Search NASA⌕ Search

SEARCH · Search NASA

Results for “control algorithm”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The Fault Detection, Localization, and Tolerant Operation of Modular Multilevel Converters with an Insulated Gate Bipolar Transistor (IGBT) Open Circuit Fault

Reliability is one of the critical issues for a modular multilevel converter (MMC) since it consists of a large number of series-connected power electronics submodules (SMs). Here in this paper, a complete control strategy including fault detection, localization, and tolerant operation is proposed for the MMC under an insulated gate bipolar transistor (IGBT) open circuit fault. According to the output characteristics of the SM with the open-circuit fault of IGBT, a fault detection method based on the circulating current and output current observation is used. In order to further precisely locate the position of the faulty SM, a fault localization method based on the SM capacitor voltage observation is developed. After the faulty SM is isolated, the continuous operation of the converter is ensured by adopting the fault-tolerant strategy based on the use of redundant modules. To verify the proposed fault detection, fault localization, and fault-tolerant operation strategies, a 900 kVA MMC system under the conditions of an IGBT open circuit is developed in the Matlab/Simulink platform. The capabilities of rapid detection, precise positioning, and fault-tolerant operation of the investigated detection and control algorithms are also demonstrated.

42 ENGINEERING↗

Quantifying the Opportunity Limits of Automatic Residential Electric Load Shaping

Electric utility residential demand response programs typically reduce load a few times a year during periods of peak energy use. In the future, utilities and consumers may monetarily and environmentally benefit from continuously shaping load by alternatively encouraging or discouraging the use of electricity. One way to shape load and introduce elasticity is to broadcast forecasts of dynamic electricity prices that orchestrate electricity supply and demand in order to maximize the efficiency of conventional generation and the use of renewable resources including wind and solar energy. A binary control algorithm that influences the on and off states of end uses was developed and applied to empirical time series data to estimate price-based instantaneous opportunities for shedding and adding electric load. To overcome the limitations of traditional stochastic methods in quantifying diverse, non-Gaussian, non-stationary distributions of observed appliance behaviour, recent developments in wavelet-based analysis were applied to capture and simulate time-frequency domain behaviour. The performance of autoregressive and spectral reconstruction methods was compared, with phase reconstruction providing the best simulation ensembles. Results show spatiotemporal differences in the amount of load that can be shed and added, which suggest further investigation is warranted in estimating the benefits anticipated from the wide-scale deployment of continuous automatic residential load shaping. Empirical data and documented software code are included to assist in reproducing and extending this work.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigations into Balancing Peak-to-Average Power Ratio and Mean Power Extraction for a Two-Body Point-Absorber Wave Energy Converter

The power harnessed by wave energy converters (WECs) in oceans is highly variable and, therefore, has a high peak-to-average power (PTAP) ratio. To minimize the cost of a WEC power take off (PTO) system, it is desirable to reduce the PTAP ratio while maximizing the mean power extracted by WECs. The important issue of how PTAP ratio reduction measures (such as adding an inertia element) can affect the mean power extracted in a reference model has not been thoroughly addressed in the literature. To investigate this correlation, this study focuses on the integration of the U.S. Department of Energy’s Reference Model 3, a two-body point absorber, with a slider-crank WEC for linear-to-rotational conversion. In the first phase of this study, a full-scale numerical model was developed that predicts how PTO system parameters, along with an advanced control algorithm, can potentially affect the proposed WEC’s PTAP ratio as well as the mean power extracted. In the second phase, an appropriate scaled-down model was developed, and extracted power results were successfully validated against the full-scale model. Finally, numerical and hardware-in-the-loop (HIL) simulations based on the scaled-down model were designed and conducted to optimize or make trade-offs between the operational performance and PTAP ratio. The initial results with numerical and HIL simulations reveal that gear ratio, crank radius, and generator parameters substantially impact the PTAP ratio and mean power extracted.

16 TIDAL AND WAVE POWER↗

Heavy Duty Natural Gas Single Cylinder Research Engine Installation, Commissioning, and Baseline Testing

Natural Gas (NG) Internal Combustion Engines (ICE) are a promising alternative to diesel engines for on-road heavy-duty applications to reduce greenhouse gas and harmful pollutant emissions. NG engines have not been widely adopted due to the lower thermal efficiency compared with diesel engine counterparts. To develop the base knowledge required to reach the desired efficiency, a Single Cylinder Engine (SCE) is the most effective platform to acquire reliable and repeatable data. A SCE test cell was developed using a Cummins 15-liter six-cylinder heavy-duty engine block modified to fire one cylinder (2.5-liter displacement). A Woodward Large Engine Control Module (LECM) is integrated to permit implementation of real-time advanced combustion control. Intake and exhaust characteristics, fuel composition, and exhaust gas recirculated substitution rate (EGR) are fully adjustable. A high-speed data acquisition system acquires in-cylinder, intake, and exhaust pressure for combustion analysis. The baseline testing shows reliable and consistent results for engine thermal efficiency, indicated mean effective pressure (IMEP), and coefficient of variance of the IMEP over a wide range of operating conditions while achieving effective control of all engine control and operation variables. This test cell will be used to conduct a research program to develop new and innovative control algorithms and CFD optimized combustion chamber designs, allowing ultra-high efficiency and low emissions for NG ICE heavy-duty on-road applications.

03 NATURAL GAS↗

Model Validation of the Honda Accord Plug-In

This paper presents the validation of an entire vehicle model of the Honda Accord Plug-in Hybrid Electric Vehicle (PHEV), which has a new powertrain system that can be driven in both series and parallel hybrid drive using a clutch, including thermal aspects. The Accord PHEV is a series-parallel PHEV with about 21 km of all-electric range and no multi-speed gearbox. Vehicle testing was performed at Argonne’s Advanced Powertrain Research Facility on a chassis dynamometer set in a thermal chamber. First, components (engine, battery, motors and wheels) were modeled using the test data and publicly available assumptions. This includes calibration of the thermal aspects, such as engine efficiency as a function of coolant temperature. In the second phase, the vehicle-level control strategy, especially the energy management, was analyzed in normal conditions in both charge-depleting and charge-sustaining modes. The third part examined how different thermal conditions such as environmental conditions (–7°C or 35°C with solar load) or vehicle state (soaked or warmed-up vehicle) affect the control strategy. Finally, the validation of the model implemented in Autonomie, a high-fidelity, forward-looking vehicle simulation tool, is presented. The fuel consumption figures are within the test-to-test variability, while many of the operation and control signals are also matched. Now that it has been validated, this model can be used for a wide range of simulations studies that include temperature as a parameter for the comparison and optimization of components, vehicle powertrain system, or control algorithm.

Jeong, Jongryeol↗

Artificial Neural Networks for In-Cycle Prediction of Knock Events

Downsized turbocharged engines have been increasingly popular in modern light-duty vehicles due to their fuel efficiency benefits. However, high power density in such engines is achieved thanks to high in-cylinder pressure and temperature conditions that increase knock propensity. Next-cycle control has been studied as a method to reduce the damaging effects of knock by operating the engine in a low knock probability condition. This exploratory study looks at the feasibility of in-cycle knock prediction as a tool for advanced knock control algorithms. A methodology is proposed to 1) choose in-cycle features of the pressure trace that highly correlate with knock events and 2) train artificial neural networks to predict in-cycle knock events before knock onset. The methodology was validated at different operating conditions and different levels of generalization. Precision and recall were used as metrics to evaluate the binary classifier. However, the Fowlkes-Mallows (FM) index was used to compare the result of the clustering algorithm at different operating conditions. The results showed a maximum FM index of 0.7 when the prediction was done at knock onset and a minimum FM index of 0.45 when the prediction was done at spark timing.

42 ENGINEERING↗

Antarctic ice sheet model comparison with uncurated geological constraints shows that higher spatial resolution improves deglacial reconstructions

Accurately reconstructing past changes to the shape and volume of the Antarctic ice sheet relies on the use of physically based and thus internally consistent ice sheet modeling, benchmarked against spatially limited geologic data. The challenge in model benchmarking against geologic data is diagnosing whether model-data misfits are the result of an inadequate model, inherently noisy or biased geologic data, and/or incorrect association between modeled quantities and geologic observations. In this work we address this challenge by (i) the development and use of a new model-data evaluation framework applied to an uncurated data set of geologic constraints, and (ii) nested high-spatial-resolution modeling designed to test the hypothesis that model resolution is an important limitation in matching geologic data. While previous approaches to model benchmarking employed highly curated datasets, our approach applies an automated screening and quality control algorithm to an uncurated public dataset of geochronological observations (specifically, cosmogenic-nuclide exposure-age measurements from glacial deposits in ice-free areas). This optimizes data utilization by including more geological constraints, reduces potential interpretive bias, and allows unsupervised assimilation of new data as they are collected. We also incorporate a nested model framework in which high-resolution domains are downscaled from a continent-wide ice sheet model. We highlight the application of this framework by applying these methods to a small ensemble of deglacial ice-sheet model simulations, and demonstrate that the nested approach improves the ability of model simulations to match exposure age data collected from areas of complex topography and ice flow. We develop a range of diagnostic model-data comparison metrics to provide more insight into model performance than possible from a single-valued misfit statistic, showing that different metrics capture different aspects of ice sheet deflation.

Geosciences↗

Hydrodynamic Modelling for Tidal Energy Kites: Cooperative Research and Development Final Report, CRADA Number CRD-24-30123

The primary goal of the work is to improve accuracy of hydrodynamic loads acting on the lifting surface of the kite turbine due to complex air-water-lifting body interaction in a low-order numerical model using high-fidelity numerical input. The result of this study will help the Participant better design control algorithms for the kite turbine so that the turbine can harvest more energy while maintaining stability of the platform as well as its reliability. The use of hydrodynamic coefficients/load components from computational fluid dynamic simulation will inform better inputs for a medium-fidelity dynamic model (specifically an OrcaFlex model) which is intended for use in rapid design iterations in the design process.

16 TIDAL AND WAVE POWER↗

Robust broadcast-communication control of electric vehicle charging

The anticipated increase in the number of plug-in electric vehicles (EV) will put additional strain on electrical distribution circuits. Many control schemes have been proposed to control EV charging. Here, we develop control algorithms based on randomized EV charging start times and simple one-way broadcast communication allowing for a time delay between communication events. Using arguments from queuing theory and statistical analysis, we seek to maximize the utilization of excess distribution circuit capacity while keeping the probability of a circuit overload negligible.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of a FAST-OrcaFlex Coupling Module for Integrating Turbine and Mooring Dynamics of Offshore Floating Wind Turbines: Preprint

To enable offshore floating wind turbine design, the following are required: accurate modeling of the wind turbine structural dynamics, aerodynamics, platform hydrodynamics, a mooring system, and control algorithms. Mooring and anchor design can appreciably affect the dynamic response of offshore wind platforms that are subject to environmental loads. From an engineering perspective, systembehavior and line loads must be studied well to ensure the overall design is fit for the intended purpose. FAST (Fatigue, Aerodynamics, Structures and Turbulence) is a comprehensive simulation tool used for modeling land-based and offshore wind turbines. In the case of a floating turbine, continuous cable theory is used to emulate mooring line dynamics. Higher modeling fidelity can be gainedthrough the use of finite element mooring theory. This can be achieved through the FASTlink coupling module, which couples FAST with OrcaFlex, a commercial simulation tool used for modeling mooring line dynamics. In this application, FAST is responsible for capturing the aerodynamic loads and flexure of the wind turbine and its tower, and OrcaFlex models the mooring line and hydrodynamic effectsbelow the water surface. This paper investigates the accuracy and stability of the FAST/OrcaFlex coupling operation.

17 WIND ENERGY↗

Optimal Sizing of Energy Storage and Photovoltaic Power Systems for Demand Charge Mitigation (Poster)

Commercial facility utility bills are often a strong function of demand charges -- a fee proportional to peak power demand rather than total energy consumed. In some instances, demand charges can constitute more than 50% of a commercial customer's monthly electricity cost. While installation of behind-the-meter solar power generation decreases energy costs, its variability makes it likely to leave the peak load -- and thereby demand charges -- unaffected. This then makes demand charges an even larger fraction of remaining electricity costs. Adding controllable behind-the-meter energy storage can more predictably affect building peak demand, thus reducing electricity costs. Due to the high cost of energy storage technology, the size and operation of an energy storage system providing demand charge management (DCM) service must be optimized to yield a positive return on investment (ROI). The peak demand reduction achievable with an energy storage system depends heavily on a facility's load profile, so the optimal configuration will be specific to both the customer and the amount of installed solar power capacity. We explore the sensitivity of DCM value to the power and energy levels of installed solar power and energy storage systems. An optimal peak load reduction control algorithm for energy storage systems will be introduced and applied to historic solar power data and meter load data from multiple facilities for a broad range of energy storage system configurations. For each scenario, the peak load reduction and electricity cost savings will be computed. From this, we will identify a favorable energy storage system configuration that maximizes ROI.

14 SOLAR ENERGY↗

VALIDATION AND RESULTS OF A PSEUDO-MULTI-ZONE COMBUSTION TRAJECTORY PREDICTION MODEL FOR CAPTURING SOOT AND NOX FORMATION ON A MEDIUM DUTY DIESEL ENGINE

A pseudo-multi-zone phenomenological model has been created with the ultimate goal of supporting efforts to enable broader commercialization of low temperature combustion modes in diesel engines. The benefits of low temperature combustion are the simultaneous reduction in soot and nitric oxide emissions and increased engine efficiency if combustion is properly controlled. Determining what qualifies as low temperature combustion for any given engine can be difficult without expensive emissions analysis equipment. This determination can be made off-line using computer models or through factory calibration procedures. This process could potentially be simplified if a real-time prediction model could be implemented to run for any engine platform this is the motivation for this study. The major benefit of this model is the ability for it to predict the combustion trajectory, i.e. local temperature and equivalence ratio in the burning zones. The model successfully captures all the expected trends based on the experimental data and even highlights an opportunity for simply using the average reaction temperature and equivalence ratio as an indicator of emissions levels alone - without solving formation sub-models. This general type of modeling effort is not new, but a major effort was made to minimize the calculation duration to enable implementation as an input to real-time next-cycle engine controller Instead of simply using the predicted engine out soot and NOx levels, control decisions could be made based on the trajectory. This has the potential to save large amounts of calibration time because with minor tuning (the model has only one automatically determined constant) it is hoped that the control algorithm would be generally applicable.

Bittle, Joshua A.↗

Models of TCP in high-BDP environments and their experimental validation

In recent years, the computer networking community has seen a steady growth in bandwidth-delay products (BDPs). Several TCP variants were created to combat the shortcomings of legacy TCP when it comes to operation in high-BDP environments. These variants, among which are CUBIC, STCP, and H-TCP, have been extensively studied in some empirical contexts, and some analytical models exist for CUBIC and STCP. However, since these studies have been conducted, BDPs have risen even more, and new bulk data transfer tools have emerged that utilize multiple parallel TCP streams. In view of these new developments, it is imperative to revisit the question: Which congestion control algorithms are best adapted to current networking environments? In order to help resolve this question, we contribute the following: (i) using first principles, we develop a general throughput-prediction framework that takes into account buffer sizes and maximum window constraints; (ii) we validate the models using measurements and achieve low prediction errors; (iii) we note differences in TCP dynamics between two experimental configurations and find one of them to be significantly more deterministic than the other; we also find that CUBIC and H-TCP outperform STCP, especially when multiple streams are used; and (iv) we present preliminary results for modelling multiple TCP streams for CUBIC and STCP.

Vardoyan, G.↗

Dynamic Modeling and Grid Interaction of a Tidal and River Generator

This presentation provides a high-level overview of the deployment of a river generator installed in a small system. The turbine dynamics of a river generator, electrical generator, and power converter are modeled in detail. Various simulations can be exercised, and the impact of different control algorithms, failures of power switches, and corresponding impacts can be examined.

13 HYDRO ENERGY↗

Connected and Automated Vehicle Merging at Highway On-Ramps

Recognition of the necessity for connected and automated vehicles (CAVs) is gaining momentum. CAVs can improve both transportation network efficiency and safety through control algorithms that can harmonically use all existing information to coordinate the vehicles. This study addresses the problem of optimally coordinating CAVs at merging roadways to achieve a smooth traffic flow without stop-and-go driving. We present an optimization framework and an analytical, closed-form solution that allows online coordination of vehicles at the merging zone. The effectiveness of the efficiency of the proposed solution is validated through simulation and it is shown that coordination of vehicles can reduce fuel consumption and travel time significantly.

Malikopoulos, Andreas↗

Numerical Model Development and Validation for the WECCOMP Control Competition: Preprint

This paper details the development and validation of a numerical model of the Wavestar wave energy converter (WEC) in WEC-Sim. This numerical model was developed in support of the WEC Control Competition (WECCCOMP), an open competition with the objective of maximizing WEC power production through innovative control strategies. WECCCOMP has two stages: numerical implementation of control strategies, and experimental implementation. The work presented in this paper is for support of the stage one numerical implementation, where contestants are provided a WEC-Sim model of the Wavestar device to develop their control algorithms.

16 TIDAL AND WAVE POWER↗

Model predictive control and optimization for battery charging and discharging

An apparatus for model predictive control (“MPC”) is disclosed. A method and system also perform the functions of the apparatus. The apparatus includes a measurement module that receives battery status information from one or more sensors receiving information from a battery cell, and a Kalman filter module that uses a Kalman filter and the battery status information to provide a state estimate vector. The apparatus includes a battery model module that inputs the state estimate vector and battery status information into a battery model and calculates a battery model output, the battery model representing the battery cell, and an MPC optimization module that inputs one or more battery model outputs and an error signal in a model predictive control algorithm to calculate an optimal response. The optimal response includes a modification of the error signal.

Trimboli, Michael Scott↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗