Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Cybersecurity Guide for Distributed Wind

Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This document is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). We discuss common distributed wind architectures and describe their role in the larger power system, pointing out some of the key connections to be aware of. Cybersecurity cannot exist in a vacuum, but rather must consider all the system and all its connections holistically. The role of distributed wind and the functions it can serve are described to gain understanding of the full range of capabilities. The purpose and application of relevant standards that may apply to certain distributed wind systems is presented. These standards may not apply to all installations, but even for systems that are not required to meet these standards they can be a good reference for best practices. A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). Finally, we present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Communication-Constrained Robust Control and Learning of Grid-Connected

The electric grid of things (EGoT) promises great potential for innovative grid services by tapping into vast load flexibility. However, the unique characteristics of EGoT, being a part of the cyber-physical electric power system, present both opportunities and challenges, especially concerning supply-demand balancing, stability, and communication constraints. Traditionally, centralized control was employed to ensure balance and stability in power systems. However, with the massive influx of EGoT devices, new strategies are needed to efficiently coordinate and control these distributed devices for optimal grid operations. While some studies have explored efficiency and economic models, there remains a gap in ensuring reliability under everyday operations and resilience during extreme conditions. Addressing this gap, this project develops the technology for an Energy Service Interface (ESI) that includes novel pricing, control, learning, and distributed optimization algorithms, which will enable utilities to recruit EGoT assets for crucial grid services such as load flexibility, voltage regulation, and situation-awareness. The key novelty of the proposed technology is the careful distribution of learning and control functions across utility and EGoT asset owners such that provably efficient and resilient grid operations are attained while respecting communication and information-exchange constraints. Specifically, the project team develops machine-learning enhanced load modeling methods to allow EGoT asset owners to learn their load capability and flexibility, and develops pricing-based and decentralized learning-based control so that asset owners can coordinate to meet system-wide demand-supply balance and reliability goals. For extreme situations involving high-impact, low-probability catastrophic events (termed the “black-sky” events), the team also develops (1) a “Feeder-Operating Center-on-a-Laptop” (FOCAL) software that can assist utility personnel in leveraging EGoT assets to accelerate the service recovery of damaged feeders, and (2) distributed optimization algorithms that can coordinate the operation points of EGoT devices under severe communication constraints. The proposed technology has been extensively tested and evaluated through simulations and on a testbed. In summary, as we transition into a more interconnected and digital power grid era, our project’s findings and developments offer a pivotal step toward guaranteeing both efficiency and resilience in the face of both everyday operations and rare “black-sky” events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

WRS Capabilities Booklet [Slides]

WRS is the digital backbone of the Weapons Program—delivering trusted data assets, cyber-assured software and systems, and AI-enabling software—that transform insights into decisive action. We empower physicists, engineers, researchers, and scientists to think faster, act strategically, and stay ahead in an ever-evolving threat landscape. Our efforts ensure critical nuclear weapons data remains secure, accessible, and usable—supporting mission-critical work, informed decision making, and scientific advancement at LANL and across the Nuclear Security Enterprise (NSE).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Oakland University Cybersecurity Center (Final Scientific/Technical Report)

This report summarizes the outcomes of Award DE-CR0000023, “Oakland University Cybersecurity Center,” a 31-month project funded by the U.S. Department of Energy Office of Cybersecurity, Energy Security, and Emergency Response (CESER). The project addressed cybersecurity risks facing small and medium-sized manufacturers (SMMs) transitioning to Industry 4.0. The project integrated customer discovery, applied research, and cybersecurity training development. A total of 51 cybersecurity assessments identified significant gaps in baseline practices, incident response, and workforce capability. Research efforts produced a scalable mitigation framework tailored to SMM environments, and workforce analysis identified persistent talent gaps. Eight cybersecurity training modules were developed and deployed via Oakland University’s Professional and Continuing Education (PACE) platform. All objectives were completed, with 98.93% federal budget utilization and cost share exceeding requirements. The project establishes a scalable model for strengthening cybersecurity resilience and workforce capacity across U.S. manufacturing supply chains.

24 POWER TRANSMISSION AND DISTRIBUTION↗

APIS: Honeybee Foraging Task Assignment for Use in Uncertain and Unreliable Environments

Multiagent Cyber-Physical-Human (CPH) systems in realistic environments operate under uncertain conditions. Communication among agents, aimed at reducing the uncertainty, is itself subject to uncertainty. We propose to manage uncertainties in autonomous, long-duration operations of multiagent systems via a modified Honeybee Foraging (HBF) behavioral scheme. The resulting system, Autonomous Persistent Intelligent Swarm (APIS),incorporates two new behaviors to ameliorate informational uncertainty. When “scouting”, agents are tasked based on informational quality and reliability rather than solely on priorities. When “dancing”, agents are tasked to rendezvous with other dancing agents to exchange information at close range, where successful communication is guaranteed. When coupled with uncertainty-aware modeling across agents, these behaviors improve situational awareness and resilience of the system, enabling it to function under more uncertain conditions arising during long-duration missions.

Autonomous systems↗

APIS: Honeybee Foraging Task Assignment for Use in Uncertain and Unreliable Environments

Multiagent Cyber-Physical-Human (CPH) systems in realistic environments operate under uncertain conditions. Communication among agents, aimed at reducing the uncertainty, is itself subject to uncertainty. We propose to manage uncertainties in autonomous, long-duration operations of multiagent systems via a modified Honeybee Foraging (HBF) behavioral scheme. The resulting system, Autonomous Persistent Intelligent Swarm (APIS),incorporates two new behaviors to ameliorate informational uncertainty. When “scouting”, agents are tasked based on informational quality and reliability rather than solely on priorities. When “dancing”, agents are tasked to rendezvous with other dancing agents to exchange information at close range, where successful communication is guaranteed. When coupled with uncertainty-aware modeling across agents, these behaviors improve situational awareness and resilience of the system, enabling it to function under more uncertain conditions arising during long-duration missions.

Autonomous systems↗

Cybersecurity Guide for Distributed Wind Presentation

This presentation communicates information about the MIRACL project Resilience Metrics report and Resilience Framework report. It was created for the 2021 MIRACL advisory board meeting. Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This presentation is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). We present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

Cyber-physical Resilient Interoperable Microgrid Networks

The paper presents the results of an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyberphysical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hypernetwork Science: From Multidimensional Networks to Computational Topology

As data structures and mathematical objects used for complex systems modeling, hypergraphs sit nicely poised between on the one hand the world of network models, and on the other that of higher-order mathematical abstractions from algebra, lattice theory, and topology. They are able to represent complex systems interactions more faithfully than graphs and networks, while also being some of the simplest classes of systems representing topological structures as collections of multidimensional objects connected in a particular pattern. In this paper we discuss the role of (undirected) hypergraphs in the science of complex networks, and provide a mathematical overview of the core concepts needed for hypernetwork modeling, including duality and the relationship to bicolored graphs, quantitative adjacency and incidence, the nature of walks in hypergraphs, and available topological relationships and properties. We close with a brief discussion of two example applications: biomedical databases for disease analysis, and domain-name system (DNS) analysis of cyber data.

Joslyn, Cliff A.↗

Hypothetical Solar Cyberattack Scenarios and Impacts

This report offers approachable, plausible scenarios of cyberattacks affecting photovoltaic assets and interconnected infrastructure. It may be used by State Energy Officials and Public Utility Commission Staff to educate themselves on the potential consequences of these scenarios and the practical, high-level actions that may be implemented now to mitigate future impacts. It highlights plausible consequences of inadequate cyber provisions for PV systems and offers potential state actions to alleviate the identified risks.

14 SOLAR ENERGY↗

Cyber risk assessment and investment optimization using game theory and ML-based anomaly detection and mitigation for wide-area control in smart grids

The electric power grid is increasingly becoming susceptible to cyber attacks that exploit vulnerabilities in the smart grid control, information, and physical layers. Successful cyber attacks can have catastrophic impacts on the social and economic well-being of any nation all over the globe. It has, thus, become imperative to secure the smart grid against such adversarial actions to ensure stable, secure, and reliable operation of the grid. The existing research and industry practices prove to be inadequate in terms of providing pragmatic and effective defense methodologies and measures for long-term cybersecurity planning and real-time cybersecurity for grid operation. For example, existing works lack models that incorporate uncertain behavior of cyber-attackers and pragmatic defense measures for cyber risk assessment and cybersecurity investment optimization which often provide unreliable and strictly qualitative solutions to these problems. At the same time, with the growing number of cyber incidents in the grid, there still exists a need to develop attack-resilient algorithms for wide-area monitoring, protection, and control (WAMPAC) applications like the wide-area voltage control systems (WAVCS) for Flexible AC Transmissions Systems (FACTS) that lack in scalable and feasible solutions from the cybersecurity perspective. This dissertation proposes novel models and methodologies for: (1) Cybersecurity planning, and (2) Cybersecurity for system operation. The cybersecurity planning is achieved through cyber risk assessment and cybersecurity resource investment optimization for long-term cybersecurity of the grid using game theory and attack-defense trees. Cybersecurity for system operation consists of development of cyber anomaly detection and mitigation algorithms for flexible AC transmission system (FACTS) controller-based wide-area voltage control systems (WAVCS) using machine learning (ML), and software defined networking-based moving target defense network routing for achieving real-time cyber-physical security for grid operations. This is followed by hardware-in-the-loop (HIL) implementation and evaluation of these attack prevention, detection, and mitigation algorithms and methodologies showcasing their feasibility in a close to real-world environment. For cybersecurity planning, a novel approach involving a combination of game theory and attack defense trees (ADT) for optimal cybersecurity resource allocation in the smart grid is proposed. This methodology involves modeling of the cyber-physical smart grid substations as ADTs, defining attacker costs, defense costs, and attack probabilities for attack access points. Using game theoretical formulation, optimal defense strategies for the defender of the system to invest cybersecurity resources in the grid are obtained. Additionally, a game-theoretic framework is developed for quantitative cyber-physical risk assessment of the grid under a dynamically changing cyber threat space and uncertain behavior of cyber attackers which is further used to optimize investments in the smart grid's cybersecurity resources. The attacker, defender, and the smart grid system are modeled while incorporating attacker-stochasticity and federal guidelines for smart grid cybersecurity. This allows quantification of threat, vulnerabilities, and attack impact of the grid for quantitative risk assessment. The defender's budget to invest in the security resources in the grid is optimized based on the strategies leading to minimum system risk. The evaluation of the proposed solutions highlight the feasibility for practical implementation of these methodologies and algorithms in the smart grid, while taking the federal requirements and guidelines for smart grid security into consideration. For achieving cybersecurity for system operation, attack prevention, detection, and mitigation algorithms and methodologies are developed specifically for FACTS-based WAVCS. Anomaly detection and mitigation in the WAVCS are achieved using algorithms based on machine learning which involves offline training and testing of ML models with CPS datasets incorporating physics-based features that allow accurate distinction between system faults and cyber attacks. For attack prevention, a methodology based on software defined network (SDN)-based moving target defense (MTD) network routing is proposed that enables prevention of Denial of Service (DoS) type attacks on the smart grid communication system. Subsequently, these methodologies and algorithms are implemented and evaluated on an HIL testbed that allows for real-time attack prevention, detection, and mitigation of emulated cyber attacks on the WAVCS in a close to real-world environment. The results show highly accurate and efficient performance of the implemented algorithms and methodologies with the smart grid system operating within the NERC's system operation limits even in the presence of DoS and data integrity cyber attacks. This work opens up future research opportunities in other directions such as (1) Expanding cybersecurity planning methodologies to real-time cyber contingency analysis with different game formulations; and (2) Applying the cybersecurity for system operation algorithms to broader categories of wide-area control applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Cyber-Informed Engineering for Cyber Defense Workbook

This workbook was prepared for a detailed workshop in Cyber-Informed Engineering. It is designed to provide an audience of electrical cooperative engineering staff with an opportunity to practice leveraging the principles of Cyber-Informed Engineering for a hypothetical system upgrade. This workbook contains material describing the fictional project, information about Cyber-Informed Engineering, hands-on exercises, and a copy of the slides presented during the workshop. It can stand alone as a CIE resource.

42 ENGINEERING↗

A computer program for estimation from incomplete multinomial data

Coding is given for maximum likelihood and Bayesian estimation of the vector p of multinomial cell probabilities from incomplete data. Also included is coding to calculate and approximate elements of the posterior mean and covariance matrices. The program is written in FORTRAN 4 language for the Control Data CYBER 170 series digital computer system with network operating system (NOS) 1.1. The program requires approximately 44000 octal locations of core storage. A typical case requires from 72 seconds to 92 seconds on CYBER 175 depending on the value of the prior parameter.

Credeur, K. R.↗

An Active Detection Scheme for Sensor Spoofing in Grid-tied PV Systems

In this paper an active detection scheme for sensor spoofing (manipulated externally via a cyber attack) in grid-tied PV systems is discussed. The core of the proposed active detection scheme is to introduce a private (secret) watermarking signal into the control inputs of the DC-DC converter and DC-AC inverter stages to detect any malicious spoofing (manipulation) of voltage/current sensor measurements controlling both the DC-DC converter maximum power point tracking (MPPT) stage and the DC-AC inverter of the grid-tied PV system. Several types of possible spoofing mechanisms (attack models) are discussed. The proposed sensor spoofing attack detector system consists of injecting a small magnitude of digital watermarking signal (DWS) and conduct three statistical watermark tests on the reported sensor measurements to determine if a) the proposed system is healthy and operating as expected b) if sensor signals were spoofed (manipulated) externally or c) if a particular sensor is malfunctioning due to a faulty hardware. It is shown via extensive simulations that the proposed DWS approach is robust in detecting malicious external manipulation of sensors controlling the grid tied PV system. A testing platform is currently under development and the experimental results will be discussed in the conference presentation.

Ibrahim, Hasan↗

On the Application of Cyber-Informed Engineering (CIE)

The 2023 National Cybersecurity Strategy has recommended a transition to secure-by-design methodologies in critical infrastructure. This paper presents the adoption of the National Cyber-Informed Engineering (CIE) Strategy as initiated by the U.S. DOE’s CESER office, advocating for the integration of cybersecurity at the earliest stages of system design. The strategy targets design engineers responsible for energy infrastructure to embed CIE principles within the engineering lifecycle, thus enhancing cyber resilience. This paper discusses the expansion of secure-by-design concepts to cyber-physical systems, moving beyond traditional IT security to include engineering considerations that can mitigate cyber risks through design choices. The paper introduces Digital Risk Management, balancing traditional cybersecurity with CIE to reduce both likelihood and impact of cyber threats. A set of CIE starter questions derived from 12 core principles is detailed, aiding engineers to consider cybersecurity in their designs and highlights the importance of CIE in anticipating and reducing the impacts of cyber attacks, suggesting that such integration is essential for national security and infrastructure resilience.

42 ENGINEERING↗

Cybersecurity Considerations for the Liquified Natural Gas Sector

Due to the highly volatile nature of Liquified Natural Gas (LNG) and the systems required for generation and safe containment, it is likely a targeted cyber-attack on LNG control and safety systems will have a significant economic impact on energy supplies and prices. Moreover, if the interconnected operational technology (OT) devices within LNG systems are exploited to malfunction, the repair and recertification process will almost certainly be longer than for natural gas (NG) systems.

03 NATURAL GAS↗

BioSecure Digital Twin: Manufacturing Innovation and Cybersecurity Resilience

U.S. national security, prosperity, economy, and well-being require secure, flexible, and resilient Biopharmaceutical Manufacturing. The COVID-19 pandemic reaffirmed that the biomedical production value-chain is vulnerable to disruption and has been under attack from sophisticated nation-state adversaries. Current cyber defenses are inadequate, and the integrity of critical production systems and processes are inherently vulnerable to cyber-attacks, human error, and supply chain disruptions. The following chapter explores how a BioSecure Digital Twin will improve U.S. manufacturing resilience and preparedness to respond to these hazards by significantly improving monitoring, integrity, security, and agility of our manufacturing infrastructure and systems. The BioSecure Digital Twin combines a scalable manufacturing framework with a robust platform for monitoring and control to increase U.S. biopharma manufacturing resilience. Then, the chapter discusses some of the inherent vulnerabilities and challenges at the nexus of health and advanced manufacturing. Next, the chapter highlights that as the Pandemic evolves, we need agility and resilience to overcome significant obstacles. This section highlights an innovative application of Cyber Informed Engineering to developing and deploying a BioSecure Digital Twin to improve the resilience and security of the biopharma industrial supply chain and production processes. Finally, the chapter concludes with a process framework to complement the Digital Twin platform, called the Biopharma (Observe, Orient, Decide, Act) OODA Loop Framework (BOLF), a four-step approach to decision-making outputs from the Digital Twin. The BOLF will help end users leverage twin technology by distilling the available information, focusing the data on context, and rapidly making the best decision while remaining cognizant of changes that can be made as more data becomes available.

99 GENERAL AND MISCELLANEOUS↗

CIE Curriculum Guide (V.2.0)

The Cyber-Informed Engineering (CIE) Curriculum Guide offers a comprehensive framework, guidance, and resources for integrating CIE into university-level engineering programs and related educational activities. The primary goal is to help educators adopt CIE principles into their teaching to produce future engineers and technicians who understand digital risks in modern engineered systems, thereby addressing the nation’s infrastructure resilience needs. This guide outlines practical integration examples, links to resources to accelerate CIE adoption, and shares insights from partner academic institutions on various implementation strategies. CIE is a framework for embedding engineered controls that mitigate the impact of cyber-attacks in any cyber-physical system used in critical energy infrastructure and other sectors. Developed by the U.S. Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), the National Cyber-Informed Engineering Strategy emphasizes embedding CIE into formal education, training, and credentialing. This guide supports this strategic objective by providing examples of integrating CIE concepts into engineering curricula, from class activities to new courses and certificate programs. The importance of educating cyber-informed engineers is underscored by the evolving cybersecurity threats facing engineered systems. As industrial control systems (ICS) increasingly incorporate digital technologies, the responsibility for security extends to both cyber professionals and engineers. CIE addresses critical gaps in designing and protecting physical systems with digital components against cyber risks, ensuring engineers consider digital risk throughout the engineering design lifecycle. Currently, engineering education does not routinely include cyber-informed principles, highlighting a gap in addressing modern engineering system risks. This guide advocates for updating engineering curricula to include digital risk management as a fundamental element. By doing so, future engineers will be equipped to design resilient systems that mitigate digital risks from the outset. Through this guide, engineering faculty can integrate CIE into their curricula, bridging the gap between digital risk and engineering. This approach prepares a cyber-informed workforce capable of safeguarding the cyber-physical systems crucial to national security and public welfare. By embedding CIE into education and training, institutions can produce engineers and technicians who can effectively mitigate cyber impacts throughout the engineering design lifecycle, resulting in more secure critical infrastructures.

42 - ENGINEERING↗