Search NASA⌕ Search

SEARCH · Search NASA

Results for “coordinated control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Coordination Chemistry as a Universal Strategy for a Controlled Perovskite Crystallization

The most efficient and stable perovskite solar cells (PSCs) are made from complex mixture of precursors, which are practically always dissolved in combinations of the volatile (and toxic) N, N-Dimethylformamide (DMF), and the non-volatile (and green) dimethyl sulfoxide (DMSO) solvents. Typically, to then form a thin film, an extreme oversaturation of the perovskite precursor is initiated to trigger nucleation sites, e.g. by vacuum, an airstream or a so-called antisolvent. Unfortunately, most such oversaturation triggers do not expel the lingering (and highly coordinating) DMSO, which is highly coordinating, from the thin films; this detrimentally affects long-term stability. Here, for the first time, we introduce (the green) dimethyl sulfide (DMS) as a novel nucleation trigger for perovskite films combining, uniquely, high coordination and high vapor pressure. More precisely, DMS coordinates more strongly than all currently used solvents, hence replacing them, including DMSO, effectively during film formation. Crucially, DMS also has among the highest vapor pressures reported in literature, thus effectively leaving the thin film shortly after formation. This gives DMS a universal scope: DMS replaces other solvents by coordinating more strongly and removes itself once the film formation is finished. To demonstrate this novel coordination chemistry approach, we process MAPbI 3 PSCs, typically dissolved in hard-to-remove (and green) DMSO achieving 21.6% efficiency, among the highest reported efficiencies for this system. To confirm the universality of our strategy, we tested DMS for FAPbI 3 as another composition, which showed higher efficiency of 23.5% compared to 20.9% for fabricated device with CB. Finally, this work provides a universal strategy to control perovskite crystallization using coordination chemistry heralding the revival of perovskite compositions with pure DMSO, such as MAPbI 3 .

36 MATERIALS SCIENCE↗

Offline Arterial Signal Timing Optimization for Closely Spaced Intersections

The stop-and-go driving behavior at a busy arterial causes a significant amount of fuel waste and emissions that could be reduced. For closely spaced intersections, the traditional bottom-up signal timing approach could fail under high volumes when the queues reach the upstream intersections. A well-coordinated arterial should manage the queue length to prevent the control from failing. Traditionally, coordination among signalized intersections for an arterial means finding the good offsets for each intersection. The control of the intersections along an arterial can also be coordinated by optimizing splits. Splits impact the capacity of an intersection. Similar to the highway, the capacity drop could cause growing queues. This work is based on the Virtual Phase-Link (VPL) model, a street traffic model designed for online traffic model predictive control, to obtain a top-down offline arterial signal timing. The VPL-based model can guarantee capacity consistency in intersections along an arterial. We, therefore, adopted the VPL-based model and developed an offline signal timing optimization approach. The proposed timing derived from the VPL-based offline signal timing optimization showed very good results in simulation. We also collected field experiment data, which demonstrated overall energy reductions and speed improvements on some sections of the study arterial.

47 OTHER INSTRUMENTATION↗

Control of Behind-the-Meter Resources for Enhancing the Resilience of Residential Buildings

There is increased concern about the impacts of frequent power outages, caused primarily by extreme weather conditions. With increasing behind-the-meter resources such as solar photovoltaics (PV), battery energy storage, and controllable loads, these resources - if properly coordinated - can meet critical loads even during an outage. Resilience building controls can coordinate and operate these resources to enhance the resiliency of buildings supporting critical loads for longer duration. In this paper, we present two resilience building controls: rule-based control and model predictive control (MPC). We simulated various scenarios considering different locations, seasons, outage types, and times of outages to evaluate the performance of resilience controls. The results show that MPC-based control can enhance resilience up to 65% compared to rule-based control. Similarly, PV self-consumption and occupant thermal comfort both increase during outages with MPC-based control.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Strategy for distributed controller defence: Leveraging controller roles and control support groups to maintain or regain control in cyber-adversarial power systems

Distributed controllers play a prominent role in electric power grid operation. The coordinated failure or malfunction of these controllers is a serious threat, where the resulting mechanisms and consequences are not yet well-known and planned against. If certain controllers are maliciously compromised by an adversary, they can be manipulated to drive the system to an unsafe state. The authors present a strategy for distributed controller defence (SDCD) for improved grid tolerance under conditions of distributed controller compromise. The work of the authors’ first formalises the roles that distributed controllers play and their control support groups using controllability analysis techniques. With these formally defined roles and groups, the authors then present defence strategies for maintaining or regaining system control during such an attack. A general control response framework is presented here for the compromise or failure of distributed controllers using the remaining, operational set. The SDCD approach is successfully demonstrated with a 7-bus system and the IEEE 118-bus system for single and coordinated distributed controller compromise; the results indicate that SDCD is able to significantly reduce system stress and mitigate compromise consequences.

97 MATHEMATICS AND COMPUTING↗

Controlling Cation-Cation Interactions in Uranyl Coordination Dimers by Varying the Length of the Dicarboxylate Linker

The chemistry of linear uranyl(V/VI) dioxo cations, [O yl –U–O yl ] +/2+ , is dominated by coordination of uranium in the equatorial plane. Effects of this constraint were evaluated by experiment and theory for gas-phase mixed-valence U V/VI coordination dimers in which uranyl moieties are linked by alkyl dicarboxylates, [(UO 2 + )(UO 2 2+ )(OOC-(CH 2 ) n-2 -COO 2– ) 2 ] – (n = 3–12). Faster O 2 -addition to dimers with short linkers n = 3 and 4, vs. n ≥ 5, suggests a structural difference. Computed structures with the shortest linkers have bridging dicarboxylates and nearly parallel, non-interacting uranyls. Longer linkers, n = 5–7, accommodate uranyl orientations with distinct U V –U VI end-on cation-cation interactions (CCIs), whereby Lewis base O yl from U V coordinates to the acid U VI , denoted as U V O yl ···U VI . The dimer structure for n = 8 has a U V –U VI side-on diamond-shape CCI, with U V O yl ···U VI and U VI O yl ···U V interactions. Addition of O 2 to the n = 4 and 5 dimers yields [(UO22+)2(OOC-(CH2)n-2-COO2–)2(O2–)]–, with U V oxidized to U VI and O 2 reduced to O 2 – . Whereas O 2 can associate to and oxidize the exposed U V center for dimers with n = 3 and 4, the more crowded U V site in the CCI structures inhibits O 2 addition. Finally, the results demonstrate rational structural control of uranyl-uranyl bonding and reactivity in small coordination complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local Phasor-Based Control of DER Inverters for Voltage Regulation on Distribution Feeders

We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.

42 ENGINEERING↗

Local Atomic Configuration Control of Superconductivity in the Undoped Pnictide Parent Compound BaFe 2 As 2

Emergent superconductivity is strongly correlated with the symmetry of local atomic configuration in the parent compounds of iron-based superconductors. While chemical doping or hydrostatic pressure can change the local geometry, conventional approaches do not provide a clear pathway in predictably tuning the detailed atomic arrangement due to the parent compound’s complicated structural deformation in the presence of the tetragonal-to-orthorhombic phase transition. Here, we demonstrate a systematic approach to manipulate local structural configurations in BaFe 2 As 2 epitaxial thin films by controlling two independent structural factors, orthorhombicity (in-plane anisotropy) and tetragonality (out-of-plane/in-plane balance), from lattice parameters. We tune superconductivity without doping utilizing both structural factors separately and controlling local tetrahedral coordination in the designed thin film heterostructures with substrate clamping and biaxial strain. We further show this allows quantitative control of the structural phase transition, the associated magnetism, and superconductivity in parent material BaFe 2 As 2 . Furthermore, this approach will advance the development of tunable thin film superconductors in a reduced dimension.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Computational Fluid Dynamics Simulation Study of Active Power Control in Wind Plants

This paper presents an analysis performed on a wind plant's ability to provide active power control services using a high-fidelity computational fluid dynamics-based wind plant simulator. This approach allows examination of the impact on wind turbine wake interactions within a wind plant on performance of the wind plant controller. The paper investigates several control methods for improving performance in waked conditions. One method uses wind plant wake controls, an active field of research in which wind turbine control systems are coordinated to account for their wakes, to improve the overall performance. Results demonstrate the challenge of providing active power control in waked conditions but also the potential methods for improving this performance.

17 WIND ENERGY↗

The control network of Rhea

A control network of the Saturnian satellite Rhea has been established photogrammetrically from pictures taken by the two Voyager spacecraft. Coordinates of 288 control points on Rhea have been computed and listed; some of these are identified on the preliminary U.S. Geological Survey map of Rhea and many of the control point features have been named. Pixel measurements of these points were made on 81 Voyager 1 and 3 Voyager 2 pictures. The longitude system on Rhea is defined by the crater Tore; the 340 deg meridian passes through the center of this crater. The mean radius of Rhea has been determined at 764 + or - 4 km.

Davies, M. E.↗

The control network of Iapetus

A control network of the Saturnian satellite Iapetus has been established photogrammetrically from pictures taken by the two Voyager spacecraft. Coordinates of 62 control points have been computed and listed; pixel measurements of these points were made on 14 Voyager 1 and 66 Voyager 2 pictures. Some of these points are identified on the preliminary U.S. Geological Survey map of Iapetus and many are identified by name. The Voyager 1 and Voyager 2 pictures covered limited regions of the satellite's surface and contained no overlapping areas. The longitude system on Iapetus is defined by the crater Almeric; the 276 deg meridian passes through the center of this crater. The obliquity of Iapetus has been measured as 0.4 deg + or - 1.6 deg. The mean radius of Iapetus has been determined at 718 + or - 8 km.

Davies, M. E.↗

Supercapacitor to Provide Ancillary Services: Preprint

Supercapacitor technology has reached a level of maturity as a viable energy storage option available to support a modern electric power system grid; however, its application is still limited because of its energy capacity and the cost of the commercial product. In this paper, we demonstrate transient models of supercapacitor energy storage plants operating in coordination with run-of-the-river (ROR), doubly-fed induction generator hydropower plants (HPP) using a system control concept and architecture developed. A detailed transient model of a supercapacitor energy storage device is coupled with the grid via a three-phase inverter/rectifier and bidirectional DC-DC converter. In addition, we use a version of a 14-bus IEEE test case that includes the models of the supercapacitor energy storage device, ROR HPPs, and synchronous condensers that use the rotating synchronous generators of retired coal-powered plants. The purpose of the synchronous condensers is to enhance the system stability by providing voltage and reactive power control, provide power system oscillations damping, and maintain system inertia at secure levels. The control layer provides coordinated, decentralized operation of distributed ROR HPPs and energy storage as aggregate support to power system operations.

25 ENERGY STORAGE↗

Distributed Control of Inverter-Based Lossy Microgrids for Power Sharing and Frequency Regulation Under Voltage Constraints

This paper presents a new distributed control framework to coordinate inverter-interfaced distributed energy resources (DERs) in island microgrids. We show that under bounded load uncertainties, the proposed control method can steer the microgrid to a desired steady state with synchronized inverter frequency across the network and proportional sharing of both active and reactive powers among the inverters. We also show that such convergence can be achieved while respecting constraints on voltage magnitude and branch angle differences. The controller is robust under various contingency scenarios, including loss of communication links and failures of DERs. The proposed controller is applicable to lossy mesh microgrids with heterogeneous R/X distribution lines and reasonable parameter variations. Simulations based on various microgrid operation scenarios are also provided to show the effectiveness of the proposed control method.

Microgrid Control, Droop Control, Frequency Synchr↗

Nonlinear Multiple Models Adaptive Secondary Voltage Control of Microgrids

This article proposes a model-free secondary voltage control (SVC) for microgrids (MG) using nonlinear multiple models adaptive control. Firstly, a linear robust adaptive controller is designed to guarantee the voltage stability in the bounded-input- bounded-output (BIBO) manner so as to meet the operation requirements of MGs. Secondly, a nonlinear adaptive controller is developed to improve the voltage tracking performance with the help of artificial neural networks (ANNs). A switching mechanism for coordinating such two controllers is designed to guarantee the closed-loop stability while achieving accurate voltage tracking. Here, by an online identification based on the input and output data of MGs, the proposed method does not resort to any apriori information of system model and primary control, thus exhibiting good robustness, ease of deployment and disturbance rejection.

17 WIND ENERGY↗

Control system design for a small pressurized water reactor - 141

Small Pressurized Water Reactors (SPWR) have unique designs from the commercial large Pressurized Water Reactors (PWRs). Integral design is adopted. There are no hot legs and cold legs between the reactor core and the steam generators like in the PWR. Strong interactions exist among different loops. The pressure vessel is large in volume and the coolant inventory is also in a large amount. The inertia of the coolant is large and it takes more time for the primary system to respond to disturbances. The steam generator adopts the once-through design and the water inventory is small. The steam generator is very sensitive to disturbances. These unique characteristics challenge the control system design of SPWR. Relap5 is used to model the SPWR. Steady-state simulation is performed to verify the correctness of the model. In the reactor power control system, both the reactor fission power and the coolant average temperature are regulated by the control rod reactivity. In the feedwater flow control system, the coordination between the reactor and the turbine is considered and coolant average temperature is adopted as one measurable disturbance for the control system. The coolant pressure is adjusted based on the heaters and spray in the pressurizer. The water level in the pressurizer is controlled by the charging flow and the letdown flow is compensated to calculate the charging flow needed. Transient simulations are carried out to evaluate the control system performance. When the reactor is perturbed, the reactor can be stabilized under the control system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mariner 9 control net of Mars, April 1973

A planet-wide geodetic control net of Mars that is based on the Mariner 9 television pictures has been in the process of being computed since January 1972. Results of the computations as of April 1973 are presented. Areocentric and areographic coordinates of 1340 control points have been computed using 613 frames and are presented tabularly. These coordinates will be revised as additional points and frames are added to the computation in the future.

Davis, M. E.↗

On the Traffic Impacts of Optimally Controlled Connected and Automated Vehicles

The implementation of connected and automated vehicle (CAV) technologies enables a novel computational framework for real-time control actions aimed at optimizing energy consumption and associated benefits. Several research efforts reported in the literature to date have proposed decentralized control algorithms to coordinate CAVs in various traffic scenarios, e.g., highway on-ramps, intersections, and roundabouts. However, the impact of optimally coordinating CAVs on the performance of a transportation network has not been thoroughly analyzed yet. In this paper, we apply a decentralized optimal control framework in a transportation network and compare its performance to a baseline scenario consisting of human-driven vehicles. We show that introducing of CAVs yields radically improved roadway capacity and network performance.

Zhao, Liuhui↗

Advanced Photovoltaic Inverter Control Development and Validation in a Controller-Hardware-in-the-Loop Test Bed

Penetration of solar photovoltaic (PV) installations into the grid has increased in recent years. In the past, photovoltaic installations have not included grid-support functionality. Grid support functions including Volt-VAR (VVAR), Frequency-Watt (FW), Volt-Watt (VW), frequency/voltage-ride through, as well as other inverter functions such as anti-islanding are recommended by standards such as IEEE 1547 to allow PV inverters to contribute to acceptable operation and stability of distribution systems with high penetrations of PV and to ensure predictable response of the PV inverters. First, low-level and high-level grid support inverter control functions were developed and tested in simulation. The developed controller is able to integrate advanced controller functions in a coordinated approach, avoiding any conflict between the different control objectives. The algorithms were then programmed on an off-the-shelf embedded controller that included a dual-core CPU and FPGA. The details of the high-level grid support function and the lower level switching control will be presented. Second, this programmed controller is tested using a controller-hardware-in-the-loop (CHIL) test bed setup using an FPGA-based real-time simulator. The CHIL setup has the capability to run at a 500 nano-second time-step to accommodate the 20 kHz switching frequency of the developed controller. The advanced control function and CHIL test bed details provided here will aide future researchers to design, implement, and test advanced inverter functions for PV inverters.

14 SOLAR ENERGY↗