SD 0.156). The overall systematic error of 0.350 was caused by the difference between planned reference trajectory created by linear interpolation between CP, and the machine delivery following a spline curve. Conclusion: An independent geometric QA approach has been developed for DWA delivery verification, successfully applied on diverse trajectories and disclosed that the Vero system is capable of accurately follow complex trajectories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical detection threshold of the proton-acoustic range verification technique

Purpose: Range verification in proton therapy using the proton-acoustic signal induced in the Bragg peak was investigated for typical clinical scenarios. The signal generation and detection processes were simulated in order to determine the signal-to-noise limits. Methods: An analytical model was used to calculate the dose distribution and local pressure rise (per proton) for beams of different energy (100 and 160 MeV) and spot widths (1, 5, and 10 mm) in a water phantom. In this method, the acoustic waves propagating from the Bragg peak were generated by the general 3D pressure wave equation implemented using a finite element method. Various beam pulse widths (0.1–10 μs) were simulated by convolving the acoustic waves with Gaussian kernels. A realistic PZT ultrasound transducer (5 cm diameter) was simulated with a Butterworth bandpass filter with consideration of random noise based on a model of thermal noise in the transducer. The signal-to-noise ratio on a per-proton basis was calculated, determining the minimum number of protons required to generate a detectable pulse. The maximum spatial resolution of the proton-acoustic imaging modality was also estimated from the signal spectrum. Results: The calculated noise in the transducer was 12–28 mPa, depending on the transducer central frequency (70–380 kHz). The minimum number of protons detectable by the technique was on the order of 3–30 × 10{sup 6} per pulse, with 30–800 mGy dose per pulse at the Bragg peak. Wider pulses produced signal with lower acoustic frequencies, with 10 μs pulses producing signals with frequency less than 100 kHz. Conclusions: The proton-acoustic process was simulated using a realistic model and the minimal detection limit was established for proton-acoustic range validation. These limits correspond to a best case scenario with a single large detector with no losses and detector thermal noise as the sensitivity limiting factor. Our study indicated practical proton-acoustic range verification may be feasible with approximately 5 × 10{sup 6} protons/pulse and beam current.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SAFE50 Reference Design Study for Large-Scale High-Density Low-Altitude UAS Operations in Urban Areas

Enabling safe, routine, and high-density flight operations of small UAS at low-altitude over heavily populated urban centers presents a difficult challenge for emerging UAS Traffic Management (UTM) system concepts. Urban operations by definition involve flight over people, property, and infrastructure. Low-altitude urban environments - such as urban canyons – are one of the most difficult areas for UTM to consider. Mission concepts require routine operations in a cluttered radio-frequency (RF) environment with degraded or denied Global Positioning System (GPS) reception. Flights with any appreciable distance will be beyond visual and communications line-of-sight from ground operators. Timely detection and response to emergencies and onboard failures, which is critical for safe aircraft operation, will be difficult. This work seeks to establish a feasible reference autonomy architecture for autonomous vehicles in an urban UTM system, then verifying and validating this architecture within a complete UTM concept point-design and systems analysis study. In this paper, we present the results from the NASA SAFE50 conceptual design and systems study that investigates the trade-space of urban UTM operations. This advanced conceptual design study develops a feasible, verified, validated point-design solution. The SAFE50 point-design concept places emphasis on advanced, highly-autonomous, and highly-capable vehicles that favors intelligent onboard autonomy over direct human control with today's technologies and operating in today's urban environments. This paper focuses on an general overview of the design study, highlighting decisions made in the architectural solution. This paper will presents a summary of the study, architectures, and requirements. We present an overview of the architecture designs as derived from the top-level UTM system. The point-design has been implemented in both simulation and through flight testing of hardware design prototypes. The results from simulation and flight testing as part of the verification and validation process of the reference design study.

Ippolito, Corey A.↗