Evaporative chilling systems and methods using a selective transfer membrane

Compact membrane evaporative chillers, methods for cooling a process fluid (e.g., air) using a compact membrane evaporative chiller, and air conditioning systems and methods that include a compact membrane evaporative chiller are disclosed herein. Compact membrane evaporative chillers as disclosed herein can advantageously reduce or eliminate power consumption needed to circulate a working fluid.

Johnson, Brian↗

A buffering heat exchanger/thermal energy storage system for desalination applications

A buffering heat exchanger/thermal energy storage (BHXTES) system was designed using a fast-response phase-change material/graphite foam (PCM/GF) medium for desalination and potentially other industrial applications. Unlike a store-now-and-use-later TES system, this study focused on developing a dynamically balanced, continuously used, system that optimized three functions. A lab-scale prototype was designed and fabricated with a PureTemp 151/GF storage medium. The experimental data showed excellent thermal performance repeatability indicating minimal effects of PCM expansion and contraction on the GF as well as negligible PCM redistribution effects. The experimental data also served as a validation of the numerical model of the BHXTES system, after which optimization of the BHXTES system was conducted through numerical simulations for both PureTemp 151/GF and solar salt/GF as the storage medium. The results show that, with a Therminol 55 heat transfer fluid, continuous operation of the system can be realized with a solar energy source through cycles of 8-h changing for desalination and energy storage with the supplied heat followed by 16-h discharging for desalination with the stored energy. As a result, the working fluid outlet temperatures are generally in the ranges of approximately 128–160 °C for a PureTemp 151/GF medium and 198–220 °C for a solar salt/GF medium.

Buffering↗

Energy efficient fluid powered linear actuator with variable area

Hydraulic actuation systems having variable displacements and energy recovery capabilities include cylinders with pistons disposed inside of barrels. When operating in energy consuming modes, high speed valves pressurize extension chambers or retraction chambers to provide enough force to meet or counteract an opposite load force. When operating in energy recovery modes, high speed valves return a working fluid from extension chambers or retraction chambers, which are pressurized by a load, to an accumulator for later use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Melting and Freezing/Solidification and the Associated Effects on Heat Transfer

Phase change (solid/liquid or liquid/vapor) is a process that enables a large heat transfer capacity for a broad range of engineering applications, such as steam generators, condensers, thermal energy storage, thermosyphons, and heat pipes. Water has been the most usable phase-change cooling medium. Advanced applications are proposing alkali metals (e.g., sodium, potassium, lithium) to increase the total heat transfer rate for moderate and high-temperature applications. Sodium and potassium have the advantage of relatively low melting temperatures (98 and 64°C, respectively) make them suitable for high-temperature applications (700–1100 K). At too high of temperatures (above 1200 K), lithium is an excellent choice as a working fluid because of its high latent heat vaporization and high-surface tension. The low vapor pressure of alkali metals makes them candidates for closed spaces applications, such as thermosyphons and heat pipes. Lithium has the lowest vapor pressure than potassium and sodium, which can work at a much higher temperature without over-pressurizing the container.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study and development of an air conditioning system operating on a magnetic heat pump cycle (design and testing of flow directors)

This report describes the fabrication, design of flow director, fluid flow direction analysis and testing of flow director of a magnetic heat pump. The objectives of the project are: (1) to fabricate a demonstration magnetic heat pump prototype with flow directors installed; and (2) analysis and testing of flow director and to make sure working fluid loops flow through correct directions with minor mixing. The prototype was fabricated and tested at the Development Testing Laboratory of Kennedy Space Center. The magnetic heat pump uses rear earth metal plates rotate in and out of a magnetic field in a clear plastic housing with water flowing through the rotor plates to provide temperature lift. Obtaining the proper water flow direction has been a problem. Flow directors were installed as flow barriers between separating point of two parallel loops. Function of flow directors were proven to be excellent both analytically and experimentally.

Wang, Pao-Lien↗

A comparison of experimental and theoretical results for rotordynamic coefficients of four annular gas seals

The test facility and initial test program developed to experimentally measure the fluid forces induced by annular gas seals is described. A comparison of theoretically predicted and experimentally obtained data for smooth and honeycomb seals is provided. And a comparison of experimental data from the tests of three smooth-rotor/smooth-stator seals is provided. The leakage of the working fluid through the seal, the pressure gradient along the seal length, entrance pressure-loss data, and rotordynamic coefficients provide a basis for comparison. A short discussion on seal theory is included, and various rotordynamic coefficient identification schemes are described.

Childs, D. W.↗

Energy efficient fluid powered linear actuator with variable area and concentric chambers

Hydraulic actuation systems having concentric chambers, variable displacements and energy recovery capabilities include cylinders with pistons disposed inside of barrels. When operating in energy consuming modes, high speed valves pressurize extension chambers or retraction chambers to provide enough force to meet or counteract an opposite load force. When operating in energy recovery modes, high speed valves return a working fluid from extension chambers or retraction chambers, which are pressurized by a load, to an accumulator for later use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstration of MSR salt property database operation with a reactor analysis tool

Successful modeling and simulation of molten salt reactors (MSRs) requires quality thermodynamic and thermophysical data for the working fluid. A goal of the Molten Salt Reactor Campaign is to develop a quality-controlled database of these properties that will be available for a multitude of different salt types. Furthermore, properties shall be defined in a standardized format that can then be used by reactor modeling and analysis tools. This report details work done to develop an approach for integrating salt properties into a MSR analysis tool. This activity required defining a format for thermophysical properties that could be produced from salt data delivered by Argonne National Laboratory (ANL) and which could be read into a reactor analysis tool. The reactor analysis tool used for this activity was the Consortium for Advanced Simulation of Light Water Reactors-developed tool, VERA. The changes implemented in VERA to accept the thermophysical properties file are discussed and tested and the process of reading thermophysical properties into VERA for a MSR simulation is demonstrated. In addition to being able to get fluid properties into the simulation tool, it is also necessary that a process exists for adding new salt data to the salt database. The NEAMS Workbench is being expanded with a new package called ThermPhys that will provide a user interface for adding new salts to the database while performing input validation and ensuring data quality.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Magnetohydrodynamics Accelerator Research Into Advanced Hypersonics (MARIAH)

This report documents the activities, results, conclusions and recommendations of the Magnetohydrodynamics Accelerator Research Into Advanced Hypersonics (MARIAH) Project in which the use of magnetohydrodynamics (MHD) technology is investigated for its applicability to augment hypersonic wind tunnels. The long range objective of this investigation is to advance the development of ground test facilities to support the development of hypervelocity flight vehicles. The MHD accelerator adds kinetic energy directly to the wind tunnel working fluid, thereby increasing its Mach number to hypervelocity levels. Several techniques for MHD augmentation, as well as other physical characteristics of the process are studied to enhance the overall performance of hypersonic wind tunnel design. Specific recommendations are presented to improve the effectiveness of ground test facilities. The work contained herein builds on nearly four decades of research and experimentation by the aeronautics ground test and evaluation community, both foreign and domestic.

Micheletti, David A.↗

Magnetohydrodynamics Accelerator Research into Advanced Hypersonics (MARIAH)

This report documents the activities, results, conclusions and recommendations of the Magnetohydrodynamics Accelerator Research Into Advanced Hypersonics (MARIAH) Project in which the use of magnetohydrodynamics (MHD) technology is investigated for its applicability to augment hypersonic wind tunnels. The long range objective of this investigation is to advance the development of ground test facilities to support the development of hypervelocity flight vehicles. The MHD accelerator adds kinetic energy directly to the wind tunnel working fluid, thereby increasing its Mach number to hypervelocity levels. Several techniques for MHD augmentation, as well as other physical characteristics of the process are studied to enhance the overall performance of hypersonic wind tunnel design. Specific recommendations are presented to improve the effectiveness of ground test facilities. The work contained herein builds on nearly four decades of research and experimentation by the aeronautics ground test and evaluation community, both foreign and domestic.

Baughman, Jack A.↗

MELCOR/CONTAIN LMR Implementation Report. FY14 Progress

This report describes the preliminary implementation of the sodium thermophysical properties and the design documentation for the sodium models of CONTAIN-LMR to be implemented into MELCOR 2.1. In the past year, the implementation included two separate sodium properties from two different sources. The first source is based on the previous work done by Idaho National Laboratory by modifying MELCOR to include liquid lithium equation of state as a working fluid to model the nuclear fusion safety research. To minimize the impact to MELCOR, the implementation of the fusion safety database (FSD) was done by utilizing the detection of the data input file as a way to invoking the FSD. The FSD methodology has been adapted currently for this work, but it may subject modification as the project continues. The second source uses properties generated for the SIMMER code. Preliminary testing and results from this implementation of sodium properties are given. In this year, the design document for the CONTAIN-LMR sodium models, such as the two condensable option, sodium spray fire, and sodium pool fire is being developed. This design document is intended to serve as a guide for the MELCOR implementation. In addition, CONTAIN-LMR code used was based on the earlier version of CONTAIN code. Many physical models that were developed since this early version of CONTAIN may not be captured by the code. Although CONTAIN 2, which represents the latest development of CONTAIN, contains some sodium specific models, which are not complete, the utilizing CONTAIN 2 with all sodium models implemented from CONTAIN-LMR as a comparison code for MELCOR should be done. This implementation should be completed in early next year, while sodium models from CONTAIN-LMR are being integrated into MELCOR. For testing, CONTAIN decks have been developed for verification and validation use.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Analysis of the Transonic Dynamics Tunnel Using FUN3D

This paper presents results from an explanatory two-year effort of applying Computational Fluid Dynamics (CFD) to analyze the empty-tunnel flow in the NASA Langley Research Center Transonic Dynamics Tunnel (TDT). The TDT is a continuous-flow, closed circuit, 16- x 16-foot slotted-test-section wind tunnel, with capabilities to use air or heavy gas as a working fluid. In this study, experimental data acquired in the empty tunnel using the R-134a test medium was used to calibrate the computational data. The experimental calibration data includes wall pressures, boundary-layer profiles, and the tunnel centerline Mach number profiles. Subsonic and supersonic flow regimes were considered, focusing on Mach 0.5, 0.7 and Mach 1.1 in the TDT test section. This study discusses the computational domain, boundary conditions, and initial conditions selected in the resulting steady-state analyses using NASA's FUN3D CFD software.

97 MATHEMATICS AND COMPUTING↗

Computational Analysis of the Transonic Dynamics Tunnel Using FUN3D

This paper presents results from an exploratory two-year effort of applying Computational Fluid Dynamics (CFD) to analyze the empty-tunnel flow in the NASA Langley Research Center Transonic Dynamics Tunnel (TDT). The TDT is a continuous-flow, closed circuit, 16- x 16-foot slotted-test-section wind tunnel, with capabilities to use air or heavy gas as a working fluid. In this study, experimental data acquired in the empty tunnel using the R-134a test medium was used to calibrate the computational data. The experimental calibration data includes wall pressures, boundary-layer profiles, and the tunnel centerline Mach number profiles. Subsonic and supersonic flow regimes were considered, focusing on Mach 0.5, 0.7 and Mach 1.1 in the TDT test section. This study discusses the computational domain, boundary conditions, and initial conditions selected and the resulting steady-state analyses using NASA's FUN3D CFD software.

Chwalowski, Pawel↗

The cost savings potential of controlling solar thermal collectors with storage for time-of-use electricity rates

Homes and commercial buildings account for roughly 40% of U.S. energy consumption. A significant portion of this energy consumption, and therefore utility cost, comes from domestic hot-water use. Solar collectors such as flat plate collectors, evacuated tubes, and combined photovoltaic/thermal panels, are renewable options that collect thermal energy and could help reduce utility costs. Hot water is generated by pumping a working fluid through the solar collector, where the fluid captures thermal energy via absorbed solar radiation incident on the collector surface. The collection of heat coincides with the availability of solar radiation, but the best time to use this thermal energy depends on the utility rate at a given time, which often changes throughout the day. In this work, we implement and simulate a control strategy using Transient System Simulation Tool (TRNSYS) that reduces utility costs by controlling when the system stores and uses thermal energy based on solar availability and time-of-use electricity rates. Our modeled results show that the control strategy can reduce utility costs associated with using hot water between 3% and 30%. Here, we also show how the on-peak utility rates, the size and type of the solar collectors, and the location's climate impact the results.

14 SOLAR ENERGY↗

Diesel Engine Waste Heat Driven Absorption Heat Pumps for ECU Applications in Defense Installations

A thermally activated absorption heat pump suitable for use in naval expeditionary Environmental Control Units, as well as residential space-conditioning, is developed. Waste heat characteristic of the exhaust stream from a diesel engine GenSet is used to drive an absorption cycle to provide cooling. The heat source is coupled to the heat pump using an intermediate fluid loop for flexible deployment. With minor modifications, the heat pump could also provide heating at high coefficients of performance, resulting in versatile functionality. This technology capitalizes on heat and mass transfer enhancement possible in microscale passages to provide a compact architecture for the components and the overall system. The working fluid pair with zero Global Warming Potential is contained within this assembly, reducing fluid inventories significantly over conventional systems. Quiet, reliable, long-life operation due to the absence of a compressor and the use of few moving parts are further critical distinguishing advantages. Modularity in cooling capacity has been demonstrated through scaling-up of component geometry and internal features and dimensions. The core technology was initially demonstrated with a proof-of-concept microscale absorption chiller measuring 200 × 200 × 34 mm and weighing 7 kg that delivered 300 W of cooling in laboratory tests. In the previous BEETIT project, the team made significant advances over the proof-of-concept. System and component designs with > 10× scale-up in capacity were developed, in a packaged unit capable of standalone operation with a semi-autonomous control system. A cooling capacity of 3.5 kW with a COP > 0.5 at an ambient temperature of 35°C was demonstrated for this natural gas-fired unit. Significant cost reductions in fabrication were achieved using low-cost brazing instead of diffusion bonding. In companion projects funded by the Southern Company and the Georgia Research Alliance, stamping and fluid forming techniques were investigated to fabricate microscale features instead of photochemical etching, thereby leading to significant cost reductions. In a follow-on effort funded by ARPA-E and NAVFAC, a 2.7 kW cooling unit was developed to provide cooling at a severe ambient condition of 51.7°C. The unit was driven directly by diesel engine exhaust heat. Innovative finned heat and mass exchangers for the ambient-coupled condenser and absorber were developed. In the present effort, a standalone, packaged and controllable 10.5 kW cooling capacity absorption chiller is developed. This demonstrates a 30× scale up from the proof-of-concept, thus validating the scalability of microchannel heat exchangers for absorption heat pumps. Autonomous operation algorithms demonstrated enhanced dynamic performance. The knowledge from previous projects was leveraged to develop novel component designs that further helped in miniaturizing the heat exchangers. All coupling fluids are hydronically coupled to aid flexible field deployment. The prototype unit provides design cooling capacity at high ambient temperature conditions of 44°C at COP > 0.6.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

Review of heat transfer enhancement techniques for single phase flows

The thermal energy exchange between a flowing fluid and its confining channel is a ubiquitous process in modern society. To enhance the fluid-to-wall or wall-to-fluid heat transfer, several techniques have been developed to maximize the contact area between the fluid and the inner wall and/or disrupt the flow to enhance circulation or induce turbulence. Deployment of channels having features capable of enhancing heat transfer enables the reduction of heat exchanger size while maintaining performance. Reduction in equipment size is critical due to the ability to minimize the required volume of costly working fluids and to mitigate potential safety concerns associated with total system fluid volume. Here, a comprehensive review of single-phase heat transfer enhancement techniques is presented. The article provides a thorough comparison by analyzing the heat transfer rate, pressure drop, and other operational aspects. Single-phase heat transfer enhancement methods are divided into active and passive techniques. Active methods such as electrohydrodynamic (EHD), magnetohydrodynamics (MHD), or mechanical motion require external power to create enhancement. Passive methods such as dimples, fins, or tape inserts do not require external input and rely only on surface modification. Although active methods are more expensive and difficult to implement compared to passive techniques, it enables active control of heat transfer augmentation. Finally, this review develops and summarizes key learning data for design optimization enabled by additive manufacturing and machine learning algorithms, helping to inform these next-generation heat exchanger design methodologies for a plethora of modern applications such as electrification of vehicles, computing, and classical industries.

42 ENGINEERING↗

Parametric Performance of a Spiral-Artery, Liquid-Trap-Diode Heat Pipe

A series of parametric investigations are described which determine the effect of various fluid charges on the performance of a 0.635-cm-diam spiral-artery, liquid-trap diode in both the forward and reverse modes. Specific parameters such as forward- and reverse-mode conductances, shutdown times and energies, and recovery to forward-model operation, are evaluated for ethane as a working fluid in the temperature range 170 K to 220 K. Results indicate that the heat pipe will not reliably start up in the forward mode. However, startup can be initiated when preceded by a diode reversal. Also included are data which show the susceptibility of the diode to fluid charge and tilt. The optimum fluid charge was found to be 2.67 g and transport capability at this charge was in excess of 1200 W-cm at 200 K. The diode in the reverse mode exhibited a rapid shutdown (within 9 min) with a shutdown energy of 1150 J (0.32 Wh).