Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visual Examination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Visual Outcome and Tumor Control After Conformal Radiotherapy for Patients With Optic Nerve Sheath Meningioma

Purpose: Optic nerve sheath meningioma (ONSM) is a rare tumor that almost uniformly leads to visual dysfunction and even blindness without intervention. Because surgical extirpation carries a high risk of postoperative blindness, vision-sparing treatment strategies are desirable. Methods and Materials: We retrospectively reviewed the outcomes of 25 patients (25 optic nerves) with ONSM, treated at a single institution with conformal fractionated radiotherapy by either stereotactic photon or proton radiation. Primary endpoints were local control and visual acuity. Results: The patients presented with symptoms of visual loss (21) or orbital pain (3) or were incidentally diagnosed by imaging (3). The mean age was 44 years, and 64% were female patients. The indication for treatment was the development or progression of symptoms. Of the patients, 13 were treated with photons, 9 were treated with protons, and 3 received a combination of photons and protons. The median dose delivered was 50.4 gray equivalents (range, 45-59.4 gray equivalents). Median follow-up after radiotherapy was 30 months (range, 3-168 months), with 3 patients lost to follow-up. At most recent follow-up, 21 of 22 patients (95%) had improved (14) or stable (7) visual acuity. One patient had worsened visual acuity after initial postirradiation improvement. Of the 22 patients, 20 (95%) had no radiographic progression. Three patients had evidence of asymptomatic, limited retinopathy on ophthalmologic examination, and one had recurrent ONSM 11 years after treatment. Conclusions: Highly conformal, fractionated radiation therapy for symptomatic primary ONSM provides tumor control and improvement in visual function in most cases, with minimal treatment-induced morbidity. Longer follow-up is needed to assess the durability of tumor control and treatment-related late effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

LIQUID: an-open source software for identifying lipids in LC-MS/MS-based lipidomics data

We introduce an open-source software, LIQUID, for semi-automated processing and visualization of LC-MS/MS based lipidomics data. LIQUID provides users with the capability to process high throughput data and contains a customizable target library and scoring model per project needs. The graphical user interface provides visualization of multiple lines of spectral evidence for each lipid identification, allowing rapid examination of data for making confident identifications of lipid molecular species.

Environmental Molecular Sciences Laboratory↗

LIQUID

LIQUID is a software tool for identifying lipids in LC-MS/MS-based lipidomics data. It is described in publication LIQUID: an-open source software for identifying lipids in LC-MS/MS-based lipidomics data (doi: 10.1093/bioinformatics/btx046). LIQUID provides users with the capability to process high throughput data and contains a customizable target library and scoring model per project needs. The graphical user interface provides visualization of multiple lines of spectral evidence for each lipid identification, allowing rapid examination of data for making confident identifications of lipid molecular species.

Payne, Sam↗

Microbiological and Chemical Test Results on an Unknown Material from the L-Area Spent Fuel Basin

Two sampling events were completed to obtain cobweb-like material from the L-Area basin to determine what the material is and any potential impacts the material may have on the basin. The first sampling indicated that the material has a biological component but the low amount of material obtained from sampling was insufficient for full microbial and chemical analysis. The amount from the second sampling was more, approximately 50 ml. The material consisted of microorganisms, trace metals, and crystalline materials. The microorganisms are mostly, if not exclusively bacteria and this result indicates that the material and formation was mostly likely the result of biological activities. The highest concentration metals measured in the basin material include silica, aluminum, titanium, and iron. This microbiological matrix was dominated by many different types of heterotrophic bacteria, meaning that they are dependent upon external supplies of organic carbon and nutrients. Without these external inputs the bacteria cannot sustain themselves. Inferred from the measured levels of microbial diversity measured these requirements are currently being met. Further study of the water chemistry, examination of the cobweb-like material using scanning electron microscopy (SEM), and visual inspection of the fuel storage materials are recommended to further assess the mechanisms the microbial materials use for growth and assess the impact, if any, the material has on the underlying aluminum spent fuel. Additional testing and mitigation options include additional monitoring with strategically placed coupons, targeted testing at SRNL, further analysis of the microbiological matter, and removal of the material from the basin.

Berry, C. J.↗

Differences in fine particle chemical composition on clear and cloudy days

Clouds are prevalent and alter fine particulate matter (PM 2.5 ) mass and chemical composition. Cloud-affected satellite retrievals are subject to higher uncertainty and are often removed from data products, hindering quantitative estimates of tropospheric chemical composition during cloudy times. We examine surface PM 2.5 chemical constituent concentrations in the Interagency Monitoring of PROtected Visual Environments (IMPROVE) network in the United States during cloudy and clear-sky times defined using Moderate Resolution Imaging Spectroradiometer (MODIS) cloud flags from 2010 to 2014 with a focus on differences in particle species that affect hygroscopicity and aerosol liquid water (ALW). Cloudy and clear-sky periods exhibit significant differences in PM 2.5 mass and chemical composition that vary regionally and seasonally. In the eastern US, relative humidity alone cannot explain differences in ALW, suggesting that emissions and in situ chemistry related to anthropogenic sources exert determining impacts. An implicit clear-sky bias may hinder efforts to quantitatively understand and improve representation of aerosol–cloud interactions, which remain dominant uncertainties in models.

54 ENVIRONMENTAL SCIENCES↗

Investigation of flow characteristics over missile bodies at supersonic speeds

Three missile body shapes tested at Mach numbers of 1.50, 2.16, and 2.86 with angles of attack up to 30 degrees are described. The flow characteristics for each body shape are examined. The measured aerodynamic forces and moments are presented. The use of flow visualization techniques are described and the results such as vortex effects are discussed.

Barger, R. L.↗

Remarks on the ATMAP Campaigns in November 1981 and May 1982 at Collm (52 Deg N, 15 Deg E)

The results given are based on daily nighttime L. F. wind measurements over Central Europe on three measuring paths at 179, 227, and 272 kHz. Absolute reflection height measurements were carried out for the first time in August 1982 so that values of the months of 1982 and 1983 have been taken for the campaigns in November 1981 and May 1982. The prevailing wind and the semidiurnal tidal wind components are calculated daily. Means of the month or means of parts of a month are formed for climatological investigations. A 24 hour analysis is not possible due to the very different reflection heights during the daytime and nighttime, even with measurements being carried out the whole ay long in the winter season. The critical examination of the choice of the measuring intervals selected is dependent on the visual angle. A wind ield change is observed over Central Europe very often around the 20th of November 1981 this wind field variation being in the core period and leading over to a more stable tidal wind.

Schminder, R.↗

Enhanced rock discrimination using Landsat-5 Thematic Mapper (TM) data

The application of TM data to rock discrimination is discussed. Sixteen specific terrains derived from geologic maps are examined on TM images of the Arabian shield obtained on Apr. 14, 1984; visual enhancement procedures are applied to the images. The rock types observed in the test site are described; the major sedimentary formations in the test area are laterite and sandstone. The data reveal that the layered rocks in the outcrop consist of a variety of metamorphosed volcanics, metamorphosed sediments, and amphibolite, and the intrusive complex is composed of several classes of mafic and acidic rocks.

Blodget, H. W.↗

Distributed-Roughness Effects on Stability and Transition In Swept-Wing Boundary Layers

Boundary-layer stability experiments are conducted in the Arizona State University Unsteady Wind Tunnel on a 45 deg swept airfoil. The pressure distribution and test conditions are designed to suppress Tollmien-Schlichting disturbances and provide crossflow-dominated transition. The surface of the airfoil is finely polished to a near mirror finish. Under these conditions, submicron surface irregularities cause the naturally occurring stationary crossflow waves to grow to nonuniform amplitudes. Spanwise-uniform stationary crossflow disturbances are generated through careful control of the initial conditions with full-span arrays of micron-high roughness elements near the attachment line. Detailed hot-wire measurements are taken to document the stationary crossflow structure and determine growth rates for the total and individual-mode disturbances. Naphthalene flow visualization provides transition location information. Roughness spacing and roughness height are varied to examine the effects on transition location and all amplified wavelengths. The measurements show that roughness spacings that do not contain harmonics equal to the most unstable wavelength as computed by linear stability theory effectively suppress the most unstable mode. Under certain conditions, subcritical roughness spacing delays transition past that of the corresponding smooth surface.

Carrillo, Ruben B., Jr.↗

Effect of field size, head motion, and rotational velocity on roll vection and illusory self-tilt in a tumbling room

The effect of field size, velocity, and visual fixation upon the perception of self-body rotation and tilt was examined in a rotating furnished room. Subjects sat in a stationary chair in the furnished room which could be rotated about the body roll axis. For full-field conditions, complete 360 degrees body rotation (tumbling) was the most common sensation (felt by 80% of subjects). Constant tilt or partial tumbling (less than 360 degrees rotation) occurred more frequently with a small field of view (20 deg). The number of subjects who experienced complete tumbling increased with increases in field of view and room velocity (for velocities between 15 and 30 degrees s-1). The speed of perceived self-rotation relative to room rotation also increased with increasing field of view.

Non-NASA Center↗

Radiological data consolidation and 3D modeling of a building - 15473

A portion of a building at an industrial facility that conducted monazite sands-processing operations in the 1950's under contract to the Atomic Energy Commission (AEC) became contaminated. Subsequently the U.S. Department of Energy designated the facility for remedial action under the Formerly Used Sites Remedial Action Program (FUSRAP). Remedial investigation, remedial actions and post-remediation surveys have been conducted in portions of the building. Radiological data for the interior of the building were compiled, evaluated and presented in a three dimensional (3-D) model (the model) created by AMEC Foster Wheeler in order to identify areas that meet the Record of Decision (ROD) cleanup criteria, and identity areas that may require remedial action or may require additional investigation due to data gaps. The data from different phases of investigation and remediation cover different portions of the building and in some cases overlap. In addition, the data were collected over a period of more than ten years, for different objectives, and thus the instruments and methods for establishing efficiency were not necessarily consistent. The data consolidation process included determining the relative quality of data points to include in the model and the development of rationale associated with assigning a quality level (i.e. ranking) to each data point. The rationale for ranking data quality included, as the primary determining factors, chronological order of the data (most recent was ranked as more reliable), certainty of the sample locations within the building, and analytical data quality. A 3-D model of the building was created using a laser point cloud scan which was then converted into a 3-D design model. Sample locations were then entered into the model and linked with the analytical database to allow display of the radiological results in the model. The visual model allows both strategic and tactical decisions to be made, depending on the level of detail examined. The evaluation process allowed maximum use of the historical data set, rather than requiring older data to be disregarded, and provided at a minimum a qualitative sense of data quality/confidence in the data. The (authors)process also highlights the importance of collecting high quality data from the very beginning with a consistent locational coordinate system, and the need for a good visualization model in order to assess contaminant locations during remedial action or post-remediation surveys.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LossLens: Diagnostics for Machine Learning Through Loss Landscape Visual Analytics

Modern machine learning often relies on optimizing a neural network's parameters using a loss function to learn complex features. Beyond training, examining the loss function with respect to a network's parameters (i.e., as a loss landscape) can reveal insights into the architecture and learning process. While the local structure of the loss landscape surrounding an individual solution can be characterized using a variety of approaches, the global structure of a loss landscape, which includes potentially many local minima corresponding to different solutions, remains far more difficult to conceptualize and visualize. To address this difficulty, we introduce LossLens, a visual analytics framework that explores loss landscapes at multiple scales. LossLens integrates metrics from global and local scales into a comprehensive visual representation, enhancing model diagnostics. Here we demonstrate LossLens through two case studies: visualizing how residual connections influence a ResNet-20, and visualizing how physical parameters influence a physics-informed neural network (PINN) solving a simple convection problem.

97 MATHEMATICS AND COMPUTING↗

Comparative measurement of visual stability in Earth and cosmic space (L-4)

The frequency and the intensity of space motion sickness was reviewed and investigated. Unusual induced-gravity situations, such as rotation, linear acceleration, parallel swinging etc. were investigated as well. Visually-induced motion sensation or distorted perception were evaluated with respect to visual stability by many investigators. These studies are all concerned with the effect of gravity and the induction of motion sickness through human visual perception. Direct investigation under the microgravity situation, such as parabolic flight, Skylab, and Spacelab, was carried out. These studies focused on how human visual stability is established through various sensory afferents in specific gravity conditions. Results from these investigations indicate that sensory mismatch probably plays an important role in space motion sickness. The interaction of visual, vestibular, and somatosensory perception is smoothly coordinated under normal gravitational conditions on the Earth in our daily life. When the cooperation is destroyed or a mismatch occurs among them, motion sickness may develop not only on the Earth but also in microgravity. The latter case may be the cause of space motion sickness or space adaption syndrome. How human beings obtain visual stability even with posture changes on the ground was investigated. Visual stability can be categorized as static or dynamic. Static visual stability is concerned with orientation and dynamic stability is concerned with object motion perception. The perception of visual stability is modified by many other sensations, such as somatosensory, vestibular, and muscle tension. We will mainly focus on modifications by vestibular inputs to visual perception produced by eye movements in microgravity. The Vestibular-Oscular Reflex (VOR) is a well-known characteristic which results from the relationship between eye mobility and vestibular afferent inputs. Eye movements also modify dynamic visual perception, such as perceived object motion velocity. The VOR is constantly simulated under 1-g conditions on Earth. In fact, human beings have been habituated and 'programmed' for orientation (visual stability) in their everyday, 1-g environment. When humans are exposed to a different gravity situation, this programmed behavior must change; that is, it is reprogrammed. This is called habituation or familiarization. We hope to examine how object motion perception is perturbed and subsequently adapted in the microgravity environment. This experiment is focused on the cooperation of visual, vestibular, and somatosensory perception coordination and how it is changed or reduced in space compared to 1-g environment. We will obtain information on the coordination between eye movement and neck muscle activity by using EOG and EMG. We will also collect data from Payload Specialists using a self-diagnostic questionnaire concerned with perceptual abnormality. When each sensory input function and its integration in the higher nervous system are well-characterized, then more effective techniques to control SAS may be developed.

Koga, Kazugo↗

Double-Shell Tank Primary Bottom Visual Inspection Results - 20025

A pressing need for the Double-Shell Tank Integrity Program at Hanford is of the ability to inspect the bottom of the tanks. Though the DSTs' annulus spaces (the space between the internal and external tank walls) have been inspected visually since 1992 and with Ultrasonic Testing (UT) since 1996, inspections of the tank bottoms have been able to be conducted due to limitations of available technology, omitting about 40 percent of the tank surface below the maximum fill level from routine inspection. Visual inspections of the tank annulus have been conducted up to five times in some DSTs and portions of the annulus space for all of the DSTs has been inspected twice with UT. This region includes the walls of the primary tank and secondary liner along with accessible portions of the secondary liner bottom. Due to this lack of technology, the degradation of the primary tank bottom in Tank AY-102 was undetected until the tank leaked into its annulus space, confirmed in 2012. Since that time, WRPS has been working with the nondestructive examination community and the Pacific Northwest National Laboratory, to evaluate potential technologies to conduct these challenging remote inspections. Recent work has included the development, testing, and deployment of several remote visual inspection technologies to observe the condition of the primary tank bottom of the DSTs by leveraging air distribution slots in the refractory pad on which it rests. Robotic solutions to conduct this inspection were developed with a detailed understanding of the physical configuration and operational logistics. Understanding and subsequent communication of these details to vendors within the robotics and nondestructive examination community was a critical component to the successful production of these new tools. Throughout the FY16-FY18 years, vendors from nondestructive examination community were solicited for ideas to meet the tank bottom inspection challenge. Two tank bottom visual inspection solutions were then pursued to meet that challenge. Both tools were successfully deployed at Tank AP-107, and provided valuable visuals, never before obtained from the under tank environment of a double-shell tank. While there are minor opportunities for improvement identified with each system, general outcomes were overwhelmingly positive. Both systems were successfully able to navigate the refractory air slot pattern from the outer edge to the tank center and record video footage. The micro-crawler provided high quality and very stable footage through the air slot pattern, but took longer to deploy into the slots and traverse through them than the alternative system. The push-pull tethered camera was able to navigate all seven of its target air slots in a matter of a few hours, which included deployment, movement between slot entrances, and complete removal of the system from the annulus environment. Through these air slots, new information was gained about the tank bottom and refractory pad condition of tank AP-107, AP-106, AP-108, and AN-102. While some debris was noted in the air slots, including sand, chipped refractory, and construction materials, the refractory was found to be structurally stable and adequately supporting the primary tank bottom through the full diameter of the tank. Primary tank bottom steel exterior was found to be in good condition, free of ongoing or aggressive corrosion conditions. Looking toward the future, robotic access to and visual inspection of refractory air slots and the primary tank bottom steel has now proven viable. Incorporating periodic air slot inspections as a regular practice within the Double-Shell Tank Integrity Program is the next step, allowing trending of any changes in condition. As ultrasonic testing infrastructure was leveraged to complete the initial system deployments described in this report, it makes sense to adopt that same strategy for ongoing periodic examinations and deploy these primary tank bottom inspection tools alongside ultrasonic testing operations. Development of visual inspection tools to evaluate the primary tank bottom region of the double-shell tanks was planned as the first stage of inspection. Continued development of volumetric sensors and incorporation of these inspection tools into Hanford's ongoing Double-Shell Tank Integrity Program are the next steps, seeking to continuously expand understanding of asset integrity and remaining useful life. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Update on Rover Sequencing and Visualization Program

The Rover Sequencing and Visualization Program (RSVP) has been updated. RSVP was reported in Rover Sequencing and Visualization Program (NPO-30845), NASA Tech Briefs, Vol. 29, No. 4 (April 2005), page 38. To recapitulate: The Rover Sequencing and Visualization Program (RSVP) is the software tool to be used in the Mars Exploration Rover (MER) mission for planning rover operations and generating command sequences for accomplishing those operations. RSVP combines three-dimensional (3D) visualization for immersive exploration of the operations area, stereoscopic image display for high-resolution examination of the downlinked imagery, and a sophisticated command-sequence editing tool for analysis and completion of the sequences. RSVP is linked with actual flight code modules for operations rehearsal to provide feedback on the expected behavior of the rover prior to committing to a particular sequence. Playback tools allow for review of both rehearsed rover behavior and downlinked results of actual rover operations. These can be displayed simultaneously for comparison of rehearsed and actual activities for verification. The primary inputs to RSVP are downlink data products from the Operations Storage Server (OSS) and activity plans generated by the science team. The activity plans are high-level goals for the next day s activities. The downlink data products include imagery, terrain models, and telemetered engineering data on rover activities and state. The Rover Sequence Editor (RoSE) component of RSVP performs activity expansion to command sequences, command creation and editing with setting of command parameters, and viewing and management of rover resources. The HyperDrive component of RSVP performs 2D and 3D visualization of the rover s environment, graphical and animated review of rover predicted and telemetered state, and creation and editing of command sequences related to mobility and Instrument Deployment Device (robotic arm) operations. Additionally, RoSE and HyperDrive together evaluate command sequences for potential violations of flight and safety rules. The products of RSVP include command sequences for uplink that are stored in the Distributed Object Manager (DOM) and predicted rover state histories stored in the OSS for comparison and validation of downlinked telemetry. The majority of components comprising RSVP utilize the MER command and activity dictionaries to automatically customize the system for MER activities.

Cooper, Brian↗

Rover Sequencing and Visualization Program

The Rover Sequencing and Visualization Program (RSVP) is the software tool for use in the Mars Exploration Rover (MER) mission for planning rover operations and generating command sequences for accomplishing those operations. RSVP combines three-dimensional (3D) visualization for immersive exploration of the operations area, stereoscopic image display for high-resolution examination of the downlinked imagery, and a sophisticated command-sequence editing tool for analysis and completion of the sequences. RSVP is linked with actual flight-code modules for operations rehearsal to provide feedback on the expected behavior of the rover prior to committing to a particular sequence. Playback tools allow for review of both rehearsed rover behavior and downlinked results of actual rover operations. These can be displayed simultaneously for comparison of rehearsed and actual activities for verification. The primary inputs to RSVP are downlink data products from the Operations Storage Server (OSS) and activity plans generated by the science team. The activity plans are high-level goals for the next day s activities. The downlink data products include imagery, terrain models, and telemetered engineering data on rover activities and state. The Rover Sequence Editor (RoSE) component of RSVP performs activity expansion to command sequences, command creation and editing with setting of command parameters, and viewing and management of rover resources. The HyperDrive component of RSVP performs 2D and 3D visualization of the rover s environment, graphical and animated review of rover-predicted and telemetered state, and creation and editing of command sequences related to mobility and Instrument Deployment Device (IDD) operations. Additionally, RoSE and HyperDrive together evaluate command sequences for potential violations of flight and safety rules. The products of RSVP include command sequences for uplink that are stored in the Distributed Object Manager (DOM) and predicted rover state histories stored in the OSS for comparison and validation of downlinked telemetry. The majority of components comprising RSVP utilize the MER command and activity dictionaries to automatically customize the system for MER activities. Thus, RSVP, being highly data driven, may be tailored to other missions with minimal effort. In addition, RSVP uses a distributed, message-passing architecture to allow multitasking, and collaborative visualization and sequence development by scattered team members.

Cooper, Brian↗

Large High Resolution Displays for Co-Located Collaborative Sensemaking: Display Usage and Territoriality

Large, high-resolution vertical displays carry the potential to increase the accuracy of collaborative sensemaking, given correctly designed visual analytics tools. From an exploratory user study using a fictional textual intelligence analysis task, we investigated how users interact with the display to construct spatial schemas and externalize information, as well as how they establish shared and private territories. We investigated the space management strategies of users partitioned by type of tool philosophy followed (visualization- or text-centric). We classified the types of territorial behavior exhibited in terms of how the users interacted with information on the display (integrated or independent workspaces). Next, we examined how territorial behavior impacted the common ground between the pairs of users. Finally, we offer design suggestions for building future co-located collaborative visual analytics tools specifically for use on large, high-resolution vertical displays.

co-located collaborative sensemaking↗

Magnetophoretic Induction of Root Curvature

The last year of the grant period concerned the consolidation of previous experiments to ascertain that the theoretical premise apply not just to root but also to shoots. In addition, we verified that high gradient magnetic fields do not interfere with regular cellular activities. Previous results have established that: (1) intracellular magnetophoresis is possible; and (2) HGMF lead to root curvature. In order to investigate whether HGMF affect the assembly and/or organization of structural proteins, we examined the arrangement of microtubules in roots exposed to HGMF. The cytoskeletal investigations were performed with fomaldehyde-fixed, nonembedded tissue segments that were cut with a vibratome. Microtubules (MTs) were stained with rat anti-yeast tubulin (YOL 1/34) and DTAF-labeled antibody against rat IgG. Microfilaments (MFs) were visualized by incubation in rhodamine-labeled phalloidin. The distribution and arrangement of both components of the cytoskeleton were examined with a confocal microscope. Measurements of growth rates and graviresponse were done using a video-digitizer. Since HGMF repel diamagnetic substances including starch-filled amyloplasts and most The second aspect of the work includes studies of the effect of cytoskeletal inhibitors on MTs and MFs. The analysis of the effect of micotubular inhibitors on the auxin transport in roots showed that there is very little effect of MT-depolymerizing or stabilizing drugs on auxin transport. This is in line with observations that application of such drugs is not immediately affecting the graviresponsiveness of roots.

Hasenstein, Karl H.↗