Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Evaluation of a Surface Spill Operation to Return Adult Steelhead Overshoots Downstream of McNary Dam

This study, funded by the U.S. Army Corps of Engineers (USACE), was conducted by the Pacific Northwest National Laboratory to evaluate the efficacy of operating one Top Spill Weir (TSW) at McNary Dam outside the normal TSW operation dates for juvenile salmon passage. Of interest is whether the TSW is an effective downstream passage route for adult steelhead overshoots. Overshoots are fish which, having passed upstream at McNary Dam, must pass downstream to return to their natal stream to spawn. This report covers Fall (2019) and Spring (2020) study periods. The study design arranged the available 24 hours of TSW spill per week into weekly blocks with sub-blocks differentiated into day and night operations with TSW discharge periods of 4- and 8-hours duration. Hydroacoustic techniques were used to sample adult fish passage at the TSW and at turbine units 1 and 10. The experimental design contrasted TSW spill periods of differing duration and at different times of the day. The small number of fish detected passing the TSW, and the smaller number of fish detected passing the turbine units, were best suited to an ad hoc, exploratory approach to evaluating the effect of TSW spill. It is worthwhile to note that the operations data obtained for the fall study period had a greater than expected number of gaps and apparent anomalies that we believe were a result of how the data were aggregated. These problems are not particularly problematic for the present study, because the available data still provide a good indication of whether the TSW was operating at each point in time. TSW flows in both fall and spring data sets were able to be cleaned up using the established relationship between forebay elevation and TSW discharge rate. Additional cleanup of operations data would be needed, however, if more quantitative evaluation of dam-wide flow and passage relationships were needed. This study contrasted TSW spill periods of differing duration and at different times of the day. The small number of fish detected passing the TSW, and the smaller number of fish detected passing the turbine units were best suited to an ad hoc, exploratory approach to evaluating the effect of TSW spill. Spring adult steelhead passage numbers estimated using hydroacoustics were notably lower than during the fall study period, and that was consistent with our analysis of PIT tagged fish likely to be in the vicinity during each study period. Detections of fish in BlueView sampling areas upstream of the TSW and powerhouse were not correlated with detections of fish passing hydroacoustic sampling areas, which suggests that fish approaching the face of the dam can move around the forebay before passing. Other fish detected in the forebay in large numbers, such as shad, were able to be filtered out of steelhead passage counts and did not appear to be influencing hydroacoustic passage rate estimates. A pulse of passage at the initial TSW opening was weakly evident, but trends across 4- and 8-hour operational periods did not show a distinct decline in passage over time as TSW operation continued. Our findings do not indicate a reason to choose one 8-hour period over two 4-hour periods, or vice versa. This suggests that the duration of spill periods can be chosen based on operational or other considerations. Passage rates were consistently higher during the daytime TSW discharge periods, relative to nighttime TSW discharge periods. The experimental design of the current study used start times near dawn for day periods and near dusk for night periods.

59 BASIC BIOLOGICAL SCIENCES↗

Direct three-dimensional coherently scattered x-ray microtomography

Purpose: It has been shown that coherently scattered x rays can be used to discriminate and identify specific components in a mixture of low atomic weight materials. The authors demonstrated a new method of doing coherently scattered x-ray tomography with a thin sheet of x ray. Methods: A collimated x-ray fan-beam, a parallel polycapillary collimator, and a phantom consisting of several biocompatible materials of low attenuation-based contrast were used to investigate the feasibility of the method. Because of the particular experimental setup, only the phantom translation perpendicular to the x-ray beam is needed and, thus, there is no need of Radon-type tomographic reconstruction, except for the correction of the attenuation to the primary and scattered x rays, which was performed by using a conventional attenuation-based tomographic image data set. The coherent scatter image contrast changes with momentum transfer among component materials in the specimen were investigated with multiple x-ray sources with narrow bandwidth spectra generated with anode and filter combinations of Cu/Ni (8 keV), Mo/Zr (18 keV), and Ag/Pd (22 keV) and at multiple scatter angles by orienting the detector and polycapillary collimator at different angles to the illuminating x ray. Results: The contrast among different materials changes with the x-ray source energy and the angle at which the image was measured. The coherent scatter profiles obtained from the coherent scatter images are consistent with the published results. Conclusions: This method can be used to directly generate the three-dimensional coherent scatter images of small animal, biopsies, or other small objects with low atomic weight biological or similar synthetic materials with low attenuation contrast. With equipment optimized, submillimeter spatial resolution may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intelligent uranium fission converter for neutron production on the periphery of the nuclear reactor core (MARIA reactor in Swierk - Poland)

The multipurpose, high flux research reactor MARIA in Otwock - Swierk is an open-pool type, water and beryllium moderated and graphite reflected. There are two not occupied experimental H1 and H2 horizontal channels with complex of empty rooms beside them. Making use of these two channels is not in conflict with other research or commercial employing channels. They can work simultaneously, moreover commercial channels covers the cost of reactor working. Such conditions give beneficial possibility of creating epithermal neutron stand for researches in various field at the horizontal channel H2 of MARIA reactor (co-organization of research at H1 channel is additionally planned). At the front of experimental channels the neutron flux is strongly thermalized - neutrons with energies above 0.625 eV constitute only ∼2% of the total flux. This thermalized neutron flux will be used to achieve high flux of epithermal neutrons at the level of 2x10{sup 9} n cm{sup -2}s{sup -1} by uranium neutron converter (fast neutron production - conversion of reactor core thermal neutrons to fast neutrons - and then filtering, moderating and finally cutting of unwanted gamma radiation). The intelligent converter will be placed in the reactor pool, near the front of the H2 channel. It will replace one graphite block at the periphery of MARIA graphite reflector. The converter will consist of 20 fuel elements - low enriched uranium plates. A fuel plate will be a part which will measure 110 mm wide by 380 mm long and will consist of a thin layer of uranium sealed between two aluminium plates. These plates, once assembled, form the fuel element used in converter. The plates will be positioned vertically. There are several important requirements which should be taken into account at the converter design stage: -maximum efficiency of the converter for neutrons conversion, -cooling of the converter need to be integrated with the cooling circuit of the reactor pool and if needed equipped with self-cooling system (enhanced comparing to the cooling properties inherent with regular rector pool water flows), -proper cooling conditions can be ensured by an appropriate water flow, so the resistance to flow has to be optimised, -the requirement of the minimum resistance to water flow leads to the openwork design of the fuel element separator, which, on the other hand, has to be strong enough to ensure the needed strength for mechanical load due to the fuel weight and forces associated with the water flow, -the possibility of changing beam and flux qualities by rotating the converter or repositioning the converter plates by moving or replacing with another materials. In order to minimize the neutron activation of the fuel in the converter, the possibility was predicted to remove the converter and to replace it with an aluminium dummy for the time when the beam at the channel H2 is not used. This means that both, the converter and the dummy, have to be easily removable from the converter socket. There has to be also the place in the water pool, near the research stand or in technological pool, where the converter can be safely stored (this place have to be proper for operation with plates i.e. changing amount of plates). Thermal and neutron load of the fuel plates in the converter will be inhomogeneous. In order to equalize these loads, the converter should be designed in such way that it would be possible to change the order of fuel plates. Moreover replacing the amount of the plates gives the opportunity to obtain different fluxes of neutrons (quantitatively and qualitatively i.e. energetically). The project of the converter is based on Monte Carlo calculation concerning neutron production and on Computational Fluid Dynamics (CFD) i.e. modelling of converter for thermodynamical aspects. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pool water quality and prevalence of microbes in filter backwash from metro-Atlanta swimming pools

During the 2012 summer swim season, aquatic venue data and filter backwash samples were collected from 127 metro-Atlanta pools. Last-recorded water chemistry measures indicated 98% (157/161) of samples were from pools with ≥1 mg/L residual chlorine without stabilized chlorine or ≥2 mg/L with stabilized chlorine and 89% (144/161) had pH readings 7.2–7.8. These water quality parameters are consistent with the 2016 Model Aquatic Health Code (2nd edition) recommendations. We used previously validated real-time polymerase chain reaction assays for detection of seven enteric microbes, including Escherichia coli, and Pseudomonas aeruginosa. E. coli was detected in 58% (93/161) of samples, signifying that swimmers likely introduced fecal material into pool water. P. aeruginosa was detected in 59% (95/161) of samples, indicating contamination from swimmers or biofilm growth on surfaces. Cryptosporidium spp. and Giardia duodenalis were each detected in approximately 1% of samples. These findings indicate the need for aquatics staff, state and local environmental health practitioners, and swimmers to each take steps to minimize the risk of transmission of infectious pathogens.

59 BASIC BIOLOGICAL SCIENCES↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

THE HUBBLE SPACE TELESCOPE WIDE FIELD CAMERA 3 EARLY RELEASE SCIENCE DATA: PANCHROMATIC FAINT OBJECT COUNTS FOR 0.2-2 {mu}m WAVELENGTH

We describe the Hubble Space Telescope (HST) Wide Field Camera 3 (WFC3) Early Release Science (ERS) observations in the Great Observatories Origins Deep Survey (GOODS) South field. The new WFC3 ERS data provide calibrated, drizzled mosaics in the UV filters F225W, F275W, and F336W, as well as in the near-IR filters F098M (Y{sub s} ), F125W (J), and F160W (H) with 1-2 HST orbits per filter. Together with the existing HST Advanced Camera for Surveys (ACS) GOODS-South mosaics in the BViz filters, these panchromatic 10-band ERS data cover 40-50 arcmin{sup 2} at 0.2-1.7 {mu}m in wavelength at 0.''07-0.''15 FWHM resolution and 0.''090 Multidrizzled pixels to depths of AB {approx_equal} 26.0-27.0 mag (5{sigma}) for point sources, and AB {approx_equal} 25.5-26.5 mag for compact galaxies. In this paper, we describe (1) the scientific rationale, and the data taking plus reduction procedures of the panchromatic 10-band ERS mosaics, (2) the procedure of generating object catalogs across the 10 different ERS filters, and the specific star-galaxy separation techniques used, and (3) the reliability and completeness of the object catalogs from the WFC3 ERS mosaics. The excellent 0.''07-0.''15 FWHM resolution of HST/WFC3 and ACS makes star-galaxy separation straightforward over a factor of 10 in wavelength to AB {approx_equal} 25-26 mag from the UV to the near-IR, respectively. Our main results are: (1) proper motion of faint ERS stars is detected over 6 years at 3.06 {+-} 0.66 mas year{sup -1} (4.6{sigma}), consistent with Galactic structure models; (2) both the Galactic star counts and the galaxy counts show mild but significant trends of decreasing count slopes from the mid-UV to the near-IR over a factor of 10 in wavelength; (3) combining the 10-band ERS counts with the panchromatic Galaxy and Mass Assembly survey counts at the bright end (10 mag {approx}< AB {approx}< 20 mag) and the Hubble Ultra Deep Field counts in the BVizY{sub s}JH filters at the faint end (24 mag {approx}< AB {approx}< 30 mag) yields galaxy counts that are well measured over the entire flux range 10 mag {approx}< AB {approx}< 30 mag for 0.2-2 {mu}m in wavelength; (4) simple luminosity+density evolution models can fit the galaxy counts over this entire flux range. However, no single model can explain the counts over this entire flux range in all 10 filters simultaneously. More sophisticated models of galaxy assembly are needed to reproduce the overall constraints provided by the current panchromatic galaxy counts for 10 mag {approx}< AB {approx}< 30 mag over a factor of 10 in wavelength.

79 ASTRONOMY AND ASTROPHYSICS↗

Fine‐root traits are linked to species dynamics in a successional plant community

Abstract Despite the importance of fine roots for the acquisition of soil resources such as nitrogen and water, the study of linkages between traits and both population and community dynamics remains focused on aboveground traits. We address this gap by investigating associations between belowground traits and metrics of species dynamics. Our analysis included 85 species from a long‐term data set on the transition from old field to forest in eastern North America (the Buell‐Small Succession Study) and the new Fine‐Root Ecology Database. Given the prominent roles of life form (woody vs. non‐woody) and species origin (native vs. exotic) in defining functional relationships, we also assessed whether traits or their relationships with species dynamics differed for these groups. Species that reached their peak abundance early in succession had fine‐root traits corresponding to resource acquisitive strategies (i.e., they were thinner, less dense, and had higher nitrogen concentrations) while species that peaked progressively later had increasingly conservative strategies. In addition to having more acquisitive root traits than native species, exotics diverged from the above successional trend, having consistently thinner fine roots regardless of the community context. Species with more acquisitive fine‐root morphologies typically had faster rates of abundance increase and achieved their maximal rates in fewer years. Decreasing soil nutrient availability and increasing belowground competition may become increasingly strong filters in successional communities, acting on root traits to promote a transition from acquisitive to conservative foraging. However, disturbances that increase light and soil resource availability at local scales may allow acquisitive species, especially invasive exotics, to continue colonizing late into the community transition to forest.

Caplan, Joshua S.↗

Quantification of Mercury Bioavailability for Methylation Using Diffusive Gradient in Thin-Film Samplers

Here, mercury-contaminated sediment and water contain various Hg species, with a small fraction available for microbial conversion to the bioaccumulative neurotoxin monomethylmercury (MeHg). Quantification of this available Hg pool is needed to prioritize sites for risk management. This study compared the efficacy of diffusive gradient in thin-film (DGT) passive samplers to a thiol-based selective extraction method with glutathione (GSH) and conventional filtration (<0.2 μm) as indicators of Hg bioavailability. Anaerobic sediment slurry microcosms were amended with isotopically labeled inorganic Hg “endmembers” (dissolved Hg 2+ , Hg-humic acid, Hg-sorbed to FeS, HgS nanoparticles) with a known range of bioavailability and methylation potentials. Net MeHg production (expressed as percent of total Hg as MeHg) over 1 week correlated with mass accumulation of Hg endmembers on the DGTs and only sometimes correlated with the 0.2 μm filter passing Hg fraction and the GSH-extractable Hg fraction. These results suggest for the first time that inorganic Hg uptake in DGTs may indicate bioavailability for methylating microbes. Moreover, the methylating microbial community assessed by hgcA gene abundance was not always consistent with methylation rates between the experiments, indicating that knowledge of the methylating community should target the transcript or protein level. Altogether, these results suggest that DGTs could be used to quantify the bioavailable Hg fraction as part of a method to assess net MeHg production potential in the environment.

54 ENVIRONMENTAL SCIENCES↗

Optical generation of a spatially variant two-dimensional lattice structure by using a phase only spatial light modulator

We propose a simple and straightforward method to generate spatially variant lattice structures by optical interference lithography method. Using this method, it is possible to independently vary the orientation and period of the two-dimensional lattice. The method consists of two steps which are: numerical synthesis of corresponding phase mask by employing a two-dimensional integrated gradient calculations and experimental implementation of synthesized phase mask by making use of a phase only spatial light modulator in an optical 4f Fourier filtering setup. As a working example, we provide the experimental fabrication of a spatially variant square lattice structure which has the possibility to guide a Gaussian beam through a 90° bend by photonic crystal self-collimation phenomena. The method is digitally reconfigurable, is completely scalable, and could be extended to other kind of lattices as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Metrics for Intercomparison of Remapping Algorithms (MIRA) protocol applied to Earth system models

Abstract. Strongly coupled nonlinear phenomena such as those described by Earth system models (ESMs) are composed of multiple component models with independent mesh topologies and scalable numerical solvers. A common operation in ESMs is to remap or interpolate component solution fields defined on their computational mesh to another mesh with a different combinatorial structure and decomposition, e.g., from the atmosphere to the ocean, during the temporal integration of the coupled system. Several remapping schemes are currently in use or available for ESMs. However, a unified approach to compare the properties of these different schemes has not been attempted previously. We present a rigorous methodology for the evaluation and intercomparison of remapping methods through an independently implemented suite of metrics that measure the ability of a method to adhere to constraints such as grid independence, monotonicity, global conservation, and local extrema or feature preservation. A comprehensive set of numerical evaluations is conducted based on a progression of scalar fields from idealized and smooth to more general climate data with strong discontinuities and strict bounds. We examine four remapping algorithms with distinct design approaches, namely ESMF Regrid (Hill et al., 2004), TempestRemap (Ullrich and Taylor, 2015), generalized moving least squares (GMLS) (Trask and Kuberry, 2020) with post-processing filters, and WLS-ENOR (Li et al., 2020). By repeated iterative application of the high-order remapping methods to the test fields, we verify the accuracy of each scheme in terms of their observed convergence order for smooth data and determine the bounded error propagation using challenging, realistic field data on both uniform and regionally refined mesh cases. In addition to retaining high-order accuracy under idealized conditions, the methods also demonstrate robust remapping performance when dealing with non-smooth data. There is a failure to maintain monotonicity in the traditional L2-minimization approaches used in ESMF and TempestRemap, in contrast to stable recovery through nonlinear filters used in both meshless GMLS and hybrid mesh-based WLS-ENOR schemes. Local feature preservation analysis indicates that high-order methods perform better than low-order dissipative schemes for all test cases. The behavior of these remappers remains consistent when applied on regionally refined meshes, indicating mesh-invariant implementations. The MIRA intercomparison protocol proposed in this paper and the detailed comparison of the four algorithms demonstrate that the new schemes, namely GMLS and WLS-ENOR, are competitive compared to standard conservative minimization methods requiring computation of mesh intersections. The work presented in this paper provides a foundation that can be extended to include complex field definitions, realistic mesh topologies, and spectral element discretizations, thereby allowing for a more complete analysis of production-ready remapping packages.

58 GEOSCIENCES↗

A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scanner assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.

43 PARTICLE ACCELERATORS↗

Second Season QUIET Observations: Measurements of the CMB Polarization Power Spectrum at 95 GHz

The Q/U Imaging ExperimenT (QUIET) has observed the cosmic microwave background (CMB) at 43 and 95GHz. The 43-GHz results have been published in QUIET Collaboration et al. (2011), and here we report the measurement of CMB polarization power spectra using the 95-GHz data. This data set comprises 5337 hours of observations recorded by an array of 84 polarized coherent receivers with a total array sensitivity of 87 {mu}K{radical}s. Four low-foreground fields were observed, covering a total of {approx} 1000 square degrees with an effective angular resolution of 12'.8, allowing for constraints on primordial gravitational waves and high-signal-to-noise measurements of the E-modes across three acoustic peaks. The data reduction was performed using two independent analysis pipelines, one based on a pseudo-C{ell} (PCL) cross-correlation approach, and the other on a maximum-likelihood (ML) approach. All data selection criteria and filters were modified until a predefined set of null tests had been satisfied before inspecting any non-null power spectrum. The results derived by the two pipelines are in good agreement. We characterize the EE, EB and BB power spectra between {ell} = 25 and 975 and find that the EE spectrum is consistent with {Lambda}CDM, while the BB power spectrum is consistent with zero. Based on these measurements, we constrain the tensor-to-scalar ratio to r = 1.1{sup +0.9}{sub -0.8} (r < 2.8 at 95% C.L.) as derived by the ML pipeline, and r = {sup +0.9}{sub -0.8} (r < 2.7 at 95% C.L.) as derived by the PCL pipeline. In one of the fields, we find a correlation with the dust component of the Planck Sky Model, though the corresponding excess power is small compared to statistical errors. Finally, we derive limits on all known systematic errors, and demonstrate that these correspond to a tensor-to-scalar ratio smaller than r = 0.01, the lowest level yet reported in the literature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-rays from a microsecond X-pinch

The characteristics of x-rays emitted by X-pinches driven by discharging a current of ∼320 kA with a quarter period of 1 μs in crossed 25 μm wires have been investigated. The x-ray emissions are studied using filtered silicon photodiodes, diamond radiation detectors, and pinhole cameras. The results show that predominantly x-rays from the microsecond X-pinch tend to be emitted in two distinct sets of bursts. The first is predominantly “soft,” i.e., with photon energy hν < 5 keV, followed by a second set of bursts beginning up to 100 ns following the initial bursts, and usually consisting of higher photon energies. Our results show, however, that the x-ray emissions do not contain a significant component with hν > 10 keV as might be expected from electron beam activity within the plasma or from the X-pinch diode. High-resolution images obtained with the observed x-rays suggest a well-defined small source of soft x-rays that demonstrates the potential of the microsecond X-pinch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DWPF DECON FRIT: SUMP AND SLURRY SOLIDS ANALYSIS

The Savannah River National Laboratory (SRNL) has been requested to perform analyses on samples of the Defense Waste Processing Facility (DWPF) decon frit slurry (i.e., supernate samples and sump solid samples). Four 1-L liquid slurry samples were provided to SRNL by Savannah River Remediation (SRR) from the 'front-end' decon activities. Additionally, two 1-L sump solids samples were provided to SRNL for compositional and physical analysis. In this report, the physical and chemical characterization results of the slurry solids and sump solids are reported. Crawford et al. (2010) provide the results of the supernate analysis. The results of the sump solids are reported on a mass basis given the samples were essentially dry upon receipt. The results of the slurry solids were converted to a volume basis given approximately 2.4 grams of slurry solids were obtained from the {approx}4 liters of liquid slurry sample. Although there were slight differences in the analytical results between the sump solids and slurry solids the following general summary statements can be made. Slight differences in the results are also captured for specific analysis. (1) Physical characterization - (a) SEM/EDS analysis suggested that the samples were enriched in Li and Si (B and Na not detectable using the current EDS system) which is consistent with two of the four principle oxides of Frit 418 (B{sub 2}O{sub 3}, Na{sub 2}O, Li{sub 2}O and SiO{sub 2}). (b) SEM/EDS analysis also identified impurities which were elementally consistent with stainless steel (i.e., Fe, Ni, Cr contamination). (c) XRD results indicated that the sump solids samples were amorphous which is consistent with XRD results expected for a Frit 418 based sample. (d) For the sump solids, SEM/EDS analysis indicated that the particle size of the sump solids were consistent with that of an as received Frit 418 sample from a current DWPF vendor. (e) For the slurry solids, SEM/EDS analysis indicated that the particle size range of the slurry solids was much broader than compared to the sump solids. More specifically, there were significantly more fines in the slurry solids as compared to the sump solids. (f) PSD results indicated that > 99% of both the sump and slurry solids were less than 350 microns. The PSD results also supported SEM/EDS analysis that there were significantly more fines in the slurry solids as compared to the sump solids. (2) Weight Percent Solids - Based on the measured supernate density and mass of insoluble solids (2.388 grams) filtered from the four liters of liquid slurry samples, the weight percent insoluble solids was estimated to be 0.060 wt%. This level of insoluble solids is higher than the ETP WAC limit of 100 mg/L, or 0.01 wt% which suggests a separation technology of some type would be required. (3) Chemical Analysis - (a) Elemental results from ICP-ES analysis indicated that the sump solids and slurry were very consistent with the nominal composition of Frit 418. There were other elements identified by ICP analysis which were either consistent with the presence of stainless steel (as identified by SEM/EDS analysis) or impurities that have been observed in 'as received' Frit 418 from the vendor. (b) IC anion analysis of the sump solids and slurry solids indicated all of the species were less than detection limits. (c) Radionuclide analysis of the sump solids also indicated that most of the analytes were either at or below the detection limits. (d) Organic analysis of the sump solids and slurry solids indicated all of the species were less than detection limits. It should be noted that the results of this study may not be representative of future decon frit solutions or sump/slurry solids samples. Therefore, future DWPF decisions regarding the possible disposal pathways for either the aqueous or solid portions of the Decon Frit system need to factor in the potential differences. More specifically, introduction of a different frit or changes to other DWPF flowsheet unit operations (e.g., different sludge batch or coupling with other process streams) may impact not only the results but also the conclusions regarding acceptability with respect to the ETF WAC limits or other alternative disposal options.

36 MATERIALS SCIENCE↗

Improvements in dose accuracy delivered with static-MLC IMRT on an integrated linear accelerator control system

Purpose: Dose accuracy has been shown to vary with dose per segment and dose rate when delivered with static multileaf collimator (SMLC) intensity modulated radiation therapy (IMRT) by Varian C-series MLC controllers. The authors investigated the impact of monitor units (MUs) per segment and dose rate on the dose delivery accuracy of SMLC-IMRT fields on a Varian TrueBeam linear accelerator (LINAC), which delivers dose and manages motion of all components using a single integrated controller. Methods: An SMLC sequence was created consisting of ten identical 10 x 10 cm{sup 2} segments with identical MUs. Beam holding between segments was achieved by moving one out-of-field MLC leaf pair. Measurements were repeated for various combinations of MU/segment ranging from 1 to 40 and dose rates of 100-600 MU/min for a 6 MV photon beam (6X) and dose rates of 800-2400 MU/min for a 10 MV flattening-filter free photon (10XFFF) beam. All measurements were made with a Farmer (0.6 cm{sup 3}) ionization chamber placed at the isocenter in a solid-water phantom at 10 cm depth. The measurements were performed on two Varian LINACs: C-series Trilogy and TrueBeam. Each sequence was delivered three times and the dose readings for the corresponding segments were averaged. The effects of MU/segment, dose rate, and LINAC type on the relative dose variation ({Delta}{sub i}) were compared using F-tests ({alpha} = 0.05). Results: On the Trilogy, large {Delta}{sub i} was observed in small MU segments: at 1 MU/segment, the maximum {Delta}{sub i} was 10.1% and 57.9% at 100 MU/min and 600 MU/min, respectively. Also, the first segment of each sequence consistently overshot ({Delta}{sub i} > 0), while the last segment consistently undershot ({Delta}{sub i} < 0). On the TrueBeam, at 1 MU/segment, {Delta}{sub i} ranged from 3.0% to 4.5% at 100 and 600 MU/min; no obvious overshoot/undershoot trend was observed. F-tests showed statistically significant difference [(1 - {beta}) =1.0000] between the Trilogy and the TrueBeam up to 10 MU/segment, at all dose rates greater than 100 MU/min. The linear trend of decreasing dose accuracy as a function of increasing dose rate on the Trilogy is no longer apparent on TrueBeam, even for dose rates as high as 2400 MU/min. Dose inaccuracy averaged over all ten segments in each beam delivery sequence was larger for Trilogy than TrueBeam, with the largest discrepancy (0.2% vs 3%) occurring for 1 MU/segment beams at both 300 and 600 MU/min. Conclusions: Earlier generations of Varian LINACs exhibited large dose variations for small MU segments in SMLC-IMRT delivery. Our results confirmed these findings. The dose delivery accuracy for SMLC-IMRT is significantly improved on TrueBeam compared to Trilogy for every combination of low MU/segment (1-10) and high dose rate (200-600 MU/min), in part due to the faster sampling rate (100 vs 20 Hz) and enhanced electronic integration of the MLC controller with the LINAC. SMLC-IMRT can be implemented on TrueBeam with higher dose accuracy per beam ({+-}0.2% vs {+-}3%) than previous generations of Varian C-series LINACs for 1 MU/segment delivered at 600 MU/min).

61 RADIATION PROTECTION AND DOSIMETRY↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

Recommendations for harmonized reporting of radiation Dosimetry by adoption of Compatibility in Irradiation Research Protocols Expert Roundtable (CIRPER)

Here, in radiobiology, radiation physics, and related areas, there is growing interest in transitioning from cesium-based irradiators to X-ray technologies. Therefore, it makes it imperative for reproducibility purposes, for researchers to provide specifications regarding device parameters, machine calibration details, and experimental setup when innovative X-ray technology is being employed. Several groups have already identified a glaring lack in completeness of critical information on experimental setups, equipment, and physical parameters in published radiation biology studies. The Alternative Technologies Meta Study Report by Brookhaven National Laboratory (BNL) examined 456 manuscripts published between 2017-2021. Only 64 of the reviewed studies (14.0%) consistently reported methods that could allow for replication of their studies. However, 85% provided information on the manufacturer, the irradiator model and the absorbed radiation dose. Approximately 66% provided information on the energy spectra and the dose rate, but only one third disclosed the filter used. Less than 15% of the reviewed studies reported information on calibration and field geometry, specifically field size and distance from source, which are critical parameters in determining the absorbed radiation dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Can radiomics features be reproducibly measured from CBCT images for patients with non-small cell lung cancer?

Purpose: Increasing evidence suggests radiomics features extracted from computed tomography (CT) images may be useful in prognostic models for patients with nonsmall cell lung cancer (NSCLC). This study was designed to determine whether such features can be reproducibly obtained from cone-beam CT (CBCT) images taken using medical Linac onboard-imaging systems in order to track them through treatment. Methods: Test-retest CBCT images of ten patients previously enrolled in a clinical trial were retrospectively obtained and used to determine the concordance correlation coefficient (CCC) for 68 different texture features. The volume dependence of each feature was also measured using the Spearman rank correlation coefficient. Features with a high reproducibility (CCC > 0.9) that were not due to volume dependence in the patient test-retest set were further examined for their sensitivity to differences in imaging protocol, level of scatter, and amount of motion by using two phantoms. The first phantom was a texture phantom composed of rectangular cartridges to represent different textures. Features were measured from two cartridges, shredded rubber and dense cork, in this study. The texture phantom was scanned with 19 different CBCT imagers to establish the features’ interscanner variability. The effect of scatter on these features was studied by surrounding the same texture phantom with scattering material (rice and solid water). The effect of respiratory motion on these features was studied using a dynamic-motion thoracic phantom and a specially designed tumor texture insert of the shredded rubber material. The differences between scans acquired with different Linacs and protocols, varying amounts of scatter, and with different levels of motion were compared to the mean intrapatient difference from the test-retest image set. Results: Of the original 68 features, 37 had a CCC >0.9 that was not due to volume dependence. When the Linac manufacturer and imaging protocol were kept consistent, 4–13 of these 37 features passed our criteria for reproducibility more than 50% of the time, depending on the manufacturer-protocol combination. Almost all of the features changed substantially when scatter material was added around the phantom. For the dense cork, 23 features passed in the thoracic scans and 11 features passed in the head scans when the differences between one and two layers of scatter were compared. Using the same test for the shredded rubber, five features passed the thoracic scans and eight features passed the head scans. Motion substantially impacted the reproducibility of the features. With 4 mm of motion, 12 features from the entire volume and 14 features from the center slice measurements were reproducible. With 6–8 mm of motion, three features (Laplacian of Gaussian filtered kurtosis, gray-level nonuniformity, and entropy), from the entire volume and seven features (coarseness, high gray-level run emphasis, gray-level nonuniformity, sum-average, information measure correlation, scaled mean, and entropy) from the center-slice measurements were considered reproducible. Conclusions: Some radiomics features are robust to the noise and poor image quality of CBCT images when the imaging protocol is consistent, relative changes in the features are used, and patients are limited to those with less than 1 cm of motion.

60 APPLIED LIFE SCIENCES↗