Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Validity of trace element cosmothermometer

A reply is made to previous criticisms of the claim that the range of accretion of ordinary chondrites can be narrowed to 500-420 K (from 560-405 K) using volatile metals as cosmothermometers. Questions concerning uncertainties in vapor pressure data, entropy of mixing, methods of analysis, uncertainties in condensation curves, metamorphic transport, alloy formation, condensation of Tl, condensation of In, and concordance with other thermometers (FeO contents of silicates) are addressed. It is concluded that the original claim is valid.

Anders, E.↗

Semiconductor Grade, Solar Silicon Purification Project

A low cost by-product, SiF4, is reacted with mg silicon to form SiF2 gas which is polymerized. The (SiF2)x polymer is heated forming volatile SixFy homologues which disproportionate on a silicon particle bed forming silicon and SiF4. The silicon analysis procedure relied heavily on mass spectroscopic and emission spectroscopic analysis. These analyses demonstrated that major purification had occured and some samples were indistinguishable from semiconductor grade silicon (except possibly for phosphorus). However, electrical analysis via crystal growth reveal that the product contains compensated phosphorus and boron.

Ingle, W. M.↗

The Geologic History of Mars: An Astrobiology Perspective

Fourteen SNC meteorites contain information which must be incorporated with recent spaceflight data for developing Mars' geologic history. SNCs have crystallization ages of 4500 to 160 m.y. Tle oldest meteorite ALH84001 contains information on the Noachian period of Mars' history. There are no meteorites from the Hesperian period and the remaining 13 meteorites fall into two age groups within the Amazonian: The nakhlites around 1300 m.y. and the shergottites between 800-160 m.y. Oxygen isotopic analysis of Martian samples shows two distinct O2 reservoirs throughout Martian history indicating late additions of volatiles and a lack of plate tectonics prior to 3.9 Gy. Evidence for percolation of aqueous brines through impact-produced fractures in the rocky surface is contained in the 3.9 Gy-old ALH84001 carbonate deposits. These carbonates precipitated at approx. 100 C. At this time life had already evolved on Earth. Early Mars could have hosted life similar to the bacteria that inhabited early Earth. Potential microorganisms could have been transported into fractures by carbonate-bearing waters and their remains could have become incorporated into the precipitated carbonate. Since Mars had a weak magnetic field at this time, it can be hypothesized that some of the Martian microorganisms may have been similar to terrestrial magnetotactic bacteria. Over geologic time episodic cratering, and tectonic events have occurred on Mars along with the periodic release of subsurface waters which may have produced clays within SNC meteorites. The geochemical data contained within SNC meteorites complements previous observational data and the recent Mars Global Surveyor data to provide a geological and environmental history which spans almost the entire lifespan on Mars. One of the outstanding features of this model is the possible creation of an early (about 4 Gy) volatile reservoir distinct from the outgassed Mars volatiles, and the persistence of this reservoir throughout most, if not all of subsequent Mars' history. Within the framework of this history a potential scenario for a possible record of living organisms is provided by suggestive structures and organic signatures trapped within secondary mineral deposits and alteration features of some SNC meteorites. Tracing the differences in oxygen isotopic compositions within Martian components allows us to gain insight in the history of Mars.

Gibson, Everett K.↗

The Search for Water and Other Volatiles in Martian Surface Materials: The Thermal Evolved Gas Analyzer (TEGA)

Volatile-bearing minerals and phases (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, sulfates, palagonites, glasses) may be important components of the Martian regolith. However, essentially no information exists on the mineralogical composition of volatile-bearing phases in the regolith. The Thermal Evolved Gas Analyzer (TEGA), which was part of the Mars Polar Lander payload, was to determine the abundances of two of the most important volatile compounds (i.e., water and carbon dioxide) in the martian soil and to identify the minerals or phases that harbor these volatiles. The TEGA instrument was composed of a differential scanning calorimeter (DSC) interfaced with evolved gas analysis (EGA). The EGA consisted of a Herriott cell of a tunable-diode laser (TDL) spectrometer that determines CO2 and H2O abundances. The sample chamber was to operate at about 100 mbar (-76 torr) with a N2 carrier gas flow of 0.4 sccm. Specifications of TEGA are described in detail elsewhere in this volume.

Ming, D. W.↗

A New Time-dependent Model for the Martian Radiation Environment

Manned space activities have been until present time limited to the near-Earth environment, most of them to low Earth orbit (LEO) scenarios, with only some of the Apollo missions targeted to the Moon. In current times most human exploration and development of space (HEDS) activities are related to the development of the International Space Station (ISS), and therefore take place in the LEO environment. A natural extension of HEDS activities will be going beyond LEO, and reach asteroids, Mars, Jupiter, Saturn, the Kuiper belt and the outskirts of the Solar System. Such long journeys onboard spacecraft outside the protective umbrella of the geomagnetic field will require higher levels of protection from the radiation environment found in the deep space for both astronauts and equipment. So, it is important to have available a tool for radiation shielding which takes into account the radiation environments found all along the interplanetary space and at the different bodies encountered in the Solar System. Moreover, the radiation protection is one of the two NASA highest concerns and priorities. A tool integrating different radiation environments with shielding computation techniques especially tailored for deep space mission scenario is instrumental in view of this exigency. In view of manned missions targeted to Mars, for which radiation exposure is one of the greatest problems and challenges to be tackled, it is of fundamental importance to have available a tool which allows to know which are the particle flux and spectra at any time at any point of the Martian surface. With this goal in mind, a new model for the radiation environment to be found on the planet Mars due to Galactic Cosmic Rays (GCR) has been developed. Solar modulated primary particles rescaled for Mars conditions are transported within the Martian atmosphere, with temporal properties modeled with variable timescales, down to the surface, with altitude and backscattering patterns taken into account. The tool allows analysis for manned Mars landing missions, as well as planetary science studies, e.g. subsurface water and volatile inventory studies. This Mars environmental model is available through the SIREST website, a project of NASA Langley Research Center.

G De Angelis↗

Flight Data Update on Long-Term Compound Stability in Dual Sorbent Tubes

Dual Sorbent Tubes (DSTs) are currently the primary method for collecting volatile organic compounds in the cabin air of the International Space Station (ISS). Data from groundbased analysis of these archival air samplers provide a major component of the assessment of ISS air quality by the NASA toxicologist. At the 2005 ICES conference data from the positive control DSTs, returned on Soyuz 7S and 8S, were presented. Positive control tubes are dosed, preflight, with known concentrations of representative contaminant compounds and they are launched to ISS in the DST kit as trip controls. Upon return of the DST kit to the ground, results from analysis of the trip (positive) and laboratory control tubes are used to determine the recoveries: concentration of dosed compounds retained in the tube. Results from positive controls, returned on 7S and 8S showed substantial losses of some compounds dosed into the tubes 156 to 240 days prior to the analysis. Low recoveries are expected for spacecraft air contaminants with similar properties to the poorly recovered dosed compounds. It was shown that compound losses in the control tubes were consistent, which led to the generation of acceptable correction factors for spacecraft air contaminants. Correction factors decrease the accuracy of derived compound concentrations and substantial error could arise under some conditions. An investigation into the mechanism for compound loss is necessary before design modifications can be implemented to improve the DST performance. This paper will update results from the DSTs returned on Soyuz 9S and 10S missions during the latter part of 2005. The data acquired from these returned DSTs will be compared to the 7S and 8S data presented last year. Discussion will focus on the reliability of correction factors and identify any trends in the data. This paper will describe the experimental design and plans to identify the compound loss mechanism.

James, John T.↗

A Novel Approach to Detect Accelerated Aged and Surface-Mediated Degradation in Explosives by UPLC-ESI-MS.

A new approach was created for studying energetic material degradation. This approach involved detecting and tentatively identifying non-volatile chemical species by liquid chromatography-mass spectrometry (LC-MS) with multivariate statistical data analysis that form as the CL-20 energetic material thermally degraded. Multivariate data analysis showed clear separation and clustering of samples based on sample group: either pristine or aged material. Further analysis showed counter-clockwise trends in the principal components analysis (PCA), a type of multivariate data analysis, Scores plots. These trends may indicate that there was a discrete shift in the chemical markers as the went from pristine to aged material, and then again when the aged CL-20 mixed with a potentially incompatible material was thermally aged for 4, 6, or 9 months. This new approach to studying energetic material degradation should provide greater knowledge of potential degradation markers in these materials.

36 MATERIALS SCIENCE↗

Bioremediation Retrospective: DOE Experiences and Lessons Learned – 26131

The U.S. Department of Energy (DOE) has implemented bioremediation strategies for chlorinated volatile organic compounds (cVOCs) for more than three decades across multiple contaminated groundwater sites. A retrospective analysis conducted by the Savannah River National Laboratory (SRNL) and collaborating field sites evaluated the design, performance, and outcomes of bioremediation projects at DOE’s Savannah River, Hanford, Idaho, Mound, and Pinellas sites. This retrospective was based on a series of case studies, leveraging historical documentation and site interviews. Technical approaches employed at the various sites were explored, including active bioremediation, enhanced attenuation (EA), and monitored natural attenuation, with specific sub-sections discussing anaerobic, aerobic, and combined anaerobic-aerobic strategies. Each case study includes detailed descriptions of the site-specific conditions, deployment strategies, regulatory considerations, metrics, and performance. Key findings include general cost savings compared to traditional remedies such as pump and treat (P&T), significant success in applying enhanced attenuation to transition remedies toward a passive site management strategy, and documentation of robust subsurface microbial communities at most sites limiting the need for bioaugmentation. Challenges highlighted in the study include underperformance due to poor amendment delivery in low-permeability zones and unfavorable biogeochemical conditions, emphasizing the importance of site-specific designs. Cost analysis across DOE sites suggests bioremediation may offer long-term economic benefits. The retrospective study underscores valuable lessons that can help inform current and future bioremediation efforts.

Newby, Deborah T. [Savannah River National Laborat↗

Long term isothermal aging and thermal analysis of N-CYCAP polyimides

The N-CYCAP polyimides utilize a (2,2) paracyclophane endcap that polymerizes and does not generate volatile gases during the cure process. These polyimides have both high glass temperatures (390 C) and an onset of decomposition in air of 560 C. Thermal oxidative stability (TOS) weight loss studies show that replacing 25 percent by weight of the paraphenylene diamine in the polymer backbone with metaphenylene diamine improves the weight loss characteristics. N-CYCAP neat resin samples performed better than PMR-II-50 when exposed at 343 and 371 C in air for up to 1000 hours. Preliminary composite studies show that both PMR-II-50 and N-CYCAP have better thermal stability when fabricated on T-40R. Higher isothermal aging temperatures of longer aging times are needed to determine the differences in TOS between composite samples of PMR-II-50 and N-CYCAP polyimides.

Sutter, James K.↗

Vapor-Particle Separation Using Microporous Metallic Membrane in Crossflow Filtration

Simultaneous separation of vapor and particles in industrial processes could be a key step toward manufacturing of high-quality goods. The separation is critical for successful measurement of volatile or semi-volatile aerosol particles, which no reliable technique exists. We have developed a technique for separation of vapor and particles simultaneously using a specialty microporous metallic membrane. The separator allows the thermally denuded particles traverse straight through the membrane tube, while the vapor molecules permeate through the membrane, separate from the particles and are removed subsequently. The separation technique virtually eliminates the possibility of contamination by vapor re- condensation. We tested the prototype of the vapor-particle separator (VPS) using aerosols prepared from sodium chloride to represent non-volatile aerosols. Chemical like dioctyl phthalate was chosen to represent volatile particles. The test aerosol particles were generated by an atomizer followed by a tandem differential mobility analyser to produce a stream of monodisperse particles in the size range of 10 to 100 nm. In real world particles, we tested the VPS using diesel engine particles that is a mixture of complex chemical composition. Number concentration of the nonvolatile particles reduced as the temperature increased, but the mode diameter of the aerosol population remained unchanged. Number concentration of the volatile particles was also reduced as the temperature increased, but their mode diameters became smaller as particles shrunk in diameter. Differences in the thermal behaviour of the particles were attributed to its transition energy barrier and evaporation rate. Mass balance analysis suggests the separation of vapor and test particles was reasonably complete. Thus, we conclude the VPS could provide an effective means for quantitative characterization of aerosol volatility and separation of vapors from particles.

aerosol↗

Observations on vapor pressure in SPR caverns : sources.

The oil of the Strategic Petroleum Reserve (SPR) represents a national response to any potential emergency or intentional restriction of crude oil supply to this country, and conforms to International Agreements to maintain such a reserve. As assurance this reserve oil will be available in a timely manner should a restriction in supply occur, the oil of the reserve must meet certain transportation criteria. The transportation criteria require that the oil does not evolve dangerous gas, either explosive or toxic, while in the process of transport to, or storage at, the destination facility. This requirement can be a challenge because the stored oil can acquire dissolved gases while in the SPR. There have been a series of reports analyzing in exceptional detail the reasons for the increases, or regains, in gas content; however, there remains some uncertainty in these explanations and an inability to predict why the regains occur. Where the regains are prohibitive and exceed the criteria, the oil must undergo degasification, where excess portions of the volatile gas are removed. There are only two known sources of gas regain, one is the salt dome formation itself which may contain gas inclusions from which gas can be released during oil processing or storage, and the second is increases of the gases release by the volatile components of the crude oil itself during storage, especially if the stored oil undergoes heating or is subject to biological generation processes. In this work, the earlier analyses are reexamined and significant alterations in conclusions are proposed. The alterations are based on how the fluid exchanges of brine and oil uptake gas released from domal salt during solutioning, and thereafter, during further exchanges of fluids. Transparency of the brine/oil interface and the transfer of gas across this interface remains an important unanswered question. The contribution from creep induced damage releasing gas from the salt surrounding the cavern is considered through computations using the Multimechanism Deformation Coupled Fracture (MDCF) model, suggesting a relative minor, but potentially significant, contribution to the regain process. Apparently, gains in gas content can be generated from the oil itself during storage because the salt dome has been heated by the geothermal gradient of the earth. The heated domal salt transfers heat to the oil stored in the caverns and thereby increases the gas released by the volatile components and raises the boiling point pressure of the oil. The process is essentially a variation on the fractionation of oil, where each of the discrete components of the oil have a discrete temperature range over which that component can be volatized and removed from the remaining components. The most volatile components are methane and ethane, the shortest chain hydrocarbons. Since this fractionation is a fundamental aspect of oil behavior, the volatile component can be removed by degassing, potentially prohibiting the evolution of gas at or below the temperature of the degas process. While this process is well understood, the ability to describe the results of degassing and subsequent regain is not. Trends are not well defined for original gas content, regain, and prescribed effects of degassing. As a result, prediction of cavern response is difficult. As a consequence of this current analysis, it is suggested that solutioning brine of the final fluid exchange of a just completed cavern, immediately prior to the first oil filling, should be analyzed for gas content using existing analysis techniques. This would add important information and clarification to the regain process. It is also proposed that the quantity of volatile components, such as methane, be determined before and after any degasification operation.

02 PETROLEUM↗

The TESS-Keck Survey. II. An Ultra-short-period Rocky Planet and Its Siblings Transiting the Galactic Thick-disk Star TOI-561

We report the discovery of TOI-561, a multiplanet system in the galactic thick disk that contains a rocky, ultra-short-period planet. This bright (V = 10.2) star hosts three small transiting planets identified in photometry from the NASA TESS mission: TOI-561 b (TOI-561.02, P = 0.44 days, R {sub p} = 1.45 ± 0.11 R {sub ⊕}), c (TOI-561.01, P = 10.8 days, R {sub p} = 2.90 ± 0.13 R {sub ⊕}), and d (TOI-561.03, P = 16.3 days, R {sub p} = 2.32 ± 0.16 R {sub ⊕}). The star is chemically ([Fe/H] = −0.41 ± 0.05, [α/Fe] = +0.23 ± 0.05) and kinematically consistent with the galactic thick-disk population, making TOI-561 one of the oldest (10 ± 3 Gyr) and most metal-poor planetary systems discovered yet. We dynamically confirm planets b and c with radial velocities from the W. M. Keck Observatory High Resolution Echelle Spectrometer. Planet b has a mass and density of 3.2 ± 0.8 M {sub ⊕} and 5.5{sub −1.6}{sup +2.0} g cm{sup −3}, consistent with a rocky composition. Its lower-than-average density is consistent with an iron-poor composition, although an Earth-like iron-to-silicates ratio is not ruled out. Planet c is 7.0 ± 2.3 M {sub ⊕} and 1.6 ± 0.6 g cm{sup −3}, consistent with an interior rocky core overlaid with a low-mass volatile envelope. Several attributes of the photometry for planet d (which we did not detect dynamically) complicate the analysis, but we vet the planet with high-contrast imaging, ground-based photometric follow-up, and radial velocities. TOI-561 b is the first rocky world around a galactic thick-disk star confirmed with radial velocities and one of the best rocky planets for thermal emission studies.

47 OTHER INSTRUMENTATION↗

Cross-Correlation Asymmetries and Causal Relationships between Stock and Market Risk

We study historical correlations and lead-lag relationships between individual stock risk (volatility of daily stock returns) and market risk (volatility of daily returns of a market-representative portfolio) in the US stock market. We consider the cross-correlation functions averaged over all stocks, using 71 stock prices from the Standard & Poor’s 500 index for 1994–2013. We focus on the behavior of the cross-correlations at the times of financial crises with significant jumps of market volatility. The observed historical dynamics showed that the dependence between the risks was almost linear during the US stock market downturn of 2002 and after the US housing bubble in 2007, remaining at that level until 2013. Moreover, the averaged cross-correlation function often had an asymmetric shape with respect to zero lag in the periods of high correlation. We develop the analysis by the application of the linear response formalism to study underlying causal relations. The calculated response functions suggest the presence of characteristic regimes near financial crashes, when the volatility of an individual stock follows the market volatility and vice versa.

99 GENERAL AND MISCELLANEOUS↗

Heating-Induced Transformations of Atmospheric Particles: Environmental Transmission Electron Microscopy Study

Environmental transmission electron microscopy was employed to probe transformations in the size, morphology, and composition of individual atmospheric particles as a function of temperature. Two different heating devices were used and calibrated in this work: a furnace heater and a Micro Electro Mechanical System heater. The temperature calibration utilized sublimation temperatures of NaCl, glucose, and ammonium sulfate particles, and the melting temperature of tin. Volatilization of Suwanee River Fulvic Acid was further used to validate the calibration up to 800 °C. The calibrated furnace holder was used to examine both laboratory generated secondary organic aerosol particles and field-collected atmospheric particles. Chemical analysis by scanning transmission X-ray microscopy and near edge fine structure spectroscopy of the organic particles at different heating steps showed that above 300 °C particle volatilization was accompanied by charring. These methods were then applied to ambient particles collected in the central Amazon region. Distinct categories of particles differed in their volatilization response to heating. Spherical, more viscous particles lost less volume during heating than particles that spread on the imaging substrate during impaction, due to either being liquid upon impaction or lower viscosity. This methodology illustrates a new analytical approach to accurately measure the volume fraction remaining for individually tracked atmospheric particles at elevated temperatures.

Veghte, Daniel P.↗

A field gas chromatograph using technology developed for solar system exploration

Trace gas analysis is an integral part of biospheric studies. Analytical instruments, primarily gas chromatographs (GC), are capable of measuring gases and volatiles to the ppb-level in real time. Trace gases significant in the study of biocycles include nitrous oxide, hydrogen sulfide, other nitrogen and sulfur species, as well as methane and ethylene. The concept of a field gas chromatograph is derived from technology being pursued in the design of ultra-compact instruments for solar system exploration. The instrument breadboard incorporates the specialized porous column packings and the highly sensitive metastable ionization detector developed by the Solar System Exploration Office. These parts ensure a broad capability for which the analysis of ambient N2O is one example. A commercial, portable gas chromatograph is currently being extensively modified to incorporate analytical concepts and components derived from flight GC technology. Data storage devices suitable for field use are presently being studied.

Woeller, F. H.↗

The Influence of Mineralogy on Recovering Organic Acids from Mars Analogue Materials Using the One-Pot Derivatization Experiment on the Sample Analysis at Mars(SAM) Instrument Suite

The search for complex organic molecules on Mars, including important biomolecules such as amino acids and carboxylic acids, will require a chemical extraction and a derivatization step to transform these organic compounds into species that are sufficiently volatile to be detected by gas chromatography mass spectrometry (GCMS). We have developed a ''one-pot'' extraction and chemical derivatization protocol using N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and dimethylformamide (DMF) for the Sample Analysis at Mars (SAM) experiment instrument suite on NASA's the Mars Science Laboratory (MSL) mission. The temperature and duration of the derivatization reaction, pre-concentration of chemical derivatives, and gas chromatographic separation parameters have been optimized under SAM instrument design constraints. MTBSTFA/DMF extraction and derivatization at 300 1C for several minutes of a variety of terrestrial Mars analog materials facilitated the detection of amino acids and carboxylic acids in a surface soil sample collected from the Atacama Desert and a carbonate-rich stromatolite sample from Svalbard. However, the rapid reaction of MTBSTFA with water in several analog materials that contained high abundances of hydrated minerals, and the possible deactivation of derivatized compounds by iron oxides, as detected by XRD/XRF using the CheMin field unit Terra, proved to be highly problematic for the direct extraction of organics using MTBSTFA. The combination of pyrolysis and two different wet-chemical derivatization methods employed by SAM should enable a wide range of organic compounds to be detected by GCMS if present on Mars.

MSL↗

Preliminary Radiation Analysis of the Total Ionizing Dose for the Resource Prospector Mission

NASA's Resource Prospector (RP) is a collaborative project between multiple centers and institutions to search for volatiles at the polar regions of the Moon as a potential resource for oxygen and propellant production. The mission is rated Class D and will be the first In-Situ Resource Utilization (ISRU) demonstration on the lunar surface and at the lunar poles. Given that this mission is rated Class D, the project is considering using commercial off the shelf (COTS) electronics parts to reduce cost. However, COTS parts can be more susceptible to space radiation than typical aerospace electronic parts and carry some additional risk. Thus, prior to parts selection, having a better understanding of the radiation environment can assist designers in the parts selection process. The focus of this paper is to provide a preliminary analysis of the radiation environment from launch, through landing on the surface, and some surface stay as an initial step in determining worst case mission doses to assist designers in screening out electronic parts that would not meet the potential dose levels experienced on this mission.

Rojdev, Kristina↗

Analysis of countercurrent membrane vapor extraction of a dilute aqueous biosolute

Removal of dilute bioproducts from fermenter broths is a major challenge both to avoid microbe inhibition and to recover solutes economically without water loss. We analyze a proposed new process, membrane vapor extraction (MVE), where semi-volatile dilute aqueous solutes vaporize at the upstream side of an omniphobic, microporous membrane and dissolve into a nonpolar solvent highly favorable to the solutes but not to water. A new membrane-process analysis is outlined and applied to the countercurrent recovery of 2 wt % aqueous butanol by a prototype solvent (dodecane) at 40°C. Thermodynamic phase equilibria, pioneered by the Prausnitz school, are crucial to MVE process design. Over 90% of the feed butanol is recovered with essentially no water loss giving a separation factor of over 1000. Energy requirements in MVE are low. In this study, our design calculations demonstrate that MVE is a viable separation process to remove and recover dilute aqueous biosolutes.

mass-transfer resistance↗