Search NASA⌕ Search

SEARCH · Search NASA

Results for “databases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Continuous Reliability Enhancement for Wind (CREW) Database: Wind Plant Reliability Benchmark

To benchmark the current U.S. wind turbine fleet reliability performance and identify the major contributors to component-level failures and other downtime events, the Department of Energy (DOE) funded the development of the Continuous Reliability Enhancement for Wind (CREW) database by Sandia National Laboratories. This report is the second annual Wind Plant Reliability Benchmark, to publically report on CREW findings for the entire wind industry. The CREW database uses both high resolution Supervisory Control and Data Acquisition (SCADA) data from operating plants and Strategic Power Systems’ (SPS) ORAPWind® (Operational Reliability Analysis Program for Wind) data, which consists of downtime and reserve event records and daily summaries of Generating, Unavailable, and Reserve time for each turbine. Together, these data are used as inputs into CREW’s reliability modeling. The results presented here include: the primary CREW Benchmark statistics (operational availability, utilization, capacity factor, mean time between events, and mean downtime); time accounting from an availability perspective; time accounting in terms of the combination of wind speed and generation levels; power curve analysis; and top system and component contributors to unavailability.

Peters, Valerie A.↗

Continuous Reliability Enhancement for Wind (CREW) database :

To benchmark the current U.S. wind turbine fleet reliability performance and identify the major contributors to component-level failures and other downtime events, the Department of Energy funded the development of the Continuous Reliability Enhancement for Wind (CREW) database by Sandia National Laboratories. This report is the third annual Wind Plant Reliability Benchmark, to publically report on CREW findings for the wind industry. The CREW database uses both high resolution Supervisory Control and Data Acquisition (SCADA) data from operating plants and Strategic Power Systems ORAPWindª (Operational Reliability Analysis Program for Wind) data, which consist of downtime and reserve event records and daily summaries of various time categories for each turbine. Together, these data are used as inputs into CREW s reliability modeling. The results presented here include: the primary CREW Benchmark statistics (operational availability, utilization, capacity factor, mean time between events, and mean downtime); time accounting from an availability perspective; time accounting in terms of the combination of wind speed and generation levels; power curve analysis; and top system and component contributors to unavailability.

Hines, Valerie Ann-Peters↗

DARHT Axis II Cathode 12 (S/N 15) History as Recorded in the Historian and Shot Data Databases (DARHT Technical Note No. 501)

Long DARHT II injector cathode operating lifetimes are desirable for flash radiography of hydrodynamic tests at the dual-axis radiographic hydrotest facility (DARHT). The specification for cathode operating lifetime given to Spectra-Mat in the purchase orders for the 311X-M cathodes is ≥ 1000 hours at full operating temperature (~1120 °C). Of the five most-recent cathodes operated on DARHT II, only two have met this specification. It is desirable to have cathodes lifetimes considerably longer than the specified 1000 hours. In this report we present the thermal and vacuum history of cathode 12 (serial no. [S/N] 15), a 311X-M cathode, as recorded in the historian database and the shot data database. The hope is that by examining this history we can identify the parameter (or parameters) that are limiting the DARHT II 311X-M cathode lifetimes. This is the first in a series of 5 DARHT Tech Notes in which recent cathode thermal and vacuum histories are examined. The other tech notes in this series are DARHT Tech Notes Nos. 502 (cathode 13, S/N 19), 503 (cathode 14, S/N 20), 504 (cathode 15, S/N 21), and 505 (cathode 16, S/N 22). In DARHT Tech Note No. 506 we will compare the recorded thermal and vacuum histories of cathodes 12-16 and attempt to understand the cathode lifetime limitations based on the stored cathode data presented in DARHT Tech Notes 501-505 and other relevant information.

42 ENGINEERING↗

Database of Low-E Storm Window Energy Performance across U.S. Climate Zones (Task ET-WIN-PNNL-FY13-01_5.3)

This report describes process, assumptions, and modeling results produced in support of the Emerging Technologies Low-e Storm Windows Task 5.3: Create a Database of U.S. Climate-Based Analysis for Low-E Storm Windows. The scope of the overall effort is to develop a database of energy savings and cost effectiveness of low-E storm windows in residential homes across a broad range of U.S. climates using the National Energy Audit Tool (NEAT) and RESFEN model calculations. This report includes a summary of the results, NEAT and RESFEN background, methodology, and input assumptions, and an appendix with detailed results and assumptions by cliamte zone. Both sets of calculation results will be made publicly available through the Building America Solution Center.

54 ENVIRONMENTAL SCIENCES↗

DARHT Axis II Cathode 16 (S/N 22) History as Recorded in the Historian and Shot Data Databases

Long DARHT II injector cathode operating lifetimes are desirable for flash radiography of hydrodynamic tests at the dual-axis radiographic hydrotest facility (DARHT). The specification for cathode operating lifetime given to Spectra-Mat in the purchase orders for the 311X-M cathodes is ≥ 1000 hours at full operating temperature (~1120 oC). Of the five most-recent cathodes operated on DARHT II, only two have met this specification. It is desirable to have cathodes lifetimes considerably longer than the specified 1000 hours. In this report we present the thermal and vacuum history of cathode 16 (serial no. [S/N] 22), a 311X-M cathode, as recorded in the historian database and the shot data database. The hope is that by examining this history we can identify the parameter (or parameters) that are limiting the DARHT II 311X-M cathode lifetimes. This is the fifth in a series of 5 DARHT Tech Notes in which recent cathode thermal and vacuum histories are examined. The other tech notes in this series are DARHT Tech Notes Nos. 501 (cathode 12, S/N 15), 502 (cathode 13, S/N 19), 503 (cathode 14, S/N 20), and 504 (cathode 15, S/N 21). In DARHT Tech Note No. 506 we will compare the recorded thermal and vacuum histories of cathodes 12-16 and attempt to understand the cathode lifetime limitations based on the stored cathode data presented in DARHT Tech Notes 501-505 and other relevant information.

43 PARTICLE ACCELERATORS↗

Database of Low-e Storm Window Energy Performance across U.S. Climate Zones

This is an update of a report that describes process, assumptions, and modeling results produced Create a Database of U.S. Climate-Based Analysis for Low-E Storm Windows. The scope of the overall effort is to develop a database of energy savings and cost effectiveness of low-E storm windows in residential homes across a broad range of U.S. climates using the National Energy Audit Tool (NEAT) and RESFEN model calculations. This report includes a summary of the results, NEAT and RESFEN background, methodology, and input assumptions, and an appendix with detailed results and assumptions by cliamte zone.

energy savings, windows↗

Quality Assurance Procedures for ModCat Database Code Files

The Quality Assurance procedures used for the initial phase of the Model Catalog Project were developed to attain two objectives, referred to as “basic functionality” and “visualization.” To ensure the Monte Carlo N-Particle model input files posted into the ModCat database meet those goals, all models considered as candidates for the database are tested, revised, and re-tested.

MCNP↗

LBNL 2011 Inter-Laboratory Comparison for Laboratories Submitting Specular Data to the International Glazings Database (IGDB)

Laboratories that submit data to the International Glazings Database (IGDB) have to participate in an inter-laboratory comparison (ILC) every four years. This is a procedure that allow both contributors and database maintainers to confirm that the measurement capabilities of the laboratories are of high quality. All laminate and applied film samples are manufactured using the same batch of clear glass to allow for an investigation of the accuracy in the Optics 5 laminate deconstruction process. The IGDB contains optical information in the wavelength region between 300-2500 nm where transmittance as well as reflectance for both the front and the back surface is recorded. In addition to that emissivity, obtained through measurement of reflectance between 5 and 25 m, is recorded for both the front and back surface. The goal for submitters is to pass within the tolerances dictated by NFRC document 302 which states that transmittances should be within 1% and reflectance/emissivity withing 2%. As an organizing entity LBNL aims to educate and help submitters troubleshoot any issues that give rise to systematic errors. The ILC is a living ILC and does not necessarily contain the first result submitted by a lab. As errors are found submitters are encouraged to correct procedures or update equipment so that they are allowed to submit data to the IGDB. The risk of this practice is that if any of the recommended solutions introduces new systematic errors this will start to influence the average. Therefore this report tries to highlight the recommendations made so that they can be challenged.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Database of Renewable Energy and Energy Efficiency Incentives and Policies Final Technical Report

The Database of State Incentives for Renewables and Efficiency (DSIRE) is an online resource that provides summaries of all financial incentives and regulatory policies that support the use of renewable energy and energy efficiency across all 50 states. This project involved making enhancements to the database and website, and the ongoing research and maintenance of the policy and incentive summaries.

99 GENERAL AND MISCELLANEOUS↗

Analysis of SNL/MSU/DOE Fatigue Database Trends for Wind Turbine Blade Materials 2010-2015.

Wind turbine blades are designed to several major structural conditions, including tip deflection, strength and b uckling during severe loading, as well as very high numbers of fatigue cycles and various service environments. The MSU Database Program has, since 1989, addressed the broad range of properties needed for current and potential blade materials through stati c and fatigue testing and test development in cooperation with Sandia National Laboratories and wind industry and supplier partners. This report is the latest in a series, giving test results and analysis for the period 2010 - 2015. Program data are compiled in a public database [1] and other reports and publications given in the cited references. The report begins with an executive summary and introductory material including background discussion of previous related studies. Section 3 describes experimental methods including processing, test methods, instrumentation and test development. Section 4 provides static tension, compression and shear stress - strain properties in three directions using coupons sectioned from a thick infused unidirectional glass/epoxy laminate. The nonlinear, shear dominated static properties were characterized with loading - u nloading - reloading (LUR) tests in tension and compression to increasing load levels, for +-45O laminates. Section 5 explores the origins of tensile fatigue sensitivity in glass fiber dominated laminates with variations in fabric architecture including speci ally prepared fabrics and aligned strand laminates. Several types of resins are considered, with variations in resin toughness and bonding to fibers, as well as cure cycle variations for an epoxy. Conclusions are drawn as to the limits of tensile fatigue r esistance and the effects of resin type and fabric architecture, including the behavior of a commercial aligned glass strand product. Interactions between cyclic fatigue response and creep are addressed for off - axis (+-45O) glass/epoxy laminates in Sectio n 6. The nonlinear fatigue and creep stress - strain and cumulative strain response are characterized in tension and compression as a function of stress level, cycles and cumulative time, using square and sinewave loading over a broad range of frequency. The results are analyzed in terms of the cycles and cumulative time under load. A cumulative strain failure criterion is established, and used to construct shear and tension constant life diagrams (CLD's) with data for nine R - values. The effects of a more duc tile urethne resin are also explored. A previous study of thick adhesives testing is extended to mixed mode fracture mechanics testing in Section 7. Mechanisms of static and fatigue crack extension near the laminate adherend interface are reported in deta il. Data are presented for mixed mode adhesive fracture, compared to mixed mode fracture in ply delamination. Fatigue crack growth exponents are also developed for a mixed mode cracked lap shear coupon. The data for fatigue trends and relative failure stra ins and exponents are compared for various blade component materials in Section 8. The effects of temperature and seawater saturation are considered for selected materials of interest for wind and hydrokinetic turbine blades in Section 9. Section 10 gives detailed conclusions for each section. A cknowledgements The research presented in this report was carried out under Sandia National Laboratories purchase orders 1325028 an d 1543945 between 2010 and 2015, with support from the DOE Wind and Water Technologies Office . In addition to the authors listed, significant contributions were made by Patrick Flaherty, Pancastya Agastra, Michael Schuster, and Michael Voth. Industry m aterials suppliers include Vectorply, Saertex, OCV, AGY, Bayer, Ashland, 3M and Nextel. Industry suppliers with significant contributions to the study were Hexion, PPG, Reichhold, Gurit and NEPTCO. Intentionally Left Blank

17 WIND ENERGY↗

External Access to the TREXR Database

The DOE Advanced Reactor Technology program has supported knowledge preservation efforts to recover and preserve fuel data from the US sodium cooled fast reactor (SFR) program. Efforts have focused on establishing databases of experimental data gene rated during the Integral Fast Reactor program (at EBR-II, FFTF, and TREAT) as well as during related out-of-pile examinations. The information in these databases is essential to support further development and licensing activities of advanced fast reactor designs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

M4SF-18LL010302082-Thermodynamic Database Development and Identification of Actinide Sequestration in Corrosion Products

This progress report (Level 4 Milestone Number M4SF-18LL010302082) summarizes research conducted at Lawrence Livermore National Laboratory (LLNL) within the Crystalline International Collaborations Activity Number SF-18LL010302081. The activity is focused on our long-term commitment of engaging our partners in international nuclear waste repository research. This includes participation in the following activities: actinide sequestration in steel corrosion products (Enrica Balboni), Nuclear Energy Agency Thermochemical Database (NEA TDB) Project (Cindy Atkins-Duffin), thermodynamic database collaborations (Tom Wolery), and surface complexation model international collaborations (Mavrik Zavarin).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

PV Reliability Operations and Maintenance (PVROM) Database Initiative: 2014 Project Report

To fill a major knowledge gap, Sandia National Laboratories (SNL) and the Electric Power Research Institute (EPRI) are jointly engaged in a multi-year research effort, supported by the Department of Energy’s SunShot Program, to examine real-world photovoltaic (PV) plant reliability and performance. Findings and analyses, derived from field data documented in the PV Reliability Operations Maintenance (PVROM) database tool as well as from convened workshops and working group discussions, are intended to inform industry best practices around the optimal operations and maintenance (O&M) of solar PV assets. To improve upon and evolve existing solar PV O&M approaches, this report: 1. Provides perspective on the concept of PV “system” reliability and how it can inform plant design, operations, and maintenance decisions that produce better long-term outcomes; 2. Describes the PVROM data collection tool, its technical capabilities, and results generated from database content in 2014; 3. Presents ongoing research efforts that are meant to drive the solar industry toward PV O&M best practice protocols and standards; and 4. Reflects on future areas of inquiry that can help better forecast plant health (e.g., system component availability, component wear out, etc.) and associated lifecycle costs. Ultimately, this report adds to the knowledge base of improving PV system O&M activities by discussing data collection and analysis techniques that can be used to better understand and enhance the reliability, availability, and performance of a photovoltaic system.

14 SOLAR ENERGY↗

User Guide for the Public PC and NGCC CO 2 Capture Retrofit Database Models

The United States (U.S.) Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has produced three carbon capture retrofit databases (CCRDs), which contain a collection of units selected from the power generation and industrial sources (IND) sectors located in the United States that are either in operating or standby status. The power generation category is subdivided into the post-combustion (PC) CCRD – containing coal-fired and atmospheric fluidized bed (AFB) units – and the natural gas combined cycle (NGCC) CCRD – containing natural gas-fired combined cycle and combined cycle single shaft units. The IND CCRD contains facilities from the ammonia, cement, ethanol, hydrogen, and natural gas processing industries. Public versions of these databases were created for use by individuals interested in exploring the impact of retrofitting plants with carbon capture. The power versions contain data from the NETL baseline reports as examples of information that a user can enter for plants of interest. This report is intended to provide a general guide to each of the power CCRDs. Efforts have been made to ensure similarities between each of the CCRDs. However, as the sources of CO 2 vary, differences will exist – most notably in the IND CCRD. Therefore, the PC and NGCC CCRDs are discussed in this guide.

20 FOSSIL-FUELED POWER PLANTS↗

Energy Storage Policy Summaries for the Global Energy Storage Database

This report includes energy storage policy analysis from six states: Arizona, California, Massachusetts, Nevada, New Mexico, and New York. These summaries offer prototypes for summaries that will subsequently be prepared for all 50 states (and territories). There is presently a shortage of comprehensive energy storage policy analysis that public utility regulators can call upon to inform policymaking in their own jurisdictions. The state policy summaries that will be offered publicly on the Global Energy Storage Database (GESDB) will include analysis on the executive directives, legislation, regulations pertaining to energy storage that have been adopted by an individual state, along with perspective on the remaining policy issues pertaining to storage that a state will be likely to address in the future. It is anticipated that public utility regulators in particular will find the database to be a useful resource in benchmarking policy approaches critical to the continued development of an energy storage marketplace in the U.S., including policy approaches specific to storage and renewables procurement targets, interconnection standards, valuation of energy storage, rate reform and tariff design specific to energy storage, consideration of multiple uses for storage at the distribution level, and potential revisions to existing state net metering programs to accommodate an expected growth of energy storage technologies.

25 ENERGY STORAGE↗

HIV Databases video tutorial on use of the HIV sequence quality control tool

The HIV Databases at LANL (https://www.hiv.lanl.gov) provide many tools for HIV data retrieval and analysis. The quality control tool (https://www.hiv.lanl.gov/content/sequence/QC/index.html) is used to check the quality of new HIV sequence data, help the user determine which subtype of virus belongs to, and prepare the data for submission to the database. This video gives a 10 minute overview of the use of the tool and illustrates results form a sample data set.

59 BASIC BIOLOGICAL SCIENCES↗