Search NASA⌕ Search

SEARCH · Search NASA

Results for “bedding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Delineation of the Postprostatectomy Prostate Bed Using Computed Tomography: Interobserver Variability Following the EORTC Delineation Guidelines

Purpose: The present study aims to assess the interobserver agreement of prostate bed delineation after radical prostatectomy using CT alone as proposed by the European Organization for Research and Treatment of Cancer (EORTC) guidelines. Methods and Materials: Six observers delineated the postoperative prostate bed (PB) and the original seminal vesicle position or remnants (SV) of 10 patients according to the EORTC guidelines. Contours were then compared for agreement between observers (the apparent volume overlap and generalized kappa statistics). Standard deviations were also calculated to measure the variability of the position of the outer margins. Results: The mean volume of 100% agreement ({+-}1 standard deviation, SD) was only 5.0 ({+-}3.3) ml for the PB and 0.9 ({+-}1.5) ml for the SV, whereas the mean union of all contours ({+-}1 SD) was 41.1 ({+-}11.8) ml and 25.3 ({+-}13.4) ml, respectively. The mean overall agreement corrected for chance was moderate for both the PB (mean kappa, 0.49; range, 0.35-0.62) and SV (mean kappa, 0.42; range, 0.22-0.59). The overall SD of the outer margins of the PB ranged from 4.6 to 7.0 mm Conclusion: The delineation of the postprostatectomy bed using CT shows only a moderate observer agreement when following the EORTC guidelines.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relative Biologic Effectiveness (RBE) of 50 kV X-rays Measured in a Phantom for Intraoperative Tumor-Bed Irradiation

Purpose: Intraoperative radiation therapy (IORT) with low-energy x-rays is used to treat the tumor bed during breast-conserving surgery. The purpose was to determine the relative biologic effectiveness (RBE) of 50-kV x-rays for inactivation of cells irradiated in a tumor-bed phantom. Methods and Materials: The RBE was determined for clonogenic inactivation of human tumor and normal cells (MCF7, human umbilical vein endothelial cells, normal skin fibroblasts), and hamster V79 cells. The 50-kV x-rays from the Intrabeam machine (Carl Zeiss Surgical) with a spherical 4-cm applicator were used. Cells were irradiated in a water-equivalent phantom at defined distances (8.1-22.9 mm) from the applicator surface. The 50-kV x-rays from a surface therapy machine (Dermopan, Siemens) were included for comparison; 6-MV x-rays were used as reference radiation. Results: At 8.1-mm depth in the phantom (dose rate 15.1 Gy/h), mean RBE values of 50-kV x-rays from Intrabeam were 1.26 to 1.42 for the 4 cell types at doses yielding surviving fractions in the range of 0.01 to 0.5. Confidence intervals were in the range of 1.2 and 1.5. Similar RBE values were found for 50-kV x-rays from Dermopan for V79 (1.30, CI 1.25-1.36, P=.74) and GS4 (1.42, CI 1.30-1.54, P=.67). No significant dependence of RBE on dose was found for Intrabeam, but RBE decreased at a larger distance (12.7 mm; 9.8 Gy/h). Conclusions: An increased clinically relevant RBE was found for cell irradiation with Intrabeam at depths in the tumor bed targeted by IORT. The reduced RBE values at larger distances may be related to increased repair of sublethal damage during protracted irradiation or to hardening of the photon beam energy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computational and experimental prediction of dust production in pebble bed reactors, Part II

This paper is the continuation of Part I, which describes the high temperature and high pressure helium environment wear tests of graphite–graphite in frictional contact. In the present work, it has been attempted to simulate a Pebble Bed Reactor core environment as compared to Part I. The experimental apparatus, which is a custom-designed tribometer, is capable of performing wear tests at PBR relevant higher temperatures and pressures under a helium environment. This environment facilitates prediction of wear mass loss of graphite as dust particulates from the pebble bed. The experimental results of high temperature helium environment are used to anticipate the amount of wear mass produced in a pebble bed nuclear reactor.

99 GENERAL AND MISCELLANEOUS↗

Improving hydrolysis of food waste in a leach bed reactor

Highlights: • This paper assesses leaching of food waste in a two phase digestion system. • Leaching is assessed with and without an upflow anaerobic sludge blanket (UASB). • Without the UASB, low pH reduces hydrolysis, while increased flows increase leaching. • Inclusion of the UASB increases pH to optimal levels and greatly improves leaching. • The optimal conditions are suggested as low flow with connection to the UASB. - Abstract: This paper examines the rate of degradation of food waste in a leach bed reactor (LBR) under four different operating conditions. The effects of leachate recirculation at a low and high flow rate are examined with and without connection to an upflow anaerobic sludge blanket (UASB). Two dilution rates of the effective volume of the leach bed reactors were investigated: 1 and 6 dilutions per LBR per day. The increase in dilution rate from 1 to 6 improved the destruction of volatile solids without connection to the UASB. However connection to the UASB greatly improved the destruction of volatile solids (by almost 60%) at the low recirculation rate of 1 dilution per day. The increase in volatile solids destruction with connection to the UASB was attributed to an increase in leachate pH and buffering capacity provided by recirculated effluent from the UASB to the leach beds. The destruction of volatile solids for both the low and high dilution rates was similar with connection to the UASB, giving 82% and 88% volatile solids destruction respectively. This suggests that the most efficient leaching condition is 1 dilution per day with connection to the UASB.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Isotherm, Kinetic, Process Modeling, and Techno-Economic Analysis of a Diamine-Appended Metal-Organic Framework for CO 2 Capture Using Fixed Bed Contactors

In this report, diamine-appended metal-organic frameworks exhibiting step-shaped CO 2 adsorption are exceptional candidates for energy-efficient carbon capture. However, there are few studies examining their performance in real-world capture scenarios, in part due to the challenge inherent in modeling their CO 2 uptake behavior. Here, we develop a dual-site Sips model to fit experimental CO 2 adsorption data for dmpn-Mg 2 (dobpdc) (dmpn = 2,2-dimethyl-1,3-diaminopropane; dobpdc 4- = 4,4'-dioxidobiphenyl-3,3'-dicarboxylate) and develop a linear driving force model for the adsorption kinetics based on available experimental data. These models are used to develop a dynamic, fixed bed, nonisothermal contactor model using shaped particles of the material, which is validated with experimental breakthrough data. We also examine the effects of the high heat of adsorption of the material on CO 2 uptake performance and find that heat removal is essential to maximize capture performance. We finally investigate "basic"(no bed cooling during adsorption) and "modified"(bed cooling during adsorption) temperature swing adsorption (TSA) processes using dmpn-Mg 2 (dobpdc), and their process economics are compared to a state-of-the-art monoethanolamine (MEA) capture system with and without heat recovery. In the absence of heat recovery, the adsorbent systems are more costly than established technology. However, with 85% heat recovery, both adsorbent-based TSA processes are projected to cost less than the MEA system. This work highlights that thermal management is vital for implementation of dmpn-Mg 2 (dobpdc) as a viable CO 2 capture technology. Investigation of other contactor technologies that can provide unique ways to manage system heat represent promising future areas of study.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetics of Direct Olefin Synthesis from Syngas over Mixed Beds of Zn–Zr Oxides and SAPO-34

A packed bed containing a physical mixture of both Zn–Zr mixed oxide catalyst and SAPO-34 converts syngas directly into a mixture of C 2 –C 5 olefins and paraffins. Specifically, the mixed oxide catalyst is responsible for intermediate oxygenate synthesis from syngas while the molecular sieve catalyzes olefin synthesis from the oxygenate intermediates. Kinetic measurements with cofed propylene over each catalyst independently confirm olefin hydrogenation activity over both components of the composite bed. The addition of either water or CO to the feed drops the activity of propylene hydrogenation over the Zn–Zr oxide. In sum, under reaction conditions of syngas feed and produced water, olefin hydrogenation predominantly occurs over the SAPO-34 catalyst, rather than over the catalyst responsible for hydrogenating CO into oxygenate intermediates. Here, a developed kinetic model consistent with this conclusion describes measurements at differing feed compositions, temperatures, space velocities, and bed catalyst mixing ratios. Technoeconomic analysis of the process indicates that the olefin-to-paraffin ratio is a key performance metric for commercial scale syngas conversion and highlights the importance of considering olefin hydrogenation rates over the molecular sieve component.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase shift method to estimate solids circulation rate in circulating fluidized beds

While solids circulation rate is a critical design and control parameter in circulating fluidized bed (CFB) reactor systems, there are no available techniques to measure it directly at conditions of industrial interest. Cold flow tests have been conducted at NETL in an industrial scale CFB unit where the solids flow has been the topic of research in order to develop an independent method which could be applied to CFBs operating under the erosive and corrosive high temperatures and pressures of a coal fired boiler or gasifier. The dynamic responses of the CFB loop to modest modulated aeration flows in the return leg or standpipe were imposed to establish a periodic response in the unit without causing upset in the process performance. The resulting periodic behavior could then be analyzed with a dynamic model and the average solids circulation rate could be established. This method was applied to the CFB unit operated under a wide range of operating conditions including fast fluidization, core annular flow, dilute and dense transport, and dense suspension upflow. In addition, the system was operated in both low and high total solids inventories to explore the influence of inventory limiting cases on the estimated results. The technique was able to estimate the solids circulation rate for all transport circulating fluidized beds when operating above upper transport velocity, U{sub tr2}. For CFB operating in the fast fluidized bed regime (i.e., U{sub g}< U{sub tr2}), the phase shift technique was not successful. The riser pressure drop becomes independent of the solids circulation rate and the mass flow rate out of the riser does not show modulated behavior even when the riser pressure drop does.

42 ENGINEERING↗

Dynamics of pore formation during laser powder bed fusion additive manufacturing

Abstract Laser powder bed fusion additive manufacturing is an emerging 3D printing technique for the fabrication of advanced metal components. Widespread adoption of it and similar additive technologies is hampered by poor understanding of laser-metal interactions under such extreme thermal regimes. Here, we elucidate the mechanism of pore formation and liquid-solid interface dynamics during typical laser powder bed fusion conditions using in situ X-ray imaging and multi-physics simulations. Pores are revealed to form during changes in laser scan velocity due to the rapid formation then collapse of deep keyhole depressions in the surface which traps inert shielding gas in the solidifying metal. We develop a universal mitigation strategy which eliminates this pore formation process and improves the geometric quality of melt tracks. Our results provide insight into the physics of laser-metal interaction and demonstrate the potential for science-based approaches to improve confidence in components produced by laser powder bed fusion.

36 MATERIALS SCIENCE↗

Zinc-finger BED domains drive the formation of the active Hermes transpososome by asymmetric DNA binding

The Hermes DNA transposon is a member of the eukaryotic hAT superfamily, and its transposase forms a ring-shaped tetramer of dimers. Our investigation, combining biochemical, crystallography and cryo-electron microscopy, and in-cell assays, shows that the full-length Hermes octamer extensively interacts with its transposon left-end through multiple BED domains of three Hermes protomers contributed by three dimers explaining the role of the unusual higher-order assembly. By contrast, the right-end is bound to no BED domains at all. Thus, this work supports a model in which Hermes multimerizes to gather enough BED domains to find its left-end among the abundant genomic DNA, facilitating the subsequent interaction with the right-end.

59 BASIC BIOLOGICAL SCIENCES↗

Revealing particle-scale powder spreading dynamics in powder-bed-based additive manufacturing process by high-speed x-ray imaging

Powder spreading is a key step in the powder-bed-based additive manufacturing process, which determines the quality of the powder bed and, consequently, affects the quality of the manufactured part. However, powder spreading behavior under additive manufacturing condition is still not clear, largely because of the lack of particle-scale experimental study. Here, we studied particle-scale powder dynamics during the powder spreading process by using in-situ high-speed high-energy x-ray imaging. Evolution of the repose angle, slope surface speed, slope surface roughness, and the dynamics of powder clusters at the powder front were revealed and quantified. Interactions of the individual metal powders, with boundaries (substrate and container wall), were characterized, and coefficients of friction between the powders and boundaries were calculated. The effects of particle size on powder flow dynamics were revealed. Here, the particle scale powder spreading dynamics, reported here, are important for a thorough understanding of powder spreading behavior in the powder-bed-based additive manufacturing process, and are critical to the development and validation of models that can more accurately predict powder spreading behavior.

42 ENGINEERING↗

Development of a microwave-assisted downdraft moving-bed gasifier for continuous processing of lignite and biomass chars

This research illustrates a microwave-assisted downdraft moving-bed gasifier for the first time. Such design enables continuous solid gasification process. An adjustable auger was applied to control the solid removal rate and the gas-solid interaction time. Both lignite and biomass chars were investigated to determine the capability of the current system for low-tar feedstocks with different densities. Here, the presented reactor design was able to operate continuously for 3 hours and 20 minutes under 700 ℃ and atmospheric pressure, with air as the gasifying agent. For yellow pine char, the processing rate could reach 34.1 grams per hour with decent syngas production. The downdraft moving-bed design shows better cold gas and syngas production efficiencies compared to the common fixed-bed design, due to controllable residence time and more homogeneous microwave heating. The limitations of the current design and the direction of novel microwave-assisted chemical reactor design were discussed. This novel reactor design provides a way to improve the efficiency of microwave-assisted gasification process and shows its potential to be incorporated into other established chemical reaction processes as a modular add-on.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Mach number and volume fraction in air-shock interacting with a bed of randomly distributed spherical particles

Shock-particle interaction is a fundamental problem in many engineering applications, with the dynamics being heavily influenced by the incident-shock Mach number and the particle volume fraction. In this paper we present fully resolved inviscid simulations of an incident-shock wave traveling through a bed of randomly distributed spherical particles. We vary the strength of the incident shock along with the particle volume fraction in order to study the complex wave interaction during shock-particle interaction. In this study we are interested in the early-time behavior during which the particles do not move and hence in our simulations all the particles are fixed in space. We compute the streamwise average of flow field quantities to generate the x - t contour plots to study the unsteady oscillations inside the particle bed. We observe that the transmitted shock slows down under certain conditions and it is partly due to tortuosity and partly due to weakening caused by energy dissipation. We also present the force histories of the streamwise drag and lift forces for all the particles. The random distribution of particles leads to high variability in the drag force experienced by the particles. We compute the mean peak drag force as a function of the streamwise location to study the mean behavior of the transmitted shock. Based on our findings, we propose simple modifications to improve the current point-particle models used in Euler-Lagrange simulations of shock interacting with a bed of particles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Implementation of Full-Scale Industrial Control System Test Bed for Assessing Cyber-Security Defenses

In response to the increasing awareness of the Ethernet-based threat surface of industrial control systems (ICS), both the research and commercial communities are responding with ICS-specific security solutions. Unfortunately, many of the properties of ICS environments that contribute to the extent of this threat surface (e.g. age of devices, inability or unwillingness to patch, criticality of the system) similarly prevent the proper testing and evaluation of these security solutions. Production environments are often too fragile to introduce unvetted technology and most organizations lack test environments that are sufficiently consistent with production to yield actionable results. Cost and space requirements prevent the creation of mirrored physical environments leading many to look towards simulation or virtualization. Examples in literature provide various approaches to building ICS test beds, though most of these suffer from a lack of realism due to contrived scenarios, synthetic data and other compromises. In this paper, we provide a design methodology for building highly realistic ICS test beds for validating cybersecurity defenses. We then apply that methodology to the design and building of a specific test bed and describe the results and experimental use cases.

Gillen, Rob↗

PlanHab * : hypoxia does not worsen the impairment of skeletal muscle oxidative function induced by bed rest alone

Key points Superposition of hypoxia on 21 day bed rest did not worsen the impairment of skeletal muscle oxidative function induced by bed rest alone. A significant impairment of maximal oxidative performance was identified downstream of cardiovascular O 2 delivery, involving both the intramuscular matching between O 2 supply and utilization and mitochondrial respiration. These chronic adaptations appear to be relevant in terms of exposure to spaceflights and reduced gravity habitats (Moon or Mars), as characterized by low gravity and hypoxia, in patients with chronic diseases characterized by hypomobility/immobility and hypoxia, as well as in ageing. Abstract Skeletal muscle oxidative function was evaluated in 11 healthy males (mean ± SD age 27 ± 5 years) prior to (baseline data collection, BDC) and following a 21 day horizontal bed rest (BR), carried out in normoxia ( = 133 mmHg; N‐BR) and hypoxia ( = 90 mmHg; H‐BR). H‐BR was aimed at simulating reduced gravity habitats. The effects of a 21 day hypoxic ambulatory confinement ( = 90 mmHg; H‐AMB) were also assessed. Pulmonary O 2 uptake ( ), vastus lateralis fractional O 2 extraction (changes in deoxygenated haemoglobin + myoglobin concentration, Δ[deoxy(Hb + Mb)]; near‐infrared spectroscopy) and femoral artery blood flow (ultrasound Doppler) were evaluated during incremental one‐leg knee‐extension exercise (reduced constraints to cardiovascular O 2 delivery) carried out to voluntary exhaustion in a normoxic environment. Mitochondrial respiration was evaluated ex vivo by high‐resolution respirometry in permeabilized vastus lateralis fibres. decreased ( P < 0.05) after N‐BR (0.98 ± 0.13 L min −1 ) and H‐BR (0.96 ± 0.17 L min −1 ) vs . BDC (1.05 ± 0.14 L min −1 ). In the presence of a decreased (by ∼6–8%) thigh muscle volume, normalized per unit of muscle mass was not affected by both interventions. Δ[deoxy(Hb + Mb)] peak decreased ( P < 0.05) after N‐BR (65 ± 13% of limb ischaemia) and H‐BR (62 ± 12%) vs . BDC (73 ± 13%). H‐AMB did not alter or Δ[deoxy(Hb + Mb)] peak . An overshoot of Δ[deoxy(Hb + Mb)] was evident during the first minute of unloaded exercise after N‐BR and H‐BR. Arterial blood flow to the lower limb during both unloaded and peak knee extension was not affected by any intervention. Maximal ADP‐stimulated mitochondrial respiration decreased ( P < 0.05) after all interventions vs . control. In 21 day N‐BR, a significant impairment of oxidative metabolism occurred downstream of cardiovascular O 2 delivery, affecting both mitochondrial respiration and presumably the intramuscular matching between O 2 supply and utilization. Superposition of H on BR did not worsen the impairment induced by BR alone.

Salvadego, Desy↗

Understanding Laser Powder Bed Fusion Surface Roughness

Abstract Surface roughness is a well-known consequence of additive manufacturing methods, particularly powder bed fusion processes. To properly design parts for additive manufacturing, a comprehensive understanding of the inherent roughness is necessary. While many researchers have measured different surface roughness resultant from a variety of parameters in the laser powder bed fusion process, few have succeeded in determining causal relationships due to the large number of variables at play. To assist the community in understanding the roughness in laser powder bed fusion processes, this study explored several studies from the literature to identify common trends and discrepancies amongst roughness data. Then, an experimental study was carried out to explore the influence of certain process parameters on surface roughness. Through these comparisons, certain local and global roughness trends have been identified and discussed, as well as a new framework for considering the effect of process parameters on surface roughness.

Engineering↗

Large Eddy Simulation of Convective Heat Transfer in a Random Pebble Bed Using the Spectral Element Method

The development of fluoride-cooled high-temperature reactors has drastically increased the demand for an in-depth understanding of the heat transfer (HT) in packed beds cooled by liquid salts. The complex flow fields and space-dependent porosity found in a pebble bed require a detailed understanding to ensure the proper cooling of the reactor core during normal and accident conditions. As detailed experimental data are complicated to obtain for these configurations, high-fidelity simulation such as large eddy simulation and direct numerical simulation (DNS) can be employed to create a high-resolution heat transfer numerical database that can assist in addressing industrial-driven issues associated with the heat transfer behavior of fluoride-cooled high-temperature reactors. In this paper, we performed a series of large eddy simulation using computational fluid dynamics (CFD) code NekRS to investigate the heat transfer for a bed of 1741 pebbles. Further, the characteristics of the flow, such as average, rms, and time series of velocity and temperature, have been analyzed. Porous media averages have also been performed. The simulation results show a good agreement between non-conjugate heat transfer and conjugate heat transfer. The generated data will be used to benchmark heat transfer modeling methods and local maxima/minima of heat transfer parameters. It will also be used for supporting convective heat transfer quantification for Kairos Power and benchmarking lower fidelity models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-510: Mathematical Analysis of Approximate Biological Effective Dose (BED) Calculation for Multi-Phase Radiotherapy Treatment Plans

Purpose: There is growing interest about biological effective dose (BED) and its application in treatment plan evaluation due to its stronger correlation with treatment outcome. An approximate biological effective dose (BEDA) equation was introduced to simplify BED calculations by treatment planning systems in multi-phase treatments. The purpose of this work is to reveal its mathematical properties relative to the true, multi-phase BED (BEDT) equation. Methods: The BEDT equation was derived and used to reveal the mathematical properties of BEDA. MATLAB (MathWorks, Natick, MA) was used to simulate and analyze common and extreme clinical multi-phase cases. In those cases, percent error (Perror) and Bland-Altman analysis were used to study the significance of the inaccuracies of BEDA for different combinations of total doses, numbers of fractions, doses per fractions and α over β values. All the calculations were performed on a voxel-basis in order to study how dose distributions would affect the accuracy of BEDA. Results: When the voxel dose-per-fractions (DPF) delivered by both phases are equal, BEDA and BEDT are equal. In heterogeneous dose distributions, which significantly vary between the phases, there are fewer occurrences of equal DPFs and hence the imprecision of BEDA is greater. It was shown that as the α over β ratio increased the accuracy of BEDA would improve. Examining twenty-four cases, it was shown that the range of DPF ratios for a 3 Perror varied from 0.32 to 7.50Gy, whereas for Perror of 1 the range varied from 0.50 to 2.96Gy. Conclusion: The DPF between the different phases should be equal in order to render BEDA accurate. OARs typically receive heterogeneous dose distributions hence the probability of equal DPFs is low. Consequently, the BEDA equation should only be used for targets or OARs that receive uniform or very similar dose distributions by the different treatment phases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The emergence of nonuniform spatiotemporal fractionation schemes within the standard BED model

Purpose: Nonuniform spatiotemporal radiotherapy fractionation schemes, i.e., delivering distinct dose distributions in different fractions can potentially improve the therapeutic ratio. This is possible if the dose distributions are designed such that similar doses are delivered to normal tissues (exploit the fractionation effect) while hypofractionating subregions of the tumor. In this paper, the authors develop methodology for treatment planning with nonuniform fractions and demonstrate this concept in the context of intensity-modulated proton therapy (IMPT). Methods: Treatment planning is performed by simultaneously optimizing (possibly distinct) IMPT dose distributions for multiple fractions. This is achieved using objective and constraint functions evaluated for the cumulative biologically equivalent dose (BED) delivered at the end of treatment. BED based treatment planning formulations lead to nonconvex optimization problems, such that local gradient based algorithms require adequate starting positions to find good local optima. To that end, the authors develop a combinatorial algorithm to initialize the pencil beam intensities. Results: The concept of nonuniform spatiotemporal fractionation schemes is demonstrated for a spinal metastasis patient treated in two fractions using stereotactic body radiation therapy. The patient is treated with posterior oblique beams with the kidneys being located in the entrance region of the beam. It is shown that a nonuniform fractionation scheme that hypofractionates the central part of the tumor allows for a skin and kidney BED reduction of approximately 10%–20%. Conclusions: Nonuniform spatiotemporal fractionation schemes represent a novel approach to exploit fractionation effects that deserves further exploration for selected disease sites.

60 APPLIED LIFE SCIENCES↗