Search NASA⌕ Search

SEARCH · Search NASA

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

ADVANCED OXIDATION: OXALATE DECOMPOSITION TESTING WITH OZONE

At the Savannah River Site (SRS), oxalic acid is currently considered the preferred agent for chemically cleaning the large underground Liquid Radioactive Waste Tanks. It is applied only in the final stages of emptying a tank when generally less than 5,000 kg of waste solids remain, and slurrying based removal methods are no-longer effective. The use of oxalic acid is preferred because of its combined dissolution and chelating properties, as well as the fact that corrosion to the carbon steel tank walls can be controlled. Although oxalic acid is the preferred agent, there are significant potential downstream impacts. Impacts include: (1) Degraded evaporator operation; (2) Resultant oxalate precipitates taking away critically needed operating volume; and (3) Eventual creation of significant volumes of additional feed to salt processing. As an alternative to dealing with the downstream impacts, oxalate decomposition using variations of ozone based Advanced Oxidation Process (AOP) were investigated. In general AOPs use ozone or peroxide and a catalyst to create hydroxyl radicals. Hydroxyl radicals have among the highest oxidation potentials, and are commonly used to decompose organics. Although oxalate is considered among the most difficult organic to decompose, the ability of hydroxyl radicals to decompose oxalate is considered to be well demonstrated. In addition, as AOPs are considered to be 'green' their use enables any net chemical additions to the waste to be minimized. In order to test the ability to decompose the oxalate and determine the decomposition rates, a test rig was designed, where 10 vol% ozone would be educted into a spent oxalic acid decomposition loop, with the loop maintained at 70 C and recirculated at 40L/min. Each of the spent oxalic acid streams would be created from three oxalic acid strikes of an F-area simulant (i.e., Purex = high Fe/Al concentration) and H-area simulant (i.e., H area modified Purex = high Al/Fe concentration) after nearing dissolution equilibrium, and then decomposed to {le} 100 Parts per Million (ppm) oxalate. Since AOP technology largely originated on using ultraviolet (UV) light as a primary catalyst, decomposition of the spent oxalic acid, well exposed to a medium pressure mercury vapor light was considered the benchmark. However, with multi-valent metals already contained in the feed, and maintenance of the UV light a concern; testing was conducted to evaluate the impact from removing the UV light. Using current AOP terminology, the test without the UV light would likely be considered an ozone based, dark, ferrioxalate type, decomposition process. Specifically, as part of the testing, the impacts from the following were investigated: (1) Importance of the UV light on the decomposition rates when decomposing 1 wt% spent oxalic acid; (2) Impact of increasing the oxalic acid strength from 1 to 2.5 wt% on the decomposition rates; and (3) For F-area testing, the advantage of increasing the spent oxalic acid flowrate from 40 L/min (liters/minute) to 50 L/min during decomposition of the 2.5 wt% spent oxalic acid. The results showed that removal of the UV light (from 1 wt% testing) slowed the decomposition rates in both the F & H testing. Specifically, for F-Area Strike 1, the time increased from about 6 hours to 8 hours. In H-Area, the impact was not as significant, with the time required for Strike 1 to be decomposed to less than 100 ppm increasing slightly, from 5.4 to 6.4 hours. For the spent 2.5 wt% oxalic acid decomposition tests (all) without the UV light, the F-area decompositions required approx. 10 to 13 hours, while the corresponding required H-Area decompositions times ranged from 10 to 21 hours. For the 2.5 wt% F-Area sludge, the increased availability of iron likely caused the increased decomposition rates compared to the 1 wt% oxalic acid based tests. In addition, for the F-testing, increasing the recirculation flow rates from 40 liter/minute to 50 liter/minute resulted in an increased decomposition rate, suggesting a better use of ozone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High surface area carbon and process for its production

Activated carbon materials and methods of producing and using activated carbon materials are provided. In particular, biomass-derived activated carbon materials and processes of producing the activated carbon materials with prespecified surface areas and pore size distributions are provided. Activated carbon materials with preselected high specific surface areas, porosities, sub-nm (<1 nm) pore volumes, and supra-nm (1-5 nm) pore volumes may be achieved by controlling the degree of carbon consumption and metallic potassium intercalation into the carbon lattice during the activation process.

36 MATERIALS SCIENCE↗

On the validity of density overrides for VMAT lung SBRT planning

Purpose: Modeling dose to a moving target in lung is a very difficult task. Current approaches to planning lung stereotactic body radiotherapy (SBRT) generally calculate dose on either free breathing or average computed tomography (CT) scans, which do not always accurately predict dose to parts of the target volume not occupied by tumor on the planning scan. In this work, the authors look at using density overrides of the target volumes to more accurately predict dose for lung SBRT using the analytic anisotropic algorithm (AAA). Methods: Volumetric modulated arc therapy plans were created on free breathing scans (FBP), time average scans (AVGP), free breathing scans with the internal target volume overridden to tumor density (ITVP), free breathing scans with the planning target volume overridden to tumor density (PTVP), and free breathing scan using a hybrid scheme with the internal target volume set to tumor density and the planning target volume minus the internal target volume set to a density intermediate between lung and tumor (HP) for the case of a 4D motion phantom and five patient cases. Radiochromic film measurements were made for the phantom plans, with gamma analysis used to compare the planned to delivered dose. The patient plans were recalculated on each of the phases of a 4DCT to evaluate tumor coverage and conformity index (CI). A modified modulation complexity score (MCSv) and average open area per control point (AA) metrics were used to evaluate multileaf collimator (MLC) modulation for each of the plans. Results: The HP plans showed significantly higher gamma passing rates (p < 0.05) than the FBP, AVGP, and ITVP for criteria of 2 mm/2% and 1 mm/1%. No significant correlation was observed between gamma values and AA or MCSv. The tumor volume was covered by the prescription dose on all phases of the 4DCT for all patient plans. The PTVP and HP yielded lower mean CI than the other plans for all five patients, with three of the cases showing statistically significant differences (p < 0.05). No meaningful correlation was observed between the mean CI and AA or MCSv. Conclusions: These measurements suggest that the HP planning method may provide more accurate dose modeling and decreased normal lung irradiation for lung SBRT compared to the commonly used FBP and AVG planning methods when used with the AAA. The HP method does not appear to have a strong relationship with MLC modulation.

60 APPLIED LIFE SCIENCES↗

High-fidelity retrieval from instantaneous line-of-sight returns of nacelle-mounted lidar including supervised machine learning

Abstract. Wind turbine applications that leverage nacelle-mounted Doppler lidar are hampered by several sources of uncertainty in the lidar measurement, affecting both bias and random errors. Two problems encountered especially for nacelle-mounted lidar are solid interference due to intersection of the line of sight with solid objects behind, within, or in front of the measurement volume and spectral noise due primarily to limited photon capture. These two uncertainties, especially that due to solid interference, can be reduced with high-fidelity retrieval techniques (i.e., including both quality assurance/quality control and subsequent parameter estimation). Our work compares three such techniques, including conventional thresholding, advanced filtering, and a novel application of supervised machine learning with ensemble neural networks, based on their ability to reduce uncertainty introduced by the two observed nonideal spectral features while keeping data availability high. The approach leverages data from a field experiment involving a continuous-wave (CW) SpinnerLidar from the Technical University of Denmark (DTU) that provided scans of a wide range of flows both unwaked and waked by a field turbine. Independent measurements from an adjacent meteorological tower within the sampling volume permit experimental validation of the instantaneous velocity uncertainty remaining after retrieval that stems from solid interference and strong spectral noise, which is a validation that has not been performed previously. All three methods perform similarly for non-interfered returns, but the advanced filtering and machine learning techniques perform better when solid interference is present, which allows them to produce overall standard deviations of error between 0.2 and 0.3 m s−1, or a 1 %–22 % improvement versus the conventional thresholding technique, over the rotor height for the unwaked cases. Between the two improved techniques, the advanced filtering produces 3.5 % higher overall data availability, while the machine learning offers a faster runtime (i.e., ∼ 1 s to evaluate) that is therefore more commensurate with the requirements of real-time turbine control. The retrieval techniques are described in terms of application to CW lidar, though they are also relevant to pulsed lidar. Previous work by the authors (Brown and Herges, 2020) explored a novel attempt to quantify uncertainty in the output of a high-fidelity lidar retrieval technique using simulated lidar returns; this article provides true uncertainty quantification versus independent measurement and does so for three techniques rather than one.

47 OTHER INSTRUMENTATION↗

Proton Beam Therapy for Large Hepatocellular Carcinoma

Purpose: To investigate the safety and efficacy of proton beam therapy (PBT) in patients with large hepatocellular carcinoma (HCC). Methods and Materials: Twenty-two patients with HCC larger than 10 cm were treated with proton beam therapy at our institution between 1985 and 2006. Twenty-one of the 22 patients were not surgical candidates because of advanced HCC, intercurrent disease, or old age. Median tumor size was 11 cm (range, 10-14cm), and median clinical target volume was 567 cm{sup 3} (range, 335-1,398 cm{sup 3}). Hepatocellular carcinoma was solitary in 18 patients and multifocal in 4 patients. Tumor types were nodular and diffuse in 18 and 4 patients, respectively. Portal vein tumor thrombosis was present in 11 patients. Median total dose delivered was 72.6 GyE in 22 fractions (range, 47.3-89.1 GyE in 10-35 fractions). Results: The median follow-up period was 13.4 months (range, 1.5-85 months). Tumor control rate at 2 years was 87%. One-year overall and progression-free survival rates were 64% and 62%, respectively. Two-year overall and progression-free survival rates were 36% and 24%, respectively. The predominant tumor progression pattern was new hepatic tumor development outside the irradiated field. No late treatment-related toxicity of Grade 3 or higher was observed. Conclusions: The Bragg peak properties of PBT allow for improved conformality of the treatment field. As such, large tumor volumes can be irradiated to high doses without significant dose exposure to surrounding normal tissue. Proton beam therapy therefore represents a promising modality for the treatment of large-volume HCC. Our study shows that PBT is an effective and safe method for the treatment of patients with large HCC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Protection During Percutaneous Thermal Ablation Procedures: Interest of Carbon Dioxide Dissection and Temperature Monitoring

Percutaneous image-guided thermal ablation of tumor is widely used, and thermal injury to collateral structures is a known complication of this technique. To avoid thermal damage to surrounding structures, several protection techniques have been reported. We report the use of a simple and effective protective technique combining carbon dioxide dissection and thermocouple: CO{sub 2} displaces the nontarget structures, and its low thermal conductivity provides excellent insulation; insertion of a thermocouple in contact with vulnerable structures achieves continuous thermal monitoring. We performed percutaneous thermal ablation of 37 tumors in 35 patients (4 laser, 10 radiofrequency, and 23 cryoablations) with protection of adjacent vulnerable structures by using CO{sub 2} dissection combined with continuous thermal monitoring with thermocouple. Tumor locations were various (19 intra-abdominal tumors including 4 livers and 9 kidneys, 18 musculoskeletal tumors including 11 spinal tumors). CO{sub 2} volume ranged from 10 ml (epidural space) to 1500 ml (abdominal). Repeated insufflations were performed if necessary, depending on the information given by the thermocouple and imaging control. Dissection with optimal thermal protection was achieved in all cases except two patients where adherences (one postoperative, one arachnoiditis) blocked proper gaseous distribution. No complication referred to this technique was noted. This safe, cost-effective, and simple method increases the safety and the success rate of percutaneous thermal ablation procedures. It also offers the potential to increase the number of tumors that can be treated via a percutaneous approach.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a selective, zero power sensor for distributed sensing of hydrogen in energy applications

The use of hydrogen as a clean and renewable energy source is increasing rapidly for both vehicle and stationary applications. There are safety concerns for the locations in which hydrogen is made, used, and transported (i.e., pipelines and tanker trucks). Sensors are needed to comply with safety regulations and to enable a smooth and safe rollout of hydrogen as an alternative energy. However, hydrogen sensors do not yet exist that have the combined features of small size and low power for easy deployment coupled with high-volume manufacturability and low cost. This is necessary to accommodate the emerging fixed and mobile markets while retaining critical metrological metrics, including measurement range, detection limits, selectivity, fast response, stability, and long lifetime. An amperometric gas sensor for hydrogen (AGS) has been developed using an innovative manufacturing method. The sensor was designed using scalable fabrication strategies based on “Printed Electronics” (PE) methodology which are compatible with large-scale production. Prototype sensors were batch fabricated with multiple individual elements on a substrate compatible in size with a standard 8-inch wafer to enable high-volume, low-cost manufacturing, thereby leveraging PE and semiconductor fabrication infrastructure. This novel AGS was instrumented with control circuitry and evaluated for hydrogen detection in the range of 0–5000 ppmv H2 in air. Specific performance evaluations included assessment of the sensor measurement range, repeatability, and selectivity.

08 HYDROGEN↗

Use of the Concept of Equivalent Biologically Effective Dose (BED) to Quantify the Contribution of Hyperthermia to Local Tumor Control in Radiohyperthermia Cervical Cancer Trials, and Comparison With Radiochemotherapy Results

Purpose: To express the magnitude of contribution of hyperthermia to local tumor control in radiohyperthermia (RT/HT) cervical cancer trials, in terms of the radiation-equivalent biologically effective dose (BED) and to explore the potential of the combined modalities in the treatment of this neoplasm. Materials and Methods: Local control rates of both arms of each study (RT vs. RT+HT) reported from randomized controlled trials (RCT) on concurrent RT/HT for cervical cancer were reviewed. By comparing the two tumor control probabilities (TCPs) from each study, we calculated the HT-related log cell-kill and then expressed it in terms of the number of 2 Gy fraction equivalents, for a range of tumor volumes and radiosensitivities. We have compared the contribution of each modality and made some exploratory calculations on the TCPs that might be expected from a combined trimodality treatment (RT+CT+HT). Results: The HT-equivalent number of 2-Gy fractions ranges from 0.6 to 4.8 depending on radiosensitivity. Opportunities for clinically detectable improvement by the addition of HT are only available in tumors with an alpha value in the approximate range of 0.22-0.28 Gy{sup -1}. A combined treatment (RT+CT+HT) is not expected to improve prognosis in radioresistant tumors. Conclusion: The most significant improvements in TCP, which may result from the combination of RT/CT/HT for locally advanced cervical carcinomas, are likely to be limited only to those patients with tumors of relatively low-intermediate radiosensitivity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multidose Stereotactic Radiosurgery (9 Gy × 3) of the Postoperative Resection Cavity for Treatment of Large Brain Metastases

Purpose: To evaluate the clinical outcomes with linear accelerator-based multidose stereotactic radiosurgery (SRS) to large postoperative resection cavities in patients with large brain metastases. Methods and Materials: Between March 2005 to May 2012, 101 patients with a single brain metastasis were treated with surgery and multidose SRS (9 Gy × 3) for large resection cavities (>3 cm). The target volume was the resection cavity with the inclusion of a 2-mm margin. The median cavity volume was 17.5 cm{sup 3} (range, 12.6-35.7 cm{sup 3}). The primary endpoint was local control. Secondary endpoints were survival and distant failure rates, cause of death, performance measurements, and toxicity of treatment. Results: With a median follow-up of 16 months (range, 6-44 months), the 1-year and 2-year actuarial survival rates were 69% and 34%, respectively. The 1-year and 2-year local control rates were 93% and 84%, with respective incidences of new distant brain metastases of 50% and 66%. Local control was similar for radiosensitive (non-small cell lung cancer and breast cancer) and radioresistant (melanoma and renal cell cancer) brain metastases. On multivariate Cox analysis stable extracranial disease, breast cancer histology, and Karnofsky performance status >70 were associated with significant survival benefit. Brain radionecrosis occurred in 9 patients (9%), being symptomatic in 5 patients (5%). Conclusions: Adjuvant multidose SRS to resection cavity represents an effective treatment option that achieves excellent local control and defers the use of whole-brain radiation therapy in selected patients with large brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting the 5-Year Risk of Biochemical Relapse After Postprostatectomy Radiation Therapy in ≥PT2, pN0 Patients With a Comprehensive Tumor Control Probability Model

Purpose: To fit the individual biochemical recurrence-free survival (bRFS) data from patients treated with postprostatectomy radiation therapy (RT) with a comprehensive tumor control probability (TCP) model. Methods and Materials: Considering pre-RT prostate-specific antigen (PSA) as a surrogate of the number of clonogens, bRFS may be expressed as a function of dose-per-fraction–dependent radiosensitivity (α{sub eff}), the number of clonogens for pre-RT PSA = 1 ng/mL (C), and the fraction of patients who relapse because of clonogens outside the treated volume (K), assumed to depend (linearly or exponentially) on pre-RT PSA and Gleason score (GS). Data from 894 node-negative, ≥pT2, pN0 hormone-naive patients treated with adjuvant (n=331) or salvage (n=563) intent were available: 5-year bRFS data were fitted grouping patients according to GS (<7:392, =7:383, >7:119). Results: The median follow-up time, pre-RT PSA, and dose were 72 months, 0.25 ng/mL, and 66.6 Gy (range 59.4-77.4 Gy), respectively. The best-fit values were 0.23 to 0.26 Gy{sup −1} and 10{sup 7} for α{sub eff} and C for the model considering a linear dependence between K and PSA. Calibration plots showed good agreement between expected and observed incidences (slope: 0.90-0.93) and moderately high discriminative power (area under the curve [AUC]: 0.68-0.69). Cross-validation showed satisfactory results (average AUCs in the training/validation groups: 0.66-0.70). The resulting dose-effect curves strongly depend on pre-RT PSA and GS. bRFS rapidly decreases with PSA: the maximum obtainable bRFS (defined as 95% of the maximum) declined by about 2.7% and 4.5% for each increment of 0.1 ng/mL for GS <7 and ≥7, respectively. Conclusions: Individual data were fitted by a TCP model, and the resulting best-fit parameters were radiobiologically consistent. The model suggests that relapses frequently result from clonogens outside the irradiated volume, supporting the choice of lymph-node irradiation, systemic therapy, or both for specific subgroups (GS <7: PSA >0.8-1.0 ng/mL; GS ≥7: PSA >0.3 ng/mL). Early RT should be preferred over delayed RT; the detrimental effect of PSA increase can never be fully compensated by increasing the dose, especially for patients with GS ≥7.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a synchrotron biaxial tensile device for in situ characterization of thin films mechanical response

We have developed on the DIFFABS-SOLEIL beamline a biaxial tensile machine working in the synchrotron environment for in situ diffraction characterization of thin polycrystalline films mechanical response. The machine has been designed to test compliant substrates coated by the studied films under controlled, applied strain field. Technological challenges comprise the sample design including fixation of the substrate ends, the related generation of a uniform strain field in the studied (central) volume, and the operations from the beamline pilot. Preliminary tests on 150 nm thick W films deposited onto polyimide cruciform substrates are presented. The obtained results for applied strains using x-ray diffraction and digital image correlation methods clearly show the full potentialities of this new setup.

36 MATERIALS SCIENCE↗

Performance Improvements of the Griffin Solvers in FY24

The Griffin code is a MOOSE-based reactor physics application jointly developed by Idaho National Laboratory and Argonne National Laboratory under the Department of Energy Office of Nuclear Energy Nuclear Energy Advanced Modeling and Simulation Program. This fiscal year, we have made significant efforts to improve the performance of transport solver options and cross-section generation for the efficient use of Griffin in advanced reactor applications. For the HFEM-PN solver, the residual evaluations of HFEM kernels were optimized by utilizing the pre- computed averaged cross sections for individual elements. Numerical integration involving the evaluation of basis functions at quadrature points was bypassed by facilitating precomputed element mass matrices for response matrices. Red-black iterations were improved by introducing a new generalized minimum residual based solver. The memory usage of response matrix storage was significantly reduced by applying basis function rotations on interfaces and calculating volumetric odd-parity moments on the fly. Additionally, the adjoint flux and transient calculation capabilities of the HFEM-PN solver were successfully implemented and verified using the TWIGL benchmark problem. For the DFEM-SN solver, memory footprint and computation time were significantly reduced by not treating angular flux vectors as the MOOSE nonlinear system vectors. Specifically for IQS, scalar adjoint weighting was introduced to further eliminate angular adjoint flux storage in the MOOSE auxiliary system. It was demonstrated through the three-dimensional Advanced Burner Test Reactor core problem that the memory usage for transient calculations with the IQS method was reduced by over 7.5× compared to before the optimizations. For the self-shielding application programming interface, a new double-heterogeneity treatment method, named the Bell Function-Based Analytic Two-Region Slowing Down Method, was developed to efficiently flux-volume homogenize TRISO particles with the matrix. Additionally, optimizations were made to hyper- fine group (HFG) slowing down calculations by pretabulating collision probability coefficients and grouping isotopes, significantly reducing the computational time for calculating scattering sources per HFG. Lastly, the pin power reconstruction module was extended to account for temporal behavior in a microreactor analysis problem, specifically for a control drum transient. Verification tests for each of these improvements demonstrated significant performance enhancements and memory reduction.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Exposure to polychlorinated biphenyls and the thyroid gland – examining and discussing possible longitudinal health effects in humans

Background: Many previous studies have dealt with the effect of polychlorinated biphenyls (PCBs) on the thyroid gland, but their findings are inconsistent. One problem of these studies has been their use of cross-sectional designs. Objectives: The aim of the current study is to investigate longitudinal effects of PCBs on the thyroid gland, focusing on: morphological changes in thyroid tissue (i.e. thyroid volume), changes in thyroid hormones and in thyroid antibodies. Methods: A total of 122 individuals (M{sub age}=44.7) were examined over a period of four years (t{sup 1} until t{sup 4}). Medical history was collected via interviews, an ultrasound examination was performed and blood samples were taken to determine plasma PCB levels, thyroid stimulating hormone (TSH), free triiodthyronine (fT3), free thyroxine (fT4), thyroid peroxidase antibodies (TPOab), thyreoglobulin antibodies (TGab) and thyroid-stimulating hormone receptor antibodies (TSHRab). Rank correlation coefficients and mixed effect models were performed controlling for age and total lipids. Results: There were negative correlations between higher chlorinated biphenyls and fT3, cross-sectionally as well as longitudinally. We also found an interaction effect of higher-chlorinated PCBs over time for fT4 as well as TSHRab. In case of high exposure, a decrease in fT4 and an increase in TSHRab level were found over time. In regards to the other variables, our findings yielded no clear results in the examined time period. Conclusion: This is the first study to shows a PCB-related effect on fT3, fT4 and TSHRab over a four year period. The data also suggest that morphological and antibody findings remain inconsistent and do not allow for unambiguous interpretation. - Highlights: • This is a longitudinal study which includes data from four cross sections. • Higher-chlorinated biphenyls are negatively correlated with fT3. • There are interactions of time and higher-chlorinated biphenyls to TSHRab and fT4. • There is an interaction of time and dioxin-like polychlorinated biphenyls to fT4. • No consistent effects were found for thyroid volume, TSH, TPOab and TGab.

54 ENVIRONMENTAL SCIENCES↗

In-situ Condition Monitoring of Components in Small Modular Reactors Using Process and Electrical Signature Analysis. Final report, volume 1. Development of experimental flow control loop, data analysis and plant monitoring

The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on plant parameters and the pump electrical signatures. Additionally, the reactor simulation is being used to generate normal operation data and data with instrumentation faults and process anomalies. A frequency controller was interfaced with the motor power supply in order to vary the electrical supply frequency. The experimental flow control loop was used to generate operational data under varying motor performance characteristics. Coolant leakage events were simulated by varying the bypass loop flow rate. The accuracy of motor power calculation was improved by incorporating the power factor, computed from motor current and voltage in each phase of the induction motor.- A variety of experimental runs were made for steady-state and transient pump operating conditions. Process, vibration, and electrical signatures were measured using a submersible pump with variable supply frequency. High correlation was seen between motor current and pump discharge pressure signal; similar high correlation was exhibited between pump motor power and flow rate. Wide-band analysis indicated high coherence (in the frequency domain) between motor current and vibration signals. - Wide-band operational data from a PWR were acquired from AMS Corporation and used to develop time-series models, and to estimate signal spectrum and sensor time constant. All the data were from different pressure transmitters in the system, including primary and secondary loops. These signals were pre-processed using the wavelet transform for filtering both low-frequency and high-frequency bands. This technique of signal pre-processing provides minimum distortion of the data, and results in a more optimal estimation of time constants of plant sensors using time-series modeling techniques.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Integrated Experimental and Modeling Studies of Mineral Carbonation as a Mechanism for Permanent Carbon Sequestration in Mafic/Ultramafic Rocks

A program of laboratory experiments, modeling and fieldwork was carried out at Yale University, University of Maryland, and University of Hawai‘i, under a DOE Award (DE-FE0004375) to study mineral carbonation as a practical method of geologic carbon sequestration. Mineral carbonation, also called carbon mineralization, is the conversion of (fluid) carbon dioxide into (solid) carbonate minerals in rocks, by way of naturally occurring chemical reactions. Mafic and ultramafic rocks, such as volcanic basalt, are natural candidates for carbonation, because the magnesium and iron silicate minerals in these rocks react with brines of dissolved carbon dioxide to form carbonate minerals. By trapping carbon dioxide (CO 2 ) underground as a constituent of solid rock, carbonation of natural basalt formations would be a secure method of sequestering CO 2 captured at power plants in efforts to mitigate climate change. Geochemical laboratory experiments at Yale, carried out in a batch reactor at 200°C and 150 bar (15 MPa), studied carbonation of the olivine mineral forsterite (Mg 2 SiO 4 ) reacting with CO 2 brines in the form of sodium bicarbonate (NaHCO 3 ) solutions. The main carbonation product in these reactions is the carbonate mineral magnesite (MgCO 3 ). A series of 32 runs varied the reaction time, the reactive surface area of olivine grains and powders, the concentration of the reacting fluid, and the starting ratio of fluid to olivine mass. These experiments were the first to study the rate of olivine carbonation under passive conditions approaching equilibrium. The results show that, in a simple batch reaction, olivine carbonation is fastest during the first 24 hours and then slows significantly and even reverses. A natural measure of the extent of carbonation is a quantity called the carbonation fraction, which compares the amount of carbon removed from solution, during a run, to the maximum amount that could have been removed if the olivine initially present had fully dissolved and the cations released had subsequently precipitated in carbonate minerals. The carbonation fractions observed in batch experiments with olivine grains and powders varied significantly, from less than 0.01 (1%) to more than 0.5 (50%). Over time, the carbonation fractions reached an upper limit after about 24 to 72 hours of reaction, then stayed constant or decreased. The peak Final Scientific/Technical Report DE-FE0004275 | Mineral Carbonation | 4 coincided with the appearance of secondary magnesium-bearing silicate minerals, whose formation competes for magnesium ions in solution and can even promote conditions that dissolve magnesite. The highest carbonation fractions resulted from experiments with low ratios of concentrated solution to olivine, during which amorphous silica spheres or meshes formed, instead of secondary silicate minerals. The highest carbonation fractions appear to result from competing effects. Precipitation of silica layers on olivine reduces the reactive surface area and, thus, the rate of olivine dissolution (which ultimately limits the carbonation rate), but these same silica layers can also inhibit the formation of secondary silicate minerals that consume magnesite formed in earlier stages of carbonation. Simulation of these experiments with simple geochemical models using the software program EQ3/6 reproduces the general trends observed—especially the results for the carbonation fraction in short-run experiments. Although further experimentation and better models are needed, this study nevertheless provides a framework for understanding the optimal conditions for sequestering carbon dioxide by reacting CO 2 -bearing fluids with rocks containing olivine minerals. A series of experiments at the Rock Physics Laboratory at the University of Maryland studied the carbonation process during deformation of thermally cracked olivine-rich rock samples (dunite) saturated with CO 2 brines of varying compositions. A goal of these geomechanical experiments was to see if flow and deformation processes, which accompany natural carbonation reactions in underground settings, work to enhance or inhibit the reactions. The experiments involved hydrostatic compaction, followed by deformation at a constant rate of strain. Sample permeability was monitored during the reactions. Comparison of the samples’ volume changes to their axial strains (shortening) during deformation indicates that samples reacted with CO 2 -saturated brines accommodate more axial compaction, before the onset of dilation (a swelling that precedes rock failure), than samples reacted with distilled water. Analyses of the reacted samples with scanning electron microscope (SEM) images indicate, first, that dissolution of olivine occurring in the initial stages of carbonation can provide pathways to fluid flow that sustain the reaction, and, second, that carbonate minerals precipitated along existing fractures in the rocks may serve as asperities, or roughness on a crack’s surface that restricts its closure. Final Scientific/Technical Report DE-FE0004275 | Mineral Carbonation | 5 In a related study undertaken by one of the principal investigators as a spin-off of the main project, a simple model of (magnesite) crystal growth in the pore space of basalts undergoing carbonation was developed. The model suggests that, under a carefully controlled program of CO 2 injection, carbonate mineral growth can harden the rock formation against earthquakes that might otherwise be induced by the injection of large fluid volumes (Yarushina and Bercovici, 2013). The overall conclusion of the research project is that mineral carbonation of underground mafic and ultramafic rock formations is a viable candidate for long-term sequestration of man-made carbon dioxide. No results obtained during the project indicate that the method is inherently intractable in its implementation; moreover, enormous volumes of basalt near Earth’s surface are candidate locations for large-scale injection programs. The geochemical experiments do indicate, however, that there will be significant engineering challenges in maintaining high rates of carbonation, by delaying the onset of chemical conditions that promote formation of secondary silicate minerals and, therefore, slow down, or even reverse, the carbonation process. It remains an open question as to whether carbonation processes can be sustained for many years in an engineered system operating on a large scale—a scale capable of accommodating millions of tons of CO 2 annually. The development of realistic theoretical models that can systematically describe the combined effects of reactive flow, precipitation and geomechanical deformation is a major barrier to further understanding of the practical viability of mineral carbonation as large-scale method of carbon sequestration.

58 GEOSCIENCES↗

Radiosurgery for Large Brain Metastases

Purpose: To determine the efficacy and safety of radiosurgery in patients with large brain metastases treated with radiosurgery. Patients and Methods: Eighty patients with large brain metastases (>14 cm{sup 3}) were treated with radiosurgery between 1998 and 2009. The mean age was 59 {+-} 11 years, and 49 (61.3%) were men. Neurologic symptoms were identified in 77 patients (96.3%), and 30 (37.5%) exhibited a dependent functional status. The primary disease was under control in 36 patients (45.0%), and 44 (55.0%) had a single lesion. The mean tumor volume was 22.4 {+-} 8.8 cm{sup 3}, and the mean marginal dose prescribed was 13.8 {+-} 2.2 Gy. Results: The median survival time from radiosurgery was 7.9 months (95% confidence interval [CI], 5.343-10.46), and the 1-year survival rate was 39.2%. Functional improvement within 1-4 months or the maintenance of the initial independent status was observed in 48 (60.0%) and 20 (25.0%) patients after radiosurgery, respectively. Control of the primary disease, a marginal dose of {>=}11 Gy, and a tumor volume {>=}26 cm{sup 3} were significantly associated with overall survival (hazard ratio, 0.479; p = .018; 95% CI, 0.261-0.880; hazard ratio, 0.350; p = .004; 95% CI, 0.171-0.718; hazard ratio, 2.307; p = .006; 95% CI, 1.274-4.180, respectively). Unacceptable radiation-related toxicities (Radiation Toxicity Oncology Group central nervous system toxicity Grade 3, 4, and 5 in 7, 6, and 2 patients, respectively) developed in 15 patients (18.8%). Conclusion: Radiosurgery seems to have a comparable efficacy with surgery for large brain metastases. However, the rate of radiation-related toxicities after radiosurgery should be considered when deciding on a treatment modality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solvent- and catalyst-free mechanochemical synthesis of alkali metal monohydrides

Alkali metal monohydrides, AH (A = Li–Cs) have been synthesized in quantitative yields at room temperature by reactive milling of alkali metals in the presence of hydrogen gas at 200 bar or less. The mechanochemical approach reported here eliminates problems associated with the malleability of alkali metals — especially Li, Na, and K — and promotes effective solid–gas reactions, ensuring their completion. This is achieved by incorporating a certain volume fraction of the corresponding hydride powder as a process control agent, which allows continuous and efficient milling primarily by coating the surface of metal particles, effectively blocking cold welding. Formation of high-purity crystalline monohydrides has been confirmed by powder X-ray diffraction, solid-state NMR spectroscopy, and volumetric analyses of reactively desorbed H 2 from as-milled samples. The proposed synthesis method is scalable and particularly effective for extremely air-sensitive materials, such as alkali and alkaline earth metal hydrides. Furthermore, the technique may also be favorable for production in continuous reactors operating at room temperature, thereby reducing the total processing time, energy consumption and, hence, the cost of production of these hydrides or their derivatives and composites.

36 MATERIALS SCIENCE↗

SU-F-T-87: Comparison of Advanced Radiotherapy Techniques for Post- Mastectomy Breast Cancer Patients

Purpose: To determine if bolus electron conformal therapy (Bolus-ECT) combined with intensity modulated x-ray therapy (IMXT) and flattening filter free volumetric modulated arc therapy (FFF-VMAT (6x and 10x)) can maintain equal or better dose coverage than standard volumetric modulated arc therapy (Std-VMAT) while reducing doses to organs at risk (OARs). Methods: Bolus-ECT with IMXT, FFF-VMAT, and Std-VMAT treatment plans were produced for ten post-mastectomy radiotherapy (PMRT) patients previously treated at our clinic. The treatment plans were created on commercially available treatment planning system (TPS) and all completed treatment plans were reviewed and approved by a radiation oncologist. The plans were evaluated based on planning target volume (PTV) coverage, tumor control probability (TCP), dose homogeneity index (DHI), conformity index (CI), and dose to organs at risk (OAR). Results: All techniques produced clinically acceptable PMRT plans. Overall, Bolus-ECT with IMXT exhibited higher maximum dose compared to all VMAT techniques. Bolus-ECT with IMXT and FFF-VMAT10x had slightly improved TCP over FFF-VMAT6x and Std-VMAT. However, all VMAT techniques showed improved CI and DHI over Bolus-ECT with IMXT. All techniques showed very similar mean lung dose. Bolus-ECT with IMXT exhibited a reduced mean heart dose over Std-VMAT. Both FFF-VMAT techniques had higher mean heart dose compared to Std-VMAT. In addition, Bolus-ECT with IMXT was able to reduce mean dose to the contralateral breast compared to Std-VMAT and both FFF-VMAT techniques had comparable but slightly reduced dose compared to Std-VMAT. Conclusion: This work has shown that Bolus-ECT with IMXT produces clinically acceptable plans while reducing OAR doses. Both FFF-VMAT techniques are comparable to Std-VMAT with slight improvements. Even though all VMAT techniques produce more homogenous and conformal dose distributions, Bolus-ECT with IMXT is a viable option for treating post-mastectomy patients possibly leading to reduced risks of normal tissue complications.

60 APPLIED LIFE SCIENCES↗