Search NASA⌕ Search

SEARCH · Search NASA

Results for “computational fluid dynamics simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Validation of the Computational Fluid Dynamics Method using the Aboveground Configuration of the Dry Cask Simulator

Dry cask applicants submit their spent nuclear fuel dry storage and transportation cask designs to the U.S. Nuclear Regulatory Commission (NRC) for certification under Title 10 of the Code of Federal Regulations (10 CFR) Part 72, 'Licensing Requirements for the Independent Storage of Spent Nuclear Fuel, High-Level Radioactive Waste, and Reactor-Related Greater Than Class C Waste'. The NRC staff performs its technical review of these designs in accordance with 10 CFR Part 72 and NUREG-1536, 'Standard Review Plan for Spent Fuel Dry Storage Systems at a General License Facility,' Revision 1, issued July 2010. To ensure that the cask and fuel material temperatures of the dry cask storage system remain within the allowable limits or criteria for normal, off-normal, and accident conditions, the NRC staff performs a thermal review as part of the technical review. Recent applications increasingly have used thermalhydraulic analyses using computational fluid dynamics (CFD) codes (e.g., ANSYS FLUENT) to demonstrate the adequacy of the thermal design. The NRC performs validation studies of the FLUENT CFD code to assist it in making regulatory decisions to ensure adequate protection for storage and transportation casks. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. In efforts to further validate these designs, the NRC in conjunction with the Department of Energy and Sandia National Laboratories (SNL) are conducting an experiment to capture the effects of elevated helium pressures and accurately portray the external convection of aboveground and belowground canister dry cask systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of RANS vs. LES simulation of fluid flow through 3 × 3 rod bundle with a simple spacer grid as a precursor to coupled fluid–structure interaction simulations

The research literature on Computational Fluid Dynamics (CFD) of coolant flow through rod bundles with spacer-grids and mixing vanes is replete, ranging from high fidelity Large Eddy Simulation (LES)/Direct Numerical Simulation (DNS) simulations to Reynolds-Averaged Navier–Stokes (RANS) modeled studies. The mixing of flow between subchannels and the pressure drop through the bundle are fundamental quantities useful for comparing and evaluating CFD methods. Less commonly observed and compared are the forces exerted onto the structure by the fluid. The present study seeks to evaluate the use of RANS simulations for predicting the structural response to fluid flow. Wall resolved RANS simulations are benchmarked against LES simulations of fluid flow at a Reynolds number of 15,000 through a 3 × 3 fuel rod bundle with a simple spacer grid. Velocity line-plots are compared showing good agreement between RANS and LES results, ascertaining that the former is capable of capturing the essential time-averaged velocity profile. Additionally, the distribution of forces on the spacer grid and fuel rods are collected as a function of time and space. The RANS methods are evaluated using the frequency and magnitude of the fluctuating forces on various portions of the structure as compared to LES. In conclusion, the power spectral density evaluation of the models reveal underprediction of force amplitude on the rod walls by RANS and also discrepancy in the prediction of high frequency spectra, especially in the immediate vicinity of spacer-grid structure, which may be attributed to the lack of random turbulence fluctuation or insufficient modeling of small-scale eddies in RANS simulation.

FIV↗

Flow Field and Pressure Measurements in a 61-Pin Wire-Wrapped Bundle

Texas A and M University is conducting isothermal flow tests in a wire-wrapped, 61-pin hexagonal fuel bundle to support the research on advanced nuclear fuel development sponsored by the Department of Energy (DOE). The purpose of these tests is to produce high spatial- and temporal-resolution measurements of the flow and pressure measurements at different locations of the test bundle. The data resulting from these tests will be used to benchmark numerical simulations of the experiments using both industry-standard Reynolds-averaged Navier-Stokes (RANS) based Computation Fluid Dynamics (CFD) methods and a highly resolved Large Eddy Simulation (LES) computer code. This article described the main features of the experimental facility, its capabilities in producing experimental data of pressure drop and velocity fields at different axial locations and within different exterior and interior sub-channels, using advanced flow visualization techniques. Examples of experimental data outputs and typical locations of the measurements that will included in the research scope are also shown in this article. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification and Validation of Open-Source Computational Fluid Dynamics Capabilities in MOOSE

The Multiphysics Object Oriented Simulation Environment (MOOSE) advances predictive modeling in nuclear research by simplifying the application design process and making modeling more efficient and accessible to researchers and the broader community. Because of MOOSE’s critical role in the scientific computation field, verification and validation are important to evaluate the reliability and credibility of MOOSE’s code, simulations, and models. To assess MOOSE’s Navier Stokes module and turbulence models, the following verification and validation University of Manchester ERCOFTAC cases were simulated in MOOSE, and the results were compared: Case 032 Turbulent Flow in a 2D Channel Case 079 Natural Convection in an Enclosed Cavity

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

CAPE-OPEN compliant stochastic modeling and reduced-order model computation capability for APECS system

APECS (Advanced Process Engineering Co-Simulator) is an integrated software suite that combines the power of process simulation with high-fidelity, computational fluid dynamics (CFD) for improved design, analysis, and optimization of process engineering systems. The APECS system uses commercial process simulation (e.g., Aspen Plus) and CFD (e.g., FLUENT) software integrated with the process-industry standard CAPE-OPEN (CO) interfaces. This breakthrough capability allows engineers to better understand and optimize the fluid mechanics that drive overall power plant performance and efficiency. The focus of this paper is the CAPE-OPEN complaint stochastic modeling and reduced order model computational capability around the APECS system. The usefulness of capabilities is illustrated with coal fired, gasification based, FutureGen power plant simulation. These capabilities are used to generate efficient reduced order models and optimizing model complexities.

01 COAL, LIGNITE, AND PEAT↗

Fluid-Structure Interaction Modeling of High-Aspect Ratio Nuclear Fuel Plates Using COMSOL

The High Flux Isotope Reactor at the Oak Ridge National Lab is in the research stage of converting its fuel from high-enriched uranium to low-enriched uranium. Due to different physical properties of the new fuel and changes to the internal fuel plate design, the current safety basis must be re-evaluated through rigorous computational analyses. One of the areas being explored is the fluid-structure interaction phenomenon due to the interaction of thin fuel plates (50 mils thickness) and the cooling fluid (water). Detailed computational fluid dynamics and fluid-structure interaction simulations have only recently become feasible due to improved numerical algorithms and advancements in computing technology. For many reasons including the already built-in fluid-structure interaction module, COMSOL has been chosen for this complex problem. COMSOL's ability to solve multiphysics problems using a fully-coupled and implicit solution algorithm is crucial in obtaining a stable and accurate solution. Our initial findings show that COMSOL can accurately model such problems due to its ability to closely couple the fluid dynamics and the structural dynamics problems.

Fluid-Structure Interaction↗

Enhancing $\phi$-sensitivity of ignition delay times through dilution of fuel-air mixture

The high $\phi$-sensitivity (η) of ignition delay time (τ IDT ) is one of the desirable fuel properties for the high-load extension of advanced compression ignition engine. Recent studies revealed the effectiveness of a high dilution rate (x D ) for enhancing η at the engine-relevant conditions. This study aims to quantify the effect of dilution on the η of isooctane using a combined experiment-simulation approach. The ignition delay of the isooctane/air mixture was measured with an Advanced Fuel Ignition Delay Analyzer (AFIDA) over the temperature range of 623 - 923 K at 10 bar pressure with global $\phi$ = 0.3 - 0.6, with and without 28.6% of additional N 2 dilution. For precise evaluation of experimental η, the facility effect of the AFIDA experiment was characterized with three-dimensional computational fluid dynamics (3-D CFD) simulation. The temperature in the combustion chamber from 3-D CFD indicated a substantial temporal dependency, varying up to ~52 K by charge-cooling of fuel injection and heat transfer from the wall. We introduced the dimensionless number θ(t) for characterizing the temporal profile of chamber temperature. Consideration of the facility effect using θ(t) resulted in better agreement between the experimental ..eta.. and zero-dimensional (0-D) kinetics simulation. The refined η were then further utilized to quantify the effectiveness of dilution to η The extent of η enhancement with dilution strategy was maximized at the low-temperature chemistry regime, increasing η by 77% with a 28.6% dilution rate. Further analysis on the dilution effect was carried out using 0-D kinetics simulation, revealing the critical dimensionless numbers relevant to the effectiveness of dilution to η enhancement. Here, this study is the first experiment-simulation combined research to quantify the effect of dilution on η, facilitating the kinetics model refinement for better reproduction of $\phi$-sensitivity.

33 ADVANCED PROPULSION SYSTEMS↗

CFD validation in OECD/NEA t-junction benchmark.

When streams of rapidly moving flow merge in a T-junction, the potential arises for large oscillations at the scale of the diameter, D, with a period scaling as O(D/U), where U is the characteristic flow velocity. If the streams are of different temperatures, the oscillations result in experimental fluctuations (thermal striping) at the pipe wall in the outlet branch that can accelerate thermal-mechanical fatigue and ultimately cause pipe failure. The importance of this phenomenon has prompted the nuclear energy modeling and simulation community to establish a benchmark to test the ability of computational fluid dynamics (CFD) codes to predict thermal striping. The benchmark is based on thermal and velocity data measured in an experiment designed specifically for this purpose. Thermal striping is intrinsically unsteady and hence not accessible to steady state simulation approaches such as steady state Reynolds-averaged Navier-Stokes (RANS) models.1 Consequently, one must consider either unsteady RANS or large eddy simulation (LES). This report compares the results for three LES codes: Nek5000, developed at Argonne National Laboratory (USA), and Cabaret and Conv3D, developed at the Moscow Institute of Nuclear Energy Safety at (IBRAE) in Russia. Nek5000 is based on the spectral element method (SEM), which is a high-order weighted residual technique that combines the geometric flexibility of the finite element method (FEM) with the tensor-product efficiencies of spectral methods. Cabaret is a 'compact accurately boundary-adjusting high-resolution technique' for fluid dynamics simulation. The method is second-order accurate on nonuniform grids in space and time, and has a small dispersion error and computational stencil defined within one space-time cell. The scheme is equipped with a conservative nonlinear correction procedure based on the maximum principle. CONV3D is based on the immersed boundary method and is validated on a wide set of the experimental and benchmark data. The numerical scheme has a very small scheme diffusion and is the second and the first order accurate in space and time, correspondingly. We compare and contrast simulation results for three computational fluid dynamics codes CABARET, Conv3D, and Nek5000 for the T-junction thermal striping problem that was the focus of a recent OECD/NEA blind benchmark. The corresponding codes utilize finite-difference implicit large eddy simulation (ILES), finite-volume LES on fully staggered grids, and an LES spectral element method (SEM), respectively. The simulations results are in a good agreement with experimenatl data. We present results from a study of sensitivity to computational mesh and time integration interval, and discuss the next steps in the simulation of this problem.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Measurement of Turbulent Flow Phenomena for the Lower Plenum of a Prismatic Gas-Cooled Reactor

Mean velocity field and turbulence data are presented that measure turbulent flow phenomena in an approximately 1:7 scale model of a region of the lower plenum of a typical prismatic gas-cooled reactor (GCR) similar to a General Atomics design (Gas-Turbine-Modular Helium Reactor). The datawere obtained in the Matched-Index-of-Refraction (MIR) facility at Idaho National Laboratory (INL) and are offered as a benchmark for assessing computational fluid dynamics (CFD) software. This experiment has been selected as the first Standard Problem endorsed by the Generation IV International Forum. The primary objective of this paper is to document the experiment and present a sample of the data set that has been established for this standard problem. Present results concentrate on the region of the lower plenum near its far reflector wall (away from the outlet duct). The flowin the lower plenum consists of multiple jets injected into a confined crossflow—with obstructions. The model consists of a row of full circular posts along its centerline with half-posts on the two parallel walls to approximate flow scaled to that expected from the staggered parallel rows of posts in the reactor design. Posts, side walls and end walls are fabricated from clear, fused quartz to match the refractive index of the mineral oil working fluid so that optical techniques may be employed for the measurements. The benefit of the MIR technique is that it permits optical measurements to determine flow characteristics in complex passages and around objects to be obtained without locating intrusive transducers that will disturb the flow field and without distortion of the optical paths. An advantage of the INL system is its large size, leading to improved spatial and temporal resolution compared to similar facilities at smaller scales. A three-dimensional (3D) particle image velocimetry (PIV) system was used to collect the data. Inlet-jet Reynolds numbers (based on the hydraulic diameter of the jet and the timemean average flow rate) are approximately 4300 and 12,400. Uncertainty analysis and a discussion of the standard problem are included. The measurements reveal complicated flow patterns that include several large recirculation zones, reverse flow near the simulated reflector wall, recirculation zones in the upper portion of the plenum and complex flow patterns around the support posts. Data include three-dimensional PIV images of flow planes, data displays along the coordinate planes (slices) and presentations that describe the component flows at specific regions in the model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Optimization of A-Type Heat Exchangers based on High Performance, Non-Round Tubes

Air-to-refrigerant heat exchangers (HXs) have been the topic of considerable research as they are the fundamental heat transfer components of HVAC&R systems. For residential and commercial applications, indoor heat exchangers are often in A-type configurations to reduce air-conditioner system footprint while still delivering the required cooling or heating. Classical HX design practices typically assume a uniform frontal air velocity profile to facilitate the use of conventional tube-fin airside heat transfer and pressure drop correlations for performance prediction. However, it is well-reported throughout the literature that A-type HXs experience significant airflow maldistribution which can severely degrade HX performance. Additionally, recent advancements in simulation software such as Computational Fluid Dynamics (CFD), Finite Element Analysis (FEA) and optimization algorithms have led researchers to consider primary heat transfer surface optimization to achieve highly compact HXs which do not require fins. In this paper, an A-type HX which utilizes shape-optimized non-round tubes is optimized for minimum duct size and airside pressure drop. This is achieved through coupling of an experimentally validated finite volume HX model with automated 2D CFD simulations of airflow through the HX for airside thermal-hydraulic performance evaluation. Preliminary results show that the optimal designs deliver similar capacity while achieving 20% reductions in airside pressure drop and duct cross-section area. Additionally, the optimal design apex angles in this study were similar to those from previous A-Type HX optimization studies for conventional tube-fin HX geometries, suggesting that the apex angle for optimal A-Type configuration performance may be independent of tube geometry.

42 ENGINEERING↗

Optimization of a Cyclone Using Multiphase Flow Computational Fluid Dynamics

The U.S. Department of Energy National Energy Technology Laboratory's (NETL) 50 kW th chemical looping reactor (CLR) has an underperforming cyclone, which was designed using empirical correlations. To improve the performance of this cyclone using computational fluid dynamics (CFD)-based modeling simulations, four critical design parameters including the vortex tube radius and length, barrel radius, and the inlet width and height were optimized. Here, NETL's open source multiphase flow with interphase exchange (MFiX) CFD code has been used to model a series of cyclones by systematically varying the geometric design parameters. To perform the optimization process, the surrogate modeling and sensitivity analysis followed by the optimization capability in nodeworks was used. The basic methodology for the process is to employ a statistical design of experiments (DOE) method to generate sampling simulations that fill the design space. Corresponding CFD models are then created, executed, and postprocessed. A response surface is created to characterize the relationship between input parameters and the quantities of interest (QoI). Finally, the CFD-surrogate is used by an optimization method to find the optimal design condition based on the objective and constraints prescribed. The resulting optimal cyclone has a larger diameter and longer vortex tube, a larger diameter barrel, and a taller and narrower solids inlet. The improved design has a predicted pressure drop 11 times lower than the original design while reducing the mass loss by a factor of 2.3.

42 ENGINEERING↗

Simulation of an Industrial Tangentially Fired Boiler Firing Metallurgical Gases

In industrial environments, boiler units are widely used to supply heat and electrical power. At an integrated steel mill, industrial boilers combust a variable mixture of metallurgical gases combined with additional fuels to generate high-pressure superheated steam. Most tangentially fired boilers have experienced water wall tube failures in the combustion zone, which are thought to be caused by some deficiency in the combustion process. The challenge faced in this present process is that there are very limited means to observe the boiler operation. In our study, a three-dimensional computational fluid dynamics (CFD) modeling and simulation of an industrial tangentially fired boiler firing metallurgical gases was conducted. Eddy dissipation combustion model was applied on this multiple fuel combustion process. Simulation results obtained from the developed CFD model were validated by industrial experiments. Furthermore, a quick comparison of the flame shape from the simulation to the actual flame in the boiler showed a good agreement. We also analyzed the flow field and temperature distribution inside the tangentially fired boiler under the operation conditions, and a wall water tube overheating problem was observed and directly related to the flow

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Investigation into the Effects of Swirl on the Performance and Emissions of an Opposed-Piston Two-Stroke Engine using Large Eddy Simulations

Opposed-piston two-stroke (OP-2S) engines have the potential to achieve higher thermal efficiency than a conventional four-stroke diesel engine. However, the uniflow scavenging process is difficult to control over a wider range of speed and loads due to its sensitivity to pressure dynamics, port timings, and port design. Specifically, the angle of the intake ports can be used to generate swirl which has implications for open and closed cycle effects. This study proposes an analysis of the effects of port angle on the in-cylinder flow distribution and combustion performance of an OP-2S using computational fluid dynamics engine. Large Eddy Simulation (LES) was used to model turbulence given its ability to predict in-cylinder mixing and cyclic variability. A three-cylinder model was validated to experimental data collected by Achates Power and the grid was verified using an LES quality approach from the literature. The model was used to simulate port angles from 12 to 29 degrees at constant pressure and temperature boundary conditions. Results indicated that the higher bulk swirl ratio generated by larger port angles tends to trap more internal residuals. This effect on the scavenging performance, combined with the larger trapped swirl ratio, also has a significant impact on the combustion performance in a two-stroke engine. It was concluded that there exists a tradeoff of efficiency and emissions that must be considered when increasing the port angle in a uniflow two-stroke engine. 1. Introduction Two-stroke engines were developed in the 1800s and are commonly used in practice today for lightweight power applications such as motorcycles or handheld power tools, as well as large-bore low speed engines for stationary power and marine applications. Two-stroke engines provide the distinct advantage of higher torque/power output but present challenges due to its coupled intake and exhaust process. Four-stroke engines have the benefit of using two full piston strokes to induct intake charge and to expel exhaust gases. Controlling the trapped charge composition in a twostroke engine via a scavenging process is crucial for reliable and efficient engine operation.

33 ADVANCED PROPULSION SYSTEMS↗

SPR salt wall leaching experiments in lab-scale vessel : data report.

During cavern leaching in the Strategic Petroleum Reserve (SPR), injected raw water mixes with resident brine and eventually interacts with the cavern salt walls. This report provides a record of data acquired during a series of experiments designed to measure the leaching rate of salt walls in a labscale simulated cavern, as well as discussion of the data. These results should be of value to validate computational fluid dynamics (CFD) models used to simulate leaching applications. Three experiments were run in the transparent 89-cm (35-inch) ID diameter vessel previously used for several related projects. Diagnostics included tracking the salt wall dissolution rate using ultrasonics, an underwater camera to view pre-installed markers, and pre- and post-test weighing and measuring salt blocks that comprise the walls. In addition, profiles of the local brine/water conductivity and temperature were acquired at three locations by traversing conductivity probes to map out the mixing of injected raw water with the surrounding brine. The data are generally as expected, with stronger dissolution when the salt walls were exposed to water with lower salt saturation, and overall reasonable wall shape profiles. However, there are significant block-to-block variations, even between neighboring salt blocks, so the averaged data are considered more useful for model validation. The remedial leach tests clearly showed that less mixing and longer exposure time to unsaturated water led to higher levels of salt wall dissolution. The data for all three tests showed a dividing line between upper and lower regions, roughly above and below the fresh water injection point, with higher salt wall dissolution in all cases, and stronger (for remedial leach cases) or weaker (for standard leach configuration) concentration gradients above the dividing line.

02 PETROLEUM↗

Optimal gas cooling with minimal aero-opticaldistortion for next generation high-average-power lasers (Progress report, Year 2)

Next-generation lasers that combine high-peak-power ultrashort pulses with high repetition rates have the potential to efficiently deliver the high-average-power outputs required for inertial fusion energy generation, laser-based particle acceleration, and to generate compact secondary x- and 𝛾-ray radiation sources, among others. The combination of long gain length with high surface-to-volume ratio to remove residual heat makes gas-cooled multi-slab amplifier heads an inherently aperture- and average power scalable technology that enables this new class of solid-state lasers, and their thermal management becomes the most pressing technical challenge. As the index-of refraction depends on the gas density, heat removal from the slab surfaces unavoidably entails scattering of propagated light from regions of high temperature fluctuations. The requirement to maximize convective heat extraction from the gain medium under the constraint of minimum optical aberration of the beam renders amplifier slab cooling a technological challenge at the intersection of aero-optics, fluid-mechanics and heat transfer. The goal of this research is to leverage computational fluid dynamics and aero optics simulations of different levels of fidelity to devise a numerical modeling and optimization framework for gas-cooled multi-slab amplifiers. The project will be conducted in close collaboration with the Advanced Photon Technologies Group at Lawrence Livermore National Laboratory, where a gas-cooled test stand for laser materials and thermal management structures will be developed and installed. The final goal of the collaborative effort is to manufacture and benchmark a physical prototype of an numerically optimized amplifier head design. Measurement data on solid-state and thermo-optical distortions will be used for the validation of the numerical models. The key technical challenge in this multi-objective design problem is that of balancing optimal heat removal with minimal optical distortion. To facilitate computationally efficient design optimization and, at the same time, deepen our basic understanding of the interaction of light with turbulence, a complementary study that combines high and low-fidelity flow simulations and aero-optical models is proposed. Along the lines of these two objectives and solution strategies, the project is organized into two thrusts.

42 ENGINEERING↗

Direct numerical simulation of supercritical oxy-methane mixing layers with CO 2 substituted counterparts

Direct numerical simulations (DNS) of temporally developing, three dimensional, CH 4 /CO 2 , CH 4 /O 2 and CO 2 /O 2 mixing layers, are conducted at a supercritical pressure of 300 atm. To effectively model the supercritical regime, the employed formulation includes the compressible form of the governing equations, the cubic Peng-Robinson equation of state and a generalized formulation for heat and mass flux vectors derived from non-equilibrium thermodynamics and fluctuation theory. A linear inviscid stability analysis is also performed for each case, to determine its most unstable wavelength. Flow visualizations reveal the presence of high density gradient magnitude regions for all three mixing layers, with conditional averages indicating increased presence of heavier fluid species within these regions. No significant departures are observed from perfect gas behavior, with compressibility factors very close to unity for all three mixing cases. Applicability of presumed probability density function methods (PDF) is examined for the three supercritical mixing layers. An a priori analysis is also conducted to investigate various simplifying assumptions employed in modeling various subgrid scale (SGS) flux models. Two additional terms are identified in the large eddy simulations (LES) equations, the gradient of SGS contribution of pressure in the momentum equation and the gradient of SGS contribution of heat flux in energy equation, whose magnitudes are similar and comparable with their respective resolved terms. The performance of the scale similarity model to represent these additional terms is investigated. Lastly, the performance of Smagorinsky, gradient and scale similarity models are also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Airflow Simulations around OA Intake Louver with Electronic Velocity Sensors

It is important to control outdoor airflow rates into HVAC systems in terms of energy conservation and healthy indoor environment. Technologies are being developed to measure outdoor air (OA) flow rates through OA intake louvers on a real time basis. The purpose of this paper is to investigate the airflow characteristics through an OA intake louver numerically in order to provide suggestions for sensor installations. Airflow patterns are simulated with and without electronic air velocity sensors within cylindrical probes installed between louver blades or at the downstream face of the louver. Numerical results show quite good agreements with experimental data, and provide insights regarding measurement system design. The simulations indicate that velocity profiles are more spatially uniform at the louver outlet relative to between louver blades, that pressure drops imposed by the sensor bars are smaller with sensor bars at the louver outlet, and that placement of the sensor bars between louver blades substantially increases air velocities inside the louver. These findings suggest there is an advantage to placing the sensor bars at the louver outlet face.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗