Search NASA⌕ Search

SEARCH · Search NASA

Results for “continuous selections”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Development, refinement, and testing of a short term solar flare prediction algorithm

During the period included in this report, the expenditure of time and effort, and progress toward performance of the tasks and accomplishing the goals set forth in the two year research grant proposal, consisted primarily of calibration and analysis of selected data sets. The heliographic limits of 30 degrees from central meridian were continued. As previously reported, all analyses are interactive and are performed by the Principal Investigator. It should also be noted that the analysis time involved by the Principal Investigator during this reporting period was limited, partially due to illness and partially resulting from other uncontrollable factors. The calibration technique (as developed by MSFC solar scientists), incorporates sets of constants which vary according to the wave length of the observation data set. One input constant is then varied interactively to correct for observing conditions, etc., to result in a maximum magnetic field strength (in the calibrated data), based on a separate analysis. There is some insecurity in the methodology and the selection of variables to yield the most self-consistent results for variable maximum field strengths and for variable observing/atmospheric conditions. Several data sets were analyzed using differing constant sets, and separate analyses to differing maximum field strength - toward standardizing methodology and technique for the most self-consistent results for the large number of cases. It may be necessary to recalibrate some of the analyses, but the sc analyses are retained on the optical disks and can still be used with recalibration where necessary. Only the extracted parameters will be changed.

Smith, Jesse B., Jr.↗

Radiological risk assessment of environmental radon

Measurements of radon gas ({sup 222}Rn) in the environmental are important to assess indoor air quality and to study the potential risk to human health. Generally known that exposure to radon is considered the second leading cause of lung cancer after smoking. The environmental radon concentration depends on the {sup 226}Ra concentration, indoor atmosphere, cracking on rocks and building materials. This study was carried out to determine the indoor radon concentration from selected samples of tin tailings (amang) and building materials in an airtight sealed homemade radon chamber. The radiological risk assessment for radon gas was also calculated based on the annual exposure dose, effective dose equivalent, radon exhalation rates and fatal cancer risk. The continuous radon monitor Sun Nuclear model 1029 was used to measure the radon concentration emanates from selected samples for 96 hours. Five types of tin tailings collected from Kampar, Perak and four samples of building materials commonly used in Malaysia dwellings or building constructions were analysed for radon concentration. The indoor radon concentration determined in ilmenite, monazite, struverite, xenotime and zircon samples varies from 219.6 ± 76.8 Bq m{sup −3} to 571.1 ± 251.4 Bq m{sup −3}, 101.0 ± 41.0 Bq m{sup −3} to 245.3 ± 100.2 Bq m{sup −3}, 53.1 ± 7.5 Bq m{sup −3} to 181.8 ± 9.7 Bq m{sup −3}, 256.1 ± 59.3 Bq m{sup −3} to 652.2 ± 222.2 Bq m{sup −3} and 164.5 ± 75.9 Bq m{sup −3} to 653.3 ± 240.0 Bq m{sup −3}, respectively. Whereas, in the building materials, the radon concentration from cement brick, red-clay brick, gravel aggregate and cement showed 396.3 ± 194.3 Bq m{sup −3}, 192.1 ± 75.4 Bq m{sup −3}, 176.1 ± 85.9 Bq m{sup −3} and 28.4 ± 5.7 Bq m{sup −3}, respectively. The radon concentration in tin tailings and building materials were found to be much higher in xenotime and cement brick samples than others. All samples in tin tailings were exceeded the action level for radon gas of 148 Bq m{sup −3} proposed by EPA except monazite 0.15 kg, struverite 0.15 kg and 0.25 kg. Whereas, all building material samples have exceeded the radon concentration in concrete and building materials of 3 to 7 Bq m{sup −3} estimated by ICRP. The annual effective dose, effective dose equivalent, and radon exhalation rates in tin tailings were calculated to be in the range of 2.47 to 11.46 mSv, 5.94 to 1090.56 mSv y{sup −1}, and 0.23 to 1.18 mBq kg{sup −1} h{sup −1}. For building materials, the calculated risk assessment of the annual effective dose, effective dose equivalent, radon exhalation rates and fatal cancer risk were 0.72 to 10.00 mSv, 1.73 to 24.00 mSv y{sup −1}, 0.010 to 0.06 mBq kg{sup −1} h{sup −1} and 40 to 550 chances of persons will suffer the cancer per million (1 × 10{sup 6}), respectively.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface emitting multi-wavelength array of single frequency quantum cascade lasers

We present a surface emitting laser array design based on distributed Bragg reflectors together with a second order extractor, providing a deterministic mode selection mechanism. The technology is implemented as a buried heterostructure compatible with continuous-wave operation and low dissipation. A proof of principle featured 10 regularly spaced single mode devices with a coverage of 175 cm{sup −1} in the 8–10 μm wavelength range and milliwatt output powers with a far-field pattern full-width half-maximum of 8.3° in the longitudinal direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of Linear Octenes from Oligomerization of 1-Butene over Carbon-Supported Cobalt Catalysts

Here, linear octenes were produced in high (70–85%) selectivity from oligomerization of liquid 1-butene using carbon-supported cobalt oxide catalysts in a continuous flow reactor. The liquid products were characterized by two-dimensional gas chromatography–mass spectrometry. Above 95% of the oligomers were C8 olefins, with the other products primarily being branched C12 olefins. The linear octene products at a conversion of 9.77% decreased in selectivity according to 3-octene > trans-2-octene > cis-2-octene > 4-octene. Methyl-heptenes including trans/cis-5-methyl-2-heptene > trans/cis-5-methyl-3-heptene > trans-3-methyl-2-heptene (at the lowest conversion) were the other major products summing to 15.6%. The selectivity of linear octenes decreased from 84 to 78% as the conversion increased from 10% to 29%. The product distribution suggests the reaction pathway involves a head-to-head coupling of two 1-butene molecules to form internal linear octenes. Head-to-tail coupling of two 1-butene molecules or a coupling between 1-butene and 2-butene forms the observed methyl-heptenes. The rate of head-to-head coupling is higher than the rate of head-to-tail or the rate of 1-butene to 2-butene coupling as indicated by the higher selectivity of linear octenes. The activated catalyst contained both Co 3 O 4 and CoO as confirmed by X-ray diffraction (XRD), in situ Raman spectroscopy, and X-ray absorption spectroscopy. The cobalt oxide particle size was estimated to be between 5 and 10 nm by high-resolution transmission electron microscopy and XRD. The Co 3 O 4 /CoO ratio decreased with increasing pretreatment temperature. Metallic cobalt, which has a low catalytic activity, formed at 550 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using Natural Selection to Explore the Adaptive Potential of Chlamydomonas reinhardtii

Improving feedstock is critical to facilitate the commercial utilization of algae, in particular in open pond systems where, due to the presence of competitors and pests, high algal growth rates and stress tolerance are beneficial. Here we raised laboratory cultures of the model alga Chlamydomonas reinhardtii under serial dilution to explore the potential of crop improvement using natural selection. The alga was evolved for 1,880 generations in liquid medium under continuous light (EL population). At the end of the experiment, EL cells had a growth rate that was 35% greater than the progenitor population (PL). The removal of acetate from the medium demonstrated that EL growth enhancement largely relied on efficient usage of this organic carbon source. Genome re-sequencing uncovered 1,937 polymorphic DNA regions in the EL population with 149 single nucleotide polymorphisms resulting in amino acid substitutions. Transcriptome analysis showed, in the EL population, significant up regulation of genes involved in protein synthesis, the cell cycle and cellular respiration, whereas the DNA repair pathway and photosynthesis were down regulated. Like other algae, EL cells accumulated neutral lipids under nitrogen depletion. Our work demonstrates transcriptome and genome-wide impacts of natural selection on algal cells and points to a useful strategy for strain improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Landsat Instrument Suite (LandIS) Sensor Design for the Landsat 10 Mission

Landsat 10 will be the upcoming mission in the 50+ year Landsat series of Earth observation platforms. The centerpiece of the observatory will be a super-spectral imager known as the Landsat Instrument Suite (LandIS). The sensor will feature 26 spectral channels from the visible through near-, short-wave, and thermal infrared wavelengths with spatial resolutions of 10, 20, and 60 meters on the ground, depending on the band. These enhancements over the legacy Landsat instruments will ensure data continuity with the existing archive and will expand upon the core Landsat capabilities to enable new applications in Earth science. After a competitive procurement, NASA selected the design submitted by the Raytheon Company for the LandIS instrument. The innovative Raytheon instrument concept utilizes an advanced whiskbroom architecture to fulfill the strict radiometric, spatial, and geometric image quality requirements demanded by the Landsat 10 mission and fits within restrictive mass, volume, and power constraints. The instrument will continue the Landsat directive to image all daylit land and near-shore water areas, along with select nighttime imaging. On-board calibration source data will ensure high radiometric and geometric accuracy and stability consistent with previous missions to enable continuity in data products available to users. This paper discusses the driving requirements for LandIS and provides a description of the chosen design and operations concept of the instrument.

Requirements↗

Continuous enzymatic hydrolysis of lignocellulosic biomass in a membrane-reactor system: Continuous enzymatic hydrolysis of lignocellulosic biomass in a membrane-reactor system

Converting abundant lignocellulosic biomass to sugars as fungible precursors to fuels and chemicals has the potential to diversify the supply chain for those products, but further process improvements are needed to achieve economic viability. In the current work, process intensification of the key enzymatic hydrolysis unit operation is demonstrated by means of a membrane reactor system that was operated continuously. Lignocellulosic biomass (pretreated corn stover) and buffered enzyme solution were fed to a continuously stirred-tank reactor, and clarified sugar solution was withdrawn via a commercial tubular ultrafiltration membrane. The membrane permeance decline and membrane cleaning efficacy were studied and did not vary significantly when increasing fraction insoluble solids (FIS) from 2.5% to 5%. Continuous enzymatic hydrolysis was successfully operated for more than 80 h. A model for the reactor system was able to predict dynamic behavior that was in reasonable agreement with experimental results. The modeled technical performance of anticipated commercial batch and continuous enzymatic hydrolysis processes were compared and showed that continuous operation would provide at least twice the volumetric productivity for the conditions studied. Further improvements are anticipated by better membrane selection and by increasing FIS.

09 BIOMASS FUELS↗

Streaked x-ray spectrometer having a discrete selection of Bragg geometries for Omega

The streaked x-ray spectrometer (SXS) is used with streak cameras [D. H. Kalantar, P. M. Bell, R. L. Costa, B. A. Hammel, O. L. Landen, T. J. Orzechowski, J. D. Hares, and A. K. L. Dymoke-Bradshaw, in 22nd International Congress on High-Speed Photography and Photonics, edited by D. L. Paisley and A. M. Frank (SPIE, Bellingham, WA, 1997), Vol. 2869, p. 680] positioned with a ten-inch manipulator on OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495 (1997)] and OMEGA EP [L. J. Waxer et al., Presented at CLEO/QELS 2008, San Jose, CA, 4-9 May 2008 (Paper JThB1)] for time-resolved, x-ray spectroscopy of laser-produced plasmas in the 1.4- to 20-keV photon-energy range. These experiments require measuring a portion of this photon-energy range to monitor a particular emission or absorption feature of interest. The SXS relies on a pinned mechanical reference system to create a discrete set of Bragg reflection geometries for a variety of crystals. A wide selection of spectral windows is achieved accurately and efficiently using this technique. It replaces the previous spectrometer designs that had a continuous Bragg angle adjustment and required a tedious alignment calibration procedure. The number of spectral windows needed for the SXS was determined by studying the spectral ranges selected by OMEGA users over the last decade. These selections are easily configured in the SXS using one of the 25 discrete Bragg reflection geometries and one of the six types of Bragg crystals, including two curved crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry Annual Report

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science.

59 BASIC BIOLOGICAL SCIENCES↗

National User Resource for Biological Accelerator Mass Spectrometry

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National User Resource for Biological Accelerator Mass Spectrometry (Final Report)

The National User Resource for Biological Accelerator Mass Spectrometry (User Resource) will provide isotopic analysis (primarily radiocarbon or 14C) by accelerator mass spectrometry (AMS) for NIH- funded researchers across the United States and will be the only User Resource of its type in the United States. The User Resource will provide measurement capability and expertise to a research community that requires highly sensitive, quantitative isotope analyses. Since commissioning a new accelerator mass spectrometer in June 2014, we have measured over 4000 samples a year for collaborators and service users. The User Resource will enable us to continue to meet these research needs, as well as provide for new users whose research programs would benefit from AMS as a measurement tool. The User Resource’s forte will be ultra-high sensitivity quantitation of radiocarbon and selected other radioisotopes for research studies where isotopes are required. Radioisotope labeling studies have been and will continue to be an important tool for addressing many complex biomedical science problems. AMS is a specialized and unique type of mass spectrometry that provides absolute quantitation of radiocarbon and other relevant radioisotopes with extreme sensitivity, having limits of detection in real samples on the order of a few attomol/mg of sample at measurement precisions of ~3%. It is the only instrumental method capable of quantifying radioisotope-labeled agents routinely in real-world samples with such precision and sensitivity. The sensitivity of AMS allows for the quantification of radiolabeled metabolites in extremely complex matrices of cells and organisms at very low concentrations and in small samples. AMS allows studies to be conducted without perturbing metabolism leading to more relevant quantification of metabolic rates and pathways. In addition, it enables quantification of pharmacokinetic and metabolic properties of toxicants at environmentally relevant concentrations in model systems as well as the ability to quantify pharmacokinetics and other molecular endpoints directly in humans. Such quantitative assessments can 1) improve risk assessment for toxicants, 2) address safety and efficacy considerations for therapeutic entities, 3) deepen understanding of xenobiotic and intermediary metabolism, 4) help understand the interactions between critical molecular pathways, and 5) improve efforts to model and predict various metabolic and biological states. These capabilities have been applied in a number of areas including research in carcinogenesis, toxicology, nutrition, pharmacology/drug development and basic biological science. As a NIGMS National Resource the National User Resource for Biological Accelerator Mass Spectrometry will help NIH funded scientists achieve a deeper understanding of the etiology of human health concerns by (1) enabling the quantification of pharmacokinetics and other molecular endpoints directly in humans; (2) offering the ability to conduct quantitative studies using biologics such as proteins or lipids, and thereby reducing the amount of radioisotope usage in biomedical labs; and (3) enabling more relevant studies of metabolic pathways in health and disease through the use of much lower, more biologically-relevant, concentrations of metabolic substrates in cells and intact organisms. Such studies support NIGMS’s basic biomedical research areas that contribute to the understanding of fundamental cellular and physiological principles and enable research supported by the Biophysics, Biomedical Technology, and Computational Biosciences (BBCB); Genetics and Molecular, Cellular, and Developmental Biology (GMCDB); Pharmacology, Physiology, Biological Chemistry (PPBC) and Training, Workforce Development, and Diversity (TWD) Divisions. Over the next five years, our goals are to: 1. Improve the efficiency of operation for AMS measurements through installation of new interfaces to our AMS systems, technical modifications to improve gas accepting ion source efficiency and upgrading our data analysis software for improved ease of use and data reporting. 2. Increase the accessibility and visibility of ultra-sensitive 14C measurements for the biomedical research community by training of new investigators and expanding our national user base. 3. Provide high throughput, ultra-sensitive 14C analysis for the NIGMS and NIH user community.

47 OTHER INSTRUMENTATION↗

Elucidating the Roles of Electric Fields in Catalysis: A Perspective

This Perspective illustrates how the presence of internal and external electric fields can affect catalytic activity and selectivity, with a focus on heterogeneous catalysts. Specifically, experimental investigations of the electric field influence on catalyst selectivity in pulsed field mass desorption microscopes, scanning tunneling microscopes, probe–bed–probe reactors, continuous-circuit reactors, and capacitor reactors are described. Through these examples, we show how the electric field, whether externally applied or intrinsically present, can affect the behavior of a wide number of materials relevant to catalysis. Here, we review some of the theoretical methods that have been used to elucidate the influence of external electric fields on catalytic reactions, as well as the application of such methods to selective methane activation. In doing so, we illustrate the breadth of possibilities in field-assisted catalysis.

03 NATURAL GAS↗

Greedy Sampling and Incremental Surrogate Model-Based Tailoring of Aeroservoelastic Model Database for Flexible Aircraft

This paper presents a data analysis and modeling framework to tailor and develop linear parameter-varying (LPV) aeroservoelastic (ASE) model database for flexible aircrafts in broad 2D flight parameter space. The Kriging surrogate model is constructed using ASE models at a fraction of grid points within the original model database, and then the ASE model at any flight condition can be obtained simply through surrogate model interpolation. The greedy sampling algorithm is developed to select the next sample point that carries the worst relative error between the surrogate model prediction and the benchmark model in the frequency domain among all input-output channels. The process is iterated to incrementally improve surrogate model accuracy till a pre-determined tolerance or iteration budget is met. The methodology is applied to the ASE model database of a flexible aircraft currently being tested at NASA/AFRC for flutter suppression and gust load alleviation. Our studies indicate that the proposed method can reduce the number of models in the original database by 67%. Even so the ASE models obtained through Kriging interpolation match the model in the original database constructed directly from the physics-based tool with the worst relative error far below 1%. The interpolated ASE model exhibits continuously-varying gains along a set of prescribed flight conditions. More importantly, the selected grid points are distributed non-uniformly in the parameter space, a) capturing the distinctly different dynamic behavior and its dependence on flight parameters, and b) reiterating the need and utility for adaptive space sampling techniques for ASE model database compaction. The present framework is directly extendible to high-dimensional flight parameter space, and can be used to guide the ASE model development, model order reduction, robust control synthesis and novel vehicle design of flexible aircraft.

numerical analysi↗

How Do You Go From a Concept Idea to a NASA Selected Mission? Formulating the Psyche Discovery Mission with JPL's Concurrent Engineering Teams

JPL’s Office of Formulation provides continuity of support and access to domain subject matter experts, as Principal Investigators mature their mission concepts from “cocktail napkin” ideas to Preliminary Design Reviews [1]. Using NASA’s Psyche mission as a case study, we will describe JPL’s concurrent engineering ATeam and Team X support to the Psyche competed concept study team in the areas of 1) Science Feasibility, 2) Trade Space Exploration, 3) Spacecraft Point Design and Cost Estimate, 4) Science, Technical, Management, and Cost Review, and 5) Strategy and Communication Development. NASA’s Psyche Discovery class mission started as a grassroots idea in our A-Team facility, and in less than five years was selected as a mission under NASA’s Discovery Program. While Psyche had a dedicated concept development team [2], they utilized JPL’s concurrent engineering teams, methods, analysis tools, and experts throughout their mission concept lifecycle.

Ziemer, John↗

Revisiting the Impact of Anion Selection on Sulfur Redox Reaction Kinetics for High Sulfur Loading Lithium–Sulfur Batteries

Lithium bis(trifluoromethane)sulfonimide (LiTFSI) is widely used in lithium–sulfur (Li–S) battery electrolytes due to its stability with lithium polysulfides (LiPSs) and moderate compatibility with lithium metal anodes. However, LiTFSI presents environmental concerns due to its association with per- and polyfluoroalkyl substances (PFAS), which are environmentally persistent and potentially toxic, raises sustainability concerns. This research also reveals that LiTFSI limits sulfur redox reactions (SRRs), making it less effective than other lithium salts. Additionally, some salts previously considered incompatible with Li-S systems due to their reactivity with LiPSs are demonstrated to perform effectively. For the first time, a protective, porous cathode electrolyte interphase (CEI) formed in situ through reactions between salt anions and LiPS is reported. The cells delivered a high specific capacity of 1230.8 mAh g −1 at 0.05 C with a sulfur loading of ≈6 mg cm −2 , limited lithium anode, maintaining a capacity retention of 76.2% after 100 cycles at 0.1 C. Under harsh conditions, such as high sulfur loading, lean electrolyte conditions (3 µL mg −1 ), and in anode-free cells, the cells continued to deliver outstanding capacity. This work provides valuable guidelines for understanding and selecting lithium salts to advance electrolyte design for Li–S batteries.

high loading batteries↗

Crystalline materials for quantum computing: Semiconductor heterostructures and topological insulators exemplars

Abstract High-purity crystalline solid-state materials play an essential role in various technologies for quantum information processing, from qubits based on spins to topological states. New and improved crystalline materials emerge each year and continue to drive new results in experimental quantum science. This article summarizes the opportunities for a selected class of crystalline materials for qubit technologies based on spins and topological states and the challenges associated with their fabrication. We start by describing semiconductor heterostructures for spin qubits in gate-defined quantum dots and benchmark GaAs, Si, and Ge, the three platforms that demonstrated two-qubit logic. We then examine novel topologically nontrivial materials and structures that might be incorporated into superconducting devices to create topological qubits. We review topological insulator thin films and move onto topological crystalline materials, such as PbSnTe, and its integration with Josephson junctions. We discuss advances in novel and specialized fabrication and characterization techniques to enable these. We conclude by identifying the most promising directions where advances in these material systems will enable progress in qubit technology.

Scappucci, G. (ORCID:0000000325120079)↗

Satellite Sea Ice Measurements in the Arctic Ocean

Satellite observations sustained since 1979 have been the primary source of information to reveal Arctic Ocean sea ice extent is diminishing rapidly. Sea ice is also thinning based on historical surface and near-surface records and more recent satellite retrievals. There is a new “normal” environment in the Arctic environment with substantial socio-economic impacts. A key question is: What are the spatial and temporal characteristics of the sea ice thickness distribution throughout the annual cycle, and what is the evolving inter-annual trend? Arctic Ocean sea ice conditions have been determined with passive microwave radiometer, active scatterometer and other satellite instrument measurements recorded by a continuing series of satellites. An important feature of the continuous time series measurements has been the overlap of each new satellite dataset with ongoing measurements so as to provide adequate time intervals for calibration and validation. Satellite instrument diversity has provided both coarse spatial resolution measurements over the entire Arctic Ocean for long-period time series and limited-duration fine spatial resolution data over selected regions for navigation and other applications. Satellite observations of Arctic Ocean sea ice will continue to increase in importance because predictability of sea ice is poor and societal interest is great. Unfortunately, however the sustainability of some critical elements of the current Arctic Ocean satellite measurement suite beyond 2020 remains uncertain, e.g., after the CryoSat-2 and ICESat-2 missions have concluded.

Halpern, David↗

COMPARATIVE ANALYSIS OF SELECTED EDDY CURRENT TRANSDUCERS FOR TITANIUM ALLOY EVALUATION

Titanium alloy based details due to their mechanical properties continue to be in extensive use in various structures (mainly aerospace, automotive and petro-chemical industrial applications). In this paper comparative study of various types of eddy current NDT transducers for testing titanium elements was done. Probes of absolute, differential and array configurations were constructed and analyzed. Two and three dimensional numerical analysis (FEM) were done in order to find the best type and configuration of the proposed transducers.

36 MATERIALS SCIENCE↗